328 resultados para Vision, Ocular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For robots to operate in human environments they must be able to make their own maps because it is unrealistic to expect a user to enter a map into the robot’s memory; existing floorplans are often incorrect; and human environments tend to change. Traditionally robots have used sonar, infra-red or laser range finders to perform the mapping task. Digital cameras have become very cheap in recent years and they have opened up new possibilities as a sensor for robot perception. Any robot that must interact with humans can reasonably be expected to have a camera for tasks such as face recognition, so it makes sense to also use the camera for navigation. Cameras have advantages over other sensors such as colour information (not available with any other sensor), better immunity to noise (compared to sonar), and not being restricted to operating in a plane (like laser range finders). However, there are disadvantages too, with the principal one being the effect of perspective. This research investigated ways to use a single colour camera as a range sensor to guide an autonomous robot and allow it to build a map of its environment, a process referred to as Simultaneous Localization and Mapping (SLAM). An experimental system was built using a robot controlled via a wireless network connection. Using the on-board camera as the only sensor, the robot successfully explored and mapped indoor office environments. The quality of the resulting maps is comparable to those that have been reported in the literature for sonar or infra-red sensors. Although the maps are not as accurate as ones created with a laser range finder, the solution using a camera is significantly cheaper and is more appropriate for toys and early domestic robots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a method for vision only topological simultaneous localisation and mapping (SLAM). Our approach does not use motion or odometric information but a sequence of colour histograms from visited places. In particular, we address the perceptual aliasing problem which occurs using external observations only in topological navigation. We propose a Bayesian inference method to incrementally build a topological map by inferring spatial relations from the sequence of observations while simultaneously estimating the robot's location. The algorithm aims to build a small map which is consistent with local adjacency information extracted from the sequence measurements. Local adjacency information is incorporated to disambiguate places which otherwise would appear to be the same. Experiments in an indoor environment show that the proposed technique is capable of dealing with perceptual aliasing using visual observations only and successfully performs topological SLAM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Australia, the Queensland fruit fly (B. tryoni), is the most destructive insect pest of horticulture, attacking nearly all fruit and vegetable crops. This project has researched and prototyped a system for monitoring fruit flies so that authorities can be alerted when a fly enters a crop in a more efficient manner than is currently used. This paper presents the idea of our sensor platform design as well as the fruit fly detection and recognition algorithm by using machine vision techniques. Our experiments showed that the designed trap and sensor platform is capable to capture quality fly images, the invasive flies can be successfully detected and the average precision of the Queensland fruit fly recognition is 80% from our experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The proportion of older individuals in the driving population is predicted to increase in the next 50 years. This has important implications for driving safety as abilities which are important for safe driving, such as vision (which accounts for the majority of the sensory input required for driving), processing ability and cognition have been shown to decline with age. The current methods employed for screening older drivers upon re-licensure are also vision based. This study, which investigated social, behavioural and professional aspects involved with older drivers, aimed to determine: (i) if the current visual standards in place for testing upon re-licensure are effective in reducing the older driver fatality rate in Australia; (ii) if the recommended visual standards are actually implemented as part of the testing procedures by Australian optometrists; and (iii) if there are other non-standardised tests which may be better at predicting the on-road incident-risk (including near misses and minor incidents) in older drivers than those tests recommended in the standards. Methods: For the first phase of the study, state-based age- and gender-stratified numbers of older driver fatalities for 2000-2003 were obtained from the Australian Transportation Safety Bureau database. Poisson regression analyses of fatality rates were considered by renewal frequency and jurisdiction (as separate models), adjusting for possible confounding variables of age, gender and year. For the second phase, all practising optometrists in Australia were surveyed on the vision tests they conduct in consultations relating to driving and their knowledge of vision requirements for older drivers. Finally, for the third phase of the study to investigate determinants of on-road incident risk, a stratified random sample of 600 Brisbane residents aged 60 years and were selected and invited to participate using an introductory letter explaining the project requirements. In