85 resultados para Planar auto-calibration
Resumo:
Background The purposes of this study were 1) to establish accelerometer count cutoffs to categorize activity intensity of 3 to 5-y old-children and 2) to evaluate the accelerometer as a measure of children’s physical activity in preschool settings. Methods While wearing an ActiGraph accelerometer, 16 preschool children performed five, 3-min structured activities. Receiver Operating Characteristic (ROC) curve analyses identified count cutoffs for four physical activity intensities. In 9 preschools, 281 children wore an ActiGraph during observations performed by three trained observers (interobserver reli-ability = 0.91 to 0.98). Results Separate count cutoffs for 3, 4, and 5-y olds were established. Sensitivity and specificity for the count cutoffs ranged from 86.7% to 100.0% and 66.7% to 100.0%, respectively. ActiGraph counts/15 s were different among all activities (P < 0.05) except the two sitting activities. Correlations between observed and ActiGraph intensity categorizations at the preschools ranged from 0.46 to 0.70 (P < 0.001). Conclusions The ActiGraph count cutoffs established and validated in this study can be used to objectively categorize the time that preschool-age children spend in different physical activity intensity levels.
Resumo:
Objective The present study aimed to develop accelerometer cut points to classify physical activities (PA) by intensity in preschoolers and to investigate discrepancies in PA levels when applying various accelerometer cut points. Methods To calibrate the accelerometer, 18 preschoolers (5.8 +/- 0.4 years) performed eleven structured activities and one free play session while wearing a GT1M ActiGraph accelerometer using 15 s epochs. The structured activities were chosen based on the direct observation system Children's Activity Rating Scale (CARS) while the criterion measure of PA intensity during free play was provided using a second-by-second observation protocol (modified CARS). Receiver Operating Characteristic (ROC) curve analyses were used to determine the accelerometer cut points. To examine the classification differences, accelerometer data of four consecutive days from 114 preschoolers (5.5 +/- 0.3 years) were classified by intensity according to previously published and the newly developed accelerometer cut points. Differences in predicted PA levels were evaluated using repeated measures ANOVA and Chi Square test. Results Cut points were identified at 373 counts/15 s for light (sensitivity: 86%; specificity: 91%; Area under ROC curve: 0.95), 585 counts/15 s for moderate (87%; 82%; 0.91) and 881 counts/15 s for vigorous PA (88%; 91%; 0.94). Further, applying various accelerometer cut points to the same data resulted in statistically and biologically significant differences in PA. Conclusions Accelerometer cut points were developed with good discriminatory power for differentiating between PA levels in preschoolers and the choice of accelerometer cut points can result in large discrepancies.
Resumo:
Current-voltage characteristics of the planar magnetron are studied experimentally and by numerical simulation. Based on the measured current-voltage characteristics, a model of the planar magnetron discharge is developed with the background gas pressure and magnetic field used as parameters. The discharge pressure was varied in a range of 0.7-1.7 Pa, the magnetic field of the magnetron was of 0.033-0.12 T near the cathode surface, the discharge current was from 1 to 25 A, and the magnetic field lines were tangential to the substrate surface in the region of the magnetron discharge ignition. The discharge model describes the motion of energetic secondary electrons that gain energy by passing the cathode sheath across the magnetic field, and the power required to sustain the plasma generation in the bulk. The plasma electrons, in turn, are accelerated in the electric field and ionize effectively the background gas species. The model is based on the assumption about the prevailing Bohm mechanism of electron conductivity across the magnetic field. A criterion of the self-sustained discharge ignition is used to establish the dependence of the discharge voltage on the discharge current. The dependence of the background gas density on the current is also observed from the experiment. The model is consistent with the experimental results. © 2010 American Institute of Physics.
Resumo:
The effect of charged particulates or dusts on surface wave produced microwave discharges is studied. The frequencies of the standing electromagnetic eigenmodes of large-area flat plasmas are calculated. The dusts absorb a significant amount of the plasma electrons and can lead to a modification of the electromagnetic field structure in the discharge by shifting the originally excited operating mode out of resonance. For certain given proportions of dusts, mode conversion is found to be possible. The power loss in the discharge is also increased because of dust-specific dissipations, leading to a decrease of the operating mode quality factor.
