74 resultados para median set


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There’s a diagram that does the rounds online that neatly sums up the difference between the quality of equipment used in the studio to produce music, and the quality of the listening equipment used by the consumer...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existing multi-model approaches for image set classification extract local models by clustering each image set individually only once, with fixed clusters used for matching with other image sets. However, this may result in the two closest clusters to represent different characteristics of an object, due to different undesirable environmental conditions (such as variations in illumination and pose). To address this problem, we propose to constrain the clustering of each query image set by forcing the clusters to have resemblance to the clusters in the gallery image sets. We first define a Frobenius norm distance between subspaces over Grassmann manifolds based on reconstruction error. We then extract local linear subspaces from a gallery image set via sparse representation. For each local linear subspace, we adaptively construct the corresponding closest subspace from the samples of a probe image set by joint sparse representation. We show that by minimising the sparse representation reconstruction error, we approach the nearest point on a Grassmann manifold. Experiments on Honda, ETH-80 and Cambridge-Gesture datasets show that the proposed method consistently outperforms several other recent techniques, such as Affine Hull based Image Set Distance (AHISD), Sparse Approximated Nearest Points (SANP) and Manifold Discriminant Analysis (MDA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In CB Richard Ellis (C) Pty Ltd v Wingate Properties Pty Ltd [2005] QDC 399 McGill DCJ examined whether the court now has a discretion to set aside an irregularly entered default judgment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In C & E Pty Ltd v Corrigan [2006] QCA 47, the Queensland Court of Appeal considered whether r103 of the Uniform Civil Procedure Rules applied to the service of an application to set aside a statutory demand under s459G of the Corporations Act 2001 (Cth). The decision provides analysis and clarification of an issue that has clearly been one of some uncertainty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numeric sets can be used to store and distribute important information such as currency exchange rates and stock forecasts. It is useful to watermark such data for proving ownership in case of illegal distribution by someone. This paper analyzes the numerical set watermarking model presented by Sion et. al in “On watermarking numeric sets”, identifies it’s weaknesses, and proposes a novel scheme that overcomes these problems. One of the weaknesses of Sion’s watermarking scheme is the requirement to have a normally-distributed set, which is not true for many numeric sets such as forecast figures. Experiments indicate that the scheme is also susceptible to subset addition and secondary watermarking attacks. The watermarking model we propose can be used for numeric sets with arbitrary distribution. Theoretical analysis and experimental results show that the scheme is strongly resilient against sorting, subset selection, subset addition, distortion, and secondary watermarking attacks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ever since Cox et. al published their paper, “A Secure, Robust Watermark for Multimedia” in 1996 [6], there has been tremendous progress in multimedia watermarking. The same pattern re-emerged with Agrawal and Kiernan publishing their work “Watermarking Relational Databases” in 2001 [1]. However, little attention has been given to primitive data collections with only a handful works of research known to the authors [11, 10]. This is primarily due to the absence of an attribute that differentiates marked items from unmarked item during insertion and detection process. This paper presents a distribution-independent, watermarking model that is secure against secondary-watermarking in addition to conventional attacks such as data addition, deletion and distortion. The low false positives and high capacity provide additional strength to the scheme. These claims are backed by experimental results provided in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finite element (FE) model studies have made important contributions to our understanding of functional biomechanics of the lumbar spine. However, if a model is used to answer clinical and biomechanical questions over a certain population, their inherently large inter-subject variability has to be considered. Current FE model studies, however, generally account only for a single distinct spinal geometry with one set of material properties. This raises questions concerning their predictive power, their range of results and on their agreement with in vitro and in vivo values. Eight well-established FE models of the lumbar spine (L1-5) of different research centres around the globe were subjected to pure and combined loading modes and compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges, and their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with published median in vitro values. However, the ranges of predictions were larger and