72 resultados para TASTE SENSORS
Resumo:
A field oriented control (FOC) algorithm is simulated and implemented for use with a permanent magnet synchronous motor (PMSM). Rotor position is sensed using Hall effect switches on the stator because other hardware position sensors attached to the rotor may not be desirable or cost effective for certain applications. This places a limit on the resolution of position sensing – only a few Hall effect switches can be placed. In this simulation, three sensors are used and the position information is obtained at higher resolution by estimating it from the rotor dynamics, as shown in literature previously. This study compares the performance of the method with an incremental encoder using simulations. The FOC algorithm is implemented using Digital Motor Control (DMC) and IQ Texas Instruments libraries from a Simulink toolbox called Embedded Coder, and downloaded into a TI microcontroller (TMS320F28335) known as the Piccolo via Code Composer Studio (CCS).
Resumo:
This paper describes the fabrication of thin films of porphyrin and metallophthalocyanine derivatives on different substrates for the optochemical detection of HCl gas and electrochemical determination of L-cysteine (CySH). Solid state gas sensor for HCl gas was fabricated by coating meso-substituted porphyrin derivatives on glass slide and examined optochemical sensing of HCl gas. The concentration of gaseous HCl was monitored from the changes in the absorbance of Soret band. Among the different porphyrin derivatives, meso- tetramesitylporphyrin (MTMP) coated film showed excellent sensitivity towards HCl and achieved a detection limit of 0.03ppm HCl. Further, we have studied the self-assembly of 1,8,15,22-tetraaminometallophthalocyanine (4α-MTAPc; M = Co and Ni) from DMF on GC electrode. The CVs for the self-assembled monolayers (SAMs) of 4α-CoIITAPc and 4α-NiIITAPc show two pairs of well-defined redox couple corresponding to metal and ring. Using the 4α-CoIITAPc SAM modified electrode, sensitive and selective detection of L-cysteine was demonstrated. Further, the SAM modified electrode also successfully separates the oxidation potentials of AA and CySH with a peak separation of 320mV.
Resumo:
A simple modular strategy for the synthesis of profluorescent nitroxide containing polymers is described. The incorporation of an epoxide as a pendant functionality on a polymer backbone synthesized using ATRP and subsequent nucleophilic ring-opening with sodium azide gave hydroxyl and azide functionality within a 3-bond radius. Orthogonal coupling chemistry then allowed the independent attachment of fluorophore and nitroxide groups in close proximity, giving rise to a profluorescent polymer. Validation of the viability of these materials as fluorescent sensors is demonstrated through efficient fluorescence switch-on observed when the materials are exposed to a model reductant or carbon-centred radical source.
Resumo:
Background Balance dysfunction is one of the most common problems in people who suffer stroke. To parameterize functional tests standardized by inertial sensors have been promoted in applied medicine. The aim of this study was to compare the kinematic variables of the Functional Reach Test (FRT) obtained by two inertial sensors placed on the trunk and lumbar region between stroke survivors (SS) and healthy older adults (HOA) and to analyze the reliability of the kinematic measurements obtained. Methods Cross-sectional study. Five SS and five HOA over 65. A descriptive analysis of the average range as well as all kinematic variables recorded was developed. The intrasubject and intersubject reliability of the measured variables was directly calculated. Results In the same intervals, the angular displacement was greater in the HOA group; however, they were completed at similar times for both groups, and HOA conducted the test at a higher speed and greater acceleration in each of the intervals. The SS values were higher than HOA values in the maximum and minimum acceleration in the trunk and in the lumbar region. Conclusions The SS show less functional reach, a narrower, slower and less accelerated movement during the FRT execution, but with higher peaks of acceleration and speed when they are compared with HOA.
