73 resultados para Compositional dependence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The existence of an ecstasy dependence syndrome is controversial. We examined whether the acute after-effects of ecstasy use (i.e., the “come-down”) falsely lead to the identification of ecstasy withdrawal and the subsequent diagnosis of ecstasy dependence. Methods: The Structured Clinical Interview for DSM-IV-TR Disorders: Research Version (SCID-RV) was administered to 214 Australian ecstasy users. Ecstasy withdrawal was operationalized in three contrasting ways: (i) as per DSM-IV criteria; (ii) as the expected after effects of ecstasy (a regular come-down); or (iii) as a substantially greater or longer come-down than on first use (intense come-down). These definitions were validated against frequency of ecstasy use, readiness to change and ability to resist the urge to use ecstasy. Confirmatory factor analyses were used to see how they aligned with the overall dependence syndrome. Results: Come-down symptoms increased the prevalence of withdrawal from 1% (DSM-IV criterion) to 11% (intense come-downs) and 75% (regular come-downs). Past year ecstasy dependence remained at 31% when including the DSM-IV withdrawal criteria and was 32% with intense come-downs, but increased to 45% with regular come-downs. Intense come-downs were associated with lower ability to resist ecstasy use and loaded positively on the dependence syndrome. Regular come-downs did not load positively on the ecstasy dependence syndrome and were not related to other indices of dependence. Conclusion: The acute after-effects of ecstasy should be excluded when assessing ecstasy withdrawal as they can lead to a false diagnosis of ecstasy dependence. Worsening of the ecstasy come-down may be a marker for dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses less recognised factors which influence the diffusion of a particular technology. While an innovation’s attributes and performance are paramount, many fail because of external factors which favour an alternative. This paper, with theoretic input from diffusion, lock-in and path-dependency, presents a qualitative study of external factors that influenced the evolution of transportation in USA. This historical account reveals how one technology and its emergent systems become dominant while other choices are overridden by socio-political, economic and technological interests which include not just the manufacturing and service industries associated with the automobile but also government and market stakeholders. Termed here as a large socio-economic regime (LSER),its power in ensuring lock-in and continued path-dependency is shown to pass through three stages, weakening eventually as awareness improves. The study extends to transport trends in China, Korea, Indonesia and Malaysia and they all show the dominant role of an LSER. As transportation policy is increasingly accountable to address both demand and environmental concerns and innovators search for solutions, this paper presents important knowledge for innovators, marketers and policy makers for commercial and societal reasons, especially when negative externalities associated with an incumbent transportation technology may lead to market failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lipopolysaccharide is a major immunogenic structure for the pathogen Yersinia pseudotuberculosis, which contains the O-specific polysaccharide (OPS) that is presented on the cell surface. The OPS contains many repeats of the oligosaccharide O-unit and exhibits a preferred modal chain length that has been shown to be crucial for cell protection in Yersinia. It is well established that the Wzz protein determines the preferred chain length of the OPS, and in its absence, the polymerization of O units by the Wzy polymerase is uncontrolled. However, for Y. pseudotuberculosis, a wzz mutation has never been described. In this study, we examine the effect of Wzz loss in Y. pseudotuberculosis serotype O:2a and compare the lipopolysaccharide chain-length profile to that of Escherichia coli serotype O111. In the absence of Wzz, the lipopolysaccharides of the two species showed significant differences in Wzy polymerization. Yersinia pseudotuberculosis O:2a exhibited only OPS with very short chain lengths, which is atypical of wzz-mutant phenotypes that have been observed for other species. We hypothesise that the Wzy polymerase of Y. pseudotuberculosis O:2a has a unique default activity in the absence of the Wzz, revealing the requirement of Wzz to drive O-unit polymerization to greater lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we discuss the development of a mathematical model to predict the shift in gas composition observed over time from a producing CSG (coal seam gas) well, and investigate the effect that physical properties of the coal seam have on gas production. A detailed (local) one-dimensional, two-scale mathematical model of a coal seam has been developed. The model describes the competitive adsorption and desorption of three gas species (CH4, CO2 and N2) within a