97 resultados para Bioscreen C system
Resumo:
Background: Phase III studies suggest that non-small-cell lung cancer (NSCLC) patients treated with cisplatin-docetaxel may have higher response rates and better survival compared with other platinum-based regimens. We report the final results of a randomised phase III study of docetaxel and carboplatin versus MIC or MVP in patients with advanced NSCLC. Patients and methods: Patients with biopsy proven stage III-IV NSCLC not suitable for curative surgery or radiotherapy were randomised to receive four cycles of either DCb (docetaxel 75 mg/m 2, carboplatin AUC 6), or MIC/MVP (mitomycin 6 mg/m 2, ifosfamide 3 g/m 2 and cisplatin 50 mg/m 2 or mitomycin 6 mg/ m 2, vinblastine 6 mg/m 2 and cisplatin 50 mg/m 2, respectively), 3 weekly. The primary end point was survival, secondary end points included response rates, toxicity and quality of life. Results: The median follow-up was 17.4 months. Overall response rate was 32% for both arms (partial response = 31%, complete response = 1%); 32% of MIC/MVP and 26% of DCb patients had stable disease. One-year survival was 39% and 35% for DCb and MIC/MVP, respectively. Two-year survival was 13% with both arms. Grade 3/4 neutropenia (74% versus 43%, P < 0.005), infection (18% versus 9%, P = 0.01) and mucositis (5% versus 1%, P = 0.02) were more common with DCb than MIC/MVP. The MIC/MVP arm had significant worsening in overall EORTC score and global health status whereas the DCb arm showed no significant change. Conclusions: The combination of DCb had similar efficacy to MIC/MVP but quality of life was better maintained. © 2006 European Society for Medical Oncology.
Resumo:
Microvessel density (MVD) is a widely used surrogate measure of angiogenesis in pathological specimens and tumour models. Measurement of MVD can be achieved by several methods. Automation of counting methods aims to increase the speed, reliability and reproducibility of these techniques. The image analysis system described here enables MVD measurement to be carried out with minimal expense in any reasonably equipped pathology department or laboratory. It is demonstrated that the system translates easily between tumour types which are suitably stained with minimal calibration. The aim of this paper is to offer this technique to a wider field of researchers in angiogenesis.
Resumo:
Background Commercially available instrumented treadmill systems that provide continuous measures of temporospatial gait parameters have recently become available for clinical gait analysis. This study evaluated the level of agreement between temporospatial gait parameters derived from a new instrumented treadmill, which incorporated a capacitance-based pressure array, with those measured by a conventional instrumented walkway (criterion standard). Methods Temporospatial gait parameters were estimated from 39 healthy adults while walking over an instrumented walkway (GAITRite®) and instrumented treadmill system (Zebris) at matched speed. Differences in temporospatial parameters derived from the two systems were evaluated using repeated measures ANOVA models. Pearson-product-moment correlations were used to investigate relationships between variables measured by each system. Agreement was assessed by calculating the bias and 95% limits of agreement. Results All temporospatial parameters measured via the instrumented walkway were significantly different from those obtained from the instrumented treadmill (P < .01). Temporospatial parameters derived from the two systems were highly correlated (r, 0.79–0.95). The 95% limits of agreement for temporal parameters were typically less than ±2% of gait cycle duration. However, 95% limits of agreement for spatial measures were as much as ±5 cm. Conclusions Differences in temporospatial parameters between systems were small but statistically significant and of similar magnitude to changes reported between shod and unshod gait in healthy young adults. Temporospatial parameters derived from an instrumented treadmill, therefore, are not representative of those obtained from an instrumented walkway and should not be interpreted with reference to literature on overground walking.
Resumo:
Background Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within– and between–day repeatability of spatial, temporal and vertical ground reaction forces measured by a treadmill system instrumented with a capacitance–based pressure platform. Methods Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM–THM–S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30–second capture period, equating to an average of 52 ± 5 steps of steady–state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between–session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. Results There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within–day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N. Conclusions The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.
Resumo:
Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.