Resumo:
Smell (olfactory) and taste (gustatory) are key senses in the regulation of nourishment and individual safety. Olfactory and gustatory dysfunctions have been infrequently reported together in patients following stroke (Landis et al., 2006; Leopold et al., 2006). This case report details two patients who experienced smell and taste dysfunction following minor stroke events. Symptoms reported included hyposmia (diminished sense of smell) and anosmia (complete loss of smell), and dysgeusia (distorted taste). Patients' sense of smell and taste were assessed in an ambulatory care stroke prevention clinic eight months following their strokes. Patient A presented with minor stroke due to a lesion in the anterior circulation, patient B with a lesion in the posterior circulation. Both patients reported intense olfactory and gustatory dysfunction immediately following their strokes. Examination revealed a general inability to detect subtle odours and the ability to identify only 'sweet' tastes for both patients. In addition, both patients reported heavily salting or sweetening their food to mask the distorted and unpleasant taste, which also impacted comorbid conditions such as hypertension and diabetes. Patients and their spouses reported a decrease in their appreciation of family-related activities due to the patients' olfactory and gustatory dysfunction. Patients reported weight loss, lack of energy and strength, likely due to poor nutrition. Olfactory and gustatory dysfunctions are potentially deleterious outcomes following minor stroke and should be assessed by health care professionals prior to patient discharge. Assistance may be required to promote the health and well-being of patients and their carers if smell and taste are impacted by the stroke event.
Resumo:
This paper discusses some of the sensing technologies and control approaches available for guiding robot manipulators for a class of underground mining tasks including drilling jumbos, bolting arms, shotcreters or explosive chargers. Data acquired with such sensors, in the laboratory and underground, is presented.
Resumo:
This paper asks the question to what scale and speed does society need to reduce its ecological footprint and improve resource productivity to prevent further overshoot and return within the ecological limits of the earth’s ecological life support systems? How fast do these changes need to be achieved? The paper shows that now a large range of studies find that engineering sustainable solutions need to be roughly an order or magnitude resource productivity improvement (sometimes called a Factor of 10, or a 90% reduction) by 2050 to achieve real and lasting ecological sustainability. This marks a significant challenge for engineers – indeed all designers and architects, where best practice in engineering sustainable solutions will need to achieve large resource productivity targets. The paper brings together examples of best practice in achieving these large targets from around the world. The paper also highlights key resources and texts for engineers who wish to learn how to do it. But engineers need to be realistic and patient. Significant barriers exist to achieving Factor 4-10 such as the fact that infrastructure and technology rollover and replacement is often slow. This slow rollover of the built environment and technology is the context within which most engineers work, making the goal of achieving Factor 10 all the more challenging. However, the paper demonstrates that by using best practice in engineering sustainable solutions and by addressing the necessary market, information and institutional failures it is possible to achieve Factor 10 over the next 50 years. This paper draws on recent publications by The Natural Edge Project (TNEP) and partners, including Hargroves, K. Smith, M. (Eds) (2005) The Natural Advantage of Nations: Business Opportunities, Innovation and Governance for the 21st Century, and the TNEP Engineering Sustainable Solutions Program - Critical Literacies for Engineers Portfolio. Both projects have the significant support of Engineers Australia. its College of Environmental Engineers and the Society of Sustainability and Environmental Engineering.
Resumo:
Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.
Development of multi-rotor localised surveillance using multi-spectral sensors for plant biosecurity
Resumo:
This report describes a proof of concept for multi-rotor localised surveillance using a multi-spectral sensor for plant biosecurity applications. A literature review was conducted on previous applications using airborne multispectral imaging for plant biosecurity purposes. A ready built platform was purchased and modified in order to fit and provide suitable clearance for a Tetracam Mini-MCA multispectral camera. The appropriate risk management documents were developed allowing the platform and the multi-spectral camera to be tested extensively. However, due to technical difficulties with the platform the Mini- MCA was not mounted to the platform. Once a suitable platform is developed, future extensions can be conducted into the suitability of the Mini-MCA for airborne surveillance of Australian crops.
Resumo:
A biocompatible method for fabricating three-dimensional photonic crystals opens up unique opportunities for structurally coloured biodegradable materials, but also for implantable biosensing and targeted therapeutics on the microscale.
Resumo:
For the first time, we have fabricated and tested conductometric sensors based on oxidized liquid galinstan towards NO2 and NH3 gases at low operating temperatures. Galinstan based films on silicon substrates have been studied with two different loadings. Surface morphology of the films was investigated by means of field emission scanning electron microscopy (FESEM). The sensor with higher galinstan loading showed a better sensitivity, which can be attributed to a higher surface area, as confirmed by SEM. At 100°C, a detection limit as low as 1 and 20 ppm was measured for NO2 and NH3, respectively.
Resumo:
Consumer driven food trends are nothing new. “Organics”, gluten-free, and more recently buying “local” have all captured consumers, encouraging supermarkets around the globe and in Australia to respond. But the next emerging European food trend that may have the biggest impact on what we buy each week is “ugly food”.