457 resultados para strong-field


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emergency relief centres provide financial, housing, food and other types of support to families and individuals who experience financial hardship. These centres are non-profit, often government supported organizations that rely on the help of their volunteers and social workers. This paper reports on our preliminary findings from field visits to one such centre called Communify, in the inner west of Brisbane, Australia. Communify runs an emergency food relief facility for people who find themselves in a crisis or temporarily unable to afford groceries. Over a period of five months, we did several field visits to the centre and carried out 21 short in-situ interviews, with a mix of Communify clients and volunteers. Our results shed light on people’s experiences of financial hardship and their interactions with the emergency relief centre. In particular, issues related to their perceived values and stigmas associated with their experiences are highlighted in our findings. We identify opportunities for design that can empower people struggling with financial hardship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mapping and evaluating a student's progress on placement is a core element of social work education but there has been scant attention to indicate how to effectively create and assess student learning and performance. This paper outlines a project undertaken by the Combined Schools of Social Work to develop a common learning and assessment tool that is being used by all social work schools in Victoria. The paper describes how the Common Assessment Tool (CAT) was developed, drawing on the Australian Association of Social Work Practice Standards, leading to seven key learning areas that form the basis of the assessment of a student's readiness for practice. An evaluation of the usefulness of the CAT was completed by field educators, liaison staff, and students, which confirmed that the CAT was a useful framework for evaluating students' learning goals. The feedback also identified a number of problematic features that were addressed in a revised CAT and rating scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Social work students consistently identify their field placement as having the most impact on their learning. Despite this, research on learning activities used during placement and the impact on practice competency and social work identity is limited. This is the second paper from a research study exploring student experiences of learning on placement. Data were gathered from 263 social work students about 14 key learning activities they experienced during placement. The more regularly students engaged in learning activities with their social work supervisor, the more likely they were to report a sense of social work identity and feelings of practice competence. However, the regular use of learning activities varied widely between placements. Surprisingly, approximately half the students did not regularly have the opportunity to observe social work practice, have their practice observed, or to link social work theory and the Code of Ethics to their practice with their social work supervisor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent decades, there has been a strong call by writers in education for alternative forms of leadership and management that are human centred and that value social cohesion, fairness, and democratic practices. Referred to by names such as transformative leadership (Shields, 2013) and ethical leadership (Starratt, 1996), those promoting these types of leadership argue for the use of “power as a moral force for the common good” (Duignan, 2007, p.12). In this chapter, our interest lies with managers in universities and how they use power in ethical and unethical ways. We consider some macro forces (e.g., globalisation, neo-liberal policies) that have impacted universities, making it difficult for managers to promote socially just and equitable practices. In particular, we examine the influence of managerialism—the application of private sector practices to the public sector—where the role of manager is not to question current practices, but to conform to performance targets, and to ensure compliance (O’Brien & Down, 2002). To come to an understanding of what might constitute ethical practices, we refer to the field of micropolitics as a way to help illuminate current practice and point to more positive ways of working.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Australian perspectives and practices within early childhood education and care are underpinned by understandings of children, how they learn, their emotional and physical needs and their connectedness to family and their communities. There is strong international research evidence supporting the value of providing high quality and accessible early childhood education and care, and this evidence base continues to grow. Drawing on international and Australian research, this book provides an introduction to this complex and multifaceted field.