586 resultados para Bureaucratic quality
Resumo:
This thesis details methodology to estimate urban stormwater quality based on a set of easy to measure physico-chemical parameters. These parameters can be used as surrogate parameters to estimate other key water quality parameters. The key pollutants considered in this study are nitrogen compounds, phosphorus compounds and solids. The use of surrogate parameter relationships to evaluate urban stormwater quality will reduce the cost of monitoring and so that scientists will have added capability to generate a large amount of data for more rigorous analysis of key urban stormwater quality processes, namely, pollutant build-up and wash-off. This in turn will assist in the development of more stringent stormwater quality mitigation strategies. The research methodology was based on a series of field investigations, laboratory testing and data analysis. Field investigations were conducted to collect pollutant build-up and wash-off samples from residential roads and roof surfaces. Past research has identified that these impervious surfaces are the primary pollutant sources to urban stormwater runoff. A specially designed vacuum system and rainfall simulator were used in the collection of pollutant build-up and wash-off samples. The collected samples were tested for a range of physico-chemical parameters. Data analysis was conducted using both univariate and multivariate data analysis techniques. Analysis of build-up samples showed that pollutant loads accumulated on road surfaces are higher compared to the pollutant loads on roof surfaces. Furthermore, it was found that the fraction of solids smaller than 150 ìm is the most polluted particle size fraction in solids build-up on both roads and roof surfaces. The analysis of wash-off data confirmed that the simulated wash-off process adopted for this research agrees well with the general understanding of the wash-off process on urban impervious surfaces. The observed pollutant concentrations in wash-off from road surfaces were different to pollutant concentrations in wash-off from roof surfaces. Therefore, firstly, the identification of surrogate parameters was undertaken separately for roads and roof surfaces. Secondly, a common set of surrogate parameter relationships were identified for both surfaces together to evaluate urban stormwater quality. Surrogate parameters were identified for nitrogen, phosphorus and solids separately. Electrical conductivity (EC), total organic carbon (TOC), dissolved organic carbon (DOC), total suspended solids (TSS), total dissolved solids (TDS), total solids (TS) and turbidity (TTU) were selected as the relatively easy to measure parameters. Consequently, surrogate parameters for nitrogen and phosphorus were identified from the set of easy to measure parameters for both road surfaces and roof surfaces. Additionally, surrogate parameters for TSS, TDS and TS which are key indicators of solids were obtained from EC and TTU which can be direct field measurements. The regression relationships which were developed for surrogate parameters and key parameter of interest were of a similar format for road and roof surfaces, namely it was in the form of simple linear regression equations. The identified relationships for road surfaces were DTN-TDS:DOC, TP-TS:TOC, TSS-TTU, TDS-EC and TSTTU: EC. The identified relationships for roof surfaces were DTN-TDS and TSTTU: EC. Some of the relationships developed had a higher confidence interval whilst others had a relatively low confidence interval. The relationships obtained for DTN-TDS, DTN-DOC, TP-TS and TS-EC for road surfaces demonstrated good near site portability potential. Currently, best management practices are focussed on providing treatment measures for stormwater runoff at catchment outlets where separation of road and roof runoff is not found. In this context, it is important to find a common set of surrogate parameter relationships for road surfaces and roof surfaces to evaluate urban stormwater quality. Consequently DTN-TDS, TS-EC and TS-TTU relationships were identified as the common relationships which are capable of providing measurements of DTN and TS irrespective of the surface type.
