446 resultados para Bio-energy
Resumo:
In 2007 the National Framework for Energy Efficiency provided funding for the first survey of energy efficiency education across all Australian universities teaching engineering education. The survey asked the question, ‘What is the state of education for energy efficiency in Australian engineering education?’. There was an excellent response to the survey, with 48 course responses from lecturers across 27 universities from every state and territory in Australia, and 260 student responses from 18 courses across 8 universities from all 6 states. It is concluded from the survey findings that the state of education for energy efficiency in Australian engineering education is currently highly variable and ad hoc across universities and engineering disciplines.
Resumo:
The increasing integration of Renewable Energy Resources (RER) and the role of Electric Energy Storage (EES) in distribution systems has created interest in using energy management strategies. EES has become a suitable resource to manage energy consumption and generation in smart grid. Optimize scheduling of EES can also maximize retailer’s profit by introducing energy time-shift opportunities. This paper proposes a new strategy for scheduling EES in order to reduce the impact of electricity market price and load uncertainty on retailers’ profit. The proposed strategy optimizes the cost of purchasing energy with the objective of minimizing surplus energy cost in hedging contract. A case study is provided to demonstrate the impact of the proposed strategy on retailers’ financial benefit.
Resumo:
The development of Electric Energy Storage (EES) integrated with Renewable Energy Resources (RER) has increased use of optimum scheduling strategy in distribution systems. Optimum scheduling of EES can reduce cost of purchased energy by retailers while improve the reliability of customers in distribution system. This paper proposes an optimum scheduling strategy for EES and the evaluation of its impact on reliability of distribution system. Case study shows the impact of the proposed strategy on reliability indices of a distribution system.
Resumo:
Sustainability has become crucial for the energy industry as projects in this industry are extensively large and complex and have significant impacts on the environment, community and economy. It demands the energy industry to proactively incorporate sustainability ideas and commit to sustainable project development. This study aims to investigate how the Australian energy industry responds to sustainability requirements and in particular what indicators used to measure sustainability performance. To achieve this, content analysis of sustainability reports, vision statements and policy statements of Australian energy companies listed in the 2013 PLATTS Top 250 Global Energy Company Rankings and government reports relating to sustainability has been conducted. The findings show that the energy companies extensively discuss sustainability aspects within three dimensions, i.e. community, environment, and economy. Their primary goals in sustainability are supplying cleaner energy for future, and doing business in a way that improves outcomes for shareholders, employees, business partners and the communities. In particular, energy companies have valued the employees of the business as a one of the key area that needs to be considered. Furthermore, the energy industry has become increasingly aware of the importance of measuring sustainability performance to achieve sustainability goals. A number of sustainability indicators have been developed on the basis of the key themes beyond economic measures. It is envisaged that findings from this research will help stakeholders in the energy industry to adopt different indicators to evaluate and ultimately achieve sustainability performance.
Resumo:
In the 21st Century much of the world will experience untold wealth and prosperity that could not even be conceived only some three centuries before. However as with most, if not all, of the human civilisations, increases in prosperity have accumulated significant environmental impacts that threaten to result in environmentally induced economic decline. A key part of the world’s response to this challenge is to rapidly decarbonise economies around the world, with options to achieve 60-80 per cent improvements (i.e. in the order of Factor 5) in energy and water productivity now available and proven in every sector. Drawing upon the 2009 publication “Factor 5”, in this paper we discuss how to realise such large-scale improvements, involving complexity beyond technical and process innovation. We begin by considering the concept of greenhouse gas stabilisation trajectories that include reducing current greenhouse gas emissions to achieve a ‘peaking’ of global emissions, and subsequent ‘tailing’ of emissions to the desired endpoint in ‘decarbonising’ the economy. Temporal priorities given to peaking and tailing have significant implications for the mix of decarbonising solutions and the need for government and market assistance in causing them to be implemented, requiring careful consideration upfront. Within this context we refer to a number of examples of Factor 5 style opportunities for energy productivity and decarbonisation, and then discuss the need for critical economic contributions to take such success from examples to central mechanisms in decarbonizing the global economy.
Resumo:
This study estimates the environmental efficiency of international listed firms in 10 worldwide sectors from 2007 to 2013 by applying an order-m method, a non-parametric approach based on free disposal hull with subsampling bootstrapping. Using a conventional output of gross profit and two conventional inputs of labor and capital, this study examines the order-m environmental efficiency accounting for the presence of each of 10 undesirable inputs/outputs and measures the shadow prices of each undesirable input and output. The results show that there is greater potential for the reduction of undesirable inputs rather than bad outputs. On average, total energy, electricity, or water usage has the potential to be reduced by 50%. The median shadow prices of undesirable inputs, however, are much higher than the surveyed representative market prices. Approximately 10% of the firms in the sample appear to be potential sellers or production reducers in terms of undesirable inputs/outputs, which implies that the price of each item at the current level has little impact on most of the firms. Moreover, this study shows that the environmental, social, and governance activities of a firm do not considerably affect environmental efficiency.
