782 resultados para ecotoxicological assessment
Resumo:
Background Skin temperature assessment is a promising modality for early detection of diabetic foot problems, but its diagnostic value has not been studied. Our aims were to investigate the diagnostic value of different cutoff skin temperature values for detecting diabetes-related foot complications such as ulceration, infection, and Charcot foot and to determine urgency of treatment in case of diagnosed infection or a red-hot swollen foot. Materials and Methods The plantar foot surfaces of 54 patients with diabetes visiting the outpatient foot clinic were imaged with an infrared camera. Nine patients had complications requiring immediate treatment, 25 patients had complications requiring non-immediate treatment, and 20 patients had no complications requiring treatment. Average pixel temperature was calculated for six predefined spots and for the whole foot. We calculated the area under the receiver operating characteristic curve for different cutoff skin temperature values using clinical assessment as reference and defined the sensitivity and specificity for the most optimal cutoff temperature value. Mean temperature difference between feet was analyzed using the Kruskal–Wallis tests. Results The most optimal cutoff skin temperature value for detection of diabetes-related foot complications was a 2.2°C difference between contralateral spots (sensitivity, 76%; specificity, 40%). The most optimal cutoff skin temperature value for determining urgency of treatment was a 1.35°C difference between the mean temperature of the left and right foot (sensitivity, 89%; specificity, 78%). Conclusions Detection of diabetes-related foot complications based on local skin temperature assessment is hindered by low diagnostic values. Mean temperature difference between two feet may be an adequate marker for determining urgency of treatment.
Resumo:
Children with developmental co-ordination disorder (DCD) face evident motor difficulties in activities of daily living (ADL). Assessment of their capacity in ADL is essential for diagnosis and intervention, in order to limit the daily consequences of the disorder. The aim of this study is to systematically review potential instruments for standardized and objective assessment of children's capacity in ADL, suited for children with DCD. As a first step, databases of MEDLINE, EMBASE, CINAHL and PsycINFO were searched to identify studies that described instruments with potential for assessment of capacity in ADL. Second, instruments were included for review when two independent reviewers agreed that the instruments: (1) are standardized and objective; (2) assess at activity level and comprise items that reflect ADL, and; (3) are applicable to school-aged children that can move independently. Out of 1507 publications, 66 publications were selected, describing 39 instruments. Seven of these instruments were found to fulfil the criteria and were included for review: the Bruininks-Oseretsky Test of Motor Performance-2 (BOT2); the Do-Eat (Do-Eat); the Movement Assessment Battery for Children-2 (MABC2); the school-Assessment of Motor and Process Skills (schoolAMPS); the Tuffts Assessment of Motor Performance (TAMP); the Test of Gross Motor Development (TGMD); and the Functional Independence Measure for Children (WeeFIM). As a third step, for the included instruments, suitability for children with DCD was discussed based on the ADL comprised, ecological validity and other psychometric properties. We concluded that current instruments do not provide comprehensive and ecologically valid assessment of capacity in ADL as required for children with DCD.
Resumo:
Objective To develop the DCDDaily, an instrument for objective and standardized clinical assessment of capacity in activities of daily living (ADL) in children with developmental coordination disorder (DCD), and to investigate its usability, reliability, and validity. Subjects Five to eight-year-old children with and without DCD. Main measures The DCDDaily was developed based on thorough review of the literature and extensive expert involvement. To investigate the usability (assessment time and feasibility), reliability (internal consistency and repeatability), and validity (concurrent and discriminant validity) of the DCDDaily, children were assessed with the DCDDaily and the Movement Assessment Battery for Children-2 Test, and their parents filled in the Movement Assessment Battery for Children-2 Checklist and Developmental Coordination Disorder Questionnaire. Results 459 children were assessed (DCD group, n = 55; normative reference group, n = 404). Assessment was possible within 30 minutes and in any clinical setting. For internal consistency, Cronbach’s α = 0.83. Intraclass correlation = 0.87 for test–retest reliability and 0.89 for inter-rater reliability. Concurrent correlations with Movement Assessment Battery for Children-2 Test and questionnaires were ρ = −0.494, 0.239, and −0.284, p < 0.001. Discriminant validity measures showed significantly worse performance in the DCD group than in the control group (mean (SD) score 33 (5.6) versus 26 (4.3), p < 0.001). The area under curve characteristic = 0.872, sensitivity and specificity were 80%. Conclusions The DCDDaily is a valid and reliable instrument for clinical assessment of capacity in ADL, that is feasible for use in clinical practice.