Resumo:
Interferometry is a sensitive technique for recording tear film surface irregularities in a noninvasive manner. At the same time, the technique is hindered by natural eye movements resulting in measurement noise. Estimating tear film surface quality from interferograms can be reduced to a spatial-average-localized weighted estimate of the first harmonic of the interference fringes. However, previously reported estimation techniques proved to perform poorly in cases where the pattern fringes were significantly disturbed. This can occur in cases of measuring tear film surface quality on a contact lens on the eye or in a dry eye. We present a new estimation technique for extracting the first harmonic from the interference fringes that combines the traditional spectral estimation techniques with morphological image processing techniques. The proposed technique proves to be more robust to changes in interference fringes caused by natural eye movements and the degree of dryness of the contact lens and corneal surfaces than its predecessors, resulting in tear film surface quality estimates that are less noisy
Resumo:
Quality has been an important factor for shopping centers in competitive conditions. However, quality measurement has no standard. In Surabaya, only two regional shopping centers will be measured in this research. The objective is assessing quality of shopping centers building using Analytical Hierarchy Process (AHP) method and calculating the Building Quality Index. An overall ranking of Hierarchy priorities of quality criteria founded as a result from AHP analysis. Access and Circulation became the highest priority in affecting quality of shopping centers building according to respondents’ perception of quality. Weightened value as a result from comparison between two shopping centers as follows: Tunjungan Plaza get 0,732 point and Surabaya Plaza get 0,268 point. The first shopping center got higher weight than the second shopping center. The BQI for Tunjungan Plaza is 66% and for Surabaya Plaza is 64%.
Resumo:
Modelling of interferometric signals related to tear film surface quality is considered. In the context of tear film surface quality estimation in normal healthy eyes, two clinical parameters are of interest: the build-up time, and the average interblink surface quality. The former is closely related to the signal derivative while the latter to the signal itself. Polynomial signal models, chosen for a particular set of noisy interferometric measurements, can be optimally selected, in some sense, with a range of information criteria such as AIC, MDL, Cp, and CME. Those criteria, however, do not always guarantee that the true derivative of the signal is accurately represented and they often overestimate it. Here, a practical method for judicious selection of model order in a polynomial fitting to a signal is proposed so that the derivative of the signal is adequately represented. The paper highlights the importance of context-based signal modelling in model order selection.
Resumo:
This paper describes control methods for proper load sharing between parallel converters connected in a microgrid and supplied by distributed generators (DGs). It is assumed that the microgrid spans a large area and it supplies loads in both in grid connected and islanded modes. A control strategy is proposed to improve power quality and proper load sharing in both islanded and grid connected modes. It is assumed that each of the DGs has a local load connected to it which can be unbalanced and/or nonlinear. The DGs compensate the effects of unbalance and nonlinearity of the local loads. Common loads are also connected to the microgrid, which are supplied by the utility grid under normal conditions. However during islanding, each of the DGs supplies its local load and shares the common load through droop characteristics. Both impedance and motor loads are considered to verify the system response. The efficacy of the controller has been validated through simulation for various operating conditions using PSCAD. It has been found through simulation that the total Harmonic Distortion (THD) of the of the microgrid voltage is about 10% and the negative and zero sequence component are around 20% of the positive sequence component before compensation. After compensation, the THD remain below 0.5%, whereas, negative and zero sequence components of the voltages remain below 0.02% of the positive sequence component.
Resumo:
Residential aged care in Australia does not have a system of quality assessment related to clinical outcomes, creating a significant gap in quality monitoring. Clinical outcomes represent the results of all inputs into care, thus providing an indication of the success of those inputs. To fill this gap, an assessment tool based on resident outcomes (the ResCareQA) was developed and evaluated in collaboration with residential care providers. A useful output of the ResCareQA is a profile of resident clinical status, and this paper will use such outputs to present a snapshot of nine residential facilities. Such comprehensive data has not yet been available within Australia, so this will provide an important insight. ResCareQA data was collected from all residents (N=498) of nine aged care facilities from two major aged care providers. For each facility, numerator–denominator data were calculated to assess the degree of potential clinical problems. Results varied across clinical areas and across facilities, and rank-ordered facility results for selected clinical areas are reviewed and discussed. Use of the ResCareQA to generate clinical outcome data provides a concrete means of monitoring care quality within residential facilities; regular use of the ResCareQA could thus contribute to improved care outcomes within residential aged care.
