101 resultados para dose calculation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study uses dosimetry film measurements and Monte Carlo simulations to investigate the accuracy of type-a (pencil-beam) dose calculations for predicting the radiation doses delivered during stereotactic radiotherapy treatments of the brain. It is shown that when evaluating doses in a water phantom, the type-a algorithm provides dose predictions which are accurate to within clinically relevant criteria, gamma(3%,3mm), but these predictions are nonetheless subtly different from the results of evaluating doses from the same fields using radiochromic film and Monte Carlo simulations. An analysis of a clinical meningioma treatment suggests that when predicting stereotactic radiotherapy doses to the brain, the inaccuracies of the type-a algorithm can be exacerbated by inadequate evaluation of the effects of nearby bone or air, resulting in dose differences of up to 10% for individual fields. The results of this study indicate the possible advantage of using Monte Carlo calculations, as well as measurements with high-spatial resolution media, to verify type-a predictions of dose delivered in cranial treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of how to efficiently and safely design dose finding studies. Both current and novel utility functions are explored using Bayesian adaptive design methodology for the estimation of a maximum tolerated dose (MTD). In particular, we explore widely adopted approaches such as the continual reassessment method and minimizing the variance of the estimate of an MTD. New utility functions are constructed in the Bayesian framework and are evaluated against current approaches. To reduce computing time, importance sampling is implemented to re-weight posterior samples thus avoiding the need to draw samples using Markov chain Monte Carlo techniques. Further, as such studies are generally first-in-man, the safety of patients is paramount. We therefore explore methods for the incorporation of safety considerations into utility functions to ensure that only safe and well-predicted doses are administered. The amalgamation of Bayesian methodology, adaptive design and compound utility functions is termed adaptive Bayesian compound design (ABCD). The performance of this amalgamation of methodology is investigated via the simulation of dose finding studies. The paper concludes with a discussion of results and extensions that could be included into our approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter is in response to the recently published article “Evaluation of two self-referent foot health instruments” by Robert Trevethan (RT) and is in regard to the scale scores he derived when using the quality of life measure, the Foot Health Status Questionnaire [1]. Unfortunately, the journal reviewers and editor did not identify, or address, a fundamental flaw in the methodology of this paper. Subsequently, the inference drawn from this paper could, in all reasonableness, mislead the reader

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between radiologic union and clinical outcomes in thoracoscopic scoliosis surgery is not clear, as apparent non-union of a spinal fusion does not always correspond to a poor clinical result. The aim of this study was to evaluate for the first time the interbody fusion rates using low dose CT scans at minimum 24 months after thoracoscopic scoliosis surgery, and to explore the relationship between fusion scores and; (i) rod diameter, (ii) graft type, (iii) fusion level, (iv) implant failure, and (v) lateral position in the disc space. The study found that moderate fusion scores on the Sucato scale secure successful clinical outcomes in thoracoscopic scoliosis surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is a cancer treatment modality in which a dose of ionising radiation is delivered to a tumour. The accurate calculation of the dose to the patient is very important in the design of an effective therapeutic strategy. This study aimed to systematically examine the accuracy of the radiotherapy dose calculations performed by clinical treatment planning systems by comparison againstMonte Carlo simulations of the treatment delivery. A suite of software tools known as MCDTK (Monte Carlo DICOM ToolKit) was developed for this purpose, and is capable of: • Importing DICOM-format radiotherapy treatment plans and producing Monte Carlo simulation input files (allowing simple simulation of complex treatments), and calibrating the results; • Analysing the predicted doses of and deviations between the Monte Carlo simulation results and treatment planning system calculations in regions of interest (tumours and organs-at-risk) and generating dose-volume histograms, so that conformity with dose prescriptions can be evaluated. The code has been tested against various treatment planning systems, linear acceleratormodels and treatment complexities. Six clinical head and neck cancer treatments were simulated and the results analysed using this software. The deviations were greatest where the treatment volume encompassed tissues on both sides of an air cavity. This was likely due to the method the planning system used to model low density media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality assurance of stereotactic radiotherapy and radiosurgery treatments requires the use of small-field dose measurements that can be experimentally challenging. This study used Monte Carlo simulations to establish that PAGAT dosimetry gel can be used to provide accurate, high resolution, three-dimensional dose measurements of stereotactic radiotherapy fields. A small cylindrical container (4 cm height, 4.2 cm diameter) was filled with PAGAT gel, placed in the parietal region inside a CIRS head phantom, and irradiated with a 12 field stereotactic radiotherapy plan. The resulting three-dimensional dose measurement was read out using an optical CT scanner and compared with the treatment planning prediction of the dose delivered to the gel during the treatment. A BEAMnrc DOSXYZnrc simulation of this treatment was completed, to provide a standard against which the accuracy of the gel measurement could be gauged. The three dimensional dose distributions obtained from Monte Carlo and from the gel measurement were found to be in better agreement with each other than with the dose distribution provided by the treatment planning system's pencil beam