431 resultados para routine outcome measurement
Resumo:
In this paper, we detail the development of two stakeholder relationships scales. The scales measure major project managers' perceived competence in developing (establishing and maintaining) high quality, effective relationships with stakeholders who are internal and external to their organization. Our sample consists of 373 major project managers from a sub-set of the Australian defense industry. Both the internal stakeholder relationships scale and the external stakeholder relationships scale demonstrated validity and reliability. This research has implications for the interpersonal work relationships literature and the stakeholder management literature. We recommend that researchers test these scales with multiple samples, across different project types and project industries in the future. The stakeholder relationship scales should be versatile enough to be applied to project management generally but are perhaps best suited to major project environments.
Resumo:
Greenhouse gas (GHG) emissions are simultaneously exhausting the world's supply of fossil fuels and threatening the global climate. In many developing countries, significant improvement in living standards in recent years due to the accelerating development of their economies has resulted in a disproportionate increase in household energy consumption. Therefore, a major reduction in household carbon emissions (HCEs) is essential if global carbon reduction targets are to be met. To do this, major Organisation for Economic Co-operation and Development (OECD) states have already implemented policies to alleviate the negative environmental effects of household behaviors and less carbon-intensive technologies are also proposed to promote energy efficiency and reduce carbon emissions. However, before any further remedial actions can be contemplated, though, it is important to fully understand the actual causes of such large HCEs and help researchers both gain deep insights into the development of the research domain and identify valuable research topics for future study. This paper reviews existing literature focusing on the domain of HCEs. This critical review provides a systematic understanding of current work in the field, describing the factors influencing HCEs under the themes of household income, household size, age, education level, location, gender and rebound effects. The main quantification methodologies of input–output models, life cycle assessment and emission coefficient methods are also presented, and the proposed measures to mitigate HCEs at the policy, technology and consumer levels. Finally, the limitations of work done to date and further research directions are identified for the benefit of future studies.
Resumo:
Several new medicines are in development for the treatment of type 2 diabetes, and cardiovascular outcome trials are the gold standard for these medicines. This editorial demonstrates that despite being available for over 10 years, there are no cardiovascular outcome studies for any of the glucagon-like peptide-1 (GLP-1) receptor agonists, which demonstrate cardiovascular safety or benefit in subjects with high cardiovascular risk. The author argues that the FDA should be ensuring that clinical outcome studies for subjects with type 2 diabetes and high cardiovascular risk be undertaken in a timelier manner.
Resumo:
The paper presents an improved Phase-Locked Loop (PLL) for measuring the fundamental frequency and selective harmonic content of a distorted signal. This information can be used by grid interfaced devices and harmonic compensators. The single-phase structure is based on the Synchronous Reference Frame (SRF) PLL. The proposed PLL needs only a limited number of harmonic stages by incorporating Moving Average Filters (MAF) for eliminating the undesired harmonic content at each stage. The frequency dependency of MAF in effective filtering of undesired harmonics is also dealt with by a proposed method for adaptation to frequency variations of input signal. The method is suitable for high sampling rates and a wide frequency measurement range. Furthermore, an extended model of this structure is proposed which includes the response to both the frequency and phase angle variations. The proposed algorithm is simulated and verified using Hardware-in-the-Loop (HIL) testing.
