552 resultados para State –Building


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unsteady natural convection inside a triangular cavity subject to a non-instantaneous heating on the inclined walls in the form of an imposed temperature which increases linearly up to a prescribed steady value over a prescribed time is reported. The development of the flow from start-up to a steady-state has been described based on scaling analyses and direct numerical simulations. The ramp temperature has been chosen in such a way that the boundary layer is reached a quasi-steady mode before the growth of the temperature is completed. In this mode the thermal boundary layer at first grows in thickness, then contracts with increasing time. However, if the imposed wall temperature growth period is sufficiently short, the boundary layer develops differently. It is seen that the shape of many houses are isosceles triangular cross-section. The heat transfer process through the roof of the attic-shaped space should be well understood. Because, in the building energy, one of the most important objectives for design and construction of houses is to provide thermal comfort for occupants. Moreover, in the present energy-conscious society it is also a requirement for houses to be energy efficient, i.e. the energy consumption for heating or air-conditioning houses must be minimized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raman spectroscopy has been used to study vanadates in the solid state. The molecular structure of the vanadate minerals vésigniéite [BaCu3(VO4)2(OH)2] and volborthite [Cu3V2O7(OH)2·2H2O] have been studied by Raman spectroscopy and infrared spectroscopy. The spectra are related to the structure of the two minerals. The Raman spectrum of vésigniéite is characterized by two intense bands at 821 and 856 cm−1 assigned to ν1 (VO4)3− symmetric stretching modes. A series of infrared bands at 755, 787 and 899 cm−1 are assigned to the ν3 (VO4)3− antisymmetric stretching vibrational mode. Raman bands at 307 and 332 cm−1 and at 466 and 511 cm−1 are assigned to the ν2 and ν4 (VO4)3− bending modes. The Raman spectrum of volborthite is characterized by the strong band at 888 cm−1, assigned to the ν1 (VO3) symmetric stretching vibrations. Raman bands at 858 and 749 cm−1 are assigned to the ν3 (VO3) antisymmetric stretching vibrations; those at 814 cm−1 to the ν3 (VOV) antisymmetric vibrations; that at 508 cm−1 to the ν1 (VOV) symmetric stretching vibration and those at 442 and 476 cm−1 and 347 and 308 cm−1 to the ν4 (VO3) and ν2 (VO3) bending vibrations, respectively. The spectra of vésigniéite and volborthite are similar, especially in the region of skeletal vibrations, even though their crystal structures differ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Late last year teaching staff at Griffith University participated in a symposium entitled 'Spotlight on Generic Skills & Flexible Learning'. This event brought together academic staff as well as library staff, learning advisers and other support staff interested in teaching and learning issues. The discussion was based on the premise that the University has a responsibility to ensure that its courses emphasise broad educational values and 'produce highly sought after graduates with globally applicable skills for the international market'(1). It was acknowledged that the University consistently scores very highly with graduates for its development of generic skills. However at the same time staff expressed concern at the challenge of developing more flexible, student-centred learning environments that have generic skills embedded across all programs (2). As a result there has been much debate in the University about which skills are important, how they will be acquired and how they could effectively be built into the curriculum. One outcome of these discussions is the project described in this paper. What follows is an overview of the project and a discussion about the integration and development of information literacy as a generic attribute in the curriculum and some suggestions on ways forward.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the method and results of a survey of 27 of the 33 Australian universities teaching engineering education in late 2007, undertaken by The Natural Edge Project (hosted by Griffith University and the Australian National University) and supported by the National Framework for Energy Efficiency. This survey aimed to ascertain the extent of energy efficiency (EE) education, and to identify preferred methods to assist in increasing the extent to which EE education is embedded in engineering curriculum. In this paper the context for the survey is supported by a summary of the key results from a variety of surveys undertaken over the last decade internationally. The paper concludes that EE education across universities and engineering disciplines in Australia is currently highly variable and ad hoc. Based on the results of the survey, this paper highlights a number of preferred options to support educators to embed sustainability within engineering programs, and future opportunities for monitoring EE, within the context of engineering education for sustainable development (EESD).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To highlight the registration issues for nurses who wish to practice nationally, particularly those practicing within the telehealth sector. Design: As part of a national clinical research study, applications were made to every state and territory for mutual recognition of nursing registration and fee waiver for telenursing cross boarder practice for a period of three years. These processes are described using a case study approach. Outcome: The aim of this case study was to achieve registration in every state and territory of Australia without paying multiple fees by using mutual recognition provisions and the cross-border fee waiver policy of the nurse regulatory authorities in order to practice telenursing. Results: Mutual recognition and fee waiver for cross-border practice was granted unconditionally in two states: Victoria (Vic) and Tasmania (Tas), and one territory: the Northern Territory (NT). The remainder of the Australian states and territories would only grant temporary registration for the period of the project or not at all, due to policy restrictions or nurse regulatory authority (NRA) Board decisions. As a consequence of gaining fee waiver the annual cost of registration was a maximum of $145 per annum as opposed to the potential $959 for initial registration and $625 for annual renewal. Conclusions: Having eight individual nurses Acts and NRAs for a population of 265,000 nurses would clearly indicate a case for over regulation in this country. The structure of regulation of nursing in Australia is a barrier to the changing and evolving role of nurses in the 21st century and a significant factor when considering workforce planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As global warming entails new conditions for the built environment, the thermal and energy performance of existing buildings, which are designed based on current weather data, may become unclear and remain a great concern. Through building computer simulation and qualitative analysis of the weighted factor for the outdoor temperature impact on building energy and thermal performance, this paper investigates the sensitivity of different office building zoning to the potential global warming. A standard office building type is examined for all eight capital cities in Australia. Results show that comparing the middle and top floors, except for cool climate (i.e. Hobart), the ground floor appears to be the most sensitive to the effect of global warming and has the highest tendency for a overheating problem. From the analysis of the responses of different zone orientations to the outdoor air temperature increase, it is also found that there are widely varied responses between zone orientations, with South zone (in the southern hemisphere) being the most sensitive. With an increased external air temperature, the variation between different floors or zone orientations will become more significant, up to 53 percent increase of overheating hours in Darwin and 47 percent increase of cooling load in Hobart.