631 resultados para Medical Field


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethnographic methods have been widely used for requirements elicitation purposes in systems design, especially when the focus is on understanding users? social, cultural and political contexts. Designing an on-line search engine for peer-reviewed papers could be a challenge considering the diversity of its end users coming from different educational and professional disciplines. This poster describes our exploration of academic research environments based on different in situ methods such as contextual interviews, diary-keeping, job-shadowing, etc. The data generated from these methods is analysed using a qualitative data analysis software and subsequently is used for developing personas that could be used as a requirements specification tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Since 1992 there have been several articles published on research on plastic scintillators for use in radiotherapy. Plastic scintillators are said to be tissue equivalent, temperature independent and dose rate independent [1]. Although their properties were found to be promising for measurements in megavoltage X-ray beams there were some technical difficulties with regards to its commercialisation. Standard Imaging has produced the first commercial system which is now available for use in a clinical setting. The Exradin W1 scintillator device uses a dual fibre system where one fibre is connected to the Plastic Scintillator and the other fibre only measures Cerenkov radiation [2]. This paper presents results obtained during commissioning of this dosimeter system. Methods All tests were performed on a Novalis Tx linear accelerator equipped with a 6 MV SRS photon beam and conventional 6 and 18 MV X-ray beams. The following measurements were performed in a Virtual Water phantom at a depth of dose maximum. Linearity: The dose delivered was varied between 0.2 and 3.0 Gy for the same field conditions. Dose rate dependence: For this test the repetition rate of the linac was varied between 100 and 1,000 MU/min. A nominal dose of 1.0 Gy was delivered for each rate. Reproducibility: A total of five irradiations for the same setup. Results The W1 detector gave a highly linear relationship between dose and the number of Monitor Units delivered for a 10 9 10 cm2 field size at a SSD of 100 cm. The linearity was within 1 % for the high dose end and about 2 % for the very low dose end. For the dose rate dependence, the dose measured as a function of repetition the rate (100–1,000 MU/min) gave a maximum deviation of 0.9 %. The reproducibility was found to be better than 0.5 %. Discussion and conclusions The results for this system look promising so far being a new dosimetry system available for clinical use. However, further investigation is needed to produce a full characterisation prior to use in megavoltage X-ray beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The dose to skin surface is an important factor for many radiotherapy treatment techniques. It is known that TPS predicted surface doses can be significantly different from actual ICRP skin doses as defined at 70 lm. A number of methods have been implemented for the accurate determination of surface dose including use of specific dosimeters such as TLDs and radiochromic film as well as Monte Carlo calculations. Stereotactic radiosurgery involves delivering very high doses per treatment fraction using small X-ray fields. To date, there has been limited data on surface doses for these very small field sizes. The purpose of this work is to evaluate surface doses by both measurements and Monte Carlo calculations for very small field sizes. Methods All measurements were performed on a Novalis Tx linear accelerator which has a 6 MV SRS X-ray beam mode which uses a specially thin flattening filter. Beam collimation was achieved by circular cones with apertures that gave field sizes ranging from 4 to 30 mm at the isocentre. The relative surface doses were measured using Gafchromic EBT3 film which has the active layer at a depth similar to the ICRP skin dose depth. Monte Carlo calculations were performed using the BEAMnrc/EGSnrc Monte Carlo codes (V4 r225). The specifications of the linear accelerator, including the collimator, were provided by the manufacturer. Optimisation of the incident X-ray beam was achieved by an iterative adjustment of the energy, spatial distribution and radial spread of the incident electron beam striking the target. The energy cutoff parameters were PCUT = 0.01 MeV and ECUT = 0.700 - MeV. Directional bremsstrahlung splitting was switched on for all BEAMnrc calculations. Relative surface doses were determined in a layer defined in a water phantom of the same thickness and depth as compared to the active later in the film. Results Measured surface doses using the EBT3 film varied between 13 and 16 % for the different cones with an uncertainty of 3 %. Monte Carlo calculated surface doses were in agreement to better than 2 % to the measured doses for all the treatment cones. Discussion and conclusions This work has shown the consistency of surface dose