576 resultados para testing method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance liquid chromatographic method for the simultaneous analysis of two flavonoids (iso-vitexin and vitexin), and three indole alkaloids (harmane, harmine, and harmol) was developed. This method was then utilised to quantitate levels of these five constituents in methanolic extracts of Australian Passiflora incarnata. HPLC analysis was performed using a Waters™ Novapak C18 (150 × 4 mm, 4 μm) column, with a gradient solvent system of methanol-water-acetic acid. Detection was achieved by PDA UV (254 nm) and fluorescence (excitation 254 nm, emission 414 nm), utilising the external standard method to obtain quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance liquid chromatographic method for the simultaneous determination of five organochlorine pesticides (aldrin, p,p’-DDT, dieldrin, endrin, and heptachlor) was developed. The method was used to determine the levels of these pesticides in medicinal plant samples. Analysis was carried out using a Merck LiChrospher 100 RP C18 (5 μm) column with a gradient solvent system of acetonitrile-water and PDA UV detection (224 nm). Quantification was carried out by the external standard method. The limit of detection for the utilized method was below the local legal limits (ANZFA) for similar plant materials for all 5 pesticides excepting endrin. Medicinal plant extracts were further analyzed by conventional GC-ECD and GC-NPD means using SPE and GPC cleanup as required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved method for the assay of human platelet pyruvate dehydrogenase is described. By generating the substrate [1-14C]pyruvate in situ from [1-14C]lactate plus l-lactate dehydrogenase, the rate of spontaneous decarboxylation is dramatically reduced, allowing far greater sensitivity in the assay of low activities of pyruvate dehydrogenase. In addition, no special precautions are required for the storage and use of [1-14C]lactate, in contrast to those for [1-14C] pyruvate. These factors allow a 5–10-fold increase in sensitivity compared with current methods. The pyruvate dehydrogenase activity of normal subjects as determined by the [1-14C]lactate system was 215 ± 55 pmol · min−1 · mg−1 protein (n = 18). The advantages of this assay system are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin cancer is one of the most commonly occurring cancer types, with substantial social, physical, and financial burdens on both individuals and societies. Although the role of UV light in initiating skin cancer development has been well characterized, genetic studies continue to show that predisposing factors can influence an individual's susceptibility to skin cancer and response to treatment. In the future, it is hoped that genetic profiles, comprising a number of genetic markers collectively involved in skin cancer susceptibility and response to treatment or prognosis, will aid in more accurately informing practitioners' choices of treatment. Individualized treatment based on these profiles has the potential to increase the efficacy of treatments, saving both time and money for the patient by avoiding the need for extensive or repeated treatment. Increased treatment responses may in turn prevent recurrence of skin cancers, reducing the burden of this disease on society. Currently existing pharmacogenomic tests, such as those that assess variation in the metabolism of the anticancer drug fluorouracil, have the potential to reduce the toxic effects of anti-tumor drugs used in the treatment of non-melanoma skin cancer (NMSC) by determining individualized appropriate dosage. If the savings generated by reducing adverse events negate the costs of developing these tests, pharmacogenomic testing may increasingly inform personalized NMSC treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method was developed for studying the genetic relatedness of Pseudomonas aeruginosa isolates from clinical and environmental sources. This bacterium is ubiquitous in the natural environment and is an important pathogen known to infect Cystic Fibrosis (CF) patients. The transmission route of strains has not yet been defined; current theories include acquisition from an environmental source or through patient-to-patient spread. A highly discriminatory, bioinformatics based, DNA typing method was developed to investigate the relatedness of clinical and environmental isolates. This study found a similarity between the environmental and several CF clonal strains and also highlighted occurrence of environmental P. aeruginosa strains in CF infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a cluster ensemble method to map the corpus documents into the semantic space embedded in Wikipedia and group them using multiple types of feature space. A heterogeneous cluster ensemble is constructed with multiple types of relations i.e. document-term, document-concept and document-category. A final clustering solution is obtained by exploiting associations between document pairs and hubness of the documents. Empirical analysis with various real data sets reveals that the proposed meth-od outperforms state-of-the-art text clustering approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entity-oriented retrieval aims to return a list of relevant entities rather than documents to provide exact answers for user queries. The nature of entity-oriented retrieval requires identifying the semantic intent of user queries, i.e., understanding the semantic role of query terms and determining the semantic categories which indicate the class of target entities. Existing methods are not able to exploit the semantic intent by capturing the semantic