151 resultados para HYPERBOLIC LENS
Resumo:
Government programs to finance small firms or start-ups have attracted a little empirical attention. From an economical perspective, the effect of government grants is evaluated by a measure of innovation or firm productivity. Yet, this paper takes a different approach from economical view aiming to address the research question “How do start ups firms view the relationship between government grants and their co-efficient innovation effort?” Semi-structured interviews with grant recipients (start-up business owners revealed that the grants assist firms to leverage their resource limitations but at the same time the grants also act as a major roadblock for their product development success.
Resumo:
Magnetic Resonance Imaging was used to study changes in the crystalline lens and ciliary body with accommodation and aging. Monocular images were obtained in 15 young (19-29 years) and 15 older (60-70 years) emmetropes when viewing at far (6m) and at individual near points (14.5 to 20.9 cm) in the younger group. With accommodation, lens thickness increased (mean±95% CI: 0.33±0.06mm) by a similar magnitude to the decrease in anterior chamber depth (0.31±0.07mm) and equatorial diameter (0.32±0.04mm) with a decrease in the radius of curvature of the posterior lens surface (0.58±0.30mm). Anterior lens surface shape could not be determined due to the overlapping region with the iris. Ciliary ring diameter decreased (0.44±0.17mm) with no decrease in circumlental space or forward ciliary body movement. With aging, lens thickness increased (mean±95% CI: 0.97±0.24mm) similar in magnitude to the sum of the decrease in anterior chamber depth (0.45±0.21mm) and increase in anterior segment depth (0.52±0.23mm). Equatorial lens diameter increased (0.28±0.23mm) with no change in the posterior lens surface radius of curvature. Ciliary ring diameter decreased (0.57±0.41mm) with reduced circumlental space (0.43±0.15mm) and no forward ciliary body movement. Accommodative changes support the Helmholtz theory of accommodation including an increase in posterior lens surface curvature. Certain aspects of aging changes mimic accommodation.
Resumo:
Purpose: To compare accuracies of different methods for calculating human lens power when lens thickness is not available. Methods: Lens power was calculated by four methods. Three methods were used with previously published biometry and refraction data of 184 emmetropic and myopic eyes of 184 subjects (age range [18, 63] years, spherical equivalent range [–12.38, +0.75] D). These three methods consist of the Bennett method, which uses lens thickness, our modification of the Stenström method and the Bennett¬Rabbetts method, both of which do not require knowledge of lens thickness. These methods include c constants, which represent distances from lens surfaces to principal planes. Lens powers calculated with these methods were compared with those calculated using phakometry data available for a subgroup of 66 emmetropic eyes (66 subjects). Results: Lens powers obtained from the Bennett method corresponded well with those obtained by phakometry for emmetropic eyes, although individual differences up to 3.5D occurred. Lens powers obtained from the modified¬Stenström and Bennett¬Rabbetts methods deviated significantly from those obtained with either the Bennett method or phakometry. Customizing the c constants improved this agreement, but applying these constants to the entire group gave mean lens power differences of 0.71 ± 0.56D compared with the Bennett method. By further optimizing the c constants, the agreement with the Bennett method was within ± 1D for 95% of the eyes. Conclusion: With appropriate constants, the modified¬Stenström and Bennett¬Rabbetts methods provide a good approximation of the Bennett lens power in emmetropic and myopic eyes.
Resumo:
To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types.
Resumo:
Purpose. To devise and validate artist-rendered grading scales for contact lens complications Methods. Each of eight tissue complications of contact lens wear (listed under 'Results') was painted by a skilled ophthalmic artist (Terry R. Tarrant) in five grades of severity: 0 (normal), 1 (trace), 2 (mild), 3 (moderate) and 4 (severe). A representative slit lamp photograph of a tissue response of each of the eight complications was shown to 404 contact lens practitioners who had never before used clinical grading scales. The practitioners were asked to grade each tissue response to the nearest 0.1 grade unit by interpolation. Results. The standard deviation (± s.d.) of the 404 responses for each tissue complication is tabulated below:_ing_ 0.5 Endothelial pplymegethisjij-4 0.7 Epithelial microcysts 0.5 Endothelial blebs_ 0.4 Stromal edema_onjunctiva! hyperemia 0.4 Stromal neovascularization 0.4 Papillary conjunctivitis 0.5 The frequency distributions and best-fit normal curves were also plotted. The precision of grading (s.d. x 2) ranged from 0.8 to 1.4, with a mean precision of 1.0. Conclusions. Grading scales afford contact lens practitioners with a method of quantifying the severity of adverse tissue responses to contact lens wear. It is noteworthy that the statistically verified precision of grading (1.0 scale unit) concurs precisely with the essential design feature of the grading scales that each grading step of 1.0 corresponds to clinically significant difference in severity. Thus, as a general rule, a difference or change in grade of > 1.0 can be taken to be both clinically and statistically significant when using these grading scales. Trained observers are likely to achieve even greater grading precision. Supported by Hydron Limited.
