75 resultados para swd: Ray Tracing
Resumo:
We conducted an in-situ X-ray micro-computed tomography heating experiment at the Advanced Photon Source (USA) to dehydrate an unconfined 2.3 mm diameter cylinder of Volterra Gypsum. We used a purpose-built X-ray transparent furnace to heat the sample to 388 K for a total of 310 min to acquire a three-dimensional time-series tomography dataset comprising nine time steps. The voxel size of 2.2 μm3 proved sufficient to pinpoint reaction initiation and the organization of drainage architecture in space and time. We observed that dehydration commences across a narrow front, which propagates from the margins to the centre of the sample in more than four hours. The advance of this front can be fitted with a square-root function, implying that the initiation of the reaction in the sample can be described as a diffusion process. Novel parallelized computer codes allow quantifying the geometry of the porosity and the drainage architecture from the very large tomographic datasets (20483 voxels) in unprecedented detail. We determined position, volume, shape and orientation of each resolvable pore and tracked these properties over the duration of the experiment. We found that the pore-size distribution follows a power law. Pores tend to be anisotropic but rarely crack-shaped and have a preferred orientation, likely controlled by a pre-existing fabric in the sample. With on-going dehydration, pores coalesce into a single interconnected pore cluster that is connected to the surface of the sample cylinder and provides an effective drainage pathway. Our observations can be summarized in a model in which gypsum is stabilized by thermal expansion stresses and locally increased pore fluid pressures until the dehydration front approaches to within about 100 μm. Then, the internal stresses are released and dehydration happens efficiently, resulting in new pore space. Pressure release, the production of pores and the advance of the front are coupled in a feedback loop.
Resumo:
The interactive art system +-NOW captures moments in the past and present for dreamy, reflective play. It is composed of sand, imagery and interaction. This paper traces the creative process from initial landscape studies to museum installation in 2008. Key design concepts discussed include the origin and use of sand and emergence.
Resumo:
Effective flocculation and dewatering of mineral processing streams containing clays are microstructure dependent in clay-water systems. Initial clay flocculation is crucial in the design and for the development of a new methodology of gas exploitation. Microstructural engineering of clay aggregates using covalent cations and Keggin macromolecules have been monitored using the new state of the art Transmission X-ray Microscope (TXM) with 60 nm tomography resolution installed in a Taiwanese synchrotron. The 3-D reconstructions from TXM images show complex aggregation structures in montmorillonite aqueous suspensions after treatment with Na+, Ca2+ and Al13 Keggin macromolecules. Na-montmorillonite displays elongated, parallel, well-orientated and closed-void cellular networks, 0.5–3 μm in diameter. After treatment by covalent cations, the coagulated structure displays much smaller, randomly orientated and openly connected cells, 300–600 nm in diameter. The average distances measured between montmorillonite sheets was around 450 nm, which is less than half of the cell dimension measured in Na-montmorillonite. The most dramatic structural changes were observed after treatment by Al13 Keggin; aggregates then became arranged in compacted domains of a 300 nm average diameter composed of thick face-to-face oriented sheets, which forms porous aggregates with larger intra-aggregate open and connected voids.