relationship between terms in a query and in a document that contains entity related information. To improve the understanding of the semantic intent of user queries, we propose concept-based retrieval method that not only automatically identifies the semantic intent of user queries, i.e., Intent Type and Intent Modifier but introduces concepts represented by Wikipedia articles to user queries. We evaluate our proposed method on entity profile documents annotated by concepts from Wikipedia category and list structure. Empirical analysis reveals that the proposed method outperforms several state-of-the-art approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in chromosome 18 in essential hypertension comes from comparative mapping of rat blood pressure quantitative trait loci (QTL), familial orthostatic hypotensive syndrome studies, and essential hypertension pedigree linkage analyses indicating that a locus or loci on human chromosome 18 may play a role in hypertension development. To further investigate involvement of chromosome 18 in human essential hypertension, the present study utilized a linkage scan approach to genotype twelve microsatellite markers spanning human chromosome 18 in 177 Australian Caucasian hypertensive (HT) sibling pairs. Linkage analysis showed significant excess allele sharing of the D18S61 marker when analyzed with SPLINK (P=0.00012), ANALYZE (Sibpair) (P=0.0081), and also with MAPMAKER SIBS (P=0.0001). Similarly, the D18S59 marker also showed evidence for excess allele sharing when analyzed with SPLINK (P=0.016), ANALYZE (Sibpair) (P=0.0095), and with MAPMAKER SIBS (P = 0.014). The adenylate cyclase activating polypeptide 1 gene (ADCYAP1) is involved in vasodilation and has been co-localized to the D18S59 marker. Results testing a microsatellite marker in the 3′ untranslated region of ADCYAP1 in age and gender matched HT and normotensive (NT) individuals showed possible association with hypertension (P = 0.038; Monte Carlo P = 0.02), but not with obesity. The present study shows a chromosome 18 role in essential hypertension and indicates that the genomic region near the ADCYAP1 gene or perhaps the gene itself may be implicated. Further investigation is required to conclusively determine the extent to which ADCYAP1 polymorphisms are involved in essential hypertension. © 2003 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scaffolding is an essential issue in tissue engineering and scaffolds should answer certain essential criteria: biocompatibility, high porosity, and important pore interconnectivity to facilitate cell migration and fluid diffusion. In this work, a modified solvent castingparticulate leaching out method is presented to produce scaffolds with spherical and interconnected pores. Sugar particles (200–300 lm and 300–500 lm) were poured through a horizontal Meker burner flame and collected below the flame. While crossing the high temperature zone, the particles melted and adopted a spherical shape. Spherical particles were compressed in plastic mold. Then, poly-L-lactic acid solution was cast in the sugar assembly. After solvent evaporation, the sugar was removed by immersing the structure into distilled water for 3 days. The obtained scaffolds presented highly spherical interconnected pores, with interconnection pathways from 10 to 100 lm. Pore interconnection was obtained without any additional step. Compression tests were carried out to evaluate the scaffold mechanical performances. Moreover, rabbit bone marrow mesenchymal stem cells were found to adhere and to proliferate in vitro in the scaffold over 21 days. This technique produced scaffold with highly spherical and interconnected pores without the use of additional organic solvents to leach out the porogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One limitation of electrospinning stems from the charge build-up that occurs during processing, preventing further fibre deposition and limiting the scaffold overall thickness and hence their end-use in tissue engineering applications targeting large tissue defect repair. To overcome this, we have developed a technique in which thermally induced phase separation (TIPS) and electrospinning are combined. Thick three-dimensional, multilayered composite scaffolds were produced by simply stacking individual polycaprolactone (PCL) microfibrous electrospun discs into a cylindrical holder that was filled with a 3% poly(lactic-co-glycolic acid) (PLGA) solution in dimethylsulfoxide (a good solvent for PLGA but a poor one for PCL). The construct was quenched in liquid nitrogen and the solvent removed by leaching out in cold water. This technique enables the fabrication of scaffolds composed principally of electrospun membranes that have no limit to their thickness. The mechanical properties of these scaffolds were assessed under both quasi-static and dynamic conditions. The multilayered composite scaffolds had similar compressive properties to 5% PCL scaffolds fabricated solely by the TIPS methodology. However, tensile tests demonstrated that the multilayered construct outperformed a scaffold made purely by TIPS, highlighting the contribution of the electrospun component of the composite scaffold to enhancing the overall mechanical property slate. Cell studies revealed cell infiltration principally from the scaffold edges under static seeding conditions. This fabrication methodology permits the rapid construction of thick, strong scaffolds from a range of biodegradable polymers often used in tissue engineering, and will be particularly useful when large dimension electrospun scaffolds are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review question/objective What is the effect of using the