69 resultados para pump station


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Busway stations are the interface between passengers and services. The station is crucial to line operation as it is typically the only location where buses can pass each other. Congestion may occur here when buses manoeuvring into and out of the platform lane interfere with bus flow, or when a queue of buses forms upstream of the platform lane blocking the passing lane. Further, some systems include operation where express buses do not observe the station, resulting in a proportion of non-stopping buses. It is important to understand the operation of the station under this type of operation and its effect on busway capacity. This study uses microscopic simulation to treat the busway station operation and to analyse the relationship between station potential capacity where all buses stop, and Mixed Potential Capacity where there is a mixture of stopping and non-stopping buses. First, the micro simulation technique is used to analyze the All Stopping Buses (ASB) scenario and then statistical model is tuned and calibrated for a specified range of controlled scenarios of dwell time characteristics Subsequently, a mathematical model is developed for Mixed Stopping Buses (MSB) Potential Capacity by introducing different proportions of express (or non-stopping) buses. The proposed models for a busway station bus capacity provide a better understanding of operation and are useful to transit agencies in busway planning, design and operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties and toxicity of untreatedwastewater at Davis Station, East Antarctica,were investigated to inform decisions regarding the appropriate level of treatment for local discharge purposes and more generally, to better understand the risk associated with dispersal and impact of wastewaters in Antarctica. Suspended solids, nutrients (nitrogen, phosphorus), biological oxygen demand (BOD), metals, organic contaminants, surfactants and microbiological load were measured at various locations throughout the wastewater discharge system. Wastewater quality and properties varied greatly between buildings on station, each ofwhich has separate holding tanks. Nutrients, BOD and settleable solid levelswere higher than standard municipal wastewaters. Microbiological loads were typical of untreated wastewater. Contaminants detected in the wastewater included metals and persistent organic compounds, mainly polybrominated diphenyl ethers (PBDEs). The toxicity of wastewater was also investigated in laboratory bioassays using two local Antarctic marine invertebrates, the amphipod Paramoera walkeri and the microgastropod Skenella paludionoides. Animals were exposed to a range of wastewater concentrations from3% to 68% (test 1) or 63% (test 2) over 21 days with survival monitored daily. Significant mortality occurred in all concentrations of wastewater after 14 to 21 days, and at higher concentrations (50–68% wastewater) mortality occurred after only one day. Results indicate that the local receiving marine environment at Davis Station is at risk from existing wastewater discharges, and that advanced treatment is required both to remove contaminants shown to cause toxicity to biota, as well as to reduce the environmental risks associated with non-native micro-organisms in wastewater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The heavy haul rail network in Queensland Australia generally adopts a lightning impulse withstand voltage rating of 250 kV for the switchgear and autotransformers within its 50 kV ac traction feeder stations. The aging switchgear across a number of feeder stations in this network are undergoing upgrade and the rail network operator is considering the possibility of using 200 kV rating for the upgraded switchgear. This paper investigates the lightning over-voltages that could occur at the feeder stations under review. Fast front transient models of the feeder stations and the associated traction corridors are developed in PSCAD/EMTDC software. Simulations are conducted to evaluate the likely over-voltages under various scenarios and the results are presented. Finally, the required lightning impulse withstand voltage rating for the switchgear is determined based on the simulation results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stations on Bus Rapid Transit (BRT) lines ordinarily control line capacity because they act as bottlenecks. At stations with passing lanes, congestion may occur when buses maneuvering into and out of the platform stopping lane interfere with bus flow, or when a queue of buses forms upstream of the station blocking inflow. We contend that, as bus inflow to the station area approaches capacity, queuing will become excessive in a manner similar to operation of a minor movement on an unsignalized intersection. This analogy was used to treat BRT station operation and to analyze the relationship between station queuing and capacity. We conducted microscopic simulation to study and analyze operating characteristics of the station under near steady state conditions through output variables of capacity, degree of saturation and queuing. In the first of two stages, a mathematical model was developed for all stopping buses potential capacity with bus to bus interference and the model was validated. Secondly, a