measurements using EBT3 film with Monte Carlo predicted values within the uncertainty of the measurements. As such, EBT3 film is recommended for in vivo surface dose measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study investigated the sensitivity of calculated stereotactic radiotherapy and radiosurgery doses to the accuracy of the beam data used by the treatment planning system. Methods Two sets of field output factors were acquired using fields smaller than approximately 1 cm2, for inclusion in beam data used by the iPlan treatment planning system (Brainlab, Feldkirchen, Germany). One set of output factors were measured using an Exradin A16 ion chamber (Standard Imaging, Middleton, USA). Although this chamber has a relatively small collecting volume (0.007 cm3), measurements made in small fields using this chamber are subject to the effects of volume averaging, electronic disequilibrium and chamber perturbations. The second, more accurate, set of measurements were obtained by applying perturbation correction factors, calculated using Monte Carlo simulations according to a method recommended by Cranmer-Sargison et al. [1] to measurements made using a 60017 unshielded electron diode (PTW, Freiburg, Germany). A series of 12 sample patient treatments were used to investigate the effects of beam data accuracy on resulting planned dose. These treatments, which involved 135 fields, were planned for delivery via static conformal arcs and 3DCRT techniques, to targets ranging from prostates (up to 8 cm across) to meningiomas (usually more than 2 cm across) to arterioveinous malformations, acoustic neuromas and brain metastases (often less than 2 cm across). Isocentre doses were calculated for all of these fields using iPlan, and the results of using the two different sets of beam data were evaluated. Results While the isocentre doses for many fields are identical (difference = 0.0 %), there is a general trend for the doses calculated using the data obtained from corrected diode measurements to exceed the doses calculated using the less-accurate Exradin ion chamber measurements (difference\0.0 %). There are several alarming outliers (circled in the Fig. 1) where doses differ by more than 3 %, in beams from sample treatments planned for volumes up to 2 cm across. Discussion and conclusions These results demonstrate that treatment planning dose calculations for SRT/SRS treatments can be substantially affected when beam data for fields smaller than approximately 1 cm2 are measured inaccurately, even when treatment volumes are up to 2 cm across.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stereotactic radiosurgery (SRS) treatments for brain cancers require small and precisely shaped photon beams. These beams can be generated by fitting a linear accelerator with a micro-multileaf collimator (mMLC) such as the BrainLAB m3, which offers greater flexibility for field shaping than standard SRS cone collimators

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this review is to address important methodological issues related to conducting accelerometer-based assessments of physical activity in free-living individuals. Methods We review the extant scientific literature for empirical information related to the following issues: product selection, number of accelerometers needed, placement of accelerometers, epoch length, and days of monitoring required to estimate habitual physical activity. We also discuss the various options related to distributing and collecting monitors and strategies to enhance compliance with the monitoring protocol. Results No definitive evidence exists currently to indicate that one make and model of accelerometer is more valid and reliable than another. Selection of accelerometer therefore remains primarily an issue of practicality, technical support, and comparability with other studies. Studies employing multiple accelerometers to estimate energy expenditure report only marginal improvements in explanatory power. Accelerometers are best placed on hip or the lower back. Although the issue of epoch length has not been studied in adults, the use of count cut points based on 1-min time intervals maybe inappropriate in children and may result in underestimation of physical activity. Among adults, 3–5 d of monitoring is required to reliably estimate habitual physical activity. Among children and adolescents, the number of monitoring days required ranges from 4 to 9 d, making it difficult to draw a definitive conclusion for this population. Face-to-face distribution and collection of accelerometers is probably the best option in field-based research, but delivery and return by express carrier or registered mail is a viable option. Conclusion Accelerometer-based activity assessments requires careful planning and the use of appropriate strategies to increase compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is concerned with understanding the roles of four alternate healing systems and medical practice in the community's health behaviour. The four alternate systems are naturopathy, homoeopathy, osteopathy and chiropractic. The research reported developed from work supported