86 resultados para attention switching
Resumo:
This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual-inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters, where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption, and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings, together with the inverter practicality, have been confirmed in simulations both using PSIM with Matlab/Simulink coupler and experimentally using a laboratory-implemented inverter prototype.
Resumo:
Hemorrhagic fever with renal syndrome (HFRS), a rodent-borne viral disease characterized by fever, hemorrhagic, kidney damage and hypotension, is caused by different species of hantaviruses [1]. Every year, HFRS affects thousands of people in Asia, and more than 90% of these cases are reported in China [2, 3]. Due to its high fatality, HFRS has attracted considerable research attention, and prior studies have predominantly focused on quantifying HFRS morbidity [4], identifying high risk areas [5] and populations [6], or exploring peak time of HFRS occurrence [3]. To date, no study has assessed the seasonal amplitude of HFRS in China, even though it reveals the seasonal fluctuation and thus may provide pivotal information on the possibility of HFRS outbreaks.
Resumo:
With the rapid development of world-wide wind energy generation using doubly fed induction generations (DFIGs), low voltage ride through (LVRT) has become a great concern. This paper focuses on a unique topology of DFIG called IG connection mode to help the DFIG ride through grid faults smoothly. Transient analysis of IG connection mode is carried out to derive the generator currents. With this analysis, the control strategy for IG connection mode DFIG was developed. From the simulation results, it is clearly visible that IG mode could work in both normal and low grid voltage conditions. Simulation results clearly show that the DFIG with the proposed mode switching control could smoothly ride through low voltage grid faults while satisfying grid code requirements.
Resumo:
A switching control strategy is proposed for current-fed half-bridge converters. An active switch based voltage doubler circuit at the secondary side of the isolation transformer is used to obtain zero-current-switching at turn-off and zero-voltage-switching at turn-on in the primary side switches of the current-fed half-bridge converter. The operation of the current-fed half-bridge converter with the proposed switching control strategy is explained using the equivalent circuit during each sub-interval of operation. The operation of the current-fed halfbridge converter is simulated using MATLAB/Simpower and PSIM to verify the feasibility of the switching control strategy. Experimental results are provided to validate the converter's operation.
Resumo:
A mode switching doubly fed induction generator (MSDFIG) scheme is proposed for the purpose of achieving low-voltage ride-through for wind turbines. The MSDFIG operates as a doubly fed induction generator (DFIG) under normal condition but upon the detection of a low-voltage incident, the generator is to smoothly transfer to operate under the induction generator mode through the switching in of a set of stator-side crowbar. The MSDFIG automatically reverts back to the DFIG mode when network voltage recovers. A new strategy on the control of the crowbar resistance is included. Analysis shows that the proposed MSDFIG scheme can ride through the complete low-voltage and voltage recovery stages. Effectiveness of the scheme is demonstrated through simulation and experiment studies.
Resumo:
In the vast majority of cases legal representation in mediation can provide many advantages for clients. However, in some, progress can be thwarted when lawyers do not understand the goals of the mediation process and their dispute resolution advocacy role. This article will explore some of the similarities and differences between the knowledge and skills that lawyers can draw upon when representing clients in adversarial court hearings as compared with non-adversarial settings, such as in mediations. One key distinction is the different approaches that legal representatives can use to effectively act in the best interests of clients. This article will highlight how an appreciation of such distinctions can assist lawyers to “switch” hats between their adversarial and non-adversarial roles. In particular, an understanding that the duty to promote the best interests of clients in mediation is consistent with a collaborative and problem-solving approach can greatly assist in the resolution process.
