471 resultados para Clinical psychologists - Supervision of


Relevância:

100.00% 100.00%

Publicador:

Resumo:

CoMFA and CoMSIA analysis were utilized in this investigation to define the important interacting regions in paclitaxel/tubulin binding site and to develop selective paclitaxel-like active compounds. The starting geometry of paclitaxel analogs was taken from the crystal structure of docetaxel. A total of 28 derivatives of paclitaxel were divided into two groups—a training set comprising of 19 compounds and a test set comprising of nine compounds. They were constructed and geometrically optimized using SYBYL v6.6. CoMFA studies provided a good predictability (q2 = 0.699, r2 = 0.991, PC = 6, S.E.E. = 0.343 and F = 185.910). They showed the steric and electrostatic properties as the major interacting forces whilst the lipophilic property contribution was a minor factor for recognition forces of the binding site. These results were in agreement with the experimental data of the binding activities of these compounds. Five fields in CoMSIA analysis (steric, electrostatic, hydrophobic, hydrogen-bond acceptor and donor properties) were considered contributors in the ligand–receptor interactions. The results obtained from the CoMSIA studies were: q2 = 0.535, r2 = 0.983, PC = 5, S.E.E. = 0.452 and F = 127.884. The data obtained from both CoMFA and CoMSIA studies were interpreted with respect to the paclitaxel/tubulin binding site. This intuitively suggested where the most significant anchoring points for binding affinity are located. This information could be used for the development of new compounds having paclitaxel-like activity with new chemical entities to overcome the existing pharmaceutical barriers and the economical problem associated with the synthesis of the paclitaxel analogs. These will boost the wide use of this useful class of compounds, i.e. in brain tumors as the most of the present active compounds have poor blood–brain barrier crossing ratios and also, various tubulin isotypes has shown resistance to taxanes and other antimitotic agents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inappropriate food or medication texture in patients with dysphagia is the most significant risk factor for pneumonia. Dysphagia is prevalent within care homes for the older person as it is largely found in conditions associated with ageing. This study was designed to determine the appropriateness of medication formulation choices in elderly patients with dysphagia in care homes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As conditions such as stroke, cancer, Parkinson's disease and Huntingdon's chorea are commonly found in care homes between 15% and 30% of residents in care homes have been found to have difficulties in swallowing their medicines.To address the difficulties associated with administering medicines to patients who cannot swallow (with dysphagia), Individualised Medication Administration Guides (I-MAGs) were introduced by a specialised pharmacist in Care for Elderly wards in a general hospital in East Anglia. The guides contained detailed information about how to administer each medication and they were individualised to the needs of the patient. The I-MAGs were printed in green forms and attached to the medication chart in order to be used in conjunction with it. The ward nurses reported an increase in their confidence when administering medication when I-MAGs were present in the ward. Some patients with I-MAG were discharged to care homes where the I-MAG might have been equally useful. However, the design of such guides is not known to be suitable for care homes environment where they have never been used before. This study aims to explore the opinions of nurses and carers within care homes on the relevance and acceptability of individualised medication administration guides for patients with dysphagia (PWD).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dysphagia is a common and problematic symptom characterised by varying degrees of difficulty swallowing food, fluids and medicines of differing consistencies. International primary care based studies have identified that between 1 in 4 and 1 in 5 patients have some form of dysphagia, it can affect medicines taking behaviour and healthcare professionals are largely unaware of this1,2. Similar research has not been undertaken in the UK. Adherence related pharmacy based services in the UK provide an opportunity for community pharmacists to identify the problem and facilitate better medicines use. The aim of this pilot study was to estimate the level of patient reported dysphagia in older persons using community pharmacies in the UK, describe how it affects their medicine taking behaviour and identify whether advanced pharmacy services are related to improved awareness of this.