Resumo:
This paper has two main sections, the first of which presents a summarized review of the literature concerning previous studies on the implementation of ISO 9000 quality management systems (QMSs) both in global construction companies as well as in Indonesian construction firms, and the perceived correlation between organisational culture and QMS practices in the construction sector. The first section of the paper contributes to the development of the second section, which presents details of the research project being undertaken. Based on the fundamental questions that led to the development of the main research objectives, suitable research methods have been developed in order to meet these objectives. Primary data will be collected by use of a mixed methods approach, i.e., questionnaire surveys and focus group discussions/interviews in order to obtain opinions from respondents drawn from targeted ISO construction firms. Most of the data expected to be obtained will be in future be analyzed using statistical software then the findings will be discussed in order to ultimately develop a culture-based QMS framework.
Resumo:
Purpose: This two-part research project was undertaken as part of the planning process by Queensland Health (QH), Cancer Screening Services Unit (CSSU), Queensland Bowel Cancer Screening Program (QBCSP), in partnership with the National Bowel Cancer Screening Program (NBCSP), to prepare for the implementation of the NBCSP in public sector colonoscopy services in QLD in late 2006. There was no prior information available on the quality of colonoscopy services in Queensland (QLD) and no prior studies that assessed the quality of colonoscopy training in Australia. Furthermore, the NBCSP was introduced without extra funding for colonoscopy service improvement or provision for increases in colonoscopic capacity resulting from the introduction of the NBCSP. The main purpose of the research was to record baseline data on colonoscopy referral and practice in QLD and current training in colonoscopy Australia-wide. It was undertaken from a quality improvement perspective. Implementation of the NBCSP requires that all aspects of the screening pathway, in particular colonoscopy services for the assessment of positive Faecal Occult Blood Tests (FOBTs), will be effective, efficient, equitable and evidence-based. This study examined two important aspects of the continuous quality improvement framework for the NBCSP as they relate to colonoscopy services: (1) evidence-based practice, and (2) quality of colonoscopy training. The Principal Investigator was employed as Senior Project Officer (Training) in the QBCSP during the conduct of this research project. Recommendations from this research have been used to inform the development and implementation of quality improvement initiatives for provision of colonoscopy in the NBCSP, its QLD counterpart the QBCSP and colonoscopy services in QLD, in general. Methods – Part 1 Chart audit of evidence-based practice: The research was undertaken in two parts from 2005-2007. The first part of this research comprised a retrospective chart audit of 1484 colonoscopy records (some 13% of all colonoscopies conducted in public sector facilities in the year 2005) in three QLD colonoscopy services. Whilst some 70% of colonoscopies are currently conducted in the private sector, only public sector colonoscopy facilities provided colonoscopies under the NBCSP. The aim of this study was to compare colonoscopy referral and practice with explicit criteria derived from the National Health & Medical Research Council (NHMRC) (1999) Clinical Practice Guidelines for the Prevention, Early Detection and Management of Colorectal Cancer, and describe the nature of variance with the guidelines. Symptomatic presentations were the most common indication for colonoscopy (60.9%). These comprised per rectal bleeding (31.0%), change of bowel habit (22.1%), abdominal pain (19.6%), iron deficiency anaemia (16.2%), inflammatory bowel disease (8.9%) and other symptoms (11.4%). Surveillance and follow-up colonoscopies accounted for approximately one-third of the remaining colonoscopy workload across sites. Gastroenterologists (GEs) performed relatively more colonoscopies per annum (59.9%) compared to general surgeons (GS) (24.1%), colorectal surgeons (CRS) (9.4%) and general physicians (GPs) (6.5%). Guideline compliance varied with the designation of the colonoscopist. Compliance was lower for CRS (62.9%) compared to GPs (76.0%), GEs (75.0%), GSs (70.9%, p<0.05). Compliance with guideline recommendations for colonoscopic surveillance for family history of