teach-back method for health education to improve adherence to treatment regimen and self-management in chronic disease? Inclusion criteria Types of participants This review will consider all studies that include adult patients (aged 18 years and over) in any healthcare setting, either as inpatients (eg acute care, medical and surgical wards) or those who attend primary health care, family medical practice, general medical practice, clinics, outpatient departments, rehabilitation or community settings. Participants need to have been diagnosed as having one or more chronic diseases including heart failure, diabetes, cardiovascular disease, cancer, respiratory disease, asthma, chronic obstructive pulmonary disease, chronic kidney disease, arthritis, epilepsy or a mental health condition. Studies that include seriously ill patients, and/or those who have impairments in verbal communication and cognitive function will be excluded. Types of intervention This review will consider studies that investigate the use of the teach-back method alone or in combination with other supporting education, either in routine or research intervention education programs; regardless of how long the programs were and whether or not a follow-up was conducted. The intervention could be delivered by any healthcare professional. The comparator will be any health education for chronic disease that does not include the teach-back method. Types of outcomes Primary outcomes of interest are disease-specific knowledge, adherence, and self-management knowledge, behavior and skills measured using patient report, nursing observation or validated measurement scales. Secondary outcomes include knowledge retention, self-efficacy, hospital readmission, hospitalization, and quality of life, also measured using patient report, nursing observation, hospital records or validated measurement scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cross-sectional survey was conducted, and the construct validity and reliability of the Brisbane Practice Environment Measure in an Australian sample of registered nurses were examined. Nurses were randomly selected from the database of an Australian nursing organization. The original 33 items of the Brisbane Practice Environment Measure were utilized to inform the psychometric properties using confirmatory factor analysis. The Cronbach's alpha was 0.938 for the total scale and ranged 0.657–0.887 for the subscales. A five-factor structure of the measure was confirmed, χ2 = 944.622, (P < 0.01), χ2/d.f. ratio = 2.845, Tucker Lewis Index 0.929, Root Mean Square Error = 0.061 and Comparative Fit Index = 0.906. The selected 28 items of the measure proved reliable and valid in measuring effects of the practice environment upon Australian nurses. The implications are that regular measurement of the practice environment using these 28 items might assist in the development of strategies which might improve job satisfaction and retention of registered nurses in Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the study was to undertake rigorous psychometric testing of the Caring Efficacy Scale in a sample of Registered Nurses. A cross-sectional survey of 2000 registered nurses was undertaken. The Caring Efficacy Scale was utilised to inform the psychometric properties of the selected items of the Caring Efficacy Scale. Cronbach’s Alpha identified reliability of the data. Exploratory Factor Analysis and Confirmatory Factor Analysis were undertaken to validate the factors. Confirmatory factor analysis confirmed the development of two factors; Confidence to Care and Doubts and Concerns. The Caring Efficacy Scale has undergone rigorous psychometric testing, affording evidence of internal consistency and goodness-of-fit indices within satisfactory ranges. The Caring Efficacy Scale is valid for use in an Australian population of registered nurses. The scale can be used as a subscale or total score reflective of self-efficacy in nursing. This scale may assist nursing educators to predict levels of caring efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of losses in high efficiency / high power converters is difficult. Measuring the losses directly from the difference between the input and output power results in large errors. Calorimetric methods are usually used to bypass this issue but introduce different problems, such as, long measurement times, limited power loss measurement range and/or large set up cost. In this paper the total losses of a converter are measured directly and switching losses are exacted. The measurements can be taken with only three multimeters and a current probe and a standard bench power supply. After acquiring two or three power loss versus output current sweeps, a series of curve fitting processes are applied and the switching losses extracted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key to reducing cost of electric vehicles is integration. All too often systems such as the motor, motor controller, batteries and vehicle chassis/body are considered as separate problems. The truth is that a lot of trade-offs can be made between these systems, causing an overall improvement in many areas including total cost. Motor controller and battery cost have a relatively simple relationship; the less energy lost in the motor controller the less energy that has to be carried in the batteries, hence the lower the battery cost. A motor controller’s cost is primarily influenced by the cost of the switches. This paper will therefore present a method of assessing the optimal switch selection on the premise that the optimal switch is the one that produces the lowest system cost, where system cost is the cost of batteries + switches.