microscopic, porous coal matrix structure. The (diffusive) flux of these gases between the coal matrices (microscale) and a cleat network (macroscale) is accounted for in the model. The cleat network is modelled as a one-dimensional, volume averaged, porous domain that extends radially from a central well. Diffusive and advective transport of the gases occurs within the cleat network, which also contains liquid water that can be advectively transported. The water and gas phases are assumed to be immiscible. The driving force for the advection in the gas and liquid phases is taken to be a pressure gradient with capillarity also accounted for. In addition, the relative permeabilities of the water and gas phases are considered as functions of the degree of water saturation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical coherence tomography (OCT) has been applied for high resolution imaging of articular cartilage. However, the contribution of individual structural elements of cartilage on OCT signal has not been thoroughly studied. We hypothesize that both collagen and chondrocytes, essential structural components of cartilage, act as important light scatterers and that variation in their concentrations can be detected by OCT through changes in backscattering and attenuation. To evaluate this hypothesis, we established a controlled model system using agarose scaffolds embedded with variable collagen concentrations and chondrocyte densities. Using OCT, we measured the backscattering coefficient (µb) and total attenuation coefficient (µt) in these scaffolds. Along our hypothesis, light backscattering and attenuation in agarose were dependent on collagen concentration and chondrocyte density. Significant correlations were found between µt and chondrocyte density (ρ = 0.853, p < 0.001) and between µt and collagen concentration (ρ = 0.694, p < 0.001). µb correlated significantly with chondrocyte density (ρ = 0.504, p < 0.001) but not with collagen concentration (ρ = 0.103, p = 0.422) of the scaffold. Thus, quantitation of light backscattering and, especially, attenuation could be valuable when evaluating the integrity of soft tissues, such as articular cartilage with OCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perceived impaired control over alcohol use is a key cognitive construct in alcohol dependence that has been related prospectively to treatment outcome and may mediate the risk for problem drinking conveyed by impulsivity in non-dependent drinkers. The aim of the current study was to investigate whether perceived impaired control may mediate the association between impulsivity-related measures (derived from the Short-form Eysenck Personality Questionnaire-Revised) and alcohol-dependence severity in alcohol-dependent drinkers. Furthermore, the extent to which this hypothesized relationship was moderated by genetic risk (Taq1A polymorphism in the DRD2/ANKK1 gene cluster) and verbal fluency as an indicator of executive cognitive ability (Controlled Oral Word Association Test) was also examined. A sample of 143 alcohol-dependent inpatients provided an extensive clinical history of their alcohol use, gave 10ml of blood for DNA analysis, and completed self-report measures relating to impulsivity, impaired control and severity of dependence. As hypothesized, perceived impaired control (partially) mediated the association between impulsivity-related measures and alcohol-dependence severity. This relationship was not moderated by the DRD2/ANKK1 polymorphism or verbal fluency. These results suggest that, in alcohol dependence, perceived impaired control is a cognitive mediator of impulsivity-related constructs that may be unaffected by DRD2/ANKK1 and neurocognitive processes underlying the retrieval of verbal information

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computed tomography number to relative electron density (CT-RED) calibration is performed when commissioning a radiotherapy CT scanner by imaging a calibration phantom with inserts of specified RED and recording the CT number displayed. In this work, CT-RED calibrations were generated using several commercially available phantoms to observe the effect of phantom geometry on conversion to electron density and, ultimately, the dose calculation in a treatment planning system. Using an anthropomorphic phantom as a gold standard, the CT number of a material was found to depend strongly on the amount and type of scattering material surrounding the volume of interest, with the largest variation observed for the highest density material tested, cortical bone. Cortical bone gave a maximum CT number difference of 1,110 when a cylindrical insert of diameter 28 mm scanned free in air was compared to that in the form of a 30 × 30 cm2 slab. The effect of using each CT-RED calibration on planned dose to a patient was quantified using a commercially available treatment planning system. When all calibrations were compared to the anthropomorphic calibration, the largest percentage dose difference was 4.2 % which occurred when the CT-RED calibration curve was acquired with heterogeneity