410 resultados para Test reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many researchers in the field of civil structural health monitoring (SHM) have developed and tested their methods on simple to moderately complex laboratory structures such as beams, plates, frames, and trusses. Fieldwork has also been conducted by many researchers and practitioners on more complex operating bridges. Most laboratory structures do not adequately replicate the complexity of truss bridges. Informed by a brief review of the literature, this paper documents the design and proposed test plan of a structurally complex laboratory bridge model that has been specifically designed for the purpose of SHM research. Preliminary results have been presented in the companion paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose/Objectives: To examine and compare the reliability of four body composition methods commonly used in assessing breast cancer survivors. Design: Cross-sectional. Setting: A rehabilitation facility at a university-based comprehensive cancer center in the southeastern United States. Sample: 14 breast cancer survivors aged 40-71 years. Methods: Body fat (BF) percentage was estimated via bioelectric impedance analysis (BIA), air displacement plethysmography (ADP), and skinfold thickness (SKF) using both three- and seven-site algorithms, where reliability of the methods was evaluated by conducting two tests for each method (test 1 and test 2), one immediately after the other. An analysis of variance was used to compare the results of BF percentage among the four methods. Intraclass correlation coefficient (ICC) was used to test the reliability of each method. Main Research Variable: BF percentage. Findings: Significant differences in BF percentage were observed between BIA and all other methods (three-site SKF, p < 0.001; seven-site SKF, p < 0.001; ADP, p = 0.002). No significant differences (p > 0.05) in BF percentage between three-site SKF, seven-site SKF, and ADP were observed. ICCs between test 1 and test 2 for each method were BIA = 1, ADP = 0.98, three-site SKF = 0.99, and seven-site SKF = 0.94. Conclusions: ADP and both SKF methods produce similar estimates of BF percentage in all participants, whereas BIA overestimated BF percentage relative to the other measures. Caution is recommended when using BIA as the body composition method for breast cancer survivors who have completed treatment but are still undergoing adjuvant hormonal therapy. Implications for Nursing: Measurements of body composition can be implemented very easily as part of usual care and should serve as an objective outcome measure for interventions designed to promote healthy behaviors among breast cancer survivors. - See more at: https://onf.ons.org/onf/38/4/comparison-body-composition-assessment-methods-breast-cancer-survivors#sthash.5djfTS1Q.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Student perceptions of teaching have often been used in tertiary education for evaluation purposes. However, there is a paucity of research on the validity, reliability, and applicability of instruments that cover a wide range of student perceptions of pedagogies and practices in high school settings for descriptive purposes. The study attempts to validate an inventory of pedagogy and practice (IPP) that provides researchers and practitioners with a psychometrically sound instrument that covers the most salient factors related to teaching. Using a sample of students (N = 1515) from 39 schools in Singapore, 14 factors about teaching in English lessons from the students’ perspective were tested with confirmatory factor analysis (classroom task goal, structure and clarity, curiosity and interest, positive class climate, feedback, questioning, quality homework, review of students’ work, conventional teaching, exam preparation, behaviour management, maximizing learning time, student-centred pedagogy, and subject domain teaching). Two external criterion factors were used to further test the IPP factor structure. The inventory will enable teachers to understand more about their teaching and researchers to examine how teaching may be related to learning outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a non-linear excitation controller using inverse filtering is proposed to damp inter-area oscillations. The proposed controller is based on determining generator flux value for the next sampling time which is obtained by maximising reduction rate of kinetic energy of the system after the fault. The desired flux for the next time interval is obtained using wide-area measurements and the equivalent area rotor angles and velocities are predicted using a non-linear Kalman filter. A supplementary control input for the excitation system, using inverse filtering approach, to track the desired flux is implemented. The inverse filtering approach ensures that the non-linearity introduced because of saturation is well compensated. The efficacy of the proposed controller with and without communication time delay is evaluated on different IEEE benchmark systems including Kundur's two area, Western System Coordinating Council three-area and 16-machine, 68-bus test systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Feeding practices are commonly examined as potentially modifiable determinants of children’s eating behaviours and weight status. Although a variety of questionnaires exist to assess different feeding aspects, many lack thorough reliability and validity testing. The Feeding Practices and Structure Questionnaire (FPSQ) is a tool designed to measure early feeding practices related to non-responsive feeding and structure of the meal environment. Face validity, factorial