mathematical model was developed to estimate the relationship between average queue and degree of saturation and calibrated for a specified range of controlled scenarios of mean and coefficient of variation of dwell time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design Proposal for the Blue Lunar Support Hub The conceptual design of a space station is one of the most challenging tasks in aerospace engineering. The history of the space station Mir and the assembly of the International Space Station demonstrate that even within the assembly phase quick solutions have to be found to cope with budget and technical problems or changing objectives. This report is the outcome of the conceptual design of the Space Station Design Workshop (SSDW) 2007, which took place as an international design project from the 16th to the 21st of July 2007 at the Australian Centre for Field Robotics (ACFR), University of Sydney, Australia. The participants were tasked to design a human-tended space station in low lunar orbit (LLO) focusing on supporting future missions to the moon in a programmatic context of space exploration beyond low Earth orbit (LEO). The design included incorporating elements from systems engineering to interior architecture. The customised, intuitive, rapid-turnaround software tools enabled the team to successfully tackle the complex problem of conceptual design of crewed space systems. A strong emphasis was put on improving the integration of the human crew, as it is the major contributor to mission success, while always respecting the boundary conditions imposed by the challenging environment of space. This report documents the methodology, tools and outcomes of the Space Station Design Workshop during the SSDW 2007. The design results produced by Team Blue are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computational fluid dynamics (CFD) and particle image velocimetry (PIV) are commonly used techniques to evaluate the flow characteristics in the development stage of blood pumps. CFD technique allows rapid change to pump parameters to optimize the pump performance without having to construct a costly prototype model. These techniques are used in the construction of a bi-ventricular assist device (BVAD) which combines the functions of LVAD and RVAD in a compact unit. The BVAD construction consists of two separate chambers with similar impellers, volutes, inlet and output sections. To achieve the required flow characteristics of an average flow rate of 5 l/min and different pressure heads (left – 100mmHg and right – 20mmHg), the impellers were set at different rotating speeds. From the CFD results, a six-blade impeller design was adopted for the development of the BVAD. It was also observed that the fluid can flow smoothly through the pump with minimum shear stress and area of stagnation which are related to haemolysis and thrombosis. Based on the compatible Reynolds number the flow through the model was calculated for the left and the right pumps. As it was not possible to have both the left and right chambers in the experimental model, the left and right pumps were tested separately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates a pilot desalination system which consists of a direct expansion solar assisted heat pump (DXSAHP) coupled to a single-effect evaporator unit. The working fluid used is R134a and distillate is obtained via falling film evaporation and flashing in the unit. Experiments have been conducted in both day and night meteorological conditions in Singapore and the effects of solar irradiation and compressor speed have been studied against the system performance. From the experiments, the Performance Ratio (PR) obtained ranges from 0.43 to 0.88, the average Coefficient of Performance (COP) was 8 and the highest distillate production recorded was 1.38 kg/h

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To examine the trends in the prescribing of subsidised proton pump inhibitors (PPIs) and histamine receptor antagonists (H2RAs), in the Australian population from 1995 to 2006 to encourage discussion regarding appropriate clinical use. PPIs and H2RAs are the second highest drug cost to the publicly subsidised Pharmaceutical Benefits Scheme (PBS). Design: Government data on numbers of subsidised scripts, quantity and doses for PPIs and H2RAs were analysed by gender and age, dose and indication. Main outcome measure: Drug utilisation as DDD [defined daily dose]/1000 population/day. Results: The use of combined PPIs increased by 1318%. Utilisation increased substantially after the relaxation of the subsidised indications for PPIs in 2001. Omeprazole had the largest market share but was substituted by its S-enantiomer esomeprazole after its introduction in 2002. There was considerable use in the elderly with the peak use being in those aged 80 years and over. The utilisation of H2RAs declined 72% over 12 years. Conclusions: PPI use has increased substantially, not only due to substitution of H2RAs but to expansion in the overall market. Utilisation does not appear to be commensurate with prevalence of gastro-oesophageal reflux disease (GORD) nor with prescribing guidelines for PPIs, with significant financial costs to patients and PBS. This study encourages clinical discussion regarding quality use of these medicines. © 2010 John Wiley & Sons, Ltd.