Resumo:
The measurement of radon ((222)Rn) activity flux using activated charcoal canisters was examined to investigate the distribution of the adsorbed (222)Rn in the charcoal bed and the relationship between (222)Rn activity flux and exposure time. The activity flux of (222)Rn from five sources of varying strengths was measured for exposure times of one, two, three, five, seven, 10, and 14 days. The distribution of the adsorbed (222)Rn in the charcoal bed was obtained by dividing the bed into six layers and counting each layer separately after the exposure. (222)Rn activity decreased in the layers that were away from the exposed surface. Nevertheless, the results demonstrated that only a small correction might be required in the actual application of charcoal canisters for activity flux measurement, where calibration standards were often prepared by the uniform mixing of radium ((226)Ra) in the matrix. This was because the diffusion of (222)Rn in the charcoal bed and the detection efficiency as a function of the charcoal depth tended to counterbalance each other. The influence of exposure time on the measured (222)Rn activity flux was observed in two situations of the canister exposure layout: (a) canister sealed to an open bed of the material and (b) canister sealed over a jar containing the material. The measured (222)Rn activity flux decreased as the exposure time increased. The change in the former situation was significant with an exponential decrease as the exposure time increased. In the latter case, lesser reduction was noticed in the observed activity flux with respect to exposure time. This reduction might have been related to certain factors, such as absorption site saturation or the back diffusion of (222)Rn gas occurring at the canister-soil interface.
Resumo:
Background Spanish is one of the five most spoken languages in the world. There is currently no published Spanish version of the Örebro Musculoskeletal Pain Questionnaire (OMPQ). The aim of the present study is to describe the process of translating the OMPQ into Spanish and to perform an analysis of reliability, internal structure, internal consistency and concurrent criterion-related validity. Methods Design: Translation and psychometric testing. Procedure: Two independent translators translated the OMPQ into Spanish. From both translations a consensus version was achieved. A backward translation was made to verify and resolve any semantic or conceptual problems. A total of 104 patients (67 men/37 women) with a mean age of 53.48 (±11.63), suffering from chronic musculoskeletal disorders, twice completed a Spanish version of the OMPQ. Statistical analysis was performed to evaluate the reliability, the internal structure, internal consistency and concurrent criterion-related validity with reference to the gold standard questionnaire SF-12v2. Results All variables except “Coping” showed a rate above 0.85 on reliability. The internal structure calculation through exploratory factor analysis indicated that 75.2% of the variance can be explained with six components with an eigenvalue higher than 1 and 52.1% with only three components higher than 10% of variance explained. In the concurrent criterion-related validity, several significant correlations were seen close to 0.6, exceeding that value in the correlation between general health and total value of the OMPQ. Conclusions The Spanish version of the screening questionnaire OMPQ can be used to identify Spanish patients with musculoskeletal pain at risk of developing a chronic disability.
Resumo:
Purpose – Ideally, there is no wear in hydrodynamic lubrication regime. A small amount of wear occurs during start and stop of the machines and the amount of wear is so small that it is difficult to measure with accuracy. Various wear measuring techniques have been used where out-of-roundness was found to be the most reliable method of measuring small wear quantities in journal bearings. This technique was further developed to achieve higher accuracy in measuring small wear quantities. The method proved to be reliable as well as inexpensive. The paper aims to discuss these issues. Design/methodology/approach – In an experimental study, the effect of antiwear additives was studied on journal bearings lubricated with oil containing solid contaminants. The test duration was too long and the wear quantities achieved were too small. To minimise the test duration, short tests of about 90 min duration were conducted and wear was measured recording changes in variety of parameters related to weight, geometry and wear debris. The out-of-roundness was found to be the most effective method. This method was further refined by enlarging the out-of-roundness traces on a photocopier. The method was proved to be reliable and inexpensive. Findings – Study revealed that the most commonly used wear measurement techniques such as weight loss, roughness changes and change in particle count were not adequate for measuring small wear quantities in journal bearings. Out-of-roundness method with some refinements was found to be one of the most reliable methods for measuring small wear quantities in journal bearings working in hydrodynamic lubrication regime. By enlarging the out-of-roundness traces and determining the worn area of the bearing cross-section, weight loss in bearings was calculated, which was repeatable and reliable. Research limitations/implications – This research is a basic in nature where a rudimentary solution has been developed for measuring small wear quantities in rotary devices such as journal bearings. The method requires enlarging traces on a photocopier and determining the shape of the worn area on an out-of-roundness trace on a transparency, which is a simple but a crude method. This may require an automated procedure to determine the weight loss from the out-of-roundness traces directly. This method can be very useful in reducing test duration and measuring wear quantities with higher precision in situations where wear quantities are very small. Practical implications – This research provides a reliable method of measuring wear of circular geometry. The Talyrond equipment used for measuring the change in out-of-roundness due to wear of bearings indicates that this equipment has high potential to be used as a wear measuring device also. Measurement of weight loss from the traces is an enhanced capability of this equipment and this research may lead to the development of a modified version of Talyrond type of equipment for wear measurements in circular machine components. Originality/value – Wear measurement in hydrodynamic bearings requires long duration tests to achieve adequate wear quantities. Out-of-roundness is one of the geometrical parameters that changes with progression of wear in a circular shape components. Thus, out-of-roundness is found to be an effective wear measuring parameter that relates to change in geometry. Method of increasing the sensitivity and enlargement of out-of-roundness traces is original work through which area of worn cross-section can be determined and weight loss can be derived for materials of known density with higher precision.