validity, internal reliability and cross-sectional correlations with children’s eating behaviours have been established in mothers with 2-year-old children. The aim of the present study was to further extend the validity of the FPSQ by examining factorial, construct and predictive validity, and stability. Methods Participants were from the NOURISH randomised controlled trial which evaluated an intervention with first-time mothers designed to promote protective feeding practices. Maternal feeding practices (FP) and child eating behaviours were assessed when children were aged 2 years and 3.7 years (n=388). Confirmatory Factor analysis, group differences, predictive relationships, and stability were tested. Results The original 9-factor structure was confirmed when children were aged 3.7±0.3 years. Cronbach’s alpha was above the recommended 0.70 cut-off for all factors except Structured Meal Timing, Over Restriction and Distrust in Appetite which were 0.58, 0.67 and 0.66 respectively. Allocated group differences reflected behaviour consistent with intervention content and all feeding practices were stable across both time points (range of r= 0.45-0.70). There was some evidence for the predictive validity of factors with 2 FP showing expected relationships, 2 FP showing expected and unexpected relationships and 5 FP showing no relationship. Conclusions Reliability and validity was demonstrated for most subscales of the FPSQ. Future validation is warranted with culturally diverse samples and with fathers and other caregivers. The use of additional outcomes to further explore predictive validity is recommended as well as testing construct validity and test-retest reliability of the questionnaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We commend Swanenburg et al. (2013) on translation, development, and clinimetric analysis of the NDI-G. However, the dual-factor structure with factor analysis and the high level of internal consistency (IC) highlighted in their discussion were not emphasized in the abstract or conclusion. These points may imply some inconsistencies with the final conclusions since determination of stable point estimates with the study's small sample are exceedingly difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The diagnosis of frailty is based on physical impairments and clinicians have indicated that early detection is one of the most effective methods for reducing the severity of physical frailty. Maybe, an alternative to the classical diagnosis could be the instrumentalization of classical functional testing, as Romberg test or Timed Get Up and Go Test. The aim of this study was (I) to measure and describe the magnitude of accelerometry values in the Romberg test in two groups of frail and non-frail elderly people through instrumentation with the iPhone 4®, (II) to analyse the performances and differences between the study groups, and (III) to analyse the performances and differences within study groups to characterise accelerometer responses to increasingly difficult challenges to balance. Methods This is a cross-sectional study of 18 subjects over 70 years old, 9 frail subjects and 9 non-frail subjects. The non-parametric Mann–Whitney U test was used for between-group comparisons in means values derived from different tasks. The Wilcoxon Signed-Rank test was used to analyse differences between different variants of the test in both independent study groups. Results The highest difference between groups was found in the accelerometer values with eyes closed and feet parallel: maximum peak acceleration in the lateral axis (p < 0.01), minimum peak acceleration in the lateral axis (p < 0.01) and minimum peak acceleration from the resultant vector (p < 0.01). Subjects with eyes open and feet parallel, greatest differences found between the groups were in the maximum peak acceleration in the lateral axis (p < 0.01), minimum peak acceleration in the lateral axis (p < 0.01) and minimum peak acceleration from the resultant vector (p < 0.001). With eyes closed and feet in tandem, the greatest differences found between the groups were in the minimum peak acceleration in the lateral axis (p < 0.01). Conclusions The accelerometer fitted in the iPhone 4® is able to study and analyse the kinematics of the Romberg test between frail and non-frail elderly people. In addition, the results indicate that the accelerometry values also were significantly different between the frail and non-frail groups, and that values from the accelerometer accelerometer increased as the test was made more complicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a new method for quantifying intersegmental motion of the spine in an instrumented motion segment L4–L5 model using ultrasound image post-processing combined with an electromagnetic device. A prospective test–retest design was employed, combined with an evaluation of stability and within- and between-day intra-tester reliability during forward bending by 15 healthy male patients. The accuracy of the measurement system using the model was calculated to be ± 0.9° (standard deviation = 0.43) over a 40° range and ± 0.4 cm (standard deviation = 0.28) over 1.5 cm. The mean composite range of forward bending was 15.5 ± 2.04° during a single trial (standard error of the mean = 0.54, coefficient of variation = 4.18). Reliability (intra-class correlation coefficient = 2.1) was found to be excellent for both within-day measures (0.995–0.999) and between-day measures (0.996–0.999). Further work is necessary to explore the use of this approach in the evaluation of biomechanics, clinical assessments and interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design Cross-sectional