Resumo:
The present study examined the historical basis of the Australian disability income support system from 1908 to 2007. Although designed as a safety net for people with a disability, the disability income support system within Australia has been highly targeted. The original eligibility criteria of "permanently incapacitated for work", medical criteria and later "partially capacitated for work" potentially contained ideological inferences that permeated across the time period. This represents an important area for study given the potential consequence for disability income support to marginalise people with a disability. Social policy and disability policy theorists, including Saunders (2007, Social Policy Research Centre [SPRC]) and Gibilisco (2003) have provided valuable insight into some of the effects of disability policy and poverty. Yet while these theorists argued for some form of income support they did not propose a specific form of income security for further exploration. Few studies have undertaken a comprehensive review of the history of disability income support within the Australian context. This thesis sought to redress these gaps by examining disability income support policy within Australia. The research design consisted of an in-depth critical historical-comparative policy analysis methodology. The use of critical historical-comparative policy analysis allowed the researcher to trace the construction of disability within the Australian disability income support policy across four major historical epochs. A framework was developed specifically to guide analysis of the data. The critical discourse analysis method helped to understand the underlying ideological dimensions that led to the predominance of one particular approach over another. Given this, the research purpose of the study centred on: i. Tracing the history of the Australian disability income support system. ii. Examining the historical patterns and ideological assumptions over time. iii. Exploring the historical patterns and ideological assumptions underpinning an alternative model (Basic Income) and the extent to which each model promotes the social citizenship of people with a disability. The research commitment to a social-relational ontology and the quest for social change centred on the idea that "there has to be a better way" in the provision of disability income support. This theme of searching for an alternative reality in disability income support policy resonated throughout the thesis. This thesis found that the Australian disability income support system is disabling in nature and generates categories of disability on the basis of ableness. From the study, ableness became a condition for citizenship. This study acknowledged that, in reality, income support provision reflects only one aspect of the disabling nature of society which requires redressing. Although there are inherent tensions in any redistributive strategy, the Basic Income model potentially provides an alternative to the Australian disability income support system, given its grounding in social citizenship. The thesis findings have implications for academics, policy-makers and practitioners in terms of developing better ways to understand disability constructs in disability income support policy. The thesis also makes a contribution in terms of promoting income support policies based on the rights of all people, not just a few.
Resumo:
X-ray microtomography (micro-CT) with micron resolution enables new ways of characterizing microstructures and opens pathways for forward calculations of multiscale rock properties. A quantitative characterization of the microstructure is the first step in this challenge. We developed a new approach to extract scale-dependent characteristics of porosity, percolation, and anisotropic permeability from 3-D microstructural models of rocks. The Hoshen-Kopelman algorithm of percolation theory is employed for a standard percolation analysis. The anisotropy of permeability is calculated by means of the star volume distribution approach. The local porosity distribution and local percolation probability are obtained by using the local porosity theory. Additionally, the local anisotropy distribution is defined and analyzed through two empirical probability density functions, the isotropy index and the elongation index. For such a high-resolution data set, the typical data sizes of the CT images are on the order of gigabytes to tens of gigabytes; thus an extremely large number of calculations are required. To resolve this large memory problem parallelization in OpenMP was used to optimally harness the shared memory infrastructure on cache coherent Non-Uniform Memory Access architecture machines such as the iVEC SGI Altix 3700Bx2 Supercomputer. We see adequate visualization of the results as an important element in this first pioneering study.
Resumo:
This study surveys and interrogates key conceptual frameworks and artistic practises that flow through the distinct but interconnected traditions of non-narrative film and experimental music, and examines how these are articulated in my own creative sound practise.
Resumo:
In this study x-ray CT has been used to produce a 3D image of an irradiated PAGAT gel sample, with noise-reduction achieved using the ‘zero-scan’ method. The gel was repeatedly CT scanned and a linear fit to the varying Hounsfield unit of each pixel in the 3D volume was evaluated across the repeated scans, allowing a zero-scan extrapolation of the image to be obtained. To minimise heating of the CT scanner’s x-ray tube, this study used a large slice thickness (1 cm), to provide image slices across the irradiated region of the gel, and a relatively small number of CT scans (63), to extrapolate the zero-scan image. The resulting set of transverse images shows reduced noise compared to images from the initial CT scan of the gel, without being degraded by the additional radiation dose delivered to the gel during the repeated scanning. The full, 3D image of the gel has a low spatial resolution in the longitudinal direction, due to the selected scan parameters. Nonetheless, important features of the dose distribution are apparent in the 3D x-ray CT scan of the gel. The results of this study demonstrate that the zero-scan extrapolation method can be applied to the reconstruction of multiple x-ray CT slices, to provide useful 2D and 3D images of irradiated dosimetry gels.