exceeded those reported in vitro, especially for the facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with measured in vivo values. In light of high inter-subject variability, the generalization of results of a single model to a population remains a concern. This study demonstrated that the pooled median of individual model results, similar to a probabilistic approach, can be used as an improved predictive tool in order to estimate the response of the lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The MAGIC/UK Medical Research Council (MRC) trial set the standard of care for treatment of resectable gastric and junctional adenocarcinoma, demonstrating that perioperative chemotherapy with epirubicin, cisplatin and 5-fluorouracil (ECF) confers a survival benefit over surgery alone. The randomized ECF for advanced and locally advanced esophagogastric cancer (REAL-2) trial showed that, in the metastatic setting, the EOX regimen (epirubicin, oxaliplatin and capecitabine) is as effective as ECF, with a favourable toxicity profile. Methods Consecutive patients with resectable gastric or junctional adenocarcinoma treated with perioperative EOX, between 2007 and 2012, were retrospectively analysed. Results Fifty-nine patients (12 female, 47 male), commenced EOX therapy; 47 underwent surgery. A good pathological response was seen in 34 %, (16/47). Disease recurrence occurred in 19 patients (19/47, 40 %). Median overall survival was 22 months, with 4-year survival of 47 %. Chemotoxicities were consistent with those previously reported for this regimen. Conclusion This study in a high-volume centre demonstrates that EOX in resectable gastric and junctional adenocarcinoma is associated with a reasonable safety profile, and efficacy consistent with that reported for ECF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary 1. Acoustic methods are used increasingly to survey and monitor bat populations. However, the use of acoustic methods at continental scales can be hampered by the lack of standardized and objective methods to identify all species recorded. This makes comparable continent-wide monitoring difficult, impeding progress towards developing biodiversity indicators, transboundary conservation programmes and monitoring species distribution changes. 2. Here we developed a continental-scale classifier for acoustic identification of bats, which can be used throughout Europe to ensure objective, consistent and comparable species identifications. We selected 1350 full-spectrum reference calls from a set of 15 858 calls of 34 European species, from EchoBank, a global echolocation call library. We assessed 24 call parameters to evaluate how well they distinguish between species and used the 12 most useful to train a hierarchy of ensembles of artificial neural networks to distinguish the echolocation calls of these bat species. 3. Calls are first classified to one of five call-type groups, with a median accuracy of 97·6%. The median species-level classification accuracy is 83·7%, providing robust classification for most European species, and an estimate of classification error for each species. 4. These classifiers were packaged into an online tool, iBatsID, which is freely available, enabling anyone to classify European calls in an objective and consistent way, allowing standardized acoustic identification across the continent. 5. Synthesis and applications. iBatsID is the first freely available and easily accessible continental- scale bat call classifier, providing the basis for standardized, continental acoustic bat monitoring in Europe. This method can provide key information to managers and conservation planners on distribution changes and changes in bat species activity through time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to its ability to represent intricate systems with material nonlinearities as well as irregular loading, boundary, geometrical and material domains, the finite element (FE) method has been recognized as an important computational tool in spinal biomechanics. Current FE models generally account for a single distinct spinal geometry with one set of material properties despite inherently large inter-subject variability. The uncertainty and high variability in tissue material properties, geometry, loading and boundary conditions has cast doubt on the reliability of their predictions and comparability with reported in vitro and in vivo values. A multicenter study was undertaken to compare the results of eight well-established models of the lumbar spine that have been developed, validated and applied for many years. Models were subjected to pure and combined loading modes and their predictions were compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges; their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with previously published median in vitro values. However, the ranges of predictions were larger and exceeded the in vitro ranges, especially for facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with in vivo values. The simulations yielded median facet joint forces of 0 N in flexion, 38 N in extension, 14 N in lateral bending and 60 N in axial rotation that could not be validated due to the paucity of in vivo facet joint forces. In light of high inter-subject variability, one must be cautious when generalizing predictions obtained from one