388 resultados para Air Pollutants, Occupational
Resumo:
Background/aim: A timely evaluation of the Australian Competency Standards for Entry-Level Occupational Therapists (1994) was conducted. This thorough investigation comprised a literature review exploring the concept of competence and the applications of competency standards; systematic benchmarking of the Australian Occupational Therapy Competency Standards (OT AUSTRALIA, 1994) against other national and international competency standards and other affiliated documents, from occupational therapy and other cognate disciplines; and extensive nationwide consultation with the professional community. This paper explores and examines the similarities and disparities between occupational therapy competency standards documents available in English from Australia and other countries.----- Methods: An online search for national occupational therapy competency standards located 10 documents, including the Australian competencies.----- Results: Four 'frameworks' were created to categorise the documents according to their conceptual underpinnings: Technical-Prescriptive, Enabling, Educational and Meta-Cognitive. Other characteristics that appeared to impact the design, content and implementation of competency standards, including definitions of key concepts, authorship, national and cultural priorities, scope of services, intended use and review mechanisms, were revealed.----- Conclusion: The proposed 'frameworks' and identification of influential characteristics provided a 'lens' through which to understand and evaluate competency standards. While consistent application of and attention to some of these characteristics appear to consolidate and affirm the authority of competency standards, it is suggested that the national context should be a critical determinant of the design and content of the final document. The Australian Occupational Therapy Competency Standards (OT AUSTRALIA, 1994) are critiqued accordingly, and preliminary recommendations for revision are proposed.
Resumo:
Cross-cultural research in occupational stress and coping has produced a wealth of knowledge. Although advancement has been made, there are still problems to be solved. One of these problems is the confusion generated in the literature by researchers claiming nation or country as representing cultural values, and the use of the two terms interchangeably. It remains unclear whether this practice is correct. The present paper reported on this by using 511 full time employees from Australia, Singapore and Sri Lanka to study occupational stress and coping. Results revealed that cultural value paradigm (i.e., Individualism-Collectivism) was distributed across the three nations, such that over 60% of participants across the three nations were either high or low in both I-C paradigms. The findings also indicated that the relationship between cultural value paradigm and country impacted on stress and coping differently. The study shows that significant differences exist within country, as well as between countries, such that any attempt to equate culture with country becomes problematic. Therefore, these findings establish that country or nation was not the same as culture values and could not be used interchangeably.
Resumo:
Concern regarding the health effects of indoor air quality has grown in recent years, due to the increased prevalence of many diseases, as well as the fact that many people now spend most of their time indoors. While numerous studies have reported on the dynamics of aerosols indoors, the dynamics of bioaerosols in indoor environments are still poorly understood and very few studies have focused on fungal spore dynamics in indoor environments. Consequently, this work investigated the dynamics of fungal spores in indoor air, including fungal spore release and deposition, as well as investigating the mechanisms involved in the fungal spore fragmentation process. In relation to the investigation of fungal spore dynamics, it was found that the deposition rates of the bioaerosols (fungal propagules) were in the same range as the deposition rates of nonbiological particles and that they were a function of their aerodynamic diameters. It was also found that fungal particle deposition rates increased with increasing ventilation rates. These results (which are reported for the first time) are important for developing an understanding of the dynamics of fungal spores in the air. In relation to the process of fungal spore fragmentation, important information was generated concerning the airborne dynamics of the spores, as well as the part/s of the fungi which undergo fragmentation. The results obtained from these investigations into the dynamics of fungal propagules in indoor air significantly advance knowledge about the fate of fungal propagules in indoor air, as well as their deposition in the respiratory tract. The need to develop an advanced, real-time method for monitoring bioaerosols has become increasingly important in recent years, particularly as a result of the increased threat from biological weapons and bioterrorism. However, to date, the Ultraviolet Aerodynamic Particle Sizer (UVAPS, Model 3312, TSI, St Paul, MN) is the only commercially available instrument capable of monitoring and measuring viable airborne micro-organisms in real-time. Therefore (for the first time), this work also investigated the ability of the UVAPS to measure and characterise fungal spores in indoor air. The UVAPS was found to be sufficiently sensitive for detecting and measuring fungal propagules. Based on fungal spore size distributions, together with fluorescent percentages and intensities, it was also found to be capable of discriminating between two fungal spore species, under controlled laboratory conditions. In the field, however, it would not be possible to use the UVAPS to differentiate between different fungal spore species because the different micro-organisms present in the air may not only vary in age, but may have also been subjected to different environmental conditions. In addition, while the real-time UVAPS was found to be a good tool for the investigation of fungal particles under controlled conditions, it was not found to be selective for bioaerosols only (as per design specifications). In conclusion, the UVAPS is not recommended for use in the direct measurement of airborne viable bioaerosols in the field, including fungal particles, and further investigations into the nature of the micro-organisms, the UVAPS itself and/or its use in conjunction with other conventional biosamplers, are necessary in order to obtain more realistic results. Overall, the results obtained from this work on airborne fungal particle dynamics will contribute towards improving the detection capabilities of the UVAPS, so that it is capable of selectively monitoring and measuring bioaerosols, for which it was originally designed. This work will assist in finding and/or improving other technologies capable of the real-time monitoring of bioaerosols. The knowledge obtained from this work will also be of benefit in various other bioaerosol applications, such as understanding the transport of bioaerosols indoors.