Resumo:
This article investigates the discourses of academic legitimacy that surround the production, consumption, and accreditation of online scholarship. Using the web-based media and cultural studies journal (http://journal.media-culture.org.au) as a case study, it examines how online scholarly journals often position themselves as occupying a space between the academic and the popular and as having a functional advantage over print-based media in promoting a spirit of public intellectualism. The current research agenda of both government and academe prioritises academic research that is efficient, self-promoting, and relevant to the public. Yet, although the cost-effectiveness and public-intellectual focus of online scholarship speak to these research priorities, online journals such as M/C Journal have occupied, and continue to occupy, an unstable position in relation to the perceived academic legitimacy of their content. Although some online scholarly journals have achieved a limited form of recognition within a system of accreditation that still privileges print-based scholarship, I argue that this, nevertheless, points to the fact that traditional textual notions of legitimate academic work continue to pervade the research agenda of an academe that increasingly promotes flexible delivery of teaching and online research initiatives.
Resumo:
In this paper, an integrated inter-vehicles wireless communications and positioning system supporting alternate positioning techniques is proposed to meet the requirements of safety applications of Cooperative Intelligent Transportation Systems (C-ITS). Recent advances have repeatedly demonstrated that road safety problems can be to a large extent addressed via a range of technologies including wireless communications and positioning in vehicular environments. The novel communication stack utilizing a dedicated frequency spectrum (e.g. at 5.9 GHz band), known as Dedicated Short-Range Communications (DSRC), has been particularly designed for Wireless Access in Vehicular Environments (WAVE) to support safety applications in highly dynamic environments. Global Navigation Satellite Systems (GNSS) is another essential enabler to support safety on rail and roads. Although current vehicle navigation systems such as single frequency Global Positioning System (GPS) receivers can provide route guidance with 5-10 meters (road-level) position accuracy, positioning systems utilized in C-ITS must provide position solutions with lane-level and even in-lane-level accuracies based on the requirements of safety applications. This article reviews the issues and technical approaches that are involved in designing a vehicular safety communications and positioning architecture; it also provides technological solutions to further improve vehicular safety by integrating the DSRC and GNSS-based positioning technologies.
Resumo:
The standard method of labelling proliferating cells uses the thymidine analogue, bromodeoxyuridine (BrdU), which incorporates into the DNA during S-phase of the cell cycle. A disadvantage of this method is that the immunochemical processing requires pre-treatment of the cells and tissue with heat or acid to reveal the antigen. This pre-treatment reduces reliability of the method and degrades the specimen, reducing the ability for multiple immuno-fluorescence labelling at high resolution. We report here the utility of a novel thymidine analogue, ethynyl deoxyuridine (EdU), detected with a fluorescent azide via the “click” chemistry reaction (the Huisgen 1,3-dipolar cycloaddition reaction of an organic azide to a terminal acetylene). The detection of EdU requires no heat or acid treatment and the incorporated EdU is covalently conjugated to fluorescent probe. The reaction is quick and compatible with fluorescence immunochemistry and other fluorescent probes. We show here that EdU is non-toxic in vitro and in vivo and can be used in place of BrdU to label cells during neurogenesis and the progeny identified at least 30 days later. The fluorescent labelling of EdU, markedly improves the detection of proliferating cells and allows concurrent high resolution fluorescence immunochemistry.
Resumo:
High-energy synchrotron in situ X-ray powder diffraction has been used to elucidate the mechanism of the hydriding phase transformation in a LaNi5 model hydrogen storage intermetallic in real time. The transformation proceeds at 10 °C via the transient growth of an interfacial phase, the γ phase, with lattice parameters intermediate between those of the α (dilute solid solution) and β (concentrated hydride) phases. The γ phase forms to partially accommodate the 24% change in unit cell volume between the α and β phases during hydriding and dehydriding. The α, γ and β phases coexist at the nanoscopic level.
