128 resultados para Rating of Employees


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fire safety of light gauge cold-formed steel frame (LSF) wall systems is significant to the build-ing design. Gypsum plasterboard is widely used as a fire safety material in the building industry. It contains gypsum (CaSO4.2H2O), Calcium Carbonate (CaCO3) and most importantly free and chemically bound water in its crystal structure. The dehydration of the gypsum and the decomposition of Calcium Carbonate absorb heat, which gives the gypsum plasterboard fire resistant qualities. Recently a new composite panel system was developed, where a thin insulation layer was used externally between two plasterboards to improve the fire performance of LSF walls. In this research, finite element thermal models of both the traditional LSF wall panels with cavity insulation and the new LSF composite wall panels were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties of gypsum plaster-board, insulation materials and steel were used. The developed models were then validated by comparing their results with fire test results. This paper presents the details of the developed finite element models of non-load bearing LSF wall panels and the thermal analysis results. It has shown that finite element models can be used to simulate the thermal behaviour of LSF walls with varying configurations of insulations and plasterboards. The results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection. Effects of real fire conditions are also presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cold-formed steel stud walls are an important component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin-walled steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of these wall systems while past research showed contradicting results about the benefits of cavity insulation. This research proposed a new LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating of walls. Full scale fire tests were conducted using both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. Eleven full scale load bearing wall specimens were tested to study the thermal and structural performances of the load bearing wall assemblies under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls while also providing good explanations and supporting test data to overcome the incorrect industry assumptions about cavity insulation. Tests demonstrated that the use of external insulation in a composite panel form enhanced the thermal and structural performances of stud walls and increased their fire resistance rating significantly. This paper presents the details of the full scale fire tests of load-bearing wall assemblies lined with plasterboards and different types of insulation under varying load ratios. Test results including the temperature and deflection profiles of walls measured during the fire tests will be presented along with their failure modes and failure times.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fire safety has become an important part in structural design due to the ever increasing loss of properties and lives during fires. Conventionally the fire rating of load bearing wall systems made of Light gauge Steel Frames (LSF) is determined using fire tests based on the standard time-temperature curve given in ISO 834 (ISO, 1999). The standard time-temperature curve given in ISO 834 (ISO, 1999) originated from the application of wood burning furnaces in the early 1900s. However, modern commercial and residential buildings make use of thermoplastic materials, which mean considerably high fuel loads. Hence a detailed fire research study into the performance of LSF walls was undertaken using the developed real fire curves based on Eurocode parametric curves (ECS, 2002) and Barnett’s BFD curves (Barnett, 2002) using both full scale fire tests and numerical studies. It included LSF walls without any insulation, and the recently developed externally insulated composite panel system. This paper presents the details of the numerical studies and the results. It also includes brief details of the development of real building fire curves and experimental studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract. Fire resistance has become an important part in structural design due to the ever increasing loss of properties and lives every year. Conventionally the fire rating of load bearing Light gauge Steel Frame (LSF) walls is determined using standard fire tests based on the time-temperature curve given in ISO 834 [1]. Full scale fire testing based on this standard time-temperature curve originated from the application of wood burning furnaces in the early 1900s and it is questionable whether it truly represents the fuel loads in modern buildings. Hence a detailed fire research study into the performance of LSF walls was undertaken using real design fires based on Eurocode parametric curves [2] and Barnett’s ‘BFD’ curves [3]. This paper presents the development of these real fire curves and the results of full scale experimental study into the structural and fire behaviour of load bearing LSF stud wall systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Quality of work life (QWL) is defined as the extent to which employee is satisfied with personal and working needs through participating in the workplace while achieving the organisation’s goals. QWL has been found to influence the commitment and productivity of employees in healthcare organisations, as well as in other industries. However, reliable information on the QWL of PHC nurses is limited. The purpose of this study was to assess the QWL among PHC nurses in the Jazan region, Saudi Arabia. Methods: A descriptive research design, namely, a cross-sectional survey was used in this study. Data were collected using Brooks’ survey of quality of nursing work life (QNWL) and demographic questions. A convenience sample was recruited from 143 PHC centres in Jazan, Saudi Arabia. The Jazan region is located in the southern part of Saudi Arabia. A response rate of 91% (N = 532/585) was achieved (effective RR = 87%, n = 508). Data analysis consisted of descriptive statistics, t-test and one way-analysis of variance. Total scores and sub-scores for QWL Items and item