Resumo:
Background Patients with diabetic foot disease require frequent screening to prevent complications and may be helped through telemedical home monitoring. Within this context, the goal was to determine the validity and reliability of assessing diabetic foot infection using photographic foot imaging and infrared thermography. Subjects and Methods For 38 patients with diabetes who presented with a foot infection or were admitted to the hospital with a foot-related complication, photographs of the plantar foot surface using a photographic imaging device and temperature data from six plantar regions using an infrared thermometer were obtained. A temperature difference between feet of > 2.2 °C defined a ''hotspot.'' Two independent observers assessed each foot for presence of foot infection, both live (using the Perfusion-Extent-Depth- Infection-Sensation classification) and from photographs 2 and 4 weeks later (for presence of erythema and ulcers). Agreement in diagnosis between live assessment and (the combination of ) photographic assessment and temperature recordings was calculated. Results Diagnosis of infection from photographs was specific (> 85%) but not very sensitive (< 60%). Diagnosis based on hotspots present was sensitive (> 90%) but not very specific (<25%). Diagnosis based on the combination of photographic and temperature assessments was both sensitive (> 60%) and specific (> 79%). Intra-observer agreement between photographic assessments was good (Cohen's j = 0.77 and 0.52 for both observers). Conclusions Diagnosis of foot infection in patients with diabetes seems valid and reliable using photographic imaging in combination with infrared thermography. This supports the intended use of these modalities for the home monitoring of high-risk patients with diabetes to facilitate early diagnosis of signs of foot infection.
Resumo:
To develop and test a custom-built instrument to simultaneously assess tear film surface quality (TFSQ) and subjective vision score (SVS).
Resumo:
The aim of this paper is to present results of research investigating the effectiveness of audio feedback in a third year undergraduate unit. While there is a large and growing body of literature about providing assessment feedback, there is little focussing on the use of audio media. This study employs a mixed method approach, involving semi-structured interviews with academic staff and a survey of students. Analysis of the interview data suggests that there are a number of issues surrounding acceptance of using audio feedback by lecturers. The next stage of the study is to examine the extent to which lecturers change their perceptions as they use audio feedback and to analyse the perceptions of the students (n=120), including the perceived importance of feedback, the ways in which they used the audio feedback and the extent to which they believe they control events that affect them. Ultimately, this study seeks to provide recommendations appropriate to the implementation of audio feedback in higher education.
Resumo:
Dissatisfaction with, and discontinuation from, contact lens wear is a source of major frustration and inconvenience to users, and a problem that is thought to cost the contact lens industry hundreds of millions of dollars each year. By directly and non-invasively monitoring inflammatory cells in the tissues at the front of the eye in symptomatic and asymptomatic lens wearers, the candidate has been able to demonstrate an inflammatory basis for contact lens discomfort. This finding may pave the way towards the development of strategies to make contact lenses more safe and afford greater levels of comfort.
Resumo:
This paper introduces a policy-making support tool called ‘Micro-level Urban ecosystem Sustainability IndeX (MUSIX)’. The index serves as a sustainability assessment model that monitors six aspects of urban ecosystems, hydrology, ecology, pollution, location, design, and efficiency based on parcel-scale indicators. This index is applied in a case study investigation in the Gold Coast City, Queensland, Australia. The outcomes reveal that there are major environmental problems caused by increased impervious surfaces from growing urban development in the study area. The findings suggest that increased impervious surfaces are linked to increased surface runoff, car dependency, transport-related pollution, poor public transport accessibility, and unsustainable built environment. This paper presents how the MUSIX outputs can be used to guide policy-making through the evaluation of existing policies.
Resumo:
Since its inception, the Systems Theory Framework of career development has afforded ready translation into practice, especially into career counselling and qualitative career assessment. Through its clearly articulated constructs and the clarity of its diagrammatic representation, the Systems Theory Framework has facilitated the development of qualitative career assessment instruments as well as a quantitative measure. This article briefly overviews these practical applications of the Systems Theory Framework as well as its application in career counselling through a story telling approach. The article concludes by offering a synthesis of and considering future directions for the Systems Theory Framework’s practical applications.