study. Objectives To compare erector spinae (ES) muscle fatigue between chronic non-specific lower back pain (CNLBP) sufferers and healthy subjects from a biomechanical perspective during fatiguing isometric lumbar extensions. Background Paraspinal muscle maximal contraction and fatigue are used as a functional predictor for disabilities. The simplest method to determine muscle fatigue is by evaluating the evolution during specific contractions, such as isometric contractions. There are no studies that evaluate the evolution of the ES muscle during fatiguing isometric lumbar extensions and analyse functional and architectural variables. Methods In a pre-calibrated system, participants performed a maximal isometric extension of the lumbar spine for 5 and 30 seconds. Functional variables (torque and muscle activation) and architecture (pennation angle and muscle thickness) were measured using a load cell, surface electromyography and ultrasound, respectively. The results were normalised and a reliability study of the ultrasound measurement was made. Results: The ultrasound measurements were highly reliable, with Cronbach’s alpha values ranging from 0.951 0.981. All measured variables shown significant differences before and after fatiguing isometric lumbar extension. Conclusion During a lumbar isometric extension test, architecture and functional variables of the ES muscle could be analised using ultrasound, surface EMG and load cell. In adition, during an endurance test, ES muscle suffers an acute effect on architectural and functional variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analysed whether a significant relationship exists between the torque and muscle thickness and pennation angle of the erector spinae muscle during a maximal isometric lumbar extension with the lumbar spine in neutral position. This was a cross-sectional study in which 46 healthy adults performed three repetitions for 5 s of maximal isometric lumbar extension with rests of 90 s. During the lumbar extensions, bilateral ultrasound images of the erector spinae muscle (to measure pennation angle and muscle thickness) and torque were acquired. Reliability test analysis calculating the internal consistency (Cronbach's alpha) of the measure, correlation between pennation angle, muscle thickness and torque extensions were examined. Through a linear regression the contribution of each independent variable (muscle thickness and pennation angle) to the variation of the dependent variable (torque) was calculated. The results of the reliability test were: 0.976–0.979 (pennation angle), 0.980–0.980 (muscle thickness) and 0.994 (torque). The results show that pennation angle and muscle thickness were significantly related to each other with a range between 0.295 and 0.762. In addition, multiple regression analysis showed that the two variables considered in this study explained 68% of the variance in the torque. Pennation angle and muscle thickness have a moderate impact on the variance exerted on the torque during a maximal isometric lumbar extension with the lumbar spine in neutral position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although key to understanding individual variation in task-related brain activation, the genetic contribution to these individual differences remains largely unknown. Here we report voxel-by-voxel genetic model fitting in a large sample of 319 healthy, young adult, human identical and fraternal twins (mean ± SD age, 23.6 ±1.8 years) who performed an n-back working memory task during functional magnetic resonance imaging (fMRI) at a high magnetic field (4 tesla). Patterns of task-related brain response (BOLD signal difference of 2-back minus 0-back) were significantly heritable, with the highest estimates (40 - 65%) in the inferior, middle, and superior frontal gyri, left supplementary motor area, precentral and postcentral gyri, middle cingulate cortex, superior medial gyrus, angular gyrus, superior parietal lobule, including precuneus, and superior occipital gyri. Furthermore, high test-retest reliability for a subsample of 40 twins indicates that nongenetic variance in the fMRI brain response is largely due to unique environmental influences rather than measurement error. Individual variations in activation of the working memory network are therefore significantly influenced by genetic factors. By establishing the heritability of cognitive brain function in a large sample that affords good statistical power, and using voxel-by-voxel analyses, this study provides the necessary evidence for task-related brain activation to be considered as an endophenotype for psychiatric or neurological disorders, and represents a substantial new contribution to the field of neuroimaging genetics. These genetic brain maps should facilitate discovery of gene variants influencing cognitive brain function through genome-wide association studies, potentially opening up new avenues in the treatment of brain disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review studies of Nelson's (1976) Modified Card Sorting Test (MCST) that have examined the performance of subjects with frontal lobe dysfunction. Six studies investigated the performance of normal controls and patients with frontal lobe dysfunction, whereas four studies compared the performance of frontal and nonfrontal patients. One further study compared the performance of amnesic patients both on the MCST and on the original Wisconsin Card Sorting Test (WCST). Evidence regarding the MCST's differential sensitivity to frontal lobe dysfunction is weak, as is the evidence regarding the equivalence of the MCST and WCST. It is likely that the MCST is an altogether different test from