summary statistics were computed and reported, using SPSS version 17 for Windows. Results: Findings suggested that the respondents were dissatisfied with their work life. The major influencing factors were unsuitable working hours/shifts, lack of facilities for nurses, inability to balance work with family needs, inadequacy of family-leave time, poor staffing, management and supervision practices, lack of professional development opportunities, and inappropriate working environment in terms of the level of security, patient care supplies and equipment, and recreation facilities (Break-area). Other essential factors include the community’s view of nursing and inadequate salary. More positively, the majority of nurses were satisfied with their co-workers, satisfied to be nurses and had a sense of belonging in their workplaces. Significant differences were found according to gender, age, marital status, dependent children, dependent adults, nationality, ethnicity, nursing tenure, organisational tenure, positional tenure, and payment per month. No significant differences were found according to education level and location of PHC. Conclusions: These findings can be used by PHC managers and policy makers for developing and appropriately implementing successful plans to improve the QWL. This will help to enhance the home and work environments, improve individual and organisation performance and increase nurses’ commitment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

There is increasing concern about the impact of employees‟ alcohol and other drug (AOD) consumption on workplace safety and performance, particularly within the construction industry. While most Australian jurisdictions have identified this as a critical safety issue, information is limited regarding the prevalence of AODs in the workplace and there is limited evidential guidance regarding how to effectively and efficiently address such an issue. The current research aims to scientifically evaluate the use of AODs within the Australian construction industry in order to reduce the potential resulting safety and performance impacts and engender a cultural change in the workforce - to render it unacceptable to arrive at a construction workplace with impaired judgement from AODs. The study will adopt qualitative and quantitative methods to firstly evaluate the extent of general AOD use in the industry. Secondly, the development of an appropriate industry policy will adopt a non-punitive and rehabilitative approach developed in consultation with employers and employees across the infrastructure and building sectors, with the aim it be adopted nationally for adoption at the construction workplace. Finally, an industry specific cultural change management program and implementation plan will be developed through a nationally collaborative approach. Final results indicate that a proportion of those sampled in the construction sector may be at risk of hazardous alcohol consumption. A total of 286 respondents (58%) scored above the cut-off cumulative score for risky or hazardous alcohol. Other drug use was also identified as a major issue. Results support the need for evidence-based, preventative educational initiatives that are tailored to the industry. This paper will discuss the final survey and interview results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study examined physiological and performance effects of pre-cooling on medium-fast bowling in the heat. Ten, medium-fast bowlers completed two randomised trials involving either cooling (mixed-methods) or control (no cooling) interventions before a 6-over bowling spell in 31.9±2.1°C and 63.5±9.3% relative humidity. Measures included bowling performance (ball speed, accuracy and run-up speeds), physical characteristics (global positioning system monitoring and counter-movement jump height), physiological (heart rate, core temperature, skin temperature and sweat loss), biochemical (serum concentrations of damage, stress and inflammation) and perceptual variables (perceived exertion and thermal sensation). Mean ball speed (114.5±7.1 vs. 114.1±7.2 km · h−1; P = 0.63; d = 0.09), accuracy (43.1±10.6 vs. 44.2±12.5 AU; P = 0.76; d = 0.14) and total run-up speed (19.1±4.1 vs. 19.3±3.8 km · h−1; P = 0.66; d = 0.06) did not differ between pre-cooling and control respectively; however 20-m sprint speed between overs was 5.9±7.3% greater at Over 4 after pre-cooling (P = 0.03; d = 0.75). Pre-cooling reduced skin temperature after the intervention period (P = 0.006; d = 2.28), core temperature and pre-over heart rates throughout (P = 0.01−0.04; d = 0.96−1.74) and sweat loss by 0.4±0.3 kg (P = 0.01; d = 0.34). Mean rating of perceived exertion and thermal sensation were lower during pre-cooling trials (P = 0.004−0.03; d = 0.77−3.13). Despite no observed improvement in bowling performance, pre-cooling maintained between-over sprint speeds and blunted physiological and perceptual demands to ease the thermoregulatory demands of medium-fast bowling in hot conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Numerous environmental rating tools have developed around the world over the past decade or so, in an attempt to increase awareness of the impact buildings have on the environment. Whilst many of these tools can be applied across a variety of building types, the majority focus mainly on the commercial building sector. Only recently have some of the better known environmental rating tools become adaptable to the land development sector, where arguably the most visible environmental impacts are made. EnviroDevelopment is one such tool that enables rating of residential land development in Australia. This paper seeks to quantify the environmental benefits achieved by the environmental rating tool EnviroDevelopment, using data from its certified residential projects across Australia. This research will identify the environmental gains achieved in the residential land development sector that can be attributed to developers aspiring to gain certification under this rating tool.