217 resultados para Head tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the eye and head movements and lane-keeping of drivers with hemianopia and quadrantanopia with that of age-matched controls when driving under real world conditions. Methods: Participants included 22 hemianopes and 8 quadrantanopes (M age 53 yrs) and 30 persons with normal visual fields (M age 52 yrs) who were ≥ 6 months from the brain injury date and either a current driver or aiming to resume driving. All participants drove an instrumented dual-brake vehicle along a 14-mile route in traffic that included non-interstate city driving and interstate driving. Driving performance was scored using a standardised assessment system by two “backseat” raters and the Vigil Vanguard system which provides objective measures of speed, braking and acceleration, cornering, and video-based footage from which eye and head movements and lane-keeping can be derived. Results: As compared to drivers with normal visual fields, drivers with hemianopia or quadrantanopia on average were significantly more likely to drive slower, to exhibit less excessive cornering forces or acceleration, and to execute more shoulder movements off the seat. Those hemianopic and quadrantanopic drivers rated as safe to drive by the backseat evaluator made significantly more excursive eye movements, exhibited more stable lane positioning, less sudden braking events and drove at higher speeds than those rated as unsafe, while there was no difference between safe and unsafe drivers in head movements. Conclusions: Persons with hemianopic and quadrantanopic field defects rated as safe to drive have different driving characteristics compared to those rated as unsafe when assessed using objective measures of driving performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate whether wearing different presbyopic vision corrections alters the pattern of eye and head movements when viewing dynamic driving-related traffic scenes. Methods: Participants included 20 presbyopes (mean age: 56±5.7 years) who had no experience of wearing presbyopic vision corrections (i.e. all were single vision wearers). Eye and head movements were recorded while wearing five different vision corrections: single vision lenses (SV), progressive addition spectacle lenses (PALs), bifocal spectacle lenses (BIF), monovision (MV) and multifocal contact lenses (MTF CL) in random order. Videotape recordings of traffic scenes of suburban roads and expressways (with edited targets) were presented as dynamic driving-related stimuli and digital numeric display panels included as near visual stimuli (simulating speedometer and radio). Eye and head movements were recorded using the faceLAB™ system and the accuracy of target identification was also recorded. Results: The magnitude of eye movements while viewing the driving-related traffic scenes was greater when wearing BIF and PALs than MV and MTF CL (p≤0.013). The magnitude of head movements was greater when wearing SV, BIF and PALs than MV and MTF CL (p<0.0001) and the number of saccades was significantly higher for BIF and PALs than MV (p≤0.043). Target recognition accuracy was poorer for all vision corrections when the near stimulus was located at eccentricities inferiorly and to the left, rather than directly below the primary position of gaze (p=0.008), and PALs gave better performance than MTF CL (p=0.043). Conclusions: Different presbyopic vision corrections alter eye and head movement patterns. In particular, the larger magnitude of eye and head movements and greater number of saccades associated with the spectacle presbyopic corrections, may impact on driving performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Identifying an individual from surveillance video is a difficult, time consuming and labour intensive process. The proposed system aims to streamline this process by filtering out unwanted scenes and enhancing an individual's face through super-resolution. An automatic face recognition system is then used to identify the subject or present the human operator with likely matches from a database. A person tracker is used to speed up the subject detection and super-resolution process by tracking moving subjects and cropping a region of interest around the subject's face to reduce the number and size of the image frames to be super-resolved respectively. In this paper, experiments have been conducted to demonstrate how the optical flow super-resolution method used improves surveillance imagery for visual inspection as well as automatic face recognition on an Eigenface and Elastic Bunch Graph Matching system. The optical flow based method has also been benchmarked against the ``hallucination'' algorithm, interpolation methods and the original low-resolution images. Results show that both super-resolution algorithms improved recognition rates significantly. Although the hallucination method resulted in slightly higher recognition rates, the optical flow method produced less artifacts and more visually correct images suitable for human consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-speed broadband internet access is widely recognised as a catalyst to social and economic development, having a significant impact on global economy. Rural Australia’s inherent dispersed population over a large geographical area make the delivery of efficient, well-maintained and cost-effective internet a challenging task. The novel and highly-efficient Multi-User-Single-Antenna for MIMO (MUSA-MIMO) broadband wireless communication technology can effectively be used to deliver wireless broadband access to rural areas. This research aims to develop for the first time, an efficient and accurate algorithm