order to capture the number and type of road incidents which occurred for each participant over 12 months (including near misses and minor incidents), an important component of the prospective research study was the development and validation of a driving diary. The diary was a tool in which incidents that occurred could be logged at that time (or very close in time to which they occurred) and thus, in comparison with relying on participant memory over time, recall bias of incident occurrence was minimised. Association between all visual tests, cognition and scores obtained for non-standard functional tests with retrospective and prospective incident occurrence was investigated. Results: In the first phase,rivers aged 60-69 years had a 33% lower fatality risk (Rate Ratio [RR] = 0.75, 95% CI 0.32-1.77) in states with vision testing upon re-licensure compared with states with no vision testing upon re-licensure, however, because the CIs are wide, crossing 1.00, this result should be regarded with caution. However, overall fatality rates and fatality rates for those aged 70 years and older (RR=1.17, CI 0.64-2.13) did not differ between states with and without license renewal procedures, indicating no apparent benefit in vision testing legislation. For the second phase of the study, nearly all optometrists measured visual acuity (VA) as part of a vision assessment for re-licensing, however, 20% of optometrists did not perform any visual field (VF) testing and only 20% routinely performed automated VF on older drivers, despite the standards for licensing advocating automated VF as part of the vision standard. This demonstrates the need for more effective communication between the policy makers and those responsible for carrying out the standards. It may also indicate that the overall higher driver fatality rate in jurisdictions with vision testing requirements is resultant as the tests recommended by the standards are only partially being conducted by optometrists. Hence a standardised protocol for the screening of older drivers for re-licensure across the nation must be established. The opinions of Australian optometrists with regard to the responsibility of reporting older drivers who fail to meet the licensing standards highlighted the conflict between maintaining patient confidentiality or upholding public safety. Mandatory reporting requirements of those drivers who fail to reach the standards necessary for driving would minimise potential conflict between the patient and their practitioner, and help maintain patient trust and goodwill. The final phase of the PhD program investigated the efficacy of vision, functional and cognitive tests to discriminate between at-risk and safe older drivers. Nearly 80% of the participants experienced an incident of some form over the prospective 12 months, with the total incident rate being 4.65/10 000 km. Sixty-three percent reported having a near miss and 28% had a minor incident. The results from the prospective diary study indicate that the current vision screening tests (VA and VF) used for re-licensure do not accurately predict older drivers who are at increased odds of having an on-road incident. However, the variation in visual measurements of the cohort was narrow, also affecting the results seen with the visual functon questionnaires. Hence a larger cohort with greater variability should be considered for a future study. A slightly lower cognitive level (as measured with the Mini-Mental State Examination [MMSE]) did show an association with incident involvement as did slower reaction time (RT), however the Useful-Field-of-View (UFOV) provided the most compelling results of the study. Cut-off values of UFOV processing (>23.3ms), divided attention (>113ms), selective attention (>258ms) and overall score (moderate/ high/ very high risk) were effective in determining older drivers at increased odds of having any on-road incident and the occurrence of minor incidents. Discussion: The results have shown that for the 60-69 year age-group, there is a potential benefit in testing vision upon licence renewal. However, overall fatality rates and fatality rates for those aged 70 years and older indicated no benefit in vision testing legislation and suggests a need for inclusion of screening tests which better predict on-road incidents. Although VA is routinely performed by Australian optometrists on older drivers renewing their licence, VF is not. Therefore there is a need for a protocol to be developed and administered which would result in standardised methods conducted throughout the nation for the screening of older drivers upon re-licensure. Communication between the community, policy makers and those conducting the protocol should be maximised. By implementing a standardised screening protocol which incorporates a level of mandatory reporting by the practitioner, the ethical dilemma of breaching patient confidentiality would also be resolved. The tests which should be included in this screening protocol, however, cannot solely be ones which have been implemented in the past. In this investigation, RT, MMSE and UFOV were shown to be better determinants of on-road incidents in older drivers than VA and VF, however, as previously mentioned, there was a lack of variability in visual status within the cohort. Nevertheless, it is the recommendation from this investigation, that subject to appropriate sensitivity and specificity being demonstrated in the future using a cohort with wider variation in vision, functional performance and cognition, these tests of cognition and information processing should be added to the current