185 resultados para Correlative imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

HRTEM has been used to examine illite/smectite from the Mancos shale, rectorite from Garland County, Arkansas; illite from Silver Hill, Montana; Na-smectite from Crook County, Wyoming; corrensite from Packwood, Washington; and diagenetic chlorite from the Tuscaloosa formation. Thin specimens were prepared by ion milling, ultra-microtome sectioning and/or grain dispersal on a porous carbon substrate. Some smectite-bearing clays were also examined after intercalation with dodecylamine hydrochloride (DH). Intercalation of smectite with DH proved to be a reliable method of HRTEM imaging of expanded smectite, d(001) 16 A which could then be distinguished from unexpanded illite, d(001) 10 A. Lattice fringes of basal spacings of DH-intercalated rectorite and illite/smectite showed 26 A periodicity. These data support XRD studies which suggest that these samples are ordered, interstratified varieties of illite and smectite. The ion-thinned, unexpanded corrensite sample showed discrete crystallites containing 10 A and 14 A basal spacings corresponding with collapsed smectite and chlorite, respectively. Regions containing disordered layers of chlorite and smectite were also noted. Crystallites containing regular alternations of smectite and chlorite were not common. These HRTEM observations of corrensite did not corroborate XRD data. Particle sizes parallel to the c axis ranged widely for each sample studied, and many particles showed basal dimensions equivalent to > five layers. -J.M.H.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As an artist my primary interest is in the abstract, that is in images of the imageless. I am curious about the emergence of pictorial significance and content from this unknowable space. To speak of the significance of an imageless image is also to speak of its affect. I aim to explore this both theoretically and practically. Theoretically I will explore affect through the late work of Lyotard and his notion of the affect-phrase. This is an under-examined aspect of Lyotard and demarcates a valuable way to look at the origins, impact and ramifications of affect for art. Practically I will apply these understandings to the development of my own creative work which includes both painting and digital work. My studio practice moves towards exploring the unfamiliar through the powerful and restless silence of affect.In this intense space each work or body of work 'leaks' into the next occasioning a sense of borderlessness, or of uncertainty. This interpenetration and co-mingling of conceptual and material terrains combines to present temporal and spatial slippages evident within the works themselves and their making, but it is also evident in bodies of work across the chronology of their making. Through a mapping of my own painting and digital arts practice and the utilisation of Lyotard’s notion of the affect -phrase I aim to describe the action of this ‘charged emptiness’ on creativity and explore and explain its significance on that we call image and its animation of what we call critical discourse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two samples of boron carbide have been examined using high resolution transmission electron microscopy (HRTEM). A hot pressed B13C2 sample shows a high density of variable width twins normal to (10-11). Subtle shifts or offsets of lattice fringes along the twin plane and normal to (10 5) were also observed. A B4C powder showed little evidence of stacking disorder in crystalline regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current gold standard for the design of orthopaedic implants is 3D models of long bones obtained using computed tomography (CT). However, high-resolution CT imaging involves high radiation exposure, which limits its use in healthy human volunteers. Magnetic resonance imaging (MRI) is an attractive alternative for the scanning of healthy human volunteers for research purposes. Current limitations of MRI include difficulties of tissue segmentation within joints and long scanning times. In this work, we explore the possibility of overcoming these limitations through the use of MRI scanners operating at a higher field strength. We quantitatively compare the quality of anatomical MR images of long bones obtained at 1.5 T and 3 T and optimise the scanning protocol of 3 T MRI. FLASH images of the right leg of five human volunteers acquired at 1.5 T and 3 T were compared in terms of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The comparison showed a relatively high CNR and SNR at 3 T for most regions of the femur and tibia, with the exception of the distal diaphyseal region of the femur and the mid diaphyseal region of the tibia. This was accompanied by an ~65% increase in the longitudinal spin relaxation time (T1) of the muscle at 3 T compared to 1.5 T. The results suggest that MRI at 3 T may be able to enhance the segmentability and potentially improve the accuracy of 3D anatomical models of long bones, compared to 1.5 T. We discuss how the total imaging times at 3 T can be kept short while maximising the CNR and SNR of the images obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hyperpolarised helium MRI (He3 MRI) is a new technique that enables imaging of the air distribution within the lungs. This allows accurate determination of the ventilation distribution in vivo. The technique has the disadvantages of requiring an expensive helium isotope, complex apparatus and moving the patient to a compatible MRI scanner. Electrical impedance tomography (EIT) a non-invasive bedside technique that allows constant monitoring of lung impedance, which is dependent on changes in air space capacity in the lung. We have used He3MRI measurements of ventilation distribution as the gold standard for assessment of EIT. Methods: Seven rats were ventilated in supine, prone, left and right lateral position with 70% helium/30% oxygen for EIT measurements and pure helium for He3 MRI. The same ventilator and settings were used for both measurements. Image dimensions, geometric centre and global in homogeneity index were calculated. Results: EIT images were smaller and of lower resolution and contained less anatomical detail than those from He3 MRI. However, both methods could measure positional induced changes in lung ventilation, as assessed by the geometric centre. The global in homogeneity index were comparable between the techniques. Conclusion: EIT is a suitable technique for monitoring ventilation distribution and inhomgeneity as assessed by comparison with He3 MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While Magentic Resonance Imaging and Ultrasound are used extensively for non-acute shoulder imaging, plain images are regularly required as a first investigation. This paper presents a snapshot of the diversity of projections performed and a review of the current evidence of the most appropriate projections. The projections recommended are suitable as a first investigation, and also to complement more advanced imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 28. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The precise shape of the three-dimensional dose distributions created by intensity-modulated radiotherapy means that the verification of patient position and setup is crucial to the outcome of the treatment. In this paper, we investigate and compare the use of two different image calibration procedures that allow extraction of patient anatomy from measured electronic portal images of intensity-modulated treatment beams. Methods and Materials: Electronic portal images of the intensity-modulated treatment beam delivered using the dynamic multileaf collimator technique were acquired. The images were formed by measuring a series of frames or segments throughout the delivery of the beams. The frames were then summed to produce an integrated portal image of the delivered beam. Two different methods for calibrating the integrated image were investigated with the aim of removing the intensity modulations of the beam. The first involved a simple point-by-point division of the integrated image by a single calibration image of the intensity-modulated beam delivered to a homogeneous polymethyl methacrylate (PMMA) phantom. The second calibration method is known as the quadratic calibration method and required a series of calibration images of the intensity-modulated beam delivered to different thicknesses of homogeneous PMMA blocks. Measurements were made using two different detector systems: a Varian amorphous silicon flat-panel imager and a Theraview camera-based system. The methods were tested first using a contrast phantom before images were acquired of intensity-modulated radiotherapy treatment delivered to the prostate and pelvic nodes of cancer patients at the Royal Marsden Hospital. Results: The results indicate that the calibration methods can be used to remove the intensity modulations of the beam, making it possible to see the outlines of bony anatomy that could be used for patient position verification. This was shown for both posterior and lateral delivered fields. Conclusions: Very little difference between the two calibration methods was observed, so the simpler division method, requiring only the single extra calibration measurement and much simpler computation, was the favored method. This new method could provide a complementary tool to existing position verification methods, and it has the advantage that it is completely passive, requiring no further dose to the patient and using only the treatment fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of skin temperature (Tsk) in athletic therapy and sports medicine research is an extremely important physiological outcome measure.Various methodsof recording Tsk, including thermistors, thermocouples and thermocrons are currently being used for research purposes. These techniques are constrained by their wires limiting the freedom of the subject, slow response times, and/or sensors falling off. Furthermore, as these products typically are directly attached to the skin and cover the measurement site, their validity may be questionable.This manuscript addresses the use and potential benefits of using thermal imaging (TI) in sport medicine research.Non-contact infrared TI offers a quick, non-invasive, portable and athlete-friendly method of assessing Tsk. TI is a useful Tsk diagnostic tool that has potential to be an integral part of sport medicine research in the future. Furthermore, as the technique is non-contact it has several advantages over existing methods of recording skin temperature

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accuracy of dose delivery in external beam radiotherapy is usually verified with electronic portal imaging (EPI) in which the treatment beam is used to check the positioning of the patient. However the resulting megavoltage x-ray images suffer from poor quality. The image quality can be improved by developing a special operating mode in the linear accelerator. The existing treatment beam is modified such that it produces enough low-energy photons for imaging. In this work the problem of optimizing the beam/detector combination to achieve optimal electronic portal image quality is addressed. The linac used for this study was modified to produce two experimental photon beams. These beams, named Al6 and Al10, were non-flat and were produced by 4MeV electrons hitting aluminum targets, 6 and 10mm thick respectively. The images produced by a conventional EPI system (6MV treatment beam and camera-based EPID with a Cu plate & Gd2O2S screen ) were compared with the images produced by the experimental beams and various screens with the same camera). The contrast of 0.8cm bone equivalent material in 5 cm water increased from 1.5% for the conventional system to 11% for the combination of Al6 beam with a 200mg/cm2 Gd2O2S screen. The signal-to-noise ratio calculated for 1cGy flood field images increased by about a factor of two for the same EPI systems. The spatial resolution of the two imaging systems was comparable. This work demonstrates that significant improvements in portal image contrast can be obtained by simultaneous optimization of the linac spectrum and EPI detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have taken a new method of calibrating portal images of IMRT beams and used this to measure patient set-up accuracy and delivery errors, such as leaf errors and segment intensity errors during treatment. A calibration technique was used to remove the intensity modulations from the images leaving equivalent open field images that show patient anatomy that can be used for verification of the patient position. The images of the treatment beam can also be used to verify the delivery of the beam in terms of multileaf collimator leaf position and dosimetric errors. A series of controlled experiments delivering an IMRT anterior beam to the head and neck of a humanoid phantom were undertaken. A 2mm translation in the position of the phantom could be detected. With intentional introduction of delivery errors into the beam this method allowed us to detect leaf positioning errors of 2mm and variation in monitor units of 1%. The method was then applied to the case of a patient who received IMRT treatment to the larynx and cervical nodes. The anterior IMRT beam was imaged during four fractions and the images calibrated and investigated for the characteristic signs of patient position error and delivery error that were shown in the control experiments. No significant errors were seen. The method of imaging the IMRT beam and calibrating the images to remove the intensity modulations can be a useful tool in verifying both the patient position and the delivery of the beam.