for the tracking and prediction of Channel State Information (CSI) at the transmitter, by characterising time variation effects of the wireless communication channel on the performance of a highly-efficient MUSA-MIMO technology particularly suited for rural communities, improving their quality of life and economic prosperity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper, which serves as an introduction to the mini-symposium on Real-Time Vision, Tracking and Control, provides a broad sketch of visual servoing, the application of real-time vision, tracking and control for robot guidance. It outlines the basic theoretical approaches to the problem, describes a typical architecture, and discusses major milestones, applications and the significant vision sub-problems that must be solved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Machine vision represents a particularly attractive solution for sensing and detecting potential collision-course targets due to the relatively low cost, size, weight, and power requirements of the sensors involved (as opposed to radar). This paper describes the development and evaluation of a vision-based collision detection algorithm suitable for fixed-wing aerial robotics. The system was evaluated using highly realistic vision data of the moments leading up to a collision. Based on the collected data, our detection approaches were able to detect targets at distances ranging from 400m to about 900m. These distances (with some assumptions about closing speeds and aircraft trajectories) translate to an advanced warning of between 8-10 seconds ahead of impact, which approaches the 12.5 second response time recommended for human pilots. We make use of the enormous potential of graphic processing units to achieve processing rates of 30Hz (for images of size 1024-by- 768). Currently, integration in the final platform is under way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the implementation of a modified particle filter for vision-based simultaneous localization and mapping of an autonomous robot in a structured indoor environment. Through this method, artificial landmarks such as multi-coloured cylinders can be tracked with a camera mounted on the robot, and the position of the robot can be estimated at the same time. Experimental results in simulation and in real environments show that this approach has advantages over the extended Kalman filter with ambiguous data association and various levels of odometric noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Velocity Sourced Series Elastic Actuator has been proposed as a method for providing safe force or torque based actuation for robots without compromising the actuator performance. In this paper we assess the safety of Velocity Sourced Series Elastic Actuators by measuring the Head Injury Criterion scores for collisions with a model head. The study makes a comparative analysis against stiff, high impedance actuation using the same motor without the series elastic component, showing that the series elastic component brings about a massive reduction in the chance of head injury. The benefits of a collision detection and safe reaction system are shown to be limited to collisions at low speeds, providing greater interaction comfort but not necessarily contributing to safety from injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustically, car cabins are extremely noisy and as a consequence audio-only, in-car voice recognition systems perform poorly. As the visual modality is immune to acoustic noise, using the visual lip information from the driver is seen as a viable strategy in circumventing this problem by using audio visual automatic speech recognition (AVASR). However, implementing AVASR requires a system being able to accurately locate and track the drivers face and lip area in real-time. In this paper we present such an approach using the Viola-Jones algorithm. Using the AVICAR [1] in-car database, we show that the Viola- Jones approach is a suitable method of locating and tracking the driver’s lips despite the visual variability of illumination and head pose for audio-visual speech recognition system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a novel experiment in which two very different methods of underwater robot localization are compared. The first method is based on a geometric approach in which a mobile node moves within a field of static nodes, and all nodes are capable of estimating the range to their neighbours acoustically. The second method uses visual odometry, from stereo cameras, by integrating scaled optical flow. The fundamental algorithmic principles of each localization technique is described. We also present experimental results comparing acoustic localization with GPS for surface operation, and a comparison of acoustic and visual methods for underwater operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes some new wireless sensor hardware developed for pastoral and environmental applications. From our early experiments with Mote hardware we were inspired to develop our devices with improved radio range, solar power capability, mechanical and electrical robustness, and with unique combinations of sensors. Here we describe the design and evolution of a small family of devices: radio/processor board, a soil moisture sensor interface, and a single board multi-sensor unit for animal tracking experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a technique for tracking road edges in a panoramic image sequence. The major contribution is that instead of unwarping the image to find parallel lines representing the road edges, we choose to warp the parallel groundplane lines into the image plane of the