colorectal cancer (23.9%), polyps (37.0%) and a past history of bowel cancer (42.7%), was by comparison significantly lower than for symptomatic presentations (94.4%), (p<0.001). Variation with guideline recommendations occurred more frequently for polyp surveillance (earlier than guidelines recommend, 47.9%) and follow-up for past history of bowel cancer (later than recommended, 61.7%, p<0.001). Bowel cancer cases detected at colonoscopy comprised 3.6% of all audited colonoscopies. Incomplete colonoscopies occurred in 4.3% of audited colonoscopies and were more common among women (76.6%). For all colonoscopies audited, the rate of incomplete colonoscopies for GEs was 1.6% (CI 0.9-2.6), GPs 2.0% (CI 0.6-7.2), GS 7.0% (CI 4.8-10.1) and CRS 16.4% (CI 11.2-23.5). 18.6% (n=55) of patients with a documented family history of bowel cancer had colonoscopy performed against guidelines recommendations (for general (category 1) population risk, for reasons of patient request or family history of polyps, rather than for high risk status for colorectal cancer). In general, family history was inadequately documented and subsequently applied to colonoscopy referral and practice. Methods - Part 2 Surveys of quality of colonoscopy training: The second part of the research consisted of Australia-wide anonymous, self-completed surveys of colonoscopy trainers and their trainees to ascertain their opinions on the current apprenticeship model of colonoscopy in Australia and to identify any training needs. Overall, 127 surveys were received from colonoscopy trainers (estimated response rate 30.2%). Approximately 50% of trainers agreed and 27% disagreed that current numbers of training places were adequate to maintain a skilled colonoscopy workforce in preparation for the NBCSP. Approximately 70% of trainers also supported UK-style colonoscopy training within dedicated accredited training centres using a variety of training approaches including simulation. A collaborative approach with the private sector was seen as beneficial by 65% of trainers. Non-gastroenterologists (non-GEs) were more likely than GEs to be of the opinion that simulators are beneficial for colonoscopy training (χ2-test = 5.55, P = 0.026). Approximately 60% of trainers considered that the current requirements for recognition of training in colonoscopy could be insufficient for trainees to gain competence and 80% of those indicated that ≥ 200 colonoscopies were needed. GEs (73.4%) were more likely than non-GEs (36.2%) to be of the opinion that the Conjoint Committee standard is insufficient to gain competence in colonoscopy (χ2-test = 16.97, P = 0.0001). The majority of trainers did not support training either nurses (73%) or GPs in colonoscopy (71%). Only 81 (estimated response rate 17.9%) surveys were received from GS trainees (72.1%), GE trainees (26.3%) and GP trainees (1.2%). The majority were males (75.9%), with a median age 32 years and who had trained in New South Wales (41.0%) or Victoria (30%). Overall, two-thirds (60.8%) of trainees indicated that they deemed the Conjoint Committee standard sufficient to gain competency in colonoscopy. Between specialties, 75.4% of GS trainees indicated that the Conjoint Committee standard for recognition of colonoscopy was sufficient to gain competence in colonoscopy compared to only 38.5% of GE trainees. Measures of competency assessed and recorded by trainees in logbooks centred mainly on caecal intubation (94.7-100%), complications (78.9-100%) and withdrawal time (51-76.2%). Trainees described limited access to colonoscopy training lists due to the time inefficiency of the apprenticeship model and perceived monopolisation of these by GEs and their trainees. Improvements to the current training model suggested by trainees included: more use of simulation, training tools, a United Kingdom (UK)-style training course, concentration on quality indicators, increased access to training lists, accreditation of trainers and interdisciplinary colonoscopy training. Implications for the NBCSP/QBCSP: The introduction of the NBCSP/QBCSP necessitates higher quality colonoscopy services if it is to achieve its ultimate goal of decreasing the incidence of morbidity and mortality associated with bowel cancer in Australia. This will be achieved under a new paradigm for colonoscopy training and implementation of evidence-based practice across the screening pathway and specifically targeting areas highlighted in this thesis. Recommendations for improvement of NBCSP/QBCSP effectiveness and efficiency include the following: 1. Implementation of NBCSP and QBCSP health promotion activities that target men, in particular, to increase FOBT screening uptake. 