44 resultados para FAR DETECTOR
Resumo:
Introduction Since 1992 there have been several articles published on research on plastic scintillators for use in radiotherapy. Plastic scintillators are said to be tissue equivalent, temperature independent and dose rate independent [1]. Although their properties were found to be promising for measurements in megavoltage X-ray beams there were some technical difficulties with regards to its commercialisation. Standard Imaging has produced the first commercial system which is now available for use in a clinical setting. The Exradin W1 scintillator device uses a dual fibre system where one fibre is connected to the Plastic Scintillator and the other fibre only measures Cerenkov radiation [2]. This paper presents results obtained during commissioning of this dosimeter system. Methods All tests were performed on a Novalis Tx linear accelerator equipped with a 6 MV SRS photon beam and conventional 6 and 18 MV X-ray beams. The following measurements were performed in a Virtual Water phantom at a depth of dose maximum. Linearity: The dose delivered was varied between 0.2 and 3.0 Gy for the same field conditions. Dose rate dependence: For this test the repetition rate of the linac was varied between 100 and 1,000 MU/min. A nominal dose of 1.0 Gy was delivered for each rate. Reproducibility: A total of five irradiations for the same setup. Results The W1 detector gave a highly linear relationship between dose and the number of Monitor Units delivered for a 10 9 10 cm2 field size at a SSD of 100 cm. The linearity was within 1 % for the high dose end and about 2 % for the very low dose end. For the dose rate dependence, the dose measured as a function of repetition the rate (100–1,000 MU/min) gave a maximum deviation of 0.9 %. The reproducibility was found to be better than 0.5 %. Discussion and conclusions The results for this system look promising so far being a new dosimetry system available for clinical use. However, further investigation is needed to produce a full characterisation prior to use in megavoltage X-ray beams.
Resumo:
Introduction The consistency of measuring small field output factors is greatly increased by reporting the measured dosimetric field size of each factor, as opposed to simply stating the nominal field size [1] and therefore requires the measurement of cross-axis profiles in a water tank. However, this makes output factor measurements time consuming. This project establishes at which field size the accuracy of output factors are not affected by the use of potentially inaccurate nominal field sizes, which we believe establishes a practical working definition of a ‘small’ field. The physical components of the radiation beam that contribute to the rapid change in output factor at small field sizes are examined in detail. The physical interaction that dominates the cause of the rapid dose reduction is quantified, and leads to the establishment of a theoretical definition of a ‘small’ field. Methods Current recommendations suggest that radiation collimation systems and isocentre defining lasers should both be calibrated to permit a maximum positioning uncertainty of 1 mm [2]. The proposed practical definition for small field sizes is as follows: if the output factor changes by ±1.0 % given a change in either field size or detector position of up to ±1 mm then the field should be considered small. Monte Carlo modelling was used to simulate output factors of a 6 MV photon beam for square fields with side lengths from 4.0 to 20.0 mm in 1.0 mm increments. The dose was scored to a 0.5 mm wide and 2.0 mm deep cylindrical volume of water within a cubic water phantom, at a depth of 5 cm and SSD of 95 cm. The maximum difference due to a collimator error of ±1 mm was found by comparing the output factors of adjacent field sizes. The output factor simulations were repeated 1 mm off-axis to quantify the effect of detector misalignment. Further simulations separated the total output factor into collimator scatter factor and phantom scatter factor. The collimator scatter factor was further separated into primary source occlusion effects and ‘traditional’ effects (a combination of flattening filter and jaw scatter etc.). The phantom scatter was separated in photon scatter and electronic disequilibrium. Each of these factors was plotted as a function of field size in order to quantify how each affected the change in small field size. Results The use of our practical definition resulted in field sizes of 15 mm or less being characterised as ‘small’. The change in field size had a greater effect than that of detector misalignment. For field sizes of 12 mm or less, electronic disequilibrium was found to cause the largest change in dose to the central axis (d = 5 cm). Source occlusion also caused a large change in output factor for field sizes less than 8 mm. Discussion and conclusions The measurement of cross-axis profiles are only required for output factor measurements for field sizes of 15 mm or less (for a 6 MV beam on Varian iX linear accelerator). This is expected to be dependent on linear accelerator spot size and photon energy. While some electronic disequilibrium was shown to occur at field sizes as large as 30 mm (the ‘traditional’ definition of small field [3]), it has been shown that it does not cause a greater change than photon scatter until a field size of 12 mm, at which point it becomes by far the most dominant effect.
Resumo:
Established Monte Carlo user codes BEAMnrc and DOSXYZnrc permit the accurate and straightforward simulation of radiotherapy experiments and treatments delivered from multiple beam angles. However, when an electronic portal imaging detector (EPID) is included in these simulations, treatment delivery from non-zero beam angles becomes problematic. This study introduces CTCombine, a purpose-built code for rotating selected CT data volumes, converting CT numbers to mass densities, combining the results with model EPIDs and writing output in a form which can easily be read and used by the dose calculation code DOSXYZnrc...