Resumo:
Objective: The aim of this study was to develop a model capable of predicting variability in the mental workload experienced by frontline operators under routine and nonroutine conditions. Background: Excess workload is a risk that needs to be managed in safety-critical industries. Predictive models are needed to manage this risk effectively yet are difficult to develop. Much of the difficulty stems from the fact that workload prediction is a multilevel problem. Method: A multilevel workload model was developed in Study 1 with data collected from an en route air traffic management center. Dynamic density metrics were used to predict variability in workload within and between work units while controlling for variability among raters. The model was cross-validated in Studies 2 and 3 with the use of a high-fidelity simulator. Results: Reported workload generally remained within the bounds of the 90% prediction interval in Studies 2 and 3. Workload crossed the upper bound of the prediction interval only under nonroutine conditions. Qualitative analyses suggest that nonroutine events caused workload to cross the upper bound of the prediction interval because the controllers could not manage their workload strategically. Conclusion: The model performed well under both routine and nonroutine conditions and over different patterns of workload variation. Application: Workload prediction models can be used to support both strategic and tactical workload management. Strategic uses include the analysis of historical and projected workflows and the assessment of staffing needs. Tactical uses include the dynamic reallocation of resources to meet changes in demand.
Resumo:
In this paper, the results of the time dispersion parameters obtained from a set of channel measurements conducted in various environments that are typical of multiuser Infostation application scenarios are presented. The measurement procedure takes into account the practical scenarios typical of the positions and movements of the users in the particular Infostation network. To provide one with the knowledge of how much data can be downloaded by users over a given time and mobile speed, data transfer analysis for multiband orthogonal frequency division multiplexing (MB-OFDM) is presented. As expected, the rough estimate of simultaneous data transfer in a multiuser Infostation scenario indicates dependency of the percentage of download on the data size, number and speed of the users, and the elapse time.
Resumo:
Digital media have contributed to significant disruptions in the business of audience measurement. Television broadcasters have long relied on simple and authoritative measures of who is watching what. The demand for ratings data, as a common currency in transactions involving advertising and program content, will likely remain, but accompanying measurements of audience engagement with media content would also be of value. Today's media environment increasingly includes social media and second-screen use, providing a data trail that affords an opportunity to measure engagement. If the limitations of using social media to indicate audience engagement can be overcome, social media use may allow for quantitative and qualitative measures of engagement. Raw social media data must be contextualized, and it is suggested that tools used by sports analysts be incorporated to do so. Inspired by baseball's Sabremetrics, the authors propose Telemetrics in an attempt to separate actual performance from contextual factors. Telemetrics facilitates measuring audience activity in a manner controlling for factors such as time slot, network, and so forth. It potentially allows both descriptive and predictive measures of engagement.