Resumo:
Celebration (and the celebritisation) of the Australian-ness of children’s authors who enjoy critical or commercial international success, and especially of those who win international prizes speaks to a desire to partake in both national and international cultural spheres. Prizing is often presumed to both guarantee and emerge from a creator's reputation at home and abroad. Australian artist and writer Shaun Tan has received a wide array of cultural and literary prizes, ranging from Australian book awards, to an Academy Award, to the Astrid Lindgren Memorial Prize. This paper considers logics of evaluation and interpretation as they can be traced in the intratextual, intertextual, and extratextual codes of Shaun Tan’s picture book, The Lost Thing (2000), the animated film adaptation of The Lost Thing (2010). It further considers the ways in which the desire for a global audience may necessitate an erasure of the national culture which is traded on in a global market.
Much ado about nothing? Tracing the progress of innovations borne on enterprise social network sites
Resumo:
Enterprise social networks are organizationally bounded online platforms for users to interact with another and maintain interpersonal relationships. The allure of these technologies is often seen in intra-organizational communication, collaboration and innovation. How these technologies actually support organizational innovation efforts remains unclear. A specific challenge is whether digital content on these platforms converts to actual innovation development efforts. In this study we set out to examine innovation-centric content flows on enterprise social networking platforms, and advance a conceptual model that seeks to explain which innovation conveyed in the digital content will traverse from the digital platform into regular processes. We describe important constructs of our model and offer strategies for the operationalization of the constructs. We conclude with an outlook to our ongoing empirical study that will explore and validate the key propositions of our model, and we sketch some potential implications for industry and academia.
Resumo:
This study extends the ‘zero scan’ method for CT imaging of polymer gel dosimeters to include multi-slice acquisitions. Multi slice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter, and processed with the zero scan technique. The results demonstrate that zero scan based gel readout can be successfully applied to generate a three dimensional image of the irradiated gel field. Compared to the raw CT images the processed figures and cross gel profiles demonstrated reduced noise and clear visibility of the penumbral region. Moreover these improved results further highlight the suitability of this method in volumetric reconstruction with reduced CT data acquisition per slice. This work shows that 3D volumes of irradiated polymer gel dosimeters can be acquired and processed with x-ray CT.
Resumo:
X-ray diffraction structure functions for water flowing in a 1.5 mm diameter siphon in the temperature range 4 – 63 °C were obtained using a 20 keV beam at the Australian Synchrotron. These functions were compared with structure functions obtained at the Advanced Light Source for a 0.5 mm thick sample of water in the temperature range 1 – 77 °C irradiated with an 11 keV beam. The two sets of structure functions are similar, but there are subtle differences in the shape and relative position of the two functions suggesting a possible differences between the structure of bulk and siphon water. In addition, the first structural peak (Q0) for water in a siphon, showed evidence of a step-wise increase in Q0 with increasing temperature rather than a smoothly varying increase. More experiments are required to investigate this apparent difference.
Resumo:
Stereotactic radiosurgery treatments involve the delivery of very high doses for a small number of fractions. To date, there is limited data in terms of the skin dose for the very small field sizes used in these treatments. In this work, we determine relative surface doses for small size circular collimators as used in stereotactic radiosurgery treatments. Monte Carlo calculations were performed using the BEAMnrc code with a model of the Novalis 15 Trilogy linear accelerator and the BrainLab circular collimators. The surface doses were calculated at the ICRU skin dose depth of 70 m all using the 6 MV SRS x-ray beam. The calculated surface doses varied between 15 – 12% with decreasing values as the field size increased from 4 to 30 mm. In comparison, surface doses were measured using Gafchromic EBT3 film positioned at the surface of a Virtual Water phantom. The absolute agreement between calculated and measured surface doses was better than 2.5% which is well within the 20 uncertainties of the Monte Carlo calculations and the film measurements. Based on these results, we have shown that the Gafchromic EBT3 film is suitable for surface dose estimates in very small size fields as used in SRS.
Resumo:
Two sources of uncertainty in the X ray computed tomography imaging of polymer gel dosimeters are investigated in the paper.The first cause is a change in postirradiation density, which is proportional to the computed tomography signal and is associated with a volume change. The second cause of uncertainty is reconstruction noise.A simple technique that increases the residual signal to noise ratio by almost two orders of magnitude is examined.