341 resultados para Light-dependent
Resumo:
Fire design is an essential element of the overall design procedure of structural steel members and systems. Conventionally the fire rating of load-bearing stud wall systems made of light gauge steel frames (LSF) is based on approximate prescriptive methods developed on the basis of limited fire tests. This design is limited to standard wall configurations used by the industry. Increased fire rating is provided simply by adding more plasterboards to the stud walls. This is not an acceptable situation as it not only inhibits innovation and structural and cost efficiencies but also casts doubt over the fire safety of these light gauge steel stud wall systems. Hence a detailed fire research study into the performance and effectiveness of a recently developed innovative composite panel wall system was undertaken at Queensland University of Technology using both full scale fire tests and numerical studies. Experimental results of LSF walls using the new composite panels under axial compression load have shown the improvement in fire performance and fire resistance rating. Numerical analyses are currently being undertaken using the finite element program ABAQUS. Measured temperature profiles of the studs are used in the numerical models and the results are used to calibrate against full scale test results. The validated model will be used in a detailed parametric study with an aim to develop suitable design rules within the current cold-formed steel structures and fire design standards. This paper will present the results of experimental and numerical investigations into the structural and fire behaviour of light gauge steel stud walls protected by the new composite panel. It will demonstrate the improvements provided by the new composite panel system in comparison to traditional wall systems.
Resumo:
The Achilles tendon has been seen to exhibit time-dependent conditioning when isometric muscle actions were of a prolonged duration, compared to those involved in dynamic activities, such as walking. Since, the effect of short duration muscle activation associated with dynamic activities is yet to be established, the present study aimed to investigate the effect of incidental walking activity on Achilles tendon diametral strain. Eleven healthy male participants refrained from physical activity in excess of the walking required to carry out necessary daily tasks and wore an activity monitor during the 24 h study period. Achilles tendon diametral strain, 2 cm proximal to the calcaneal insertion, was determined from sagittal sonograms. Baseline sonographic examinations were conducted at ∼08:00 h followed by replicate examinations at 12 and 24 h. Walking activity was measured as either present (1) or absent (0) and a linear weighting function was applied to account for the proximity of walking activity to tendon examination time. Over the course of the day the median (min, max) Achilles tendon diametral strain was −11.4 (4.5, −25.4)%. A statistically significant relationship was evident between walking activity and diametral strain (P < 0.01) and this relationship improved when walking activity was temporally weighted (AIC 131 to 126). The results demonstrate that the short yet repetitive loads generated during activities of daily living, such as walking, are sufficient to induce appreciable time-dependant conditioning of the Achilles tendon. Implications arise for the in vivo measurement of Achilles tendon properties and the rehabilitation of tendinopathy.
Resumo:
Alexithymia is characterised by deficits in emotional insight and self reflection, that impact on the efficacy of psychological treatments. Given the high prevalence of alexithymia in Alcohol Use Disorders, valid assessment tools are critical. The majority of research on the relationship between alexithymia and alcohol-dependence has employed the self-administered Toronto Alexithymia Scale (TAS-20). The Observer Alexithymia Scale (OAS) has also been recommended. The aim of the present study was to assess the validity and reliability of the OAS and the TAS-20 in an alcohol-dependent sample. Two hundred and ten alcohol-dependent participants in an outpatient Cognitive Behavioral Treatment program were administered the TAS-20 at assessment and upon treatment completion at 12 weeks. Clinical psychologists provided observer assessment data for a subsample of 159 patients. The findings confirmed acceptable internal consistency, test-retest reliability and scale homogeneity for both the OAS and TAS-20, except for the low internal consistency of the TAS-20 EOT scale. The TAS-20 was more strongly associated with alcohol problems than the OAS.