protocol for the screening of older drivers which may be conducted at licensing centres across the nation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal image properties such as contrast and spatial frequency play important roles in the development of normal vision. For example, visual environments comprised solely of low contrast and/or low spatial frequencies induce myopia. The visual image is processed by the retina and it then locally controls eye growth. In terms of the retinal neurotransmitters that link visual stimuli to eye growth, there is strong evidence to suggest involvement of the retinal dopamine (DA) system. For example, effectively increasing retinal DA levels by using DA agonists can suppress the development of form-deprivation myopia (FDM). However, whether visual feedback controls eye growth by modulating retinal DA release, and/or some other factors, is still being elucidated. This thesis is chiefly concerned with the relationship between the dopaminergic system and retinal image properties in eye growth control. More specifically, whether the amount of retinal DA release reduces as the complexity of the image degrades was determined. For example, we investigated whether the level of retinal DA release decreased as image contrast decreased. In addition, the effects of spatial frequency, spatial energy distribution slope, and spatial phase on retinal DA release and eye growth were examined. When chicks were 8-days-old, a cone-lens imaging system was applied monocularly (+30 D, 3.3 cm cone). A short-term treatment period (6 hr) and a longer-term treatment period (4.5 days) were used. The short-term treatment tests for the acute reduction in DA release by the visual stimulus, as is seen with diffusers and lenses, whereas the 4.5 day point tests for reduction in DA release after more prolonged exposure to the visual stimulus. In the contrast study, 1.35 cyc/deg square wave grating targets of 95%, 67%, 45%, 12% or 4.2% contrast were used. Blank (0% contrast) targets were included for comparison. In the spatial frequency study, both sine and square wave grating targets with either 0.017 cyc/deg and 0.13 cyc/deg fundamental spatial frequencies and 95% contrast were used. In the spectral slope study, 30% root-mean-squared (RMS) contrast fractal noise targets with spectral fall-off of 1/f0.5, 1/f and 1/f2 were used. In the spatial alignment study, a structured Maltese cross (MX) target, a structured circular patterned (C) target and the scrambled versions of these two targets (SMX and SC) were used. Each treatment group comprised 6 chicks for ocular biometry (refraction and ocular dimension measurement) and 4 for analysis of retinal DA release. Vitreal dihydroxyphenylacetic acid (DOPAC) was analysed through ion-paired reversed phase high performance liquid chromatography with electrochemical detection (HPLC-ED), as a measure of retinal DA release. For the comparison between retinal DA release and eye growth, large reductions in retinal DA release possibly due to the decreased light level inside the cone-lens imaging system were observed across all treated eyes while only those exposed to low contrast, low spatial frequency sine wave grating, 1/f2, C and SC targets had myopic shifts in refraction. Amongst these treatment groups, no acute effect was observed and longer-term effects were only found in the low contrast and 1/f2 groups. These findings suggest that retinal DA release does not causally link visual stimuli properties to eye growth, and these target induced changes in refractive development are not dependent on the level of retinal DA release. Retinal dopaminergic cells might be affected indirectly via other retinal cells that immediately respond to changes in the image contrast of the retinal image.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To navigate successfully in a previously unexplored environment, a mobile robot must be able to estimate the spatial relationships of the objects of interest accurately. A Simultaneous Localization and Mapping (SLAM) sys- tem employs its sensors to build incrementally a map of its surroundings and to localize itself in the map simultaneously. The aim of this research project is to develop a SLAM system suitable for self propelled household lawnmowers. The proposed bearing-only SLAM system requires only an omnidirec- tional camera and some inexpensive landmarks. The main advantage of an omnidirectional camera is the panoramic view of all the landmarks in the scene. Placing landmarks in a lawn field to define the working domain is much easier and more flexible than installing the perimeter wire required by existing autonomous lawnmowers. The common approach of existing bearing-only SLAM methods relies on a motion model for predicting the robot’s pose and a sensor model for updating the pose. In the motion model, the error on the estimates of object positions is cumulated due mainly to the wheel slippage. Quantifying accu- rately the uncertainty of object positions is a fundamental requirement. In bearing-only SLAM, the Probability Density Function (PDF) of landmark position should be uniform along the observed bearing. Existing methods that approximate the PDF with a Gaussian estimation do not satisfy this uniformity requirement. This thesis introduces both geometric and proba- bilistic methods to address the above problems. The main novel contribu- tions of this thesis are: 1. A bearing-only SLAM method not requiring odometry. The proposed method relies solely on the sensor model (landmark bearings only) without relying on the motion model (odometry). The uncertainty of the estimated landmark positions depends on the vision error only, instead of the combination of both odometry and vision errors. 