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Balance dysfunction is one of the most common problems in people who suffer stroke. To parameterize functional tests standardized by inertial sensors have been promoted in applied medicine. The aim of this study was to compare the kinematic variables of the Functional Reach Test (FRT) obtained by two inertial sensors placed on the trunk and lumbar region between stroke survivors (SS) and healthy older adults (HOA) and to analyze the reliability of the kinematic measurements obtained. Methods Cross-sectional study. Five SS and five HOA over 65. A descriptive analysis of the average range as well as all kinematic variables recorded was developed. The intrasubject and intersubject reliability of the measured variables was directly calculated. Results In the same intervals, the angular displacement was greater in the HOA group; however, they were completed at similar times for both groups, and HOA conducted the test at a higher speed and greater acceleration in each of the intervals. The SS values were higher than HOA values in the maximum and minimum acceleration in the trunk and in the lumbar region. Conclusions The SS show less functional reach, a narrower, slower and less accelerated movement during the FRT execution, but with higher peaks of acceleration and speed when they are compared with HOA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study assessed environmental health risk from dioxin in foods and sustainability of risk reduction programs at two heavily contaminated former military sites in Vietnam. The study involved 1000 household surveys, analysis of food samples and in-depth discussions with residents and officials. The findings indicate that more than 40 years after the war, local residents still experience high exposure to dioxin if they consume local high risk foods. Public health intervention programs were rated moderately to well sustained. Internal migration, and lack of clear, official guidance and sensitivity regarding dioxin issues were the main challenges for sustainability of prevention programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background In the emergency department, portable point-of-care testing (POCT) coagulation devices may facilitate stroke patient care by providing rapid International Normalized Ratio (INR) measurement. The objective of this study was to evaluate the reliability, validity, and impact on clinical decision-making of a POCT device for INR testing in the setting of acute ischemic stroke (AIS). Methods A total of 150 patients (50 healthy volunteers, 51 anticoagulated patients, 49 AIS patients) were assessed in a tertiary care facility. The INR's were measured using the Roche Coaguchek S and the standard laboratory technique. Results The interclass correlation coefficient and 95% confidence interval between overall POCT device and standard laboratory value INRs was high (0.932 (0.69 - 0.78). In the AIS group alone, the correlation coefficient and 95% CI was also high 0.937 (0.59 - 0.74) and diagnostic accuracy of the POCT device was 94%. Conclusions When used by a trained health professional in the emergency department to assess INR in acute ischemic stroke patients, the CoaguChek S is reliable and provides rapid results. However, as concordance with laboratory INR values decreases with higher INR values, it is recommended that with CoaguChek S INRs in the > 1.5 range, a standard laboratory measurement be used to confirm the results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study design Retrospective validation study. Objectives To propose a method to evaluate, from a clinical standpoint, the ability of a finite-element model (FEM) of the trunk to simulate orthotic correction of spinal deformity and to apply it to validate a previously described FEM. Summary of background data Several FEMs of the scoliotic spine have been described in the literature. These models can prove useful in understanding the mechanisms of scoliosis progression and in optimizing its treatment, but their validation has often been lacking or incomplete. Methods Three-dimensional (3D) geometries of 10 patients before and during conservative treatment were reconstructed from biplanar radiographs. The effect of bracing was simulated by modeling displacements induced by the brace pads. Simulated clinical indices (Cobb angle, T1–T12 and T4–T12 kyphosis, L1–L5 lordosis, apical vertebral rotation, torsion, rib hump) and vertebral orientations and positions were compared to those measured in the patients' 3D geometries. Results Errors in clinical indices were of the same order of magnitude as the uncertainties due to 3D reconstruction; for instance, Cobb angle was simulated with a root mean square error of 