Resumo:
The Light of Gairdner is a key work of the author's exhibition Lightsite, which toured Western Australian galleries from February 2006 to November 2007. It is a five-minute-long exposure photographic image captured inside a purpose-built, room-sized pinhole camera which is demountable and does not have a floor. The Light of Gairdner depicts two brothers Allan and Harvey Lynch during their barley harvest. Allan is standing outside the pinhole camera-room in the barley field. The light from this exterior landscape is 'projected' inside the camera-room and illuminates the interior scene which includes that part of the barley field upon which the floorless room is erected, along with Harvey who is standing inside. The image evokes the temporality of light. Here, light itself is portrayed as the primary medium through which we both perceive and describe landscape. It is through the agency of light that we construct our connectivity to landscape. The exhibition/catalogue statement. "Harvey and Allan Lynch lost their father Frank, in a crop dusting crash five years ago. They now manage their dad's 6000 acre farm and are photographed here at the time of their barley harvest."
Resumo:
The Light of Gairdner 2 is a key work of the author's exhibition Lightsite, which toured Western Australian galleries from February 2006 to November 2007. It is a five-minute-long exposure photographic image captured inside a purpose-built, room-sized pinhole camera which is demountable and does not have a floor. The Light of Gairdner 2 depicts two brothers Allan and Harvey Lynch during their barley harvest. Allan is standing outside the pinhole camera-room in the barley field with their new 'CASE' harvester. The light from this exterior landscape is 'projected' inside the camera-room and illuminates the interior scene which includes that part of the barley field upon which the floorless room is erected, along with Harvey who is standing inside. The image evokes the temporality of light. Here, light itself is portrayed as the primary medium through which we both perceive and describe landscape. In this way it is through the agency of light that we construct our connectivity to landscape. The exhibition/catalogue statement. "Harvey and Allan Lynch lost their father Frank, in a crop dusting crash five years ago. They now manage their dad's 6000 acre farm and are photographed here at the time of their barley harvest. The Light of Gairdner 2 features their new 'CASE' harvester, and in the distance, the grain silos of Gairdner."
Resumo:
Cold-formed steel members can be assembled in various combinations to provide cost-efficient and safe light gauge floor systems for buildings. Such Light gauge Steel Framing (LSF) systems are widely accepted in industrial and commercial building construction. An example application is in floor-ceiling systems. Light gauge steel floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire-rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite floor-ceiling system has been developed to provide higher fire rating under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Therefore a research project was carried out to investigate its structural and fire resistance behaviour under standard fire conditions. In this research project full scale experimental tests of the new LSF floor system based on a composite ceiling unit were undertaken using a gas furnace at the Queensland University of Technology. Both the conventional and the new steel floor-ceiling systems were tested under structural and fire loads. Full scale fire tests provided a good understanding of the fire behaviour of the LSF floor-ceiling systems and confirmed the superior performance of the new composite system. This paper presents the details of this research into the structural and fire behaviour of light gauge steel floor systems protected by the new composite panel, and the results.
Resumo:
Light gauge steel frame (LSF) structures are increasingly used in commercial and residential buildings because of their non-combustibility, dimensional stability and ease of installation. A common application is in floor-ceiling systems. The LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire-rated floor-ceiling assemblies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite floor-ceiling system has been developed to provide higher fire rating. But its increased fire rating could not be determined using the currently available design methods. Therefore a research project was conducted to investigate its structural and fire resistance behaviour under standard fire conditions. This paper presents the results of full scale experimental investigations into the structural and fire behaviour of the new LSF floor system protected by the composite ceiling unit. Both the conventional and the new floor systems were tested under structural and fire loads. It demonstrates the improvements provided by the new composite panel system in comparison to conventional floor systems. Numerical studies were also undertaken using the finite element program ABAQUS. Measured temperature profiles of floors were used in the numerical analyses and their results were compared with fire test results. Tests and numerical studies provided a good understanding of the fire behaviour of the LSF floor-ceiling systems and confirmed the superior performance of the new composite system.
