102 resultados para device for counting,
Resumo:
There is considerable public, political and professional debate about the need for additional hospital beds in Australia. However, there is no clarity in regard to the definition, meaning and significance of hospital bed counts. Relative to population, there has been a total decline in bed availability in Australia over the past 15 years of 14.6% (22.9% for public hospital beds). This decline is partly offset by reductions in length of stay and changes to models of care; however, the net effect is increased bed occupancy which has in turn resulted in system-wide congestion. Future bed capability needs to be better planned to meet growing demands while at the same time continuing trends for more efficient use. Future planning should be based in part on weighted bed capability matched to need.
Resumo:
Railway signaling facilitates two main functions, namely, train detection and train control, in order to maintain safe separations among the trains. Track circuits are the most commonly used train detection means with the simple open/close circuit principles; and subsequent adoption of axle counters further allows the detection of trains under adverse track conditions. However, with electrification and power electronics traction drive systems, aggravated by the electromagnetic interference in the vicinity of the signaling system, railway engineers often find unstable or even faulty operations of track circuits and axle counting systems, which inevitably jeopardizes the safe operation of trains. A new means of train detection, which is completely free from electromagnetic interference, is therefore required for the modern railway signaling system. This paper presents a novel optical fiber sensor signaling system. The sensor operation, field setup, axle detection solution set, and test results of an installation in a trial system on a busy suburban railway line are given.
Resumo:
The present paper addresses the findings of a preliminary investigation into policy and codes of conduct pertaining to the use of laptops and PDA’s in business meetings. The purpose of this study was to conduct a review of policies or codes of conduct pertaining to the use of laptops and PDAs in meetings. The investigation included academic literature, policy searches in the public domain of the Internet, as well as personal contact with target industries (large corporations – N=1000 + employees). The results highlight the dearth of policy and codes of conducts pertaining to the use of laptops and PDA’s in business meetings. Consequently, given the growing interdependence between mobile technologies and the contemporary workplace, there exists an opportunity for communication professionals to further research and develop policy and codes of conduct in this area. Implications for corporate communication policies and practices are also discussed.
Resumo:
Much of the research on the delivery of advice by professionals such as physicians, health workers and counsellors, both on the telephone and in face to face interaction more generally, has focused on the theme of client resistance and the consequent need for professionals to adopt particular formats to assist in the uptake of the advice. In this paper we consider one setting, Kid’s Helpline, the national Australian counselling service for children and young people, where there is an institutional mandate not to give explicit advice in accordance with the values of self-direction and empowerment. The paper examines one practice, the use of script proposals by counsellors, which appears to offer a way of providing support which is consistent with these values. Script proposals entail the counsellors packaging their advice as something that the caller might say – at some future time – to a third party such as a friend, teacher, parent, or partner, and involve the counsellor adopting the speaking position of the caller in what appears as a rehearsal of a forthcoming strip of interaction. Although the core feature of a script proposal is the counsellor’s use of direct reported speech they appear to be delivered, not so much as exact words to be followed, but as the type of conversation that the client needs to have with the 3rd party. Script proposals, in short, provide models of what to say as well as alluding to how these could be emulated by the client. In their design script proposals invariably incorporate one or more of the most common rhetorical formats for maximising the persuasive force of an utterance such as a three part list or a contrastive pair. Script proposals, moreover, stand in a complex relation to the prior talk and one of their functions appears to be to summarise, respecify or expand upon the client’s own ideas or suggestions for problem solving that have emerged in these preceding sequences.
Resumo:
BACKGROUND: Treatment of proximal humerus fractures in elderly patients is challenging because of reduced bone quality. We determined the in vitro characteristics of a new implant developed to target the remaining bone stock, and compared it with an implant in clinical use. METHODS: Following osteotomy, left and right humeral pairs from cadavers were treated with either the Button-Fix or the Humerusblock fixation system. Implant stiffness was determined for three clinically relevant cases of load: axial compression, torsion, and varus bending. In addition, a cyclic varus-bending test was performed. RESULTS: We found higher stiffness values for the humeri treated with the ButtonFix system--with almost a doubling of the compression, torsion, and bending stiffness values. Under dynamic loading, the ButtonFix system had superior stiffness and less K-wire migration compared to the Humerusblock system. INTERPRETATION: When compared to the Humerusblock design, the ButtonFix system showed superior biomechanical properties, both static and dynamic. It offers a minimally invasive alternative for the treatment of proximal humerus fractures.
Resumo:
Fractures of long bones are sometimes treated using various types of fracture fixation devices including internal plate fixators. These are specialised plates which are used to bridge the fracture gap(s) whilst anatomically aligning the bone fragments. The plate is secured in position by screws. The aim of such a device is to support and promote the natural healing of the bone. When using an internal fixation device, it is necessary for the clinician to decide upon many parameters, for example, the type of plate and where to position it; how many and where to position the screws. While there have been a number of experimental and computational studies conducted regarding the configuration of screws in the literature, there is still inadequate information available concerning the influence of screw configuration on fracture healing. Because screw configuration influences the amount of flexibility at the area of fracture, it has a direct influence on the fracture healing process. Therefore, it is important that the chosen screw configuration does not inhibit the healing process. In addition to the impact on the fracture healing process, screw configuration plays an important role in the distribution of stresses in the plate due to the applied loads. A plate that experiences high stresses is prone to early failure. Hence, the screw configuration used should not encourage the occurrence of high stresses. This project develops a computational program in Fortran programming language to perform mathematical optimisation to determine the screw configuration of an internal fixation device within constraints of interfragmentary movement by minimising the corresponding stress in the plate. Thus, the optimal solution suggests the positioning and number of screws which satisfies the predefined constraints of interfragmentary movements. For a set of screw configurations the interfragmentary displacement and the stress occurring in the plate were calculated by the Finite Element Method. The screw configurations were iteratively changed and each time the corresponding interfragmentary displacements were compared with predefined constraints. Additionally, the corresponding stress was compared with the previously calculated stress value to determine if there was a reduction. These processes were continued until an optimal solution was achieved. The optimisation program has been shown to successfully predict the optimal screw configuration in two cases. The first case was a simplified bone construct whereby the screw configuration solution was comparable with those recommended in biomechanical literature. The second case was a femoral construct, of which the resultant screw configuration was shown to be similar to those used in clinical cases. The optimisation method and programming developed in this study has shown that it has potential to be used for further investigations with the improvement of optimisation criteria and the efficiency of the program.
Resumo:
Studying the rate of cell migration provides insight into fundamental cell biology as well as a tool to assess the functionality of synthetic surfaces and soluble environments used in tissue engineering. The traditional tools used to study cell migration include the fence and wound healing assays. In this paper we describe the development of a microchannel based device for the study of cell migration on defined surfaces. We demonstrate that this device provides a superior tool, relative to the previously mentioned assays, for assessing the propagation rate of cell wave fronts. The significant advantage provided by this technology is the ability to maintain a virgin surface prior to the commencement of the cell migration assay. Here, the device is used to assess rates of mouse fibroblasts (NIH 3T3) and human osteosarcoma (SaOS2) cell migration on surfaces functionalized with various extracellular matrix proteins as a demonstration that confining cell migration within a microchannel produces consistent and robust data. The device design enables rapid and simplistic assessment of multiple repeats on a single chip, where surfaces have not been previously exposed to cells or cellular secretions.