Resumo:
Career assessment has long held a central place in career counselling since the work of Parsons (1909) signalled the birth of a new field of practice, vocational guidance, and its subsequent iterations of career guidance and counselling and more recently life designing.
Resumo:
Indoor air quality is a critical factor in the classroom due to high people concentration in a unique space. Indoor air pollutant might increase the chance of both long and short-term health problems among students and staff, reduce the productivity of teachers and degrade the student’s learning environment and comfort. Adequate air distribution strategies may reduce risk of infection in classroom. So, the purpose of air distribution systems in a classroom is not only to maximize conditions for thermal comfort, but also to remove indoor contaminants. Natural ventilation has the potential to play a significant role in achieving improvements in IAQ. The present study compares the risk of airborne infection between Natural Ventilation (opening windows and doors) and a Split-System Air Conditioner in a university classroom. The Wells-Riley model was used to predict the risk of indoor airborne transmission of infectious diseases such as influenza, measles and tuberculosis. For each case, the air exchange rate was measured using a CO2 tracer gas technique. It was found that opening windows and doors provided an air exchange rate of 2.3 air changes/hour (ACH), while with the Split System it was 0.6 ACH. The risk of airborne infection ranged between 4.24 to 30.86 % when using the Natural Ventilation and between 8.99 to 43.19% when using the Split System. The difference of airborne infection risk between the Split System and the Natural Ventilation ranged from 47 to 56%. Opening windows and doors maximize Natural Ventilation so that the risk of airborne contagion is much lower than with Split System.
Resumo:
Health challenges present arguably the most significant barrier to sustainable global development. The introduction of ICT in healthcare, especially the application of mobile communications, has created the potential to transform healthcare delivery by making it more accessible, affordable and effective across the developing world. However, current research into the assessment of mHealth from the perspective of developing countries particularly with community Health workers (CHWs) as primary users continues to be limited. The aim of this study is to analyze the contribution of mHealth in enhancing the performance of the health workers and its alignment with existing workflows to guide its utilization. The proposed research takes into account this consideration and aims to examine the task-technology alignment of mHealth for CHWs drawing upon the task technology fit as the theoretical foundation.
Resumo:
Introduction Recent reports have highlighted the prevalence of vitamin D deficiency and suggested an association with excess mortality in critically ill patients. Serum vitamin D concentrations in these studies were measured following resuscitation. It is unclear whether aggressive fluid resuscitation independently influences serum vitamin D. Methods Nineteen patients undergoing cardiopulmonary bypass were studied. Serum 25(OH)D3, 1α,25(OH)2D3, parathyroid hormone, C-reactive protein (CRP), and ionised calcium were measured at five defined timepoints: T1 - baseline, T2 - 5 minutes after onset of cardiopulmonary bypass (CPB) (time of maximal fluid effect), T3 - on return to the intensive care unit, T4 - 24 hrs after surgery and T5 - 5 days after surgery. Linear mixed models were used to compare measures at T2-T5 with baseline measures. Results Acute fluid loading resulted in a 35% reduction in 25(OH)D3 (59 ± 16 to 38 ± 14 nmol/L, P < 0.0001) and a 45% reduction in 1α,25(OH)2D3 (99 ± 40 to 54 ± 22 pmol/L P < 0.0001) and i(Ca) (P < 0.01), with elevation in parathyroid hormone (P < 0.0001). Serum 25(OH)D3 returned to baseline only at T5 while 1α,25(OH)2D3 demonstrated an overshoot above baseline at T5 (P < 0.0001). There was a delayed rise in CRP at T4 and T5; this was not associated with a reduction in vitamin D levels at these time points. Conclusions Hemodilution significantly lowers serum 25(OH)D3 and 1α,25(OH)2D3, which may take up to 24 hours to resolve. Moreover, delayed overshoot of 1α,25(OH)2D3 needs consideration. We urge caution in interpreting serum vitamin D in critically ill patients in the context of major resuscitation, and would advocate repeating the measurement once the effects of the resuscitation have abated.
Resumo:
Multimetric ecological condition assessment has become an important biodiversity management tool. This study was the first to examine the reliability of these ecological surrogates across variable environments, and the implications for surrogate efficacy. It was demonstrated that through strategic application and design of the multimetric ecological condition index, the effects of environmental gradients and disturbance regimes can be mitigated, and that ecological condition assessment may serve as a scientifically rigorous approach for conservation planning.