Resumo:
A promenade performance. This research produced a unique combination of performance using electronically augmented costuming, site-specific discrete electronic lighting and video projection and sustained mountainside/top choreography. The work was examined and expanded in two subsequent peer reviewed papers which scoped out the emerging field of ‘Grounded Media’. Curator and writer Kevin Murray further accorded and enhanced these ideas in subsequent critical writing and the work was also featured in a two page major profile in RealtimeThe work was commissioned by the long established Floating Land Festival and involved extensive on-site work as well as a residency, production and artist talk series at the Noosa Art Gallery. A documentary film of the work was subsequently presented in the three-month exhibition ‘Lines of Sight’ for the Nishi Ogi Machi Media Festival, Nishiogikubo Station Platform 1, Tokyo, Japan, curated by Youkobo Art Space.
Resumo:
In this study, the influence of pH on interfacial energy distributed over the phospholipids-bilayer surface model and the effect of hydrophobicity on coefficient of friction (f) were investigated by using microelectrophoresis. An important clinical implication of deficiency in hydrophobicity is the loss of phospholipids that is readily observed in osteoarthritis joints. This paper establishes the influence of pH on interfacial energy upon an increase f, which might be associated with a decrease of hydrophobicity of the articular surface.
Resumo:
Current-voltage (I-V) curves of Poly(3-hexyl-thiophene) (P3HT) diodes have been collected to investigate the polymer hole-dominated charge transport. At room temperature and at low electric fields the I-V characteristic is purely Ohmic whereas at medium-high electric fields, experimental data shows that the hole transport is Trap Dominated - Space Charge Limited Current (TD-SCLC). In this regime, it is possible to extract the I-V characteristic of the P3HT/Al junction showing the ideal Schottky diode behaviour over five orders of magnitude. At high-applied electric fields, holes’ transport is found to be in the trap free SCLC regime. We have measured and modelled in this regime the holes’ mobility to evaluate its dependence from the electric field applied and the temperature of the device.
Resumo:
Cold-formed steel members are extensively used in the building construction industry, especially in residential, commercial and industrial buildings. In recent times, fire safety has become important in structural design due to increased fire damage to properties and loss of lives. However, past research into the fire performance of cold-formed steel members has been limited, and was confined to compression members. Therefore a research project was undertaken to investigate the structural behaviour of compact cold-formed steel lipped channel beams subject to inelastic local buckling and yielding, and lateral-torsional buckling effects under simulated fire conditions and associated section and member moment capacities. In the first phase of this research, an experimental study based on tensile coupon tests was undertaken to obtain the mechanical properties of elastic modulus and yield strength and the stress-strain relationship of cold-formed steels at uniform ambient and elevated temperatures up to 700oC. The mechanical properties deteriorated with increasing temperature and are likely to reduce the strength of cold-formed beams under fire conditions. Predictive equations were developed for yield strength and elastic modulus reduction factors while a modification was proposed for the stressstrain model at elevated temperatures. These results were used in the numerical modelling phases investigating the section and member moment capacities. The second phase of this research involved the development and validation of two finite element models to simulate the behaviour of compact cold-formed steel lipped channel beams subject to local buckling and yielding, and lateral-torsional buckling effects. Both models were first validated for elastic buckling. Lateral-torsional buckling tests of compact lipped channel beams were conducted at ambient temperature in order to validate the finite element model in predicting the non-linear ultimate strength behaviour. The results from this experimental study did not agree well with those from the developed experimental finite element model due to some unavoidable problems with testing. However, it highlighted the importance of magnitude and direction of initial geometric imperfection as well as the failure direction, and thus led to further enhancement of the finite element model. The finite element model for lateral-torsional buckling was then validated using the available experimental and numerical ultimate moment capacity results from past research. The third phase based on the validated finite element models included detailed parametric studies of section and member moment capacities of compact lipped channel beams at ambient temperature, and provided