Resumo:
Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.
Resumo:
Purpose: Silicone hydrogel contact lenses (CLs) are becoming increasingly popular for daily wear (DW), extended wear (EW) and continuous wear (CW), due to their higher oxygen transmissibility compared to hydrogel CLs. The aim of this study was to investigate the clinical and subjective performance of asmofilcon A (Menicon Co., Ltd), a new surface treated silicone hydrogel CL, during 6-night EW over 6 months (M). Methods: A prospective, randomised, single-masked, monadic study was conducted. N=60 experienced DW soft CL wearers were randomly assigned to wear either asmofilcon A (test: Dk=129, water content (WC)=40%, Nanogloss surface treatment) or senofilcon A (control: Dk=103, WC=38%, PVP internal wetting agent, Vistakon, Johnson & Johnson Vision Care) CLs bilaterally for 6 M on an EW basis. A PHMB-preserved solution (Menicon Co., Ltd) was dispensed for CL care. Evaluations were conducted at CL delivery and after 1 week (W), 4 W, 3 M and 6 M of EW. At each visit, a range of objective and subjective clinical performance measures were assessed. Results: N=50 subjects (83%) successfully completed the study, with the majority of discontinuations due to loss to follow-up (n=3) or moving away/travel (n=5). N=2 subjects experienced adverse events; n=1 unilateral red eye with asmofilcon A and n=1 asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity (HCDVA or LCDVA) between asmofilcon A and senofilcon A; however, LCDVA decreased significantly over time with both CL types (p<0.05). The two CL types did not vary significantly with respect to any of the objective and subjective measures assessed (p>0.05); CL fitting characteristics and CL surface measurements were very similar and mean bulbar and limbal redness measures were always less than grade 1.0. Superior palpebral conjunctival injection showed a statistically, but not clinically, significant increase over time with both CL types (p<0.05). Corneal staining did not vary significantly between asmofilcon A and senofilcon A (p>0.05), with low median gradings of less than 0.5 observed for all areas assessed. There were no solution-related staining reactions observed with either CL type. The asmofilcon A and senofilcon A CLs were both rated highly with respect to overall comfort, with medians of 14 or 15 hours of comfortable lens wearing time per day reported at each of the study visits (p>0.05). Conclusions: Over 6 months of EW, the asmofilcon A and senofilcon A CLs performed in a similar manner with respect to visual acuity, ocular health and CL performance measures. Some changes over time were observed with both CL types, including reduced LCDVA and increased superior palpebral injection, which warrant further investigation in longer-term EW studies. Asmofilcon A appeared to be equivalent in performance to senofilcon A.
Resumo:
Design Science Research (DSR) has emerged as an important approach in Information Systems (IS) research. However, DSR is still in its genesis and has yet to achieve consensus on even the fundamentals, such as what methodology / approach to use for DSR. While there has been much effort to establish DSR methodologies, a complete, holistic and validated approach for the conduct of DSR to guide IS researcher (especially novice researchers) is yet to be established. Alturki et al. (2011) present a DSR ‘Roadmap’, making the claim that it is a complete and comprehensive guide for conducting DSR. This paper aims to further assess this Roadmap, by positioning it against the ‘Idealized Model for Theory Development’ (IM4TD) (Fischer & Gregor 2011). The IM4TD highlights the role of discovery and justification and forms of reasoning to progress in theory development. Fischer and Gregor (2011) have applied IM4TD’s hypothetico-deductive method to analyze DSR methodologies, which is adopted in this study to deductively validate the Alturki et al. (2011) Roadmap. The results suggest that the Roadmap adheres to the IM4TD, is reasonably complete, overcomes most shortcomings identified in other DSR methodologies and also highlights valuable refinements that should be considered within the IM4TD.