by the Committee of Inquiry into Chiropractic, Osteopathy, Homoeopathy and Naturopathy conducted under the chairmanship of Professor E. C. Webb set up by the Australian Government in 1975. The study concentrates on the factors which influence individual clients in their decisions to consult healers for treatment. An underlying assumption is that an analysis of the processes that effect such decisions will lead to further knowledge of the community's attitudes towards the functions of alternate healing and medicine. A review of the historical backgrounds and current status of the four alternate healing systems leads to the conclusion that they differ in a variety of areas. These areas include treatment modalities, historical backgrounds, occupational development and rapprochement with medicine. Homoeopathy, osteopathy and chiropractic emerged as distinct approaches to healing late in the nineteenth century. Naturopathy tends to be a philosophy or style of life as much as a health system in its own right. Their relationships with medicine also vary; osteopathy and naturopathy receive some acceptance, some homoeopaths are tolerated, whilst chiropractic is ostracised and vilified. A common paradigm of treatment underlies all four alternate approaches to healing. They all eschew the use of synthetic pharmaceuticals and invasive treatments and accept an indigenous theory of disease and a belief in the vis medicatrix naturae or the healing power of nature. An inevitable concomitant of this paradigm is that they believe that healing and health must be self-engendered. They rest within the client and his or her actions, not within the hands, skills or power of the healer. It is these characteristics combined with the alternate healers ' claims to espouse a similar scientific rationale for their approaches, and their functioning as parallel healers to medicine, that establishes their special relationship with medicine. This relationship become s more problematic in the face of medicine's hegemony and claim to unique legitimacy as the community's sole healing system. The interaction between these systems and medical practice can be gauged through articles related to the four alternate healing systems that have appeared in the medical literature. Interest has been cyclical but appears to have markedly increased in the past two decades. In this period it has included exploratory and descriptive writing; concern with controlling and/or eradicating the healers; desire to protect an ignorant and vulnerable public and. finally understanding and exploration of what the alternate healers might have to offer. At the same time, the public or institutionalized role has been one of denial and suppression through ostracism and legal constraints. In spite of medicine's position the alternate healing systems have found growing community acceptance so that it is problematical and probably unacceptable now to consider their use as a 'deviant ' health action. Increasing interest in the characteristics of clients has provided a consensus that they are similar to the adult population and are more likely to suffer from musculoskeletal and chronic illnesses. They are no more likely to be neurotic or gullible than the general community, but probably more practical and more oriented towards an active involvement in the healing process. The impact of these issues is explored, through comparing the strategies taken into account when choosing a treatment. These include attending one of the alternate healers exclusively for a condition; attending an alternate healer and a medical practitioner for the same problem; attending a medical practitioner solely or not consulting any healer. Respondents from surveys of alternate healer clients and the general community were classified according to their use of these four strategies, and the influences on their decisions at different stages of the treatment decision making process were compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the reliability and validity of field tests for assessing physical function in mid-aged and young-old people (55-70 y). Tests were selected that required minimal space and equipment and could be implemented in multiple field settings such as a general practitioner's office. Nineteen participants completed 2 field and I laboratory testing sessions. Intra-class correlations showed good reliability for the tests of upper body strength (lift and reach, R=.66), lower body strength (sit to stand, R=.80) and functional capacity (Canadian Step Test, R=.92), but not for leg power (single timed chair rise, R=.28). There was also good reliability for the balance test during 3 stances: parallel (94.7% agreement), semi-tandem (73.7%), and tandem (52.6%). Comparison of field test results with objective laboratory measures found good validity for the sit to stand (cf 1RM leg press, Pearson r=.68, p <.05), and for the step test (cf PWC140, r = -.60, p <.001), but not for the lift and reach (cf 1RM bench press, r=.43, p >.05), balance (r=-.13, -.18, .23) and rate of force development tests (r=-.28). It was concluded that the lower body strength and cardiovascular function