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mathematical models describing the movement of multiple interacting subpopulations are relevant to many biological and ecological processes. Standard mean-field partial differential equation descriptions of these processes suffer from the limitation that they implicitly neglect to incorporate the impact of spatial correlations and clustering. To overcome this, we derive a moment dynamics description of a discrete stochastic process which describes the spreading of distinct interacting subpopulations. In particular, we motivate our model by mimicking the geometry of two typical cell biology experiments. Comparing the performance of the moment dynamics model with a traditional mean-field model confirms that the moment dynamics approach always outperforms the traditional mean-field approach. To provide more general insight we summarise the performance of the moment dynamics model and the traditional mean-field model over a wide range of parameter regimes. These results help distinguish between those situations where spatial correlation effects are sufficiently strong, such that a moment dynamics model is required, from other situations where spatial correlation effects are sufficiently weak, such that a traditional mean-field model is adequate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter proposes that to capture expertise in field settings sport scientists should base experimental designs on an inter-disciplinary theoretical foundation and utilise coach and athlete expertise to identify the key variables upon which to focus. We propose that an ecological dynamics framework may allow motor learning and performance to be examined in a more representative manner. After initially considering the problem from the view of a “new” skill acquisition scientist, we provide an overview of previous approaches, before providing theoretical and practically driven ideas to guide sport scientists’ practice going forward.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Markerless motion capture systems are relatively new devices that can significantly speed up capturing full body motion. A precision of the assessment of the finger’s position with this type of equipment was evaluated at 17.30 ± 9.56 mm when compare to an active marker system [1]. The Microsoft Kinect was proposed to standardized and enhanced clinical evaluation of patients with hemiplegic cerebral palsy [2]. Markerless motion capture systems have the potential to be used in a clinical setting for movement analysis, as well as for large cohort research. However, the precision of such system needs to be characterized. Global objectives • To assess the precision within the recording field of the markerless motion capture system Openstage 2 (Organic Motion, NY). • To compare the markerless motion capture system with an optoelectric motion capture system with active markers. Specific objectives • To assess the noise of a static body at 13 different location within the recording field of the markerless motion capture system. • To assess the smallest oscillation detected by the markerless motion capture system. • To assess the difference between both systems regarding the body joint angle measurement. Methods Equipment • OpenStage® 2 (Organic Motion, NY) o Markerless motion capture system o 16 video cameras (acquisition rate : 60Hz) o Recording zone : 4m * 5m * 2.4m (depth * width * height) o Provide position and angle of 23 different body segments • VisualeyezTM VZ4000 (PhoeniX Technologies Incorporated, BC) o Optoelectric motion capture system with active markers o 4 trackers system (total of 12 cameras) o Accuracy : 0.5~0.7mm Protocol & Analysis • Static noise: o Motion recording of an humanoid mannequin was done in 13 different locations o RMSE was calculated for each segment in each location • Smallest oscillation detected: o Small oscillations were induced to the humanoid mannequin and motion was recorded until it stopped. o Correlation between the displacement of the head recorded by both systems was measured. A corresponding magnitude was also measured. • Body joints angle: o Body motion was recorded simultaneously with both systems (left side only). o 6 participants (3 females; 32.7 ± 9.4 years old) • Tasks: Walk, Squat, Shoulder flexion & abduction, Elbow flexion, Wrist extension, Pronation / supination (not in results), Head flexion & rotation (not in results), Leg rotation (not in results), Trunk rotation (not in results) o Several body joint angles were measured with both systems. o RMSE was calculated between signals of both systems. Results Conclusion Results show that the Organic Motion markerless system has the potential to be used for assessment of clinical motor symptoms or motor performances However, the following points should be considered: • Precision of the Openstage system varied within the recording field. • Precision is not constant between limb segments. • The error seems to be higher close to the range of motion extremities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All sound research commence with the selection of a research paradigm. The chosen research paradigm is significant in shaping the researcher’s perspectives of the world and it is a vital step in any study’s’ research design. There are different paradigms that IS researchers can choose from; amongst which the interpretive paradigm is growing in acceptance.. Though interpretive research has emerged as an important strand in Information Systems (IS), guidelines on how to conduct interpretive research and how to evaluate them have been scarce. Klein and Myers presented seven principles with examples for each from three case examples. While these principles are much valued, there is a lack of support for novice researchers on