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fire safety has become an important part in structural design due to the ever increasing loss of properties and lives during fires. Fire rating of load bearing wall systems made of Light gauge Steel Frames (LSF) is determined using fire tests based on the standard time-temperature curve given in ISO 834. However, modern residential buildings make use of thermoplastic materials, which mean considerably high fuel loads. Hence a detailed fire research study into the performance of load bearing LSF walls was undertaken using a series of realistic design fire curves developed based on Eurocode parametric curves and Barnett’s BFD curves. It included both full scale fire tests and numerical studies of LSF walls without any insulation, and the recently developed externally insulated composite panels. This paper presents the details of fire tests first, and then the numerical models of tested LSF wall studs. It shows that suitable finite element models can be developed to predict the fire rating of load bearing walls under real fire conditions. The paper also describes the structural and fire performances of externally insulated LSF walls in comparison to the non-insulated walls under real fires, and highlights the effects of standard and real fire curves on fire performance of LSF walls.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This article analyses the inconsistent approaches taken by courts when interpreting provisions of the Corporations Act which address debts or expenses “incurred” by receivers, administrators and liquidators. The article contends for a consistent construction of these provisions which will enable the legislation to operate (as was intended) for the benefit of persons who supply goods, services or labour to companies in external administration. The article explains how and why debts can be “incurred” by insolvency practitioners continuing on pre-existing contracts. Specifically, the article contends for a construction of ss 419 and 443A of the Corporations Act which renders receivers and administrators personally liable for certain entitlements of employees (eg, wages and superannuation contributions) which become due and payable by reason of the decision of a receiver or administrator to continue a pre-existing contract rather than terminate it.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Immigration has played an important role in the historical development of Australia. Thus, it is no surprise that a large body of empirical work has developed, which focuses upon how migrants fare in the land of opportunity. Much of the literature is comparatively recent, i.e. the last ten years or so, encouraged by the advent of public availability of Australian crosssection micro data. Several different aspects of migrant welfare have been addressed, with major emphasis being placed upon earnings and unemployment experience. For recent examples see Haig (1980), Stromback (1984), Chiswick and Miller (1985), Tran-Nam and Nevile (1988) and Beggs and Chapman (1988). The present paper contributes to the literature by providing additional empirical evidence on the native/migrant earnings differential. The data utilised are from the rather neglected Australian Bureau of Statistics, ABS Special Supplementary Survey No.4. 1982, otherwise known as the Family Survey. The paper also examines the importance of distinguishing between the wage and salary sector and the self-employment sector when discussing native/migrant differentials. Separate earnings equations for the two labour market groups are estimated and the native/migrant earnings differential is broken down by employment status. This is a novel application in the Australian context and provides some insight into the earnings of the selfemployed, a group that despite its size (around 20 per cent of the labour force) is frequently ignored by economic research. Most previous empirical research fails to examine the effect of employment status on earnings. Stromback (1984) includes a dummy variable representing self-employment status in an earnings equation estimated over a pooled sample of paid and self-employed workers. The variable is found to be highly significant, which leads Stromback to question the efficacy of including the self-employed in the estimation sample. The suggestion is that part of self-employed earnings represent a return to non-human capital investment, i.e. investments in machinery, buildings etc, the structural determinants of earnings differ significantly from those for paid employees. Tran-Nam and Nevile (1988) deal with differences between paid employees and the selfemployed by deleting the latter from their sample. However, deleting the self-employed from the estimation sample may lead to bias in the OLS estimation method (see Heckman 1979). The desirable properties of OLS are dependent upon estimation on a random sample. Thus, the 'Ran-Nam and Nevile results are likely to suffer from bias unless individuals are randomly allocated between self-employment and paid employment. The current analysis extends Tran-Nam and Nevile (1988) by explicitly treating the choice of paid employment versus self-employment as being endogenously determined. This allows an explicit test for the appropriateness of deleting self-employed workers from the sample. Earnings equations that are corrected for sample selection are estimated for both natives and migrants in the paid employee sector. The Heckman (1979) two-step estimator is employed. The paper is divided into five major sections. The next section presents the econometric model incorporating the specification of the earnings generating process together with an explicit model determining an individual's employment status. In Section 111 the data are described. Section IV draws together the main econometric results of the paper. First, the probit estimates of the labour market status equation are documented. This is followed by presentation and discussion of the Heckman two-stage estimates of the earnings specification for both native and migrant Australians. Separate earnings equations are estimated for paid employees and the self-employed. Section V documents estimates of the nativelmigrant earnings differential for both categories of employees. To aid comparison with earlier work, the Oaxaca decomposition of the earnings differential for paid-employees is carried out for both the simple OLS regression results as well as the parameter estimates corrected for sample selection effects. These differentials are interpreted and compared with previous Australian findings. A short section concludes the paper.