Resumo:
Parameters of a discharge sustained in a planar magnetron configuration with crossed electric and magnetic fields are studied experimentally and numerically. By comparing the data obtained in the experiment with the results of calculations made using the proposed theoretical model, conclusion was made about the leading role of the turbulence-driven Bohm electron conductivity in the low-pressure operation mode (up to 1 Pa) of the discharge in crossed electric and magnetic fields. A strong dependence of the width of the cathode sputter trench, associated with the ionization region of the magnetron discharge, on the discharge parameters was observed in the experiments. The experimental data were used as input parameters in the discharge model that describes the motion of secondary electrons across the magnetic field in the ionization region and takes into account the classical, near-wall, and Bohm mechanisms of electron conductivity.
Resumo:
A theoretical model of a large-area planar plasma producer based on surface wave (SW) propagation in a plasma-metal structure with a dielectric sheath is presented. The SW which produces and sustains the microwave gas discharge in the planar structure propagates along an external magnetic field and possesses an eigenfrequency within the range between electron cyclotron and electron plasma frequencies. The spatial distributions of the produced plasma density, electromagnetic fields, energy flow density, phase velocity and reverse skin depth of the SW are obtained analytically and numerically.
Resumo:
The self-modulation process of a high-frequency surface wave (SW) in a wave-guiding structure - a semibounded magnetoactive plasma and perfectly conducting metal wall - is considered for the weak nonlinearity approximation. Estimates are given for the contributions to the nonlinear frequency shift of the SW from the two principal self-action channels: via the generation of a signal of the doubled frequency and of static surface perturbations, arising as the result of the action of a ponderomotive force. Solutions for the field envelope of the nonlinear wave are examined with regard to their stability with respect to longitudinal and transverse perturbations.
Resumo:
The nonlinear effect of hf surface waves self-interaction in a magnetoactive planar plasma waveguide is studies. The waveguide structure under consideration can be formed by gaseous or semiconducting homogeneous plasma, which is limited by a perfectly conducting metal surface. The surface (localized near the surface) wave perturbations propagating on the plasma-metal boundary perpendicular to the constant external magnetic field, are investigated. The nonlinear frequency shift connected with interaction of the second harmonic and static surface perturbations with the main frequency wave, is determined using the approximation of weak nonlinearity. It is shown that the process of double-frequency signal generation is the dissipative one as a result of bulk wave excitation on the surface wave second harmonic.
Resumo:
In this work we test the feasibility of a new calibration method for gel dosimetry. We examine, through Monte Carlo modelling, whether the inclusion of an organic plastic scintillator system at key points within the gel phantom would perturb the dose map. Such a system would remove the requirement for a separate calibration gel, removing many sources of uncertainty.
Resumo:
Put Britney Spears into a YouTube search and the third auto-fill on the list is “Britney Spears without Autotune”. Auto-Tune has become the music industry equivalent of doping in the Tour de France circa 2005; we know everyone’s doing it, but we still have a sense of surprise and outrage when it becomes public. In the last week or so a video has surfaced of the pop singer Britney Spears – with examples of her vocal before and after processing. Whether or not the “before” version is actually the raw material for the “after” version is difficult to say. What’s not difficult to say is that the “before” vocal is distinctly lacking in a demonstrable ability to sing in tune.
Resumo:
Intensity Modulated Radiotherapy (IMRT) is a well established technique for delivering highly conformal radiation dose distributions. The complexity of the delivery techniques and high dose gradients around the target volume make verification of the patient treatment crucial to the success of the treatment. Conventional treatment protocols involve imaging the patient prior to treatment, comparing the patient set-up to the planned set-up and then making any necessary shifts in the patient position to ensure target volume coverage. This paper presents a method for calibrating electronic portal imaging device (EPID) images acquired during IMRT delivery so that they can be used for verifying the patient set-up.
Resumo:
Summary form only given. Geometric simplicity, efficiency and polarization purity make slot antenna arrays ideal solutions for many radar, communications and navigation applications, especially when high power, light weight and limited scan volume are priorities. Resonant arrays of longitudinal slots have a slot spacing of one-half guide wavelength at the design frequency, so that the slots are located at the standing wave peaks. Planar arrays are implemented using a number of rectangular waveguides (branch line guides), arranged side-by-side, while waveguides main lines located behind and at right angles to the branch lines excite the radiating waveguides via centered-inclined coupling slots. Planar slotted waveguide arrays radiate broadside beams and all radiators are designed to be in phase.
Resumo:
The importance of firms’ adaptation processes is prominent in today’s business environment which is characterised by ever changing customers, technologies, and competition. Ever since Schumpeter’s (1942) classic work strategic renewal has been found crucial for firms’ adaptation to environmental change. The role of strategic renewal in firms’ adaptation processes includes development of capabilities for the purpose of sustainability of competitive advantage against environmental changes.