inserts removed from the phantom and scanned free in air. The maximum dose difference observed between two dedicated CT-RED phantoms was ±2.1 %. A phantom that is to be used for CT-RED calibrations must have sufficient water equivalent scattering material surrounding the heterogeneous objects that are to be used for calibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd max and to find ways to mitigate this dependence for measurements in phantoms. Methods Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents a novel approach to building large-scale agent-based models of networked physical systems using a compositional approach to provide extensibility and flexibility in building the models and simulations. A software framework (MODAM - MODular Agent-based Model) was implemented for this purpose, and validated through simulations. These simulations allow assessment of the impact of technological change on the electricity distribution network looking at the trajectories of electricity consumption at key locations over many years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ultrasmall superparamagnetic iron oxide (USPIO)-enhanced MRI has been shown to be a useful modality to image activated macrophages in vivo, which are principally responsible for plaque inflammation. This study determined the optimum imaging time-window to detect maximal signal change post-USPIO infusion using T1-weighted (T1w), T2*- weighted (T2*w) and quantitative T2*(qT 2*) imaging. Methods: Six patients with an asymptomatic carotid stenosis underwent high resolution T1w, T2*w and qT2*MR imaging of their carotid arteries at 1.5 T. Imaging was performed before and at 24, 36, 48, 72 and 96 h after USPIO (Sinerem™, Guerbet, France) infusion. Each slice showing atherosclerotic plaque was manually segmented into quadrants and signal changes in each quadrant were fitted to an exponential power function to model the optimum time for post-infusion imaging. Results: The power function determining the mean time to convergence for all patients was 46, 41 and 39 h for the T1w, T 2*w and qT2*sequences, respectively. When modelling each patient individually, 90% of the maximum signal intensity change was observed at 36 h for three, four and six patients on T1w, T 2*w and qT2*, respectively. The rates of signal change decrease after this period but signal change was still evident up to 96 h. Conclusion: This study showed that a suitable imaging window for T 1w, T2*w and qT2*signal changes post-USPIO infusion was between 36 and 48 h. Logistically, this would be convenient in bringing patients back for one post-contrast MRI, but validation is required in a larger cohort of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compositional data analysis usually deals with relative information between parts where the total (abundances, mass, amount, etc.) is unknown or uninformative. This article addresses the question of what to do when the total is known and is of interest. Tools used in this case are reviewed and analysed, in particular the relationship between the positive orthant of D-dimensional real space, the product space of the real line times the D-part simplex, and their Euclidean space structures. The first alternative corresponds to data analysis taking logarithms on each component, and the second one to treat a log-transformed total jointly with a composition describing the distribution of component amounts. Real data about total abundances of phytoplankton in an Australian river motivated the present study and are used for illustration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Stress, craving, and depressed mood have all been implicated in alcohol use treatment lapses. Few studies have examined all 3 factors. Progress has been limited because of difficulties with craving assessment. The Alcohol Craving Experience Questionnaire (ACE) is a new measure of alcohol craving. It is both psychometrically sound and conceptually rigorous. This prospective study examines a stress–treatment response model that incorporates mediation by craving and moderation by depressed mood and pharmacotherapy. Methods Five hundred and thirty-nine consecutively treated alcohol-dependent patients voluntarily participated in an abstinence-based 12-week cognitive-behavioral therapy (CBT) program at a hospital alcohol and drug outpatient clinic. Measures of stress, craving, depressed mood, and alcohol dependence severity were administered prior to treatment. Treatment lapse and treatment dropout were assessed over the 12-week program duration. Results Patients reporting greater stress experienced stronger and more frequent cravings. Stronger alcohol craving predicted lapse, after controlling for dependence severity, stress, depression, and pharmacotherapy. Alcohol craving mediated stress to predict lapse. Depressed mood and anticraving medication were not significant moderators. Conclusions Among treatment seeking, alcohol-dependent patients, craving mediated the relationship between stress and lapse. The effect was not moderated by depressed mood or anticraving medication.