Resumo:
Solar cooling systems are gaining popularity due to continuously increasing of energy costs around the world. However, there are still some factors that are hindering the installation of solar cooling systems on a larger scale. One being the cost associated with the solar collectors required to provide heat to the absorption chiller. This study demonstrates the possibility of reducing the number of solar panels in a residential solar cooling system based on evacuated tubes producing hot water at a low temperature (90 °C) and a water-ammonia absorption chiller.
Resumo:
The purpose of this study was to evaluate the validity and inter-rater reliability of the Observation System for Recording Activity in Children: Youth Sports (OSRAC:YS). Children (N=29) participating in a parks and recreation soccer program were observed during regularly scheduled practices. Physical activity (PA) intensity and contextual factors were recorded by momentary time-sampling procedures (10-sec observe, 20-sec record). Two observers simultaneously observed and recorded children's PA intensity, practice context, social context, coach behavior, and coach proximity. Inter-rater reliability was based on agreement (Kappa) between the observer's coding for each category, and the Intraclass Correlation Coefficient (ICC) for percent of time spent in MVPA. Validity was assessed by calculating the correlation between OSRAC:YS estimated and objectively measured MVPA. Kappa statistics for each category demonstrated substantial to almost perfect inter-observer agreement (Κappa = 0.67 to 0.93). The ICC for percent time in MVPA was 0.76 (95% C.I. = 0.49 - 0.90). A significant correlation (r = 0.73) was observed for MVPA recorded by observation and MVPA measured via accelerometry. The results indicate the OSRAC:YS is a reliable and valid tool for measuring children's PA and contextual factors during a youth soccer practice.
Resumo:
This thesis is concerned with understanding the roles of four alternate healing systems and medical practice in the community's health behaviour. The four alternate systems are naturopathy, homoeopathy, osteopathy and chiropractic. The research reported developed from work supported by the Committee of Inquiry into Chiropractic, Osteopathy, Homoeopathy and Naturopathy conducted under the chairmanship of Professor E. C. Webb set up by the Australian Government in 1975. The study concentrates on the factors which influence individual clients in their decisions to consult healers for treatment. An underlying assumption is that an analysis of the processes that effect such decisions will lead to further knowledge of the community's attitudes towards the functions of alternate healing and medicine. A review of the historical backgrounds and current status of the four alternate healing systems leads to the conclusion that they differ in a variety of areas. These areas include treatment modalities, historical backgrounds, occupational development and rapprochement with medicine. Homoeopathy, osteopathy and chiropractic emerged as distinct approaches to healing late in the nineteenth century. Naturopathy tends to be a philosophy or style of life as much as a health system in its own right. Their relationships with medicine also vary; osteopathy and naturopathy receive some acceptance, some homoeopaths are tolerated, whilst chiropractic is ostracised and vilified. A common paradigm of treatment underlies all four alternate approaches to healing. They all eschew the use of synthetic pharmaceuticals and invasive treatments and accept an indigenous theory of disease and a belief in the vis medicatrix naturae or the healing power of nature. An inevitable concomitant of this paradigm is that they believe that healing and health must be self-engendered. They rest within the client and his or her actions, not within the hands, skills or power of the healer. It is these characteristics combined with the alternate healers ' claims to espouse a similar scientific rationale for their approaches, and their functioning as parallel healers to medicine, that establishes their special relationship with medicine. This relationship become s more problematic in the face of medicine's hegemony and claim to unique legitimacy as the community's sole healing system. The interaction between these systems and medical practice can be gauged through articles related to the four alternate healing systems that have appeared in the medical literature. Interest has been cyclical but appears to have markedly increased in the past two decades. In this period it has included exploratory and descriptive writing; concern with controlling and/or eradicating the healers; desire to protect an ignorant and vulnerable public and. finally understanding and exploration of what the alternate healers might have to offer. At the same time, the public or institutionalized role has been one of denial and suppression through ostracism and legal constraints. In spite of medicine's position the alternate healing systems have found growing community acceptance so that it is problematical and probably unacceptable now to consider their use as a 'deviant ' health action. Increasing interest in the characteristics of clients has provided a consensus that they are similar to the adult population and are more likely to suffer from musculoskeletal and chronic illnesses. They are no more likely to be neurotic or gullible than the general community, but probably more practical and more oriented towards an active involvement in the healing process. The impact of these issues is explored, through comparing the strategies taken into account when choosing a treatment. These include attending one of the alternate healers exclusively for a condition; attending an alternate healer and a medical practitioner for the same problem; attending a medical practitioner solely or not consulting any healer. Respondents from surveys of alternate healer clients and the general community were classified according to their use of these four strategies, and the influences on their decisions at different stages of the treatment decision making process were compared.