Resumo:
Purpose: To investigate the changes in axial length with the combined effect of accommodation and angle of gaze (convergence and downward gaze) over 5 minutes in groups of myopes and emmetropes. Methods: A total of 31 subjects (nine emmetropes, 10 low myopes, and 12 moderate to high myopes) aged from 18 to 31 years were recruited. To measure ocular biometrics in inferonasal gaze with accommodation, an optical biometer (Lenstar LS900) was inclined on a tilt and height adjustable stage, with the subject’s chinrest mounted on a rotary stage to induce various levels of convergence by rotation of the subject’s head in primary or downward gaze. Initially, the subjects performed a distance viewing task in primary gaze for 10 minutes to provide a ‘wash-out’ period for prior visual tasks, and then the subject’s axial length and ocular biometrics were measured in nine different combinations of gaze/accommodation over 5 minutes. These nine sessions for all gaze measurements (i.e. three levels of accommodation 9 three levels of convergence) were completed across 3 days of testing (one accommodation condition on each day).The nine combinations of gaze/accommodation were based on those required to view the centre, right and left edges of a distant TV at 6 m in primary gaze, an intermediate task (i.e. computer at 50 cm in 10° downward gaze) and a near task (i.e. reading A4 page at 20 cm in 20° downward gaze). Subjects were wearing a custom built three-axes head tracker throughout the experiment that monitored subjects’ relative head movements (roll, pitch and yaw) during measurements. Results: A significant increase in axial length occurred with the combined effect of accommodation, convergence and downward gaze (repeated measures ANOVA, p < 0.001), with the greatest axial elongation during the near task in downward gaze with convergence (i.e. downward 20°/inward 33°, with 5 D accommodation) (mean change 33 ± 13 lm, after 5 minutes task) followed by the intermediate task (i.e. downward 10°/inward 25°, with 2 D accommodation) (mean change 14 ± 11 lm, after 5 minutes task).Changes in axial length for the distance task (i.e. primary gaze/9° convergence, with 0.16 D accommodation) were not statistically significant (mean change 4 ± 8 lm, after 5 minutes task, p > 0.05). Moderate to high myopes had a greater change in the axial length (mean change 40 ± 11 lm after 5 minutes of near task) than that of emmetropes (mean change 29 ± 15 lm after 5 minutes of near task) and low myopes (mean change 29 ± 16 lm after 5 minutes of near task) associated with time (p = 0.02) and accommodation by time (p = 0.03). Conclusions: The combination of accommodation, convergence and downward angle has a significant short term effect on axial length over time. The near task in downward gaze with convergence caused a greater change in axial length than the intermediate and distant visual tasks. The greater axial elongation measured in the infero-nasal direction with accommodation is most likely associated with a combination of biomechanical factors such as, extraocular muscle forces and ciliary muscle contraction.
Resumo:
Purpose Small field x-ray beam dosimetry is difficult due to a lack of lateral electronic equilibrium, source occlusion, high dose gradients and detector volume averaging. Currently there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Methods Small field sizes were defined by BrainLAB circular cones (4 – 30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated by Monte Carlo methods using BEAMnrc and correction factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Results For the small fields of 4 to 30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Conclusions We conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.
Resumo:
With the increasing need to adapt to new environments, data-driven approaches have been developed to estimate terrain traversability by learning the rover’s response on the terrain based on experience. Multiple learning inputs are often used to adequately describe the various aspects of terrain traversability. In a complex learning framework, it can be difficult to identify the relevance of each learning input to the resulting estimate. This paper addresses the suitability of each learning input by systematically analyzing the impact of each input on the estimate. Sensitivity Analysis (SA) methods provide a means to measure the contribution of each learning input to the estimate variability. Using a variance-based SA method, we characterize how the prediction changes as one or more of the input changes, and also quantify the prediction uncertainty as attributed from each of the inputs in the framework of dependent inputs. We propose an approach built on Analysis of Variance (ANOVA) decomposition to examine the prediction made in a near-to-far learning framework based on multi-task GP regression. We demonstrate the approach by analyzing the impact of driving speed and terrain geometry on the prediction of the rover’s attitude and chassis configuration in a Marsanalogue terrain using our prototype rover Mawson.