deterministic model. This study demonstrates however that the predictive power increases when FE models are combined together. The median of individual numerical results can hence be used as an improved tool in order to estimate the response of the lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of half-field beam penumbra were taken using EBT2 film for a variety of blocking techniques. It was shown that minimizing the SSD reduces the penumbra as the effects of beam divergence are diminished. The addition of a lead block directly on the surface provides optimal results with a 10-90% penumbra of 0.53 ± 0.02 cm. To resolve the uncertainties encountered in film measurements, future Monte Carlo measurements of halffield penumbras are to be conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the overwhelming increase in the amount of data on the web and data bases, many text mining techniques have been proposed for mining useful patterns in text documents. Extracting closed sequential patterns using the Pattern Taxonomy Model (PTM) is one of the pruning methods to remove noisy, inconsistent, and redundant patterns. However, PTM model treats each extracted pattern as whole without considering included terms, which could affect the quality of extracted patterns. This paper propose an innovative and effective method that extends the random set to accurately weigh patterns based on their distribution in the documents and their terms distribution in patterns. Then, the proposed approach will find the specific closed sequential patterns (SCSP) based on the new calculated weight. The experimental results on Reuters Corpus Volume 1 (RCV1) data collection and TREC topics show that the proposed method significantly outperforms other state-of-the-art methods in different popular measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Registered nurses and midwives play an essential role in detecting patients at risk of deterioration through ongoing assessment and action in response to changing health status. Yet, evidence suggests that clinical deterioration frequently goes unnoticed in hospitalised patients. While much attention has been paid to early warning and rapid response systems, little research has examined factors related to physical assessment skills. OBJECTIVES: To determine a minimum data set of core skills used during nursing assessment of hospitalised patients and identify nurse and workplace predictors of the use of physical assessment to detect patient deterioration. DESIGN: The study used a single-centre, cross-sectional survey design. SETTING and PARTICIPANTS: The study included 434 registered nurses and midwives (Grades 5-7) involved in clinical care of patients on acute care wards, including medicine, surgery, oncology, mental health and maternity service areas, at a 929-bed tertiary referral teaching hospital in Southeast Queensland, Australia. METHODS: We conducted a hospital-wide survey of registered nurses and midwives using the 133-item Physical Assessment Skills Inventory and the 58-item Barriers to Registered Nurses’ Use of Physical Assessment scale. Median frequency for each physical assessment skill was calculated to determine core skills. To explore predictors of core skill utilisation, backward stepwise general linear modelling was conducted. Means and regression coefficients are reported with 95% confidence intervals. A p value < .05 was considered significant for all analyses. RESULTS: Core skills used by most nurses every time they worked included assessment of temperature, oxygen saturation, blood pressure, breathing effort, skin, wound and mental status. Reliance on others and technology (F = 35.77, p < .001), lack of confidence (F = 5.52, p = .02), work area (F = 3.79, p = .002), and clinical role (F = 44.24, p < .001) were significant predictors of the extent of physical assessment skill use. CONCLUSIONS: The increasing acuity of the acute care patient plausibly warrants more than vital signs assessment; however, our study confirms nurses’ physical assessment core skill set is mainly comprised of vital signs. The focus on these endpoints of deterioration as dictated by early warning and rapid response systems may divert attention from and devalue comprehensive nursing assessment that could detect subtle changes in health status earlier in the patient's hospitalisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a paucity of research published in relation to the temporal aspect of destination image change over time. Given increasing investments in destination branding, research is needed to enhance understanding of how to monitor destination brand performance, of which destination image is the core construct, over time. This article reports the results of four studies tracking brand performance of a competitive set of five destinations, between 2003 and 2012. Results indicate minimal changes in perceptions held of the five destinations of interest over the 10 years, supporting the assertion of Gartner (1986) and Gartner and Hunt (1987) that destination image change will only occur slowly over time. While undertaken in Australia, the research approach provides DMOs in other parts of the world with a practical tool for evaluating brand performance over time; in terms of measures of effectiveness of past marketing communications, and indicators of future performance.