Resumo:
Legal Context In the wake of the Copenhagen Accord 2009 and the Cancun Agreements 2010, a number of patent offices have introduced fast-track mechanisms to encourage patent applications in relation to clean technologies - such as those pertaining to hydrogen. However, patent offices will be under increasing pressure to ensure that the granted patents satisfy the requisite patent thresholds, as well as to identify and reject cases of fraud, hoaxes, scams, and swindles. Key Points This article examines the BlackLight litigation in the United States, the United Kingdom, and the European Patent Office, and considers how patent offices and courts deal with patent applications in respect of clean energy and perpetual motion machines. Practical Significance The capacity of patent offices to grant sound and reliable patents is critical to the credibility of the patent system, particularly in the context of the current focus upon promoting clean technologies.
Resumo:
Structural fire safety has become one of the key considerations in the design and maintenance of the built infrastructure. Conventionally the fire resistance rating of load bearing Light gauge Steel Frame (LSF) walls is determined based on the standard time-temperature curve given in ISO 834. Recent research has shown that the true fire resistance of building elements exposed to building fires can be less than their fire resistance ratings determined based on standard fire tests. It is questionable whether the standard time-temperature curve truly represents the fuel loads in modern buildings. Therefore an equivalent fire severity approach has been used in the past to obtain fire resistance rating. This is based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of standard fire time-temperature curve. This paper presents the details of research undertaken to develop an energy based time equivalent approach to obtain the fire resistance ratings of LSF walls exposed to realistic design fire curves with respect to standard fire exposure. This approach relates to the amount of energy transferred to the member. The proposed method was used to predict the fire resistance ratings of single and double layer plasterboard lined and externally insulated LSF walls. The predicted fire ratings were compared with the results from finite element analyses and fire design rules for three different wall configurations exposed to both rapid and prolonged fires. The comparison shows that the proposed energy method can be used to obtain the fire resistance ratings of LSF walls in the case of prolonged fires.
Resumo:
Vertical windows are the most common and simplest method to introduce daylight to interior spaces of office buildings, while also providing a view and connection to the outside. However, high contrast ratios between windows and surrounding surfaces can cause visual discomfort for occupants and can negatively influence their health and productivity. Consequently, building occupants may try to adapt their working environment through closing blinds and turning on lights in order to improve indoor visual comfort. Such interventions defeat the purpose of daylight harvesting systems and can increase the forecast electric lighting consumption in buildings that include such systems. A simple strategy to prevent these problematic consequences is to reduce the luminance contrasts presented by the window wall by increasing the luminance of areas surrounding the window through the sparing use of energy-efficient supplementary lighting, such light emitting diodes (LEDs). This paper presents the result of a pilot study in typical office in Brisbane, Australia that tests the effectiveness of a supplementary LED lighting system. The study shows an improvement in the appraisal of the visual environment is achieved using the supplementary system, along with up to 88% reductions in luminance contrast at the window wall. Also observed is a 36% reduction in the likelihood of user interventions that would increase energy usage. These results are used as the basis of an annual energy simulation of the test office and indicate that supplementary systems could be used to save energy beyond what is typically realised in side lit office spaces.
Resumo:
This paper investigates communication protocols for relaying sensor data from animal tracking applications back to base stations. While Delay Tolerant Networks (DTNs) are well suited to such challenging environments, most existing protocols do not consider the available energy that is particularly important when tracking devices can harvest energy. This limits both the network lifetime and delivery probability in energy-constrained applications to the point when routing performance becomes worse than using no routing at all. Our work shows that substantial improvement in data yields can be achieved through simple yet efficient energy-aware strategies. Conceptually, there is need for balancing the energy spent on sensing, data mulling, and delivery of direct packets to destination. We use empirical traces collected in a flying fox (fruit bat) tracking project and show that simple threshold-based energy-aware strategies yield up to 20% higher delivery rates. Furthermore, these results generalize well for a wide range of operating conditions.
Resumo:
Since 2003, Mainland China has been promoting the public–private partnership (PPP) procurement model in the waste-to-energy incineration sector to reduce the waste burying rate and improve environmental quality. Five critical risk factors (CRFs) that affect the construction and operation of waste-to-energy incineration projects have been identified from real-life risk events of 14 PPP waste-to-energy incineration plants through content analysis. These risk factors are insufficient waste supply, disposal of non-licensed waste, environmental risk, payment risk, and lack of supporting infrastructure. A recently completed PPP waste-to-energy incineration plant, the Shanghai Tianma project, was investigated to learn from the effective management of CRFs. First-hand data about the Shanghai Tianma project was collected, with a focus on project negotiation and concession agreement. Lessons learned about risk management were acquired. This paper presents a detailed study of the contractual structure, risk sharing scheme, risk response measures to CRFs, and project transfer of a PPP project. The study results will provide governments with management implications to prepare equitable concession agreements and benefit private investors by effectively mitigating and managing risks in future PPP waste-to-energy incineration projects.