2. The transformation of the spatial uncertainty of objects. This thesis introduces a novel method for translating the spatial un- certainty of objects estimated from a moving frame attached to the robot into the global frame attached to the static landmarks in the environment. 3. The characterization of an improved PDF for representing landmark position in bearing-only SLAM. The proposed PDF is expressed in polar coordinates, and the marginal probability on range is constrained to be uniform. Compared to the PDF estimated from a mixture of Gaussians, the PDF developed here has far fewer parameters and can be easily adopted in a probabilistic framework, such as a particle filtering system. The main advantages of our proposed bearing-only SLAM system are its lower production cost and flexibility of use. The proposed system can be adopted in other domestic robots as well, such as vacuum cleaners or robotic toys when terrain is essentially 2D.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development and preliminary experimental evaluation of a visionbased docking system to allow an Autonomous Underwater Vehicle (AUV) to identify and attach itself to a set of uniquely identifiable targets. These targets, docking poles, are detected using Haar rectangular features and rotation of integral images. A non-holonomic controller allows the Starbug AUV to orient itself with respect to the target whilst maintaining visual contact during the manoeuvre. Experimental results show the proposed vision system is capable of robustly identifying a pair of docking poles simultaneously in a variety of orientations and lighting conditions. Experiments in an outdoor pool show that this vision system enables the AUV to dock autonomously from a distance of up to 4m with relatively low visibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over recent decades, the flow of television programmes and services between nations has prompted concerns about `Cultural Imperialism', the idea that the powerful metropolitan nations at the centre of the world system are breaking down the integrity and autonomy of the peripheral countries. New Patterns in Global Television challenges that notion by showing that some of the countries outside the traditionally dominant centres have now developed strong television industries of their own, and have been expanding into regional markets, especially - but not exclusively - where linguistic and cultural similarities exist. This book brings together contributions from specialist researchers on the most dynamic of these regions: Latin America, India, the Middle East, Greater China and, in the English-speaking world, Canada and Australia. It provides the first comprehensive overview of the new patterns of flow in international television programme exchange and service provision in the satellite era, patterns unrecognised by the perspective of the prevailing theoretical orthodoxies in international communication research and policy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the limits at which blur due to defocus, crossed-cylinder astigmatism, and trefoil became noticeable, troublesome or objectionable. Black letter targets (0.1, 0.35 and 0.6 logMAR) were presented on white backgrounds. Subjects were cyclopleged and had effectively 5 mm pupils. Blur was induced with a deformable, adaptive-optics mirror operating under open-loop conditions. Mean defocus blur limits of six subjects with uncorrected intrinsic higher-order ocular aberrations ranged from 0.18 ± 0.08 D (noticeable blur criterion, 0.1 logMAR) to 1.01 ± 0.27 D (objectionable blur criterion, 0.6 logMAR. Crossed-cylinder astigmatic blur limits were approximately 90% of those for defocus, but with considerable meridional influences. In two of the subjects, the intrinsic aberrations of the eye were subsequently corrected before the defocus and astigmatic blur were added. This resulted in only minor reductions in their blur limits. When assessed with trefoil blur and corrected intrinsic ocular aberrations, the ratio of objectionable to noticeable blur limits in these two subjects was much higher for trefoil (3.5) than for defocus (2.5) and astigmatism (2.2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine (a) the effect of different sunglass tint colorations on traffic signal detection and recognition for color normal and color deficient observers, and (b) the adequacy of coloration requirements in current sunglass standards. Methods: Twenty color-normals and 49 color-deficient males performed a tracking task while wearing sunglasses of different colorations (clear, gray, green, yellow-green, yellow-brown, red-brown). At random intervals, simulated traffic light signals were presented against a white background at 5° to the right or left and observers were instructed to identify signal color (red/yellow/green) by pressing a response button as quickly as possible; response times and response errors were recorded. Results: Signal color and sunglass tint had significant effects on response times and error rates (p < 0.05), with significant between-color group differences and interaction effects. Response times for color deficient people were considerably slower than color normals for both red and yellow signals for all sunglass tints, but for green signals they were only noticeably slower with the green and yellow-green lenses. For most of the color deficient groups, there were recognition errors for yellow signals combined with the yellow-green and green tints. In addition, deuteranopes