Resumo:
The distribution of a freshwater species is often dependent on its ability to disperse within the riverine system. Species with high dispersal abilities tend to be widespread, whereas those with restricted dispersal tend to be geographically restricted and are usually given higher conservation priority. Population structure was compared between a widespread freshwater prawn species, Macrobrachium australiense, and a narrow-range endemic freshwater prawn, Macrobrachium koombooloomba. The distribution of M. australiense and M. koombooloomba did not overlap, although suggested historical river-boundary rearrangements indicate that there has been the potential for dispersal into neighbouring catchments. A fragment of the mtDNA CO1 gene was analysed and a Mantel test revealed a significant isolation by distance effect for both species. Significant overall FST values confirmed that both species exhibited low levels of dispersal, a prediction for populations inhabiting a fragmented upland environment. The level of structure in M. australiense is surprising for a widely distributed species. Not all M. australiense populations conformed to the stream-hierarchy model, with results being best explained by historical river realignment or cross-catchment dispersal. The fact that both species show limited dispersal highlights the importance of conservation in highland areas for both endemic and widely spread species.
Resumo:
This paper is a qualitative, practice based study describing the use of the Focus-Action-Reflection (FAR) Guide (Harrison and Treagust, 2000) to address the shortcomings of a pedagogical analogical model in Year 10 Science. The aim of this paper is to present my experience of the FAR Guide in relation to an analogical model that gave rise to perceived shortcomings by both teachers and students. This study found the FAR Guide to be a highly valuable tool, transforming the presentation of the analogical model, and enabling students to develop a deeper understanding of the nature of scientific knowledge.
Resumo:
Purpose In response to the threat that drink drivers pose to themselves and others, drink driving programs form an important part of a suite of countermeasures used in Australia and internationally. Unlike New Zealand/Aotearoa, United States and Canada that have programs catering for their First Peoples, all Australian programs are designed for the general driver population. The aim of this study was to identify the factors that contribute to Indigenous drink driving in order to inform appropriate recommendations related to developing a community-based program for Indigenous communities. Broader drivers licensing policy recommendations are also discussed. Methods A sample of 73 Indigenous people from Queensland and in New South Wales with one or more drink driving convictions completed a semi-structured interview in respect of the to their drink driving behaviour. Participants were asked to disclose information regarding their drink driving history, and alcohol and drug use. If participants self-reported no longer drink driving, they were probed about what factors had assisted them to avoid further offending. Results Key themes which emerged to maintain drink driving include motivations to drink and drive, and belief in the ability to manage the associated risks. Factors that appeared to support others from avoiding further offending include re-connecting with culture and family support. Conclusions and Implications A range of recommendations regarding delivery and content of a program for regional and remote communities as well as other policy implications are discussed.
Resumo:
In response to the threat that drink drivers pose to themselves and others, drink driving programs form an important part of a suite of countermeasures used in Australia and internationally. Unlike New Zealand/Aotearoa, United States and Canada that have programs catering for their First Peoples, all Australian programs are designed for the general driver population. The aim of this study was to identify the factors that contribute to Indigenous drink driving in order to inform appropriate recommendations related to developing a community-based program for Indigenous communities. Broader drivers licensing policy recommendations are also discussed. A sample of 73 Indigenous people from Queensland and in New South Wales with one or more drink driving convictions completed a semi-structured interview regarding their drink driving behaviour. Participants were asked to disclose information regarding their drink driving history, and alcohol and drug use. If participants self-reported no longer drink driving, they were probed about what factors had assisted them to avoid further offending. Key themes which emerged to maintain drink driving include motivations to drink and drive, and belief in the ability to manage the associated risks. Factors that appeared to support others from avoiding further offending include re-connecting with culture and family support. A range of recommendations regarding delivery and content of a program for regional and remote communities as well as other policy implications are discussed.
Resumo:
Issue addressed: Alcohol-related road crashes are a leading cause of the injury burden experienced by Indigenous Australians. Existing drink driving programs are primarily designed for the mainstream population. The ‘Hero to Healing’ program was specifically developed with Indigenous communities and is underpinned by the Community Reinforcement Approach (CRA). This paper reports on the formative evaluation of the program from delivery in two Far North Queensland communities. Methods: Focus groups and semistructured interviews were conducted with drink driver participants (n = 17) and other Elders and community members (n = 8) after each program. Qualitative content analysis was used to categorise the transcripts. Results: The CRA appealed to participants because of its flexible nature and encouragement of rearranging lifestyle factors, without specific focus on alcohol use. Participants readily identified with the social and peer-related risk and protective factors discussed. Cofacilitation of the program with Elders was identified as a key aspect of the program. More in-depth discussion about cannabis and driving, anger management skills and relationship issues are recommended. Conclusions: Participants’ recognition of content reinforced earlier project results, particularly the use of kinship pressure to motivate younger family members to drink drive. Study findings suggest that the principles of the CRA are useful; however, some amendments to the CRA components and program content were necessary. So what?: Treating drink driving in regional and remote Indigenous Australian communities as a community and social issue, rather than an individual phenomenon, is likely to lead to a reduction in the number of road-related injuries Indigenous people experience.