Resumo:
Efficient hydrogenated diamond-like carbon (DLC) film deposition in a plasma reactor that features both the capacitive and inductively coupled operation regimes is reported. The hydrogenated DLC films have been prepared on silicon wafers using a low-frequency (500 kHz) inductively coupled plasma (LF ICP) chemical vapor deposition (CVD) system. At low RF powers, the system operates as an asymmetric capacitively coupled plasma source, and the film deposition process is undertaken in the electrostatic (E) discharge regime. The films deposited in the electrostatic mode feature graphite-like structure. Above the mode transition threshold, the high-density inductively coupled plasma is produced in the electromagnetic (H) discharge regime. Raman spectrometry suggests the possibility to control relative proportions of sp2 and sp3 hybridized carbon. Variation of the DC substrate bias results in dramatic modification of the film structure from the polymeric (unbiased substrates) to the diamond-like (optimized bias). It has been shown that the deposition rate and hardness of the DLC film are much higher in the H-mode deposition regime. For a 20 m Torr H-mode CH4+Ar gas mixture discharge, the DLC film exhibits mechanical hardness of 18 GPa, Young's modulus of 170 GPa, and compressive stress of 1.3 GPa.
Resumo:
Introduction Intervertebral stapling is a leading method of fusionless scoliosis treatment which attempts to control growth by applying pressure to the convex side of a scoliotic curve in accordance with the Hueter-Volkmann principle. In addition to that, staples have the potential to damage surrounding bone during insertion and subsequent loading. The aim of this study was to assess the extent of bony structural damage including epiphyseal injury as a result of intervertebral stapling using an in vitro bovine model. Materials and Methods Thoracic spines from 6-8 week old calves were dissected and divided into motion segments including levels T4-T11 (n=14). Each segment was potted in polymethylemethacrylate. An Instron Biaxial materials testing machine with a custom made jig was used for testing. The segments were tested in flexion/extension, lateral bending and axial rotation at 37⁰C and 100% humidity, using moment control to a maximum 1.75 Nm with a loading rate of 0.3 Nm per second for 10 cycles. The segments were initially tested uninstrumented with data collected from the tenth load cycle. Next an anterolateral 4-prong Shape Memory Alloy (SMA) staple (Medtronic Sofamor Danek, USA) was inserted into each segment. Biomechanical testing was repeated as before. The staples were cut in half with a diamond saw and carefully removed. Micro-CT scans were performed and sagittal, transverse and coronal reformatted images were produced using ImageJ (NIH, USA).The specimens were divided into 3 grades (0, 1 and 2) according to the number of epiphyses damaged by the staple prongs. Results: There were 9 (65%) segments with grade 1 staple insertions and 5 (35%) segments with grade 2 insertions. There were no grade 0 staples. Grade 2 spines had a higher stiffness level than grade 1 spines, in all axes of movement, by 28% (p=0.004). This was most noted in flexion/extension with an increase of 49% (p=0.042), followed by non-significant change in lateral bending 19% (p=0.129) and axial rotation 8% (p=0.456) stiffness. The cross sectional area of bone destruction from the prongs was only 0.4% larger in the grade 2 group compared to the grade 1 group (p=0.961). Conclusion Intervertebral staples cause epiphyseal damage. There is a difference in stiffness between grade 1 and grade 2 staple insertion segments in flexion/extension only. There is no difference in the cross section of bone destruction as a result of prong insertion and segment motion.