had problems for red signals combined with red-brown and yellow-brown tints, and protanopes had problems for green signals combined with the green tint and for red signals combined with the red-brown tint. Conclusions: Many sunglass tints currently permitted for drivers and riders cause a measurable decrement in the ability of color deficient observers to detect and recognize traffic signals. In general, combinations of signals and sunglasses of similar colors are of particular concern. This is prima facie evidence of a risk in the use of these tints for driving and cautions against the relaxation of coloration limits in sunglasses beyond those represented in the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of orthokeratology on peripheral aberrations in two myopic volunteers. Methods: The subjects wore reverse geometry orthokeratology lenses overnight and were monitored for 2 weeks of wear. They underwent corneal topography, peripheral refraction (out to ±34° along the horizontal visual field) and peripheral aberration measurements across the 42° × 32° central visual field using a modified Hartmann-Shack aberrometer. Results: Spherical equivalent refraction was corrected for the central 25° of the visual fields beyond which it gradually returned to its preorthokeratology values. There were increases in axial coma, spherical aberration, higher order root mean square aberrations, and total root-mean-squared aberrations (excluding defocus). The rates of change of vertical and horizontal coma across the field changed in sign. Total root mean square aberrations showed a quadratic rate of change across the visual field which was greater subsequent to orthokeratology. Conclusion: Although orthokeratology can correct peripheral relative hypermetropia it induces dramatic increases in higher-order aberrations across the field

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: As the population ages, more people will be wearing presbyopic vision corrections when driving. However, little is known about the impact of these vision corrections on driving performance. This study aimed to determine the subjective driving difficulties experienced when wearing a range of common presbyopic contact lens and spectacle corrections.----- Methods: A questionnaire was developed and piloted that included a series of items regarding difficulties experienced while driving under daytime and night-time conditions (rated on five-point and seven-point Likert scales). Participants included 255 presbyopic patients recruited through local optometry practices. Participants were categorized into five age-matched groups; including those wearing no vision correction for driving (n = 50), bifocal spectacles (n = 54), progressive spectacles (n = 50), monovision contact lenses (n = 53), and multifocal contact lenses (n = 48).----- Results: Overall, ratings of satisfaction during daytime driving were relatively high for all correction types. However, multifocal contact lens wearers were significantly less satisfied with aspects of their vision during night-time than daytime driving, particularly regarding disturbances from glare and haloes. Progressive spectacle lens wearers noticed more distortion of peripheral vision, whereas bifocal spectacle wearers reported more difficulties with tasks requiring changes of focus and those who wore no optical correction for driving reported problems with intermediate and near tasks. Overall, satisfaction was significantly higher for progressive spectacles than bifocal spectacles for driving.----- Conclusions: Subjective visual experiences of different presbyopic vision corrections when driving vary depending on the vision tasks and lighting level. Eye-care practitioners should be aware of the driving-related difficulties experienced with each vision correction type and the need to select corrective types that match the driving needs of their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The care of low-vision patients is termed vision rehabilitation, and optometrists have an essential role to play in the provision of vision rehabilitation services. Ideally, if patients stay with one optometrist or practice, their low-vision care becomes part of a continuum of eye care, from the time when they had normal vision. If progressive vision loss occurs, the role of the optometrist changes from primary eye care only to one of monitoring vision loss and gradually introducing low-vision care, especially magnification and advice on lighting and contrast, in conjunction with other vision rehabilitation professionals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. ----- Methods: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3-7 hours over a 24-hour period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analysed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Intraocular pressure and axial length were also measured at each measurement session. Repeated measures ANOVA were used to investigate diurnal change in these parameters. Analysis of covariance was used to examine associations between the measured ocular parameters. ----- Results: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180° at this time. A significant swelling of the cornea (p < 0.0001) was also found to occur immediately after waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. ----- Conclusions: Significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea were typically evident upon waking. The observed non-uniform regional corneal thickness changes resulted in a steepening of the posterior cornea, and a flattening of the anterior cornea to occur at this time.