Resumo:
Food retail is known for its use of flexible labour and for the centralisation of functions at head office, resulting in a reduction of managerial autonomy at store level. This article employs a typology of controls developed from labour process scholarship to explore how retail managers negotiate the control of their predominantly part-time workforce. Using an Australian supermarket chain as a case, and mixed methods, the article demonstrates that supermarkets use a multiplicity of forms of control across their workforce. For front line service workers, the article identifies a new configuration of controls which intersects with employment status and acts differentially for checkout operators on different employment contracts.
Resumo:
Background: Many preterm neonates display difficulty establishing suck-feeding competence in the weeks following birth. Ineffective management of transitional feeding issues may cause patient complications, and can contribute to increased length of stay. Aims: Given that many neonatal nurseries appear to vary in their neonatal feeding management practices, the aim of this study was to investigate and document the routine level of support and intervention currently provided for preterm neonates with transitional feeding issues across the various level II (special care) nurseries (SCNs) in Queensland, Australia. Methods: A questionnaire was mailed to all Queensland SCNs in 2005 (n = 36). The questionnaire contained a series of closed-choice and short-answer questions designed to obtain information from each SCN regarding their current practices for managing transitional feeding issues in preterm neonates. Results were confirmed during a follow-up phone call. Results: Responses were obtained from 29 SCNs (80.6%). None of these nurseries reported having any formal, written policies regarding the management of transitional feeding issues in preterm neonates. Wide variations were reported in relation to the suck-feeding assessments and interventions used by staff within the various SCNs. Of the 29 nurseries, 4 (13.8%) reported using checklists or assessments to judge readiness for suck-feeds, and 5 (17.2%) reported using pulse oximetry to judge tolerance of suck-feeding attempts. Eighteen SCNs (62.1%) reported offering some form of active intervention to assist neonates with transitional feeding issues, with the most common intervention techniques reported being non-nutritive sucking during tube feeds, pre-feeding oral stimulation, and actively pacing suck-feeds. Twenty-two SCNs (75.4%) reported having access to a lactation consultant to assist mothers with breastfeeding issues. Conclusions: Differences were reported in the routine management of transitional feeding issues in preterm neonates across the various SCNs in Queensland. It is suggested that evidence based guidelines need to be developed, and that, in order to do this, further research studies are required to determine current best practice, as well as to answer remaining questions. © 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The study of 1777 male and female adolescent students of 11-19 years in the Colombian Caribbean had two objectives: development and validation of two reproductive health intention scales and analyze gender differences. The pilot of the scale consisted of 8 items and was reduced to 6, to check the reliability and validity using factor analysis and principal components with VARIMAX rotation yielded two factors: Intention and Intention Risk Protection, explained between 69.4% and 70% respectively. In the male Protection Intent (M = 3.87 and SD = 1.29) and risk (M = 2.56 and SD = 1.18) obtained an alpha between 0.74 and 0.86, and in Protection of Intent to female (M = 3.49 and SD = 1.35) and risk (M = 1.50 and SD = 0.89) ranged between 0.78 and 086. In conclusion, the reliability and structural stability are adequate and there are gender differences in the scales.
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
Circulating tumor cells (CTCs) are found in the blood of patients with cancer. Although these cells are rare, they can provide useful information for chemotherapy. However, isolation of these rare cells from blood is technically challenging because they are small in numbers. An integrated microfluidic chip, dubbed as CTC chip, was designed and fabricated for conducting tumor cell isolation. As CTCs usually show multidrug resistance (MDR), the effect of MDR inhibitors on chemotherapeutic drug accumulation in the isolated single tumor cell is measured. As a model of CTC isolation, human prostate tumor cells were mixed with mouse blood cells and the labelfree isolation of the tumor cells was conducted based on cell size difference. The major advantages of the CTC chip are the ability for fast cell isolation, followed by multiple rounds of single-cell measurements, suggesting a potential assay for detecting the drug responses based on the liquid biopsy of cancer patients.