equiangular panospheric camera. Updating the parameters of the line thus involves searching a very small number of pixels in the panoramic image, requiring considerably less computation than unwarping. Results using real-world images, including shadows, intersections and curves, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intelligent surveillance systems typically use a single visual spectrum modality for their input. These systems work well in controlled conditions, but often fail when lighting is poor, or environmental effects such as shadows, dust or smoke are present. Thermal spectrum imagery is not as susceptible to environmental effects, however thermal imaging sensors are more sensitive to noise and they are only gray scale, making distinguishing between objects difficult. Several approaches to combining the visual and thermal modalities have been proposed, however they are limited by assuming that both modalities are perfuming equally well. When one modality fails, existing approaches are unable to detect the drop in performance and disregard the under performing modality. In this paper, a novel middle fusion approach for combining visual and thermal spectrum images for object tracking is proposed. Motion and object detection is performed on each modality and the object detection results for each modality are fused base on the current performance of each modality. Modality performance is determined by comparing the number of objects tracked by the system with the number detected by each mode, with a small allowance made for objects entering and exiting the scene. The tracking performance of the proposed fusion scheme is compared with performance of the visual and thermal modes individually, and a baseline middle fusion scheme. Improvement in tracking performance using the proposed fusion approach is demonstrated. The proposed approach is also shown to be able to detect the failure of an individual modality and disregard its results, ensuring performance is not degraded in such situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the reliability and validity of a palm-top-based electronic appetite rating system (EARS) in relation to the traditional paper and pen method. Twenty healthy subjects [10 male (M) and 10 female (F)] — mean age M=31 years (S.D.=8), F=27 years (S.D.=5); mean BMI M=24 (S.D.=2), F=21 (S.D.=5) — participated in a 4-day protocol. Measurements were made on days 1 and 4. Subjects were given paper and an EARS to log hourly subjective motivation to eat during waking hours. Food intake and meal times were fixed. Subjects were given a maintenance diet (comprising 40% fat, 47% carbohydrate and 13% protein by energy) calculated at 1.6×Resting Metabolic Rate (RMR), as three isoenergetic meals. Bland and Altman's test for bias between two measurement techniques found significant differences between EARS and paper and pen for two of eight responses (hunger and fullness). Regression analysis confirmed that there were no day, sex or order effects between ratings obtained using either technique. For 15 subjects, there was no significant difference between results, with a linear relationship between the two methods that explained most of the variance (r2 ranged from 62.6 to 98.6). The slope for all subjects was less than 1, which was partly explained by a tendency for bias at the extreme end of results on the EARS technique. These data suggest that the EARS is a useful and reliable technique for real-time data collection in appetite research but that it should not be used interchangeably with paper and pen techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present paper reviews the reliability and validity of visual analogue scales (VAS) in terms of (1) their ability to predict feeding behaviour, (2) their sensitivity to experimental manipulations, and (3) their reproducibility. VAS correlate with, but do not reliably predict, energy intake to the extent that they could be used as a proxy of energy intake. They do predict meal initiation in subjects eating their normal diets in their normal environment. Under laboratory conditions, subjectively rated motivation to eat using VAS is sensitive to experimental manipulations and has been found to be reproducible in relation to those experimental regimens. Other work has found them not to be reproducible in relation to repeated protocols. On balance, it would appear, in as much as it is possible to quantify, that VAS exhibit a good degree of within-subject reliability and validity in that they predict with reasonable certainty, meal initiation and amount eaten, and are sensitive to experimental manipulations. This reliability and validity appears more pronounced under the controlled (but more arti®cial) conditions of the laboratory where the signal : noise ratio in experiments appears to be elevated relative to real life. It appears that VAS are best used in within-subject, repeated-measures designs where the effect of different treatments can be compared under similar circumstances. They are best used in conjunction with other measures (e.g. feeding behaviour, changes in plasma metabolites) rather than as proxies for these variables. New hand-held electronic appetite rating systems (EARS) have been developed to increase reliability of data capture and decrease investigator workload. Recent studies have compared these with traditional pen and paper (P&P) VAS. The EARS have been found to be sensitive to experimental manipulations and reproducible relative to P&P. However, subjects appear to exhibit a signi®cantly more constrained use of the scale when using the EARS relative to the P&P. For this reason it is recommended that the two techniques are not used interchangeably