calculation. Both sets of data showed close agreement with the treatment planning system's dose distribution through the centre of the irradiated volume and substantial disagreement with the treatment planning system at the penumbrae. The Monte Carlo calculations and gel measurements both indicated that the treated volume was up to 3 mm narrower, with steeper penumbrae and more variable out-of-field dose, than predicted by the treatment planning system. The Monte Carlo simulations allowed the accuracy of the PAGAT gel dosimeter to be verified in this case, allowing PAGAT gel to be utilised in the measurement of dose from stereotactic and other radiotherapy treatments, with greater confidence in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate if low-dose lithium may counteract the microstructural and metabolic brain changes proposed to occur in individuals at ultra-high risk (UHR) for psychosis. Methods: Hippocampal T2 relaxation time (HT2RT) and proton magnetic resonance spectroscopy (1H-MRS) measurements were performed prior to initiation and following three months of treatment in 11 UHR patients receiving low-dose lithium and 10 UHR patients receiving treatment as usual (TAU). HT2RT and 1H-MRS percentage change scores between scans were compared using one-way ANOVA and correlated with behavioural change scores. Results: Low-dose lithium significantly reduced HT2RT compared to TAU (p=0.018). No significant group by time effects were seen for any brain metabolites as measured with 1H-MRS, although myo-inositol, creatine, choline-containing compounds and NAA increased in the group receiving low-dose lithium and decreased or remained unchanged in subjects receiving TAU. Conclusions: This pilot study suggests that low-dose lithium may protect the microstructure of the hippocampus in UHR states as reflected by significantly decreasing HT2RT. Larger scale replication studies in UHR states using T2 relaxation time as a proxy for emerging brain pathology seem a feasible mean to test neuroprotective strategies such as low-dose lithium as potential treatments to delay or even prevent the progression to full-blown disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Although physical activity is associated with health-related quality of life (HRQL), the nature of the dose-response relationship remains unclear. This study examined the concurrent and prospective dose-response relationships between total physical activity (TPA) and (only) walking with HRQL in two age cohorts of women. Methods Participants were 10,698 women born in 1946-1951 and 7,646 born in 1921-1926, who completed three mailed surveys for the Australian Longitudinal Study on Women's Health. They reported weekly TPA minutes (sum of walking, moderate, and vigorous minutes). HRQL was measured with the Medical Outcomes Study Short-Form 36 Health Status Survey (SF-36). Linear mixed models, adjusted for socio-demographic and health-related variables, were used to examine associations between TPA level (none, very low, low, intermediate, sufficient, high, and very high) and SF-36 scores. For women who reported walking as their only physical activity, associations between walking and SF-36 scores were also examined. Results Curvilinear trends were observed between TPA and walking with SF-36 scores. Concurrently, HRQL scores increased significantly with increasing TPA and walking, in both cohorts, with increases less marked above sufficient activity levels. Prospectively, associations were attenuated although significant and meaningful improvements in physical functioning and vitality were observed across most TPA and walking categories above the low category. Conclusion For women in their 50s-80s without clinical depression, greater amounts of TPA are associated with better current and future HRQL, particularly physical functioning and vitality. Even if walking is their only activity, women, particularly those in their 70s-80s, have better health-related quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to ultrafine particles (diameter less than 100 nm) is an important topic in epidemiological and toxicological studies. This study used the average particle number size distribution data obtained from our measurement survey in major micro-environments, together with the people activity pattern data obtained from the Italian Human Activity Pattern Survey to estimate the tracheobronchial and alveolar dose of submicrometer particles for different population age groups in Italy. We developed a numerical methodology based on Monte Carlo method, in order to estimate the best combination from a probabilistic point of view. More than 106 different cases were analyzed according to a purpose built sub-routine and our results showed that the daily alveolar particle number and surface area deposited for all of the age groups considered was equal to 1.5 x 1011 particles and 2.5 x 1015 m2, respectively, varying slightly for males and females living in Northern or Southern Italy. In terms of tracheobronchial deposition, the corresponding values for daily particle number and surface area for all age groups was equal to 6.5 x 1010 particles and 9.9 x 1014 m2, respectively. Overall, the highest contributions were found to come from indoor cooking (female), working time (male) and transportation (i.e. traffic derived particles) (children).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alveolar and tracheobronchial-deposited submicrometer particle number and surface area data received by different age groups in Australia are shown. Activity patterns were combined with microenvironmental data through a Monte-Carlo method. Particle number distributions for the most significant microenvironments were obtained from our measurement survey data and people activity pattern data from the Australian Human Activity Pattern Survey were used. Daily alveolar particle number (surface area) dose received by all age groups was equal to 3.0×1010 particles (4.5×102 mm2), varying slightly between males and females. In contrast to gender, the lifestyle was found to significantly affect the daily dose, with highest depositions characterizing adults. The main contribution was due to indoor microenvironments. Finally a comparison between Italian and Australian people in terms of received particle dose was reported; it shows that different cooking styles can affect dose levels: higher doses were received by Italians, mainly due to their particular cooking activity.