Resumo:
Sleep loss, widespread in today’s society and associated with a number of clinical conditions, has a detrimental effect on a variety of cognitive domains including attention. This study examined the sequelae of sleep deprivation upon BOLD fMRI activation during divided attention. Twelve healthy males completed two randomized sessions; one after 27 h of sleep deprivation and one after a normal night of sleep. During each session, BOLD fMRI was measured while subjects completed a cross-modal divided attention task (visual and auditory). After normal sleep, increased BOLD activation was observed bilaterally in the superior frontal gyrus and the inferior parietal lobe during divided attention performance. Subjects reported feeling significantly more sleepy in the sleep deprivation session, and there was a trend towards poorer divided attention task performance. Sleep deprivation led to a down regulation of activation in the left superior frontal gyrus, possibly reflecting an attenuation of top-down control mechanisms on the attentional system. These findings have implications for understanding the neural correlates of divided attention and the neurofunctional changes that occur in individuals who are sleep deprived.
Resumo:
Double-pulse tests are commonly used as a method for assessing the switching performance of power semiconductor switches in a clamped inductive switching application. Data generated from these tests are typically in the form of sampled waveform data captured using an oscilloscope. In cases where it is of interest to explore a multi-dimensional parameter space and corresponding result space it is necessary to reduce the data into key performance metrics via feature extraction. This paper presents techniques for the extraction of switching performance metrics from sampled double-pulse waveform data. The reported techniques are applied to experimental data from characterisation of a cascode gate drive circuit applied to power MOSFETs.
Resumo:
A switching control strategy is proposed for single and dual inductor current-fed push-pull converters. The proposed switching control strategy can be used with both current-fed push-pull converters with an active voltage doubler rectifier, or active rectifier, in the secondary side of the isolation transformer. The proposed switching control strategy makes turn-on and turn-off processes of the primary side power switches zero-voltage-switching and zero-current-switching respectively. The soft-switching operation of the single and dual inductor push-pull converters, with both types of active rectifier, is explained. Simulation and experimental results are provided to validate soft switching operation of the current-fed push-pull converters with the proposed switching control strategy.
Resumo:
Objective. To test the impact of a theory-based, SMS (text message)-delivered behavioural intervention (Healthy Text) targeting sun protection or skin self-examination behaviours compared to attention-control. Method. Overall, 546 participants aged 18–42 years were randomised using a computer-generated number list to the skin self-examination (N = 176), sun protection (N = 187), or attention-control (N = 183) text messages group. Each group received 21 text messages about their assigned topic over 12 months (12 weekly messages for three months, then monthly messages for the next nine months). Data was collected via telephone survey at baseline, three-, and 12-months across Queensland from January 2012 to August 2013. Results. One year after baseline, the sun protection (mean change 0.12; P = 0.030) and skin self-examination groups (mean change 0.12; P = 0.035) had significantly greater improvement in their sun protection habits (SPH) index compared to the attention-control group (reference mean change 0.02). The increase in the proportion of participants who reported any skin self-examination from baseline to 12 months was significantly greater in the skin self-examination intervention group (103/163; 63%; P < 0.001) than the sun protection (83/173; 48%), or attention-control (65/165; 36%) groups. There was no significant effect of the intervention for participants who self-reported whole-body skin self-examination, sun tanning behaviour, or sunburn behaviours. Conclusion. The Healthy Text intervention was effective in inducing significant improvements in sun protection and any type of skin self-examination behaviours.
Resumo:
A switching control strategy is proposed for single inductor current-fed push-pull converter with a secondary side active voltage doubler rectifier or a voltage rectifier used in photovoltaic (PV) grid interfacing. The proposed switching control strategy helps to turn-on and turn-off the primary side power switches with zero-voltage and zero-current switching. The operation of the push-pull converter is analyzed for two modes of operation. The feasibility of the proposed switching control strategy is validated using simulation and experimental results.
Resumo:
Social media is now an integral part of modern sports broadcasting, which combines old and new media into a redefined and multidimensional experience for fans. The popularity of social media has particular implications for professional women's sports due to this convergence, and may be utilised by organisations to address some of the issues women's sports face from a lack of traditional broadcast coverage. This article discusses Twitter activity surrounding the ANZ Championship netball competition and analyses the ways social media can help transcend the structural challenges that “old” media has placed on professional women's sports.