Resumo:
Radial profiles of magnetic fields in the electrostatic (E) and electromagnetic (H) modes of low-frequency (∼500) inductively coupled plasmas (ICP) were measured using miniature magnetic probes. A simplified plasma fluid model explaining the generation of the second harmonics of the azimuthal magnetic field in the plasma source was proposed. Because of apparent similarity in the procedure of derivation of the pondermotive force-caused nonlinear terms, pronounced generation of the nonlinear static azimuthal magnetic field could be expected.
Resumo:
The efficiency of the excitation of surface plasma waves in the presence of external, steady crossed magnetic and electric fields is studied analytically and numerically for a geometry in which the waves propagate along the interface between a plasma-like medium and a metal in the direction transverse to both fields. The magnetic and electric fields are assumed to be parallel and transverse to the interface, respectively. The condition for which the drift instability of the surface wave arises is found.
Resumo:
The generation of a correlation matrix for set of genomic sequences is a common requirement in many bioinformatics problems such as phylogenetic analysis. Each sequence may be millions of bases long and there may be thousands of such sequences which we wish to compare, so not all sequences may fit into main memory at the same time. Each sequence needs to be compared with every other sequence, so we will generally need to page some sequences in and out more than once. In order to minimize execution time we need to minimize this I/O. This paper develops an approach for faster and scalable computing of large-size correlation matrices through the maximal exploitation of available memory and reducing the number of I/O operations. The approach is scalable in the sense that the same algorithms can be executed on different computing platforms with different amounts of memory and can be applied to different bioinformatics problems with different correlation matrix sizes. The significant performance improvement of the approach over previous work is demonstrated through benchmark examples.
Resumo:
Bit-Stream based control, which uses one bit wide signals to control power electronics applications, is a new approach for controller design in power electronic systems. Bit-Stream signals are inherently high frequency in nature, and as such some form of down sampling or modulating is essential to avoid excessive switching losses. This paper presents a novel three-phase space vector modulator, which is based on the Bit-Stream technique and suitable for standard three-phase inverter systems. The proposed modulator simultaneously converts a two phase reference to the three-phase domain and reduces switching frequencies to reasonable levels. The modulator consumes relatively few logic elements and does not require sector detectors, carrier oscillators or trigonometric functions. The performance of the modulator was evaluated using ModelSim. Results indicate that, subject to limits on the modulation index, the proposed modulator delivers a spread-spectrum output with total harmonic distortion comparable to standard space vector pulse width modulation techniques.
Resumo:
A Monte Carlo model of an Elekta iViewGT amorphous silicon electronic portal imaging device (a-Si EPID) has been validated for pre-treatment verification of clinical IMRT treatment plans. The simulations involved the use of the BEAMnrc and DOSXYZnrc Monte Carlo codes to predict the response of the iViewGT a-Si EPID model. The predicted EPID images were compared to the measured images obtained from the experiment. The measured EPID images were obtained by delivering a photon beam from an Elekta Synergy linac to the Elekta iViewGT a-Si EPID. The a-Si EPID was used with no additional build-up material. Frame averaged EPID images were acquired and processed using in-house software. The agreement between the predicted and measured images was analyzed using the gamma analysis technique with acceptance criteria of 3% / 3 mm. The results show that the predicted EPID images for four clinical IMRT treatment plans have a good agreement with the measured EPID signal. Three prostate IMRT plans were found to have an average gamma pass rate of more than 95.0 % and a spinal IMRT plan has the average gamma pass rate of 94.3 %. During the period of performing this work a routine MLC calibration was performed and one of the IMRT treatments re-measured with the EPID. A change in the gamma pass rate for one field was observed. This was the motivation for a series of experiments to investigate the sensitivity of the method by introducing delivery errors, MLC position and dosimetric overshoot, into the simulated EPID images. The method was found to be sensitive to 1 mm leaf position errors and 10% overshoot errors.
Resumo:
Recent discussions of energy security and climate change have attracted significant attention to clean energy. We hypothesize that rising prices of conventional energy and/or placement of a price on carbon emissions would encourage investments in clean energy firms. The data from three clean energy indices show that oil prices and technology stock prices separately affect the stock prices of clean energy firms. However, the data fail to demonstrate a significant relationship between carbon prices and the stock prices of the firms.
Resumo:
Modulation and control of a cascade multilevel inverter, which has a high potential in future wind generation applications, are presented. The inverter is a combination of a high power, three level “bulk inverter” and a low power “conditioning inverter”. To minimize switching losses, the bulk inverter operates at a low frequency producing square wave outputs while high frequency conditioning inverter is used to suppress harmonic content produced by the bulk inverter output. This paper proposes an improved Space Vector Modulation (SVM) algorithm and a neutral point potential balancing technique for the inverter. Furthermore, a maximum power tracking controller for the Permanent Magnet Synchronous Generator (PMSG) is described in detail. The proposed SVM technique eliminates most of the computational burdens on the digital controller and renders a greater controllability under varying DC-link voltage conditions. The DC-link capacitor voltage balancing of both bulk and conditioning inverters is carried out using Redundant State Selection (RSS) method and is explained in detail. Experimental results are presented to verify the proposed modulation and control techniques.
Resumo:
Purpose Small field x-ray beam dosimetry is difficult due to a lack of lateral electronic equilibrium, source occlusion, high dose gradients and detector volume averaging. Currently there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Methods Small field sizes were defined by BrainLAB circular cones (4 – 30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated by Monte Carlo methods using BEAMnrc and correction factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Results For the small fields of 4 to 30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Conclusions We conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.
Resumo:
Aim A new method of penumbral analysis is implemented which allows an unambiguous determination of field size and penumbra size and quality for small fields and other non-standard fields. Both source occlusion and lateral electronic disequilibrium will affect the size and shape of cross-axis profile penumbrae; each is examined in detail. Method A new method of penumbral analysis is implemented where the square of the derivative of the cross-axis profile is plotted. The resultant graph displays two peaks in the place of the two penumbrae. This allows a strong visualisation of the quality of a field penumbra, as well as a mathematically consistent method of determining field size (distance between the two peak’s maxima), and penumbra (full-widthtenth-maximum of peak). Cross-axis profiles were simulated in a water phantom at a depth of 5 cm using Monte Carlo modelling, for field sizes between 5 and 30 mm. The field size and penumbra size of each field was calculated using the method above, as well as traditional definitions set out in IEC976. The effect of source occlusion and lateral electronic disequilibrium on the penumbrae was isolated by repeating the simulations removing electron transport and using an electron spot size of 0 mm, respectively. Results All field sizes calculated using the traditional and proposed methods agreed within 0.2 mm. The penumbra size measured using the proposed method was systematically 1.8 mm larger than the traditional method at all field sizes. The size of the source had a larger effect on the size of the penumbra than did lateral electronic disequilibrium, particularly at very small field sizes. Conclusion Traditional methods of calculating field size and penumbra are proved to be mathematically adequate for small fields. However, the field size definition proposed in this study would be more robust amongst other nonstandard fields, such as flattening filter free. Source occlusion plays a bigger role than lateral electronic disequilibrium in small field penumbra size.
Resumo:
This PhD research has provided novel solutions to three major challenges which have prevented the wide spread deployment of speaker recognition technology: (1) combating enrolment/ verification mismatch, (2) reducing the large amount of development and training data that is required and (3) reducing the duration of speech required to verify a speaker. A range of applications of speaker recognition technology from forensics in criminal investigations to secure access in banking will benefit from the research outcomes.