Resumo:
Abstract PURPOSE: Compensatory responses may attenuate the effectiveness of exercise training in weight management. The aim of this study was to compare the effect of moderate- and high-intensity interval training on eating behavior compensation. METHODS: Using a crossover design, 10 overweight and obese men participated in 4-week moderate (MIIT) and high (HIIT) intensity interval training. MIIT consisted of 5-min cycling stages at ± 20% of mechanical work at 45%VO(2)peak, and HIIT consisted of alternate 30-s work at 90%VO(2)peak and 30-s rests, for 30 to 45 min. Assessments included a constant-load exercise test at 45%VO(2)peak for 45 min followed by 60-min recovery. Appetite sensations were measured during the exercise test using a Visual Analog Scale. Food preferences (liking and wanting) were assessed using a computer-based paradigm, and this paradigm uses 20 photographic food stimuli varying along two dimensions, fat (high or low) and taste (sweet or nonsweet). An ad libitum test meal was provided after the constant-load exercise test. RESULTS: Exercise-induced hunger and desire to eat decreased after HIIT, and the difference between MIIT and HIIT in desire to eat approached significance (p = .07). Exercise-induced liking for high-fat nonsweet food tended to increase after MIIT and decreased after HIIT (p = .09). Fat intake decreased by 16% after HIIT, and increased by 38% after MIIT, with the difference between MIIT and HIIT approaching significance (p = .07). CONCLUSIONS: This study provides evidence that energy intake compensation differs between MIIT and HIIT.
Resumo:
The concept of energy gap(s) is useful for understanding the consequence of a small daily, weekly, or monthly positive energy balance and the inconspicuous shift in weight gain ultimately leading to overweight and obesity. Energy gap is a dynamic concept: an initial positive energy gap incurred via an increase in energy intake (or a decrease in physical activity) is not constant, may fade out with time if the initial conditions are maintained, and depends on the 'efficiency' with which the readjustment of the energy imbalance gap occurs with time. The metabolic response to an energy imbalance gap and the magnitude of the energy gap(s) can be estimated by at least two methods, i.e. i) assessment by longitudinal overfeeding studies, imposing (by design) an initial positive energy imbalance gap; ii) retrospective assessment based on epidemiological surveys, whereby the accumulated endogenous energy storage per unit of time is calculated from the change in body weight and body composition. In order to illustrate the difficulty of accurately assessing an energy gap we have used, as an illustrative example, a recent epidemiological study which tracked changes in total energy intake (estimated by gross food availability) and body weight over 3 decades in the US, combined with total energy expenditure prediction from body weight using doubly labelled water data. At the population level, the study attempted to assess the cause of the energy gap purported to be entirely due to increased food intake. Based on an estimate of change in energy intake judged to be more reliable (i.e. in the same study population) and together with calculations of simple energetic indices, our analysis suggests that conclusions about the fundamental causes of obesity development in a population (excess intake vs. low physical activity or both) is clouded by a high level of uncertainty.
Resumo:
The “third-generation” 3D graphene structures, T-junction graphene micro-wells (T-GMWs) are produced on cheap polycrystalline Cu foils in a single-step, low-temperature (270 °C), energy-efficient, and environment-friendly dry plasma-enabled process. T-GMWs comprise vertical graphene (VG) petal-like sheets that seemlessly integrate with each other and the underlying horizontal graphene sheets by forming T-junctions. The microwells have the pico-to-femto-liter storage capacity and precipitate compartmentalized PBS crystals. The T-GMW films are transferred from the Cu substrates, without damage to the both, in de-ionized or tap water, at room temperature, and without commonly used sacrificial materials or hazardous chemicals. The Cu substrates are then re-used to produce similar-quality T-GMWs after a simple plasma conditioning. The isolated T-GMW films are transferred to diverse substrates and devices and show remarkable recovery of their electrical, optical, and hazardous NO2 gas sensing properties upon repeated bending (down to 1 mm radius) and release of flexible trasparent display plastic substrates. The plasma-enabled mechanism of T-GMW isolation in water is proposed and supported by the Cu plasma surface modification analysis. Our GMWs are suitable for various optoelectronic, sesning, energy, and biomedical applications while the growth approach is potentially scalable for future pilot-scale industrial production.
Resumo:
Introduction The epidemic of nutrition related non-communicable diseases such as type 2 diabetes mellitus and obesity has reached to epidemic portion in the Sri Lanka. However, to date, detailed data on food consumption in the Sri Lankan population is limited. The aim of this study is to identify energy and major nutrient intake among Sri Lankan adults. Methods A nationally-representative sample of adults was selected using a multi-stage random cluster sampling technique. Results Data from 463 participants (166 Males, 297 Females) were analyzed. Total energy intake was significantly higher in males (1913 ± 567 kcal/d) than females (1514 ± 458 kcal/d). However, there was no significant gender differences in the percentage of energy from carbohydrate (Male: 72.8 ± 6.4%, Female: 73.9 ± 6.7%), fat (Male: 19.9 ± 6.1%, Female: 18.5 ± 5.7%) and proteins (Male: 10.6 ± 2.1%, Female: 10.9 ± 5.6%). Conclusion The present study provides the first national estimates of energy and nutrient intake of the Sri Lankan adult population.