Resumo:
This study proceeds from a central interest in the importance of systematically evaluating operational large-scale integrated information systems (IS) in organisations. The study is conducted within the IS-Impact Research Track at Queensland University of Technology (QUT). The goal of the IS-Impact Track is, "to develop the most widely employed model for benchmarking information systems in organizations for the joint benefit of both research and practice" (Gable et al, 2009). The track espouses programmatic research having the principles of incrementalism, tenacity, holism and generalisability through replication and extension research strategies. Track efforts have yielded the bicameral IS-Impact measurement model; the ‘impact’ half includes Organisational-Impact and Individual-Impact dimensions; the ‘quality’ half includes System-Quality and Information-Quality dimensions. Akin to Gregor’s (2006) analytic theory, the ISImpact model is conceptualised as a formative, multidimensional index and is defined as "a measure at a point in time, of the stream of net benefits from the IS, to date and anticipated, as perceived by all key-user-groups" (Gable et al., 2008, p: 381). The study adopts the IS-Impact model (Gable, et al., 2008) as its core theory base. Prior work within the IS-Impact track has been consciously constrained to Financial IS for their homogeneity. This study adopts a context-extension strategy (Berthon et al., 2002) with the aim "to further validate and extend the IS-Impact measurement model in a new context - i.e. a different IS - Human Resources (HR)". The overarching research question is: "How can the impacts of large-scale integrated HR applications be effectively and efficiently benchmarked?" This managerial question (Cooper & Emory, 1995) decomposes into two more specific research questions – In the new HR context: (RQ1): "Is the IS-Impact model complete?" (RQ2): "Is the ISImpact model valid as a 1st-order formative, 2nd-order formative multidimensional construct?" The study adhered to the two-phase approach of Gable et al. (2008) to hypothesise and validate a measurement model. The initial ‘exploratory phase’ employed a zero base qualitative approach to re-instantiating the IS-Impact model in the HR context. The subsequent ‘confirmatory phase’ sought to validate the resultant hypothesised measurement model against newly gathered quantitative data. The unit of analysis for the study is the application, ‘ALESCO’, an integrated large-scale HR application implemented at Queensland University of Technology (QUT), a large Australian university (with approximately 40,000 students and 5000 staff). Target respondents of both study phases were ALESCO key-user-groups: strategic users, management users, operational users and technical users, who directly use ALESCO or its outputs. An open-ended, qualitative survey was employed in the exploratory phase, with the objective of exploring the completeness and applicability of the IS-Impact model’s dimensions and measures in the new context, and to conceptualise any resultant model changes to be operationalised in the confirmatory phase. Responses from 134 ALESCO users to the main survey question, "What do you consider have been the impacts of the ALESCO (HR) system in your division/department since its implementation?" were decomposed into 425 ‘impact citations.’ Citation mapping using a deductive (top-down) content analysis approach instantiated all dimensions and measures of the IS-Impact model, evidencing its content validity in the new context. Seeking to probe additional (perhaps negative) impacts; the survey included the additional open question "In your opinion, what can be done better to improve the ALESCO (HR) system?" Responses to this question decomposed into a further 107 citations which in the main did not map to IS-Impact, but rather coalesced around the concept of IS-Support. Deductively drawing from relevant literature, and working inductively from the unmapped citations, the new ‘IS-Support’ construct, including the four formative dimensions (i) training, (ii) documentation, (iii) assistance, and (iv) authorisation (each having reflective measures), was defined as: "a measure at a point in time, of the support, the [HR] information system key-user groups receive to increase their capabilities in utilising the system." Thus, a further goal of the study became validation of the IS-Support construct, suggesting the research question (RQ3): "Is IS-Support valid as a 1st-order reflective, 2nd-order formative multidimensional construct?" With the aim of validating IS-Impact within its nomological net (identification through structural relations), as in prior work, Satisfaction was hypothesised as its immediate consequence. The IS-Support construct having derived from a question intended to probe IS-Impacts, too was hypothesised as antecedent to Satisfaction, thereby suggesting the research question (RQ4): "What is the relative contribution of IS-Impact and IS-Support to Satisfaction?" With the goal of testing the above research questions, IS-Impact, IS-Support and Satisfaction were operationalised in a quantitative survey instrument. Partial least squares (PLS) structural equation modelling employing 221 valid responses largely evidenced the validity of the commencing IS-Impact model in the HR context. ISSupport too was validated as operationalised (including 11 reflective measures of its 4 formative dimensions). IS-Support alone explained 36% of Satisfaction; IS-Impact alone 70%; in combination both explaining 71% with virtually all influence of ISSupport subsumed by IS-Impact. Key study contributions to research include: (1) validation of IS-Impact in the HR context, (2) validation of a newly conceptualised IS-Support construct as important antecedent of Satisfaction, and (3) validation of the redundancy of IS-Support when gauging IS-Impact. The study also makes valuable contributions to practice, the research track and the sponsoring organisation.