2. Improved colonoscopy training for trainees and refresher courses or retraining for existing proceduralists to improve completion rates (especially for female NBCSP/QBCSP participants), and polyp and adenoma detection and removal, including newer techniques to detect flat and depressed lesions. 3. Introduction of colonoscopy training initiatives for trainees that are aligned with NBCSP/QBCSP colonoscopy quality indicators, including measurement of training outcomes using objective quality indicators such as caecal intubation, withdrawal time, and adenoma detection rate. 4. Introduction of standardised, interdisciplinary colonoscopy training to reduce apparent differences between specialties with regard to compliance with guideline recommendations, completion rates, and quality of polypectomy. 5. Improved quality of colonoscopy training by adoption of a UK-style training program with centres of excellence, incorporating newer, more objective assessment methods, use of a variety of training tools such as simulation and rotations of trainees between metropolitan, rural, and public and private sector training facilities. 6. Incorporation of NHMRC guidelines into colonoscopy information systems to improve documentation, provide guideline recommendations at the point of care, use of gastroenterology nurse coordinators to facilitate compliance with guidelines and provision of guideline-based colonoscopy referral letters for GPs. 7. Provision of information and education about the NBCSP/QBCSP, bowel cancer risk factors, including family history and polyp surveillance guidelines, for participants, GPs and proceduralists. 8. Improved referral of NBCSP/QBCSP participants found to have a high-risk family history of bowel cancer to appropriate genetics services.
Resumo:
The increase of life expectancy worldwide during the last three decades has increased age-related disability leading to the risk of loss of quality of life. How to improve quality of life including physical health and mental health for older people and optimize their life potential has become an important health issue. This study used the Theory of Planned Behaviour Model to examine factors influencing health behaviours, and the relationship with quality of life. A cross-sectional mailed survey of 1300 Australians over 50 years was conducted at the beginning of 2009, with 730 completed questionnaires returned (response rate 63%). Preliminary analysis reveals that physiological changes of old age, especially increasing waist circumference and co morbidity was closely related to health status, especially worse physical health summary score. Physical activity was the least adherent behaviour among the respondents compared to eating healthy food and taking medication regularly as prescribed. Increasing number of older people living alone with co morbidity of disease may be the barriers that influence their attitude and self control toward physical activity. A multidisciplinary and integrated approach including hospital and non hospital care is required to provide appropriate services and facilities toward older people.
Resumo:
Background: The systematic collection of high-quality mortality data is a prerequisite in designing relevant drowning prevention programmes. This descriptive study aimed to assess the quality (i.e., level of specificity) of cause-of-death reporting using ICD-10 drowning codes across 69 countries.---------- Methods: World Health Organization (WHO) mortality data were extracted for analysis. The proportion of unintentional drowning deaths coded as unspecified at the 3-character level (ICD-10 code W74) and for which the place of occurrence was unspecified at the 4th character (.9) were calculated for each country as indicators of the quality of cause-of-death reporting.---------- Results: In 32 of the 69 countries studied, the percentage of cases of unintentional drowning coded as unspecified at the 3-character level exceeded 50%, and in 19 countries, this percentage exceeded 80%; in contrast, the percentage was lower than 10% in only 10 countries. In 21 of the 56 countries that report 4-character codes, the percentage of unintentional drowning deaths for which the place of occurrence was unspecified at the 4th character exceeded 50%, and in 15 countries, exceeded 90%; in only 14 countries was this percentage lower than 10%.---------- Conclusion: Despite the introduction of more specific subcategories for drowning in the ICD-10, many countries were found to be failing to report sufficiently specific codes in drowning mortality data submitted to the WHO.