Resumo:
As climate change will entail new conditions for the built environment, the thermal behaviour of air-conditioned office buildings may also change. Using building computer simulations, the impact of warmer weather is evaluated on the design and performance of air-conditioned office buildings in Australia, including the increased cooling loads and probable indoor temperature increases due to a possibly undersized air-conditioning system, as well as the possible change in energy use. It is found that existing office buildings would generally be able to adapt to the increasing warmth of year 2030 Low and High scenarios projections and the year 2070 Low scenario projection. However, for the 2070 High scenario, the study indicates that the existing office buildings in all capital cities of Australia would suffer from overheating problems. For existing buildings designed for current climate conditions, it is shown that there is a nearly linear correlation between the increase of average external air temperature and the increase of building cooling load. For the new buildings designed for warmer scenarios, a 28-59% increase of cooling capacity under the 2070 High scenario would be required.
Resumo:
Introduction Polybrominated diphenyl ethers (PBDEs) are considered to be a cost effective and efficient way to reduce the possibility of product ignition and inhibit the spread of fire, thereby limiting harm caused by fires. PBDEs are incorporated into a wide variety of manufactured products and are now considered an ubiquitous contaminant found worldwide in biological and environmental samples . In comparison to traditional persistent organic pollutants (POPs), the exposure modes of PBDEs in humans are less well defined, although dietary sources, inhalation (air/particulate matter) and dust ingestion have been reported 2-4. Limited investigations of population specific factors such as age or gender and PBDE concentrations report: no conclusive correlation by age in adults ; higher concentrations in children ; similar concentrations in maternal and cord blood ; and no gender differences . After preliminary findings of higher PBDE concentrations in children than in adults in Australia11 we sought to investigate at what age the PBDE concentrations peaked in an effort to focus exposure studies. This investigation involved the collection of blood samples from young age groups and the development of a simple model to predict PBDE concentrations by age in Australia.
Resumo:
In paper has been to investigate the morphological patterns and kinetics of PDMS spreading on silicon wafer using combination of techniques like ellipsometry, atomic force microscope (AFM), scanning electron microscope (SEM) and optical microscopy. A macroscopic silicone oil drops as well as PDMS water based emulsions were studied after deposition on a flat surface of silicon wafer in air, water and vacuum. our own measurements using an imaging ellipsometer, which also clearly shows the presence of a precursor film. The diffusion constant of this film, measured with a 60 000 cS PDMS sample spreading on a hydrophilic silicon wafer, is Df = 1.4 10-11 m2/s. Regardless of their size, density and method of deposition, droplets on both types of wafer (hydrophilic and hydrophobic) flatten out over a period of many hours, up to 3 days. During this process neighbouring droplets may coalesce, but there is strong evidence that some of the PDMS from the droplets migrates into a thin, continuous film that covers the surface in between droplets. The thin film appears to be ubiquitous if there has been any deposition of PDMS. However, this statement needs further verification. One question is whether the film forms immediately after forced drying, or whether in some or all cases it only forms by spreading from isolated droplets as they slowly flatten out.
Resumo:
Despite more than three decades of research, there is a limited understanding of the transactional processes of appraisal, stress and coping. This has led to calls for more focused research on the entire process that underlies these variables. To date, there remains a paucity of such research. The present study examined Lazarus and Folkmans (1984) transactional model of stress and coping. One hundred and twenty nine Australian participants with full time employment (i.e. nurses and administration employees) were recruited. There were 49 male (age mean = 34, SD = 10.51) and 80 female (age mean = 36, SD = 10.31) participants. The analysis of three path models indicated that in addition to the original paths, which were found in Lazarus and Folkmans transactional model (primary appraisal-->secondary appraisal-->stress-->coping), there were also direct links between primary appraisal and stress level time one and between stress level time one to stress level time two. This study has provided additional insights into the transactional process which will extend our understanding of how individuals appraise, cope and experience occupational stress.