Ventilation distribution in rats : part 2 – a comparison of electrical impedance tomography and hyperpolarised helium magnetic resonance imaging


Autoria(s): Dunster, Kimble R; Friese, Marlies EJ; Fraser, John F; Galloway, Graham J; Cowin, Gary J; Schibler, Andreas
Data(s)

11/09/2012

Resumo

Background: Hyperpolarised helium MRI (He3 MRI) is a new technique that enables imaging of the air distribution within the lungs. This allows accurate determination of the ventilation distribution in vivo. The technique has the disadvantages of requiring an expensive helium isotope, complex apparatus and moving the patient to a compatible MRI scanner. Electrical impedance tomography (EIT) a non-invasive bedside technique that allows constant monitoring of lung impedance, which is dependent on changes in air space capacity in the lung. We have used He3MRI measurements of ventilation distribution as the gold standard for assessment of EIT. Methods: Seven rats were ventilated in supine, prone, left and right lateral position with 70% helium/30% oxygen for EIT measurements and pure helium for He3 MRI. The same ventilator and settings were used for both measurements. Image dimensions, geometric centre and global in homogeneity index were calculated. Results: EIT images were smaller and of lower resolution and contained less anatomical detail than those from He3 MRI. However, both methods could measure positional induced changes in lung ventilation, as assessed by the geometric centre. The global in homogeneity index were comparable between the techniques. Conclusion: EIT is a suitable technique for monitoring ventilation distribution and inhomgeneity as assessed by comparison with He3 MRI.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/58265/

Publicador

BioMed Central Ltd

Relação

http://eprints.qut.edu.au/58265/3/58265P.pdf

DOI:10.1186/1475-925X-11-68

Dunster, Kimble R, Friese, Marlies EJ, Fraser, John F, Galloway, Graham J, Cowin, Gary J, & Schibler, Andreas (2012) Ventilation distribution in rats : part 2 – a comparison of electrical impedance tomography and hyperpolarised helium magnetic resonance imaging. BioMedical Engineering OnLine, 11(1), p. 68.

Direitos

Copyright 2012 Dunster et al.; licensee BioMed Central Ltd

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited

Fonte

School of Chemistry, Physics & Mechanical Engineering; Science & Engineering Faculty

Palavras-Chave #Electrical impedance tomography #Hyperpolarized helium magnetic resonance lmaging #Ventilation distribution #Functional lung imaging