Resumo:
Purpose. To evaluate the use of optical coherence tomography (OCT) to assess the effect of different soft contact lenses on corneoscleral morphology. Methods. Ten subjects had anterior segment OCT B-scans taken in the morning and again after six hours of soft contact lens wear. For each subject, three different contact lenses were used in the right eye on non-consecutive days, including a hydrogel sphere, a silicone hydrogel sphere and a silicone hydrogel toric. After image registration and layer segmentation, analyses were performed of the first hyper-reflective layer (HRL), the epithelial basement membrane (EBL) and the epithelial thickness (HRL to EBL). A root mean square difference (RMSD) of the layer profiles and the thickness change between the morning and afternoon measurements, was used to assess the effect of the contact lens on the corneoscleral morphology. Results. The soft contact lenses had a statistically significant effect on the morphology of the anterior segment layers (p <0.001). The average amounts of change for the three lenses (average RMSD values) for the corneal region were lower (3.93±1.95 µm for the HRL and 4.02±2.14 µm for the EBL) than those measured in the limbal/scleral region (11.24±6.21 µm for the HRL and 12.61±6.42 µm for the EBL). Similarly, averaged across the three lenses, the RMSD in epithelial thickness was lower in the cornea (2.84±0.84 µm) than the limbal/scleral (5.47±1.71 µm) region. Post-hoc analysis showed that ocular surface changes were significantly smaller with the silicone hydrogel sphere lens than both the silicone hydrogel toric (p<0.005) and hydrogel sphere (p<0.02) for the combined HRL and EBL data. Conclusions. In this preliminary study, we have shown that soft contact lenses can produce small but significant changes in the morphology of the limbal/scleral region and that OCT technology is useful in assessing these changes. The clinical significance of these changes is yet to be determined.
Resumo:
Purpose: The aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses. Method: Fourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day. Results: Anterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p ≤ 0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p ≤ 0.05). Conclusion: The corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.
Resumo:
The goal of this article is to propose the model of green human resource initiatives adoption. Based on innovation management and psychology literatures, attitude, pressure and controllability are key drivers for organizational change. Data were collected from 210 organizations in Australia. Results indicated that attitude, pressure and controllability significantly influenced the firms’ adoption of green HR initiatives. Attitude and resource availability especially had greater impacts than pressure. Limitation, implications and future researches are also outlined.
Resumo:
Objective: To establish risk factors for moderate and severe microbial keratitis among daily contact lens (CL) wearers in Australia. Design: A prospective, 12-month, population-based, case-control study. Participants: New cases of moderate and severe microbial keratitis in daily wear CL users presenting in Australia over a 12-month period were identified through surveillance of all ophthalmic practitioners. Case detection was augmented by record audits at major ophthalmic centers. Controls were users of daily wear CLs in the community identified using a national telephone survey. Testing: Cases and controls were interviewed by telephone to determine subject demographics and CL wear history. Multiple binary logistic regression was used to determine independent risk factors and univariate population attributable risk percentage (PAR%) was estimated for each risk factor.; Main Outcome Measures: Independent risk factors, relative risk (with 95% confidence intervals [CIs]), and PAR%. Results: There were 90 eligible moderate and severe cases related to daily wear of CLs reported during the study period. We identified 1090 community controls using daily wear CLs. Independent risk factors for moderate and severe keratitis while adjusting for age, gender, and lens material type included poor storage case hygiene 6.4× (95% CI, 1.9-21.8; PAR, 49%), infrequent storage case replacement 5.4× (95% CI, 1.5-18.9; PAR, 27%), solution type 7.2× (95% CI, 2.3-22.5; PAR, 35%), occasional overnight lens use (<1 night per week) 6.5× (95% CI, 1.3-31.7; PAR, 23%), high socioeconomic status 4.1× (95% CI, 1.2-14.4; PAR, 31%), and smoking 3.7× (95% CI, 1.1-12.8; PAR, 31%). Conclusions: Moderate and severe microbial keratitis associated with daily use of CLs was independently associated with factors likely to cause contamination of CL storage cases (frequency of storage case replacement, hygiene, and solution type). Other factors included occasional overnight use of CLs, smoking, and socioeconomic class. Disease load may be considerably reduced by attention to modifiable risk factors related to CL storage case practice.