tests were appropriate for use in field settings with mid-aged and young-old adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Combining facets of health physics with medicine, An Introduction to Radiation Protection in Medicine covers the background of the subject and the medical situations where radiation is the tool to diagnose or treat human disease. Encouraging newcomers to the field to properly and efficiently function in a versatile and evolving work setting, it familiarizes them with the particular problems faced during the application of ionizing radiation in medicine. The text builds a fundamental knowledge base before providing practical descriptions of radiation safety in medicine. It covers basic issues related to radiation protection, including the physical science behind radiation protection and the radiobiological basis of radiation protection. The text also presents operational and managerial tools for organizing radiation safety in a medical workplace. Subsequent chapters form the core of the book, focusing on the practice of radiation protection in different medical disciplines. They explore a range of individual uses of ionizing radiation in various branches of medicine, including radiology, nuclear medicine, external beam radiotherapy, and brachytherapy. With contributions from experienced practicing physicists, this book provides essential information about dealing with radiation safety in the rapidly shifting and diverse environment of medicine."--publisher website

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oral endotracheal tubes (ETTs) and nasogastric tubes (NGT) are common devices used in adult intensive care and numerous options exist for safe and comfortable securement of these devices. The aim of this project was to identify the available range of ETT and NGT securement devices in Australia as a resource for clinicians seeking to explore options for tube stabilisation. This article reports part A of this project: ETT securement options. Part B will report NGT device fixation options. Securing ETTs to ensure a patent airway with minimal ETT movement, promotion of patient comfort and absence of adverse events such as ETT dislodgement, unplanned extubation and device-related injury1, are essential critical care nursing actions. The ETT requires a fixation method that is robust yet does not traumatise or injure the mucosal tissues of the mouth and soft tissue of the lips.2,3 Choice of a securement apparatus is often determined by product availability in our units or hospitals but is also driven by evidence-based practice and clinician preference. Trying to put this information together can be difficult and time-consuming for the bedside clinician...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is the second part of a two-part series examining securement options for commonly used therapeutic devices in the adult intensive care unit. Part A focused on endotracheal device securement.1 This article addresses nasogastric tube (NGT) securement options and with the aim of identifying the available range of NGT securement devices in Australia as a resource for clinicians seeking to explore options for tube stabilisation. Nasogastric feeding or gastric decompression tubes are commonly inserted via the nostril/nares. The National Pressure Ulcer Advisory Panel (NPUAP) 2011 position statement on mucosal pressure injuries, highlighted that mucosal tissues are vulnerable to pressure from devices.2 Securing of these devices sometimes leads to pressure-related injury to the internal mucosa due to difficulty visualising the mucosa and failure to reposition the nasogastric tube to relieve the pressure in a particular area.3 The nasal orifice is much smaller than the oral cavity and regular tube position changes are vital to minimise the risk of mucosal damage and ulcer development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the modeling and motion-sensorless direct torque and flux control of a novel dual-airgap axial-flux permanent-magnet machine optimized for use in flywheel energy storage system (FESS) applications. Independent closed-loop torque and stator flux regulation are performed in the stator flux ( x-y) reference frame via two PI controllers. This facilitates fast torque dynamics, which is critical as far as energy charging/discharging in the FESS is concerned. As FESS applications demand high-speed operation, a new field-weakening algorithm is proposed in this paper. Flux weakening is achieved autonomously once the y-axis voltage exceeds the available inverter voltage. An inherently speed sensorless stator flux observer immune to stator resistance variations and dc-offset effects is also proposed for accurate flux and speed estimation. The proposed observer eliminates the rotary encoder, which in turn reduces the overall weight and cost of the system while improving its reliability. The effectiveness of the proposed control scheme has been verified by simulations and experiments on a machine prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasmonic gold nano-assemblies that self-assemble with the aid of linking molecules or polymers have