the basis for similar studies at elevated temperatures. The results showed the existence of inelastic reserve capacity for compact cold-formed steel beams at ambient temperature. However, full plastic capacity was not achieved by the mono-symmetric cold-formed steel beams. Suitable recommendations were made in relation to the accuracy and suitability of current design rules for section moment capacity. Comparison of member capacity results from finite element analyses with current design rules showed that they do not give accurate predictions of lateral-torsional buckling capacities at ambient temperature and hence new design rules were developed. The fourth phase of this research investigated the section and member moment capacities of compact lipped channel beams at uniform elevated temperatures based on detailed parametric studies using the validated finite element models. The results showed the existence of inelastic reserve capacity at elevated temperatures. Suitable recommendations were made in relation to the accuracy and suitability of current design rules for section moment capacity in fire design codes, ambient temperature design codes as well as those proposed by other researchers. The results showed that lateral-torsional buckling capacities are dependent on the ratio of yield strength and elasticity modulus reduction factors and the level of non-linearity in the stress-strain curves at elevated temperatures in addition to the temperature. Current design rules do not include the effects of non-linear stress-strain relationship and therefore their predictions were found to be inaccurate. Therefore a new design rule that uses a nonlinearity factor, which is defined as the ratio of the limit of proportionality to the yield stress at a given temperature, was developed for cold-formed steel beams subject to lateral-torsional buckling at elevated temperatures. This thesis presents the details and results of the experimental and numerical studies conducted in this research including a comparison of results with predictions using available design rules. It also presents the recommendations made regarding the accuracy of current design rules as well as the new developed design rules for coldformed steel beams both at ambient and elevated temperatures.
Resumo:
Fracture behavior of Cu-Ni laminate composites has been investigated by tensile testing. It was found that as the individual layer thickness decreases from 100 to 20nm, the resultant fracture angle of the Cu-Ni laminate changes from 72 degrees to 50 degrees. Cross-sectional observations reveal that the fracture of the Ni layers transforms from opening to shear mode as the layer thickness decreases while that of the Cu layers keeps shear mode. Competition mechanisms were proposed to understand the variation in fracture mode of the metallic laminate composites associated with length scale.
Resumo:
Berridge's model (e.g. [Berridge KC. Food reward: Brain substrates of wanting and liking. Neurosci Biobehav Rev 1996;20:1–25.; Berridge KC, Robinson T E. Parsing reward. Trends Neurosci 2003;26:507–513.; Berridge KC. Motivation concepts in behavioral neuroscience. Physiol Behav 2004;81:179–209]) outlines the brain substrates thought to mediate food reward with distinct ‘liking’ (hedonic/affective) and ‘wanting’ (incentive salience/motivation) components. Understanding the dual aspects of food reward could throw light on food choice, appetite control and overconsumption. The present study reports the development of a procedure to measure these processes in humans. A computer-based paradigm was used to assess ‘liking’ (through pleasantness ratings) and ‘wanting’ (through forced-choice photographic procedure) for foods that varied in fat (high or low) and taste (savoury or sweet). 60 participants completed the program when hungry and after an ad libitum meal. Findings indicate a state (hungry–satiated)-dependent, partial dissociation between ‘liking’ and ‘wanting’ for generic food categories. In the hungry state, participants ‘wanted’ high-fat savoury > low-fat savoury with no corresponding difference in ‘liking’, and ‘liked’ high-fat sweet > low-fat sweet but did not differ in ‘wanting’ for these foods. In the satiated state, participants ‘liked’, but did not ‘want’, high-fat savoury > low-fat savoury, and ‘wanted’ but did not ‘like’ low-fat sweet > high-fat sweet. More differences in ‘liking’ and ‘wanting’ were observed when hungry than when satiated. This procedure provides the first step in proof of concept that ‘liking’ and ‘wanting’ can be dissociated in humans and can be further developed for foods varying along different dimensions. Other experimental procedures may also be devised to separate ‘liking’ and ‘wanting’.
Resumo:
Confirmatory factor analyses were conducted to evaluate the factorial validity of the Toronto Alexithymia Scale in an alcohol-dependent sample. Several factor models were examined, but all models were rejected given their poor fit. A revision of the TAS-20 in alcohol-dependent populations may be needed.