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Principal Topic Counties in Northern Europe, such as Sweden, Finland and Denmark, have comparatively low per capita rates of entrepreneurship as measured by independent new venture start-up rates – as for example measured by the Global Entrepreneurship Monitor (GEM) Total entrepreneurial activity (TEA) rate. However, the latest 2011 GEM data reveals that these same countries have comparatively very high Employee Entrepreneurship Activity (EEA) rates – that is a high rate per capita of employees involved in new product development or new enterprise activities. This observation has prompted us to investigate the role of national culture in driving independent versus employee entrepreneurial activities. Prior research has established that national (and regional) culture plays an important role in forming an “entrepreneurial culture” that encourages (or discourages) independent business start-ups and TEA (e.g. Davidsson, 1995; Beugelsdijk, 2007). However, the relationship of culture and EEA has not received research attention. Moreover, empirical relationships between elements of national culture and independent entrepreneurship have revealed some surprising results. For example, Wildeman et al. (1999) report an unexpected higher share of individual business ownership in countries that have higher uncertainty avoidance, higher power distance and lower individualism according to Hofstede’s dimensions of culture. They speculate that dissatisfaction can be a source of entrepreneurship: in countries with a high power distance, a high uncertainty avoidance and low individualism, there may be relatively more business owners since enterprising individuals cannot satisfy their needs within existing organizations. Yet it remains a rather open question whether entrepreneurial behaviour in existing organisations provides a satisfactory explanation for these empirical findings. Methods We will conduct a cross sectional study of the influence of national culture according to the five / six dimensions of Hofstede (1980; 2001) on both TEA and EEA for the 54 countries that participated in GEM 2011. Since it is well established that the opportunities for entrepreneurship vary substantially with a country’s level of economic development, we intend to conduct separate analyses for the three categories of development – innovation driven economies, efficient driven economies and factor driven economies. We also intend to restrict our assessment of TEA to opportunity driven entrepreneurship, as necessity driven entrepreneurship has a different relationship to the “entrepreneurial culture” that is the focus of our study. We will control for a range of factors such as GDP growth, ease of doing business index and unemployment. Results and Implications Descriptive analyses of the GEM TEA and EEA data reveal clusters of countries that appear to be have similar national culture. We are yet to conduct regression analyses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cold-formed steel lipped channels are commonly used in LSF wall construction as load bearing studs with plasterboards on both sides. Under fire conditions, cold-formed thin-walled steel sections heat up quickly resulting in fast reduction in their strength and stiffness. Usually the LSF wall panels are subjected to fire from one side which will cause thermal bowing, neutral axis shift and magnification effects due to the development of non-uniform temperature distributions across the stud. This will induce an additional bending moment in the stud and hence the studs in LSF wall panels should be designed as a beam column considering both the applied axial compression load and the additional bending moment. Traditionally the fire resistance rating of these wall panels is based on approximate prescriptive methods. Very often they are limited to standard wall configurations used by the industry. Therefore a detailed research study is needed to develop fire design rules to predict the failure load and hence the failure time of LSF wall panels subject to non-uniform temperature distributions. This paper presents the details of an investigation to develop suitable fire design rules for LSF wall studs under non-uniform elevated temperature distributions. Applications of the previously developed fire design rules based on AISI design manual and Eurocode 3 Parts 1.2 and 1.3 to LSF wall studs were investigated in detail and new simplified fire design rules based on AS/NZS 4600 and Eurocode 3 Part 1.3 were proposed in the current study with suitable allowances for the interaction effects of compression and bending actions. The accuracy of the proposed fire design rules was verified by using the results from full scale fire tests and extensive numerical studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Light Gauge Steel Framing (LSF) walls made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings on both sides are commonly used in commercial, industrial and residential buildings. However, there is limited data about their structural and thermal performance under fire conditions while past research showed contradicting results about the benefits of using cavity insulation. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. In this research 11 full scale tests were conducted on conventional load bearing steel stud walls with and without cavity insulation, and the new composite panel system to study their thermal and structural performance under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided supporting research data. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of LSF walls and increased their fire resistance rating. This paper presents the details of the LSF wall tests and the thermal and structural performance data and fire resistance rating of load-bearing wall assemblies lined with varying plasterboard-insulation configurations under two different load ratios. Fire test results including the time–temperature and deflection profiles are presented along with the failure times and modes.