the potential to yield controlled hierarchies of morphologies and consequently result in materials with tailored optical (e.g. localized surface plasmon resonances (LSPR)) and spectroscopic properties (e.g. surface enhanced Raman scattering (SERS)). Molecular linkers that are structurally well-defined are promising for forming hybrid nano-assemblies which are stable in aqueous solution and are increasingly finding application in nanomedicine. Despite much ongoing research in this field, the precise role of molecular linkers in governing the morphology and properties of the hybrid nano-assemblies remains unclear. Previously we have demonstrated that branched linkers, such as hyperbranched polymers, with specific anchoring end groups can be successfully employed to form assemblies of gold NPs demonstrating near-infrared SPRs and intense SERS scattering. We herein introduce a tailored polymer as a versatile molecular linker, capable of manipulating nano-assembly morphologies and hot-spot density. In addition, this report explores the role of the polymeric linker architecture, specifically the degree of branching of the tailored polymer in determining the formation, morphology and properties of the hybrid nano-assemblies. The degree of branching of the linker polymer, in addition to the concentration and number of anchoring groups, is observed to strongly influence the self-assembly process. The assembly morphology shifts primarily from 1D-like chains to 2D plates and finally to 3D-like globular structures, with increase in degree of branching. Insights have been gained into how the morphology influences the SERS performance of these nano-assemblies with respect to hot-spot density. These findings supplement the understanding of the morphology determining nano-assembly formation and pave the way for the possible application of these nano-assemblies as SERS bio-sensors for medical diagnostics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LexisNexis Questions and Answers: Medical Law is designed to facilitate both continuous review and preparation for assignments and examinations. This book provides a clear and concise revision guide for each of the major topics covered in the typical health law course. It provides an understanding of medical law in each Australian jurisdiction and gives a clear and systematic approach to analysing and answering problem and essay questions. Each chapter commences with an identification of the key issues, including a summary of the relevant cases and legislation. Each question is followed by a suggested answer plan, a sample answer and comments on how the answer might be assessed by an examiner. The author also offers advice on common errors to avoid and practical hints and tips on how to achieve higher marks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Heatwaves could cause the population excess death numbers to be ranged from tens to thousands within a couple of weeks in a local area. An excess mortality due to a special event (e.g., a heatwave or an epidemic outbreak) is estimated by subtracting the mortality figure under ‘normal’ conditions from the historical daily mortality records. The calculation of the excess mortality is a scientific challenge because of the stochastic temporal pattern of the daily mortality data which is characterised by (a) the long-term changing mean levels (i.e., non-stationarity); (b) the non-linear temperature-mortality association. The Hilbert-Huang Transform (HHT) algorithm is a novel method originally developed for analysing the non-linear and non-stationary time series data in the field of signal processing, however, it has not been applied in public health research. This paper aimed to demonstrate the applicability and strength of the HHT algorithm in analysing health data. Methods Special R functions were developed to implement the HHT algorithm to decompose the daily mortality time series into trend and non-trend components in terms of the underlying physical mechanism. The excess mortality is calculated directly from the resulting non-trend component series. Results The Brisbane (Queensland, Australia) and the Chicago (United States) daily mortality time series data were utilized for calculating the excess mortality associated with heatwaves. The HHT algorithm estimated 62 excess deaths related to the February 2004 Brisbane heatwave. To calculate the excess mortality associated with the July 1995 Chicago heatwave, the HHT algorithm needed to handle the mode mixing issue. The HHT algorithm estimated 510 excess deaths for the 1995 Chicago heatwave event. To exemplify potential applications, the HHT decomposition results were used as the input data for a subsequent regression analysis, using the Brisbane data, to investigate the association between excess mortality and different risk factors. Conclusions The HHT algorithm is a novel and powerful analytical tool in time series data analysis. It has a real potential to have a wide range of applications in public health research because of its ability to decompose a nonlinear and non-stationary time series into trend and non-trend components consistently and efficiently.