how to embed these principles in an overall research design, which could help with the aid of a detailed example that has done so. Thus, this paper aims to address this gap, and presents how Klein and Myers’s principles were applied within an example study that investigated shared services in the Malaysian Higher Education context. The example study adopted the interpretive paradigm as the most suited approach that fitted their research questions and goals. More details about the selection and adoption of the Klein and Myers’s guidelines in the context of the shared services research case study are presented in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The study of ethnically homogeneous populations may help to identify schizophrenia risk loci. The authors conducted a genomewide linkage scan for schizophrenia in an Indian population. METHOD: Participants were 441 individuals (262 affected probands and siblings) who were recruited primarily from one ethnically homogeneous group, the Tamil Brahmin caste, although individuals from other geographically proximal castes also participated. Genotyping of 124 affected sibling pair pedigrees was performed with 402 short tandem repeat polymorphisms. Linkage analyses were conducted using nonparametric exponential LOD (logarithm of the odds ratio for linkage) scores and parametric heterogeneity LOD scores. Parametric heterogeneity scores were calculated using simple dominant and recessive models, correcting for multiple statistics. The data were examined for evidence of consanguinity. Genomewide significance levels were determined using 10,000 gene dropping simulations. RESULTS: These findings revealed genomewide significant linkage to chromosome 1p31.1, through the use of both exponential and heterogeneity LOD scores, incorporating correction for multiple statistics and mild consanguinity. The estimated sibling recurrence risk associated with this putative locus was 1.95. Analysis for heterogeneity LOD scores also detected suggestive linkage to chromosomes 13q22.1 and 16q12.2. Using 117 tag single nucleotide polymorphisms (SNPs), family-based association analyses of phosphodiesterase 4B (PDE4B), the closest schizophrenia candidate gene, detected no convincing evidence of association, suggesting that the chromosome 1 peak represents a novel risk locus. CONCLUSIONS: This is the first study-to the authors' knowledge-to report significant linkage of schizophrenia to chromosome 1p31.1. Further investigation of this chromosome region in diverse populations is warranted to identify underlying sequence variants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using electric-field-induced optical second-harmonic generation (EFISHG) measurement, we analyzed hysteresis behavior of capacitance-voltage (C-V) characteristics of IZO/polyterpenol (PT)/C₆₀/pentacene/Au diodes, where PT layer is actively working as a hole-transport electron-blocking layer. The EFISHG measurement verified the presence of interface accumulated charges in the diodes, and showed that a space charge electric field from accumulated excess electrons (holes) that remain at the PT/C₆₀ (C₆₀/pentacene) interface is responsible for the hysteresis loop observed in the C-V characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-resolved electric field induced second harmonic generation technique was used to probe the carrier transients within double-layer pentacene-based MIM devices. Polyterpenol thin films fabricated from non-synthetic environmentally sustainable source were used as a blocking layer to assist in visualisation of single-species carrier transportation during charging and discharging under different bias conditions. Results demonstrated that carrier transients were comprised of charging on electrodes, followed by carrier injection and charging of the interface. Polyterpenol was demonstrated to be a sound blocking material and can therefore be effectively used for probing of double-layer devices using EFISHG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A non-synthetic polymer material, polyterpenol, was fabricated using a dry polymerization process namely RF plasma polymerization from an environmentally friendly monomer and its surface, optical and electrical properties investigated. Polyterpenol films were found to be transparent over the visible wavelength range, with a smooth surface with an average roughness of less than 0.4 nm and hardness of 0.4 GPa. The dielectric constant of 3.4 for polyterpenol was higher than that of the conventional polymer materials used in the organic electronic devices. The non-synthetic polymer material was then implemented as a surface modification of the gate insulator in field effect transistor (OFET) and the properties of the device were examined. In comparison to the similar device without the polymer insulating layer, the polyterpenol based OFET device showed significant improvements. The addition of the polyterpenol interlayer in the OFET shifted the threshold voltage significantly; + 20 V to -3 V. The presence of trapped charge was not observed in the polyterpenol interlayer. This assisted in the improvement of effective mobility from 0.012 to 0.021 cm 2/Vs. The switching property of the polyterpenol based OFET was also improved; 107 compared to 104. The results showed that the non-synthetic polyterpenol polymer film is a promising candidate of insulators in electronic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.