the standard version. In the absence of proper normative data for the MCST, we provide a table of scores derived from the control groups of various studies. Given the paucity of evidence, further research is required before the MCST can be recommended for use as a marker of frontal lobe dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To investigate the test-retest stability of a standardized version of Nelson's (1976) Modified Card Sorting Test (MCST) and its relationships with demographic variables in a sample of healthy older adults. Design. A standard card order and administration were devised for the MCST and administered to participants at an initial assessment, and again at a second session conducted a minimum of six months later in order to examine its test-retest stability. Participants were also administered the WAIS-R at initial assessment in order to provide a measure of psychometric intelligence. Methods. Thirty-six (24 female, 12 male) healthy older adults aged 52 to 77 years with mean education 12.42 years (SD = 3.53) completed the MCST on two occasions approximately 7.5 months (SD = 1.61) apart. Stability coefficients and test-retest differences were calculated for the range of scores. The effect of gender on MCST performance was examined. Correlations between MCST scores and age, education and WAIS-R IQs were also determined. Results. Stability coefficients ranged from .26 for the percent perseverative errors measure to .49 for the failure to maintain set measure. Several measures were significantly correlated with age, education and WAIS-R IQs, although no effect of gender on MCST performance was found. Conclusions. None of the stability coefficients reached the level required for clinical decision making. The results indicate that participants' age, education, and intelligence need to be considered when interpreting MCST performance. Normative studies of MCST performance as well as further studies with patients with executive dysfunction are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hemodynamic response function (HRF) describes the local response of brain vasculature to functional activation. Accurate HRF modeling enables the investigation of cerebral blood flow regulation and improves our ability to interpret fMRI results. Block designs have been used extensively as fMRI paradigms because detection power is maximized; however, block designs are not optimal for HRF parameter estimation. Here we assessed the utility of block design fMRI data for HRF modeling. The trueness (relative deviation), precision (relative uncertainty), and identifiability (goodness-of-fit) of different HRF models were examined and test-retest reproducibility of HRF parameter estimates was assessed using computer simulations and fMRI data from 82 healthy young adult twins acquired on two occasions 3 to 4 months apart. The effects of systematically varying attributes of the block design paradigm were also examined. In our comparison of five HRF models, the model comprising the sum of two gamma functions with six free parameters had greatest parameter accuracy and identifiability. Hemodynamic response function height and time to peak were highly reproducible between studies and width was moderately reproducible but the reproducibility of onset time was low. This study established the feasibility and test-retest reliability of estimating HRF parameters using data from block design fMRI studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Concordance is characterised as a negotiation-like health communication approach based on an equal and collaborative partnership between patients and health professionals. The Leeds Attitudes to Concordance II (LATCon II) scale was developed to measure the attitudes towards concordance. The purpose of this study was to translate the LATCon II into Chinese and psychometrically test the Chinese version of LATCon II (C-LATCon II). Methods The study involved three phases: i) translation and cross-cultural adaptation; ii) pilot study, and; iii) a cross-sectional survey (n = 366). Systematic random sampling was used to recruit hypertensive patients from nine communities covering around 78,000 residents in China. Tests of psychometric properties included content validity, construct validity, criteria-related validity (correlation between the C-LATCon II and the Therapeutic Adherence Scale for Hypertensive Patients (TASHP)), internal reliability, and test-retest reliability (n = 30). Results The study found that the C-LATCon II had a satisfactory content validity (item-level Content Validity Index (CVI) = 0.83-1, scale-level CVI/universal agreement = 0.89, and scale-level CVI/averaging calculation = 0.98), construct validity (four components extracted explained 56.66% of the total variance), internal reliability (Cronbach’s alpha of overall scale and four components was 0.78 and 0.66-0.84, respectively), and test-retest reliability (Pearson’s correlation coefficient = 0.82, p < 0.001; interclass correlation coefficient = 0.82, p < 0.001; linear weighted kappa3 statistic for each item = 0.40-0.65, p < 0.05). Criteria-related validity showed a weak association (Pearson’s correlation coefficient = 0.11, p < 0.05) between patients’ attitudes towards concordance during health communication and their health behaviours for hypertension management. Conclusions The C-LATCon II is a validated and reliable instrument which can be used to evaluate the attitudes to concordance in Chinese populations. Four components (health professionals’ attitudes, partnership between two parties, therapeutic decision making, and patients’ involvement) describe the attitudes towards concordance during health communication.