5.7°, and rib hump error was 5.6°. Vertebral orientation was simulated with a root mean square error of 4.8° and vertebral position with an error of 2.5 mm. Conclusions The methodology proposed here allowed in-depth evaluation of subject-specific simulations, confirming that FEMs of the trunk have the potential to accurately simulate brace action. These promising results provide a basis for ongoing 3D model development, toward the design of more efficient orthoses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To establish whether there was a difference in health-related quality of life (HRQoL) in people with chronic musculoskeletal disorders (PwCMSKD) after participating in a multimodal physiotherapy program (MPP) either two or three sessions a week. Methods: Total of 114 PwCMSKD participated in this prospective randomised controlled trial. An individualised MPP, consisting of exercises for mobility, motor-control, muscle strengthening, cardiovascular training, and health education, was implemented either twice a week (G2: n = 58) or three times a week) (G3: n = 56) for 1 year. Outcomes: HRQoL physical and mental health state (PHS/MHS), Roland Morris disability Questionnaire (RMQ), Neck-Disability-Index (NDI) and Western Ontario and McMaster Universities’ Arthritis Index (WOMAC) were used to measure outcomes of MPP for people with chronic low back pain, chronic neck pain and osteoarthritis, respectively. Measures were taken at baseline, 8 weeks (8 w), 6 months (6 m), and 1 year (1 y) after starting the programme. Results: No statistically significant differences were found between the two groups (G2 and G3), except in NDI at 8 w (−3.34, (CI 95%: −6.94/0.84, p = 0.025 (scale 0–50)). All variables showed improvement reaching the following values (from baseline to 1 y) G2: PHS: 57.72 (baseline: 41.17; (improvement: 16.55%), MHS: 74.51 (baseline: 47.46, 27.05%), HRQoL 0.90 (baseline: 0.72, 18%)), HRQoL-VAS 84.29 (baseline: 58.04, 26.25%), RMQ 4.15 (baseline: 7.85, 15.42%), NDI 3.96 (baseline: 21.87, 35.82%), WOMAC 7.17 (baseline: 25.51, 19.10%). G3: PHS: 58.64 (baseline: 39.75, 18.89%), MHS: 75.50 (baseline: 45.45, (30.05%), HRQoL 0.67 (baseline: 0.88, 21%), HRQoL-VAS 86.91 (baseline: 52.64, 34.27%), RMQ 4.83 (baseline: 8.93, 17.08%), NDI 4.91 (baseline: 23.82, 37.82%), WOMAC 6.35 (baseline: 15.30, 9.32%). Conclusions: No significant differences between the two groups were found in the outcomes of a MPP except in the NDI at 8 weeks, but both groups improved in all variables during the course of 1 year under study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The objectives of this cross-sectional, analytical inference analysis were to compare shoulder muscle activation at arm elevations of 0° to 90° through different movement planes and speeds during in-water and dry-land exercise and to extrapolate this information to a clinical rehabilitation model. Methods Six muscles of right-handed adult subjects (n = 16; males/females: 50%; age: 26.1 ± 4.5 years) were examined with surface electromyography during arm elevation in water and on dry land. Participants randomly performed 3 elevation movements (flexion, abduction, and scaption) through 0° to 90°. Three movement speeds were used for each movement as determined by a metronome (30°/sec, 45°/sec, and 90°/sec). Dry-land maximal voluntary contraction tests were used to determine movement normalization. Results Muscle activity levels were significantly lower in water compared with dry land at 30°/sec and 45°/sec but significantly higher at 90°/sec. This sequential progressive activation with increased movement speed was proportionally higher on transition from gravity-based on-land activity to water-based isokinetic resistance. The pectoralis major and latissimus dorsi muscles showed higher activity during abduction and scaption. Conclusions These findings on muscle activation suggest protocols in which active flexion is introduced first at low speeds (30°/sec) in water, then at medium speeds (45°/sec) in water or on dry land, and finally at high speeds (90°/sec) on dry land before in water. Abduction requires higher stabilization, necessitating its introduction after flexion, with scaption introduced last. This model of progressive sequential movement ensures that early active motion and then stabilization are appropriately introduced. This should reduce rehabilitation time and improve therapeutic goals without compromising patient safety or introducing inappropriate muscle recruitment or movement speed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To test the effectiveness of static and dynamic orthoses using them as an exclusive treatment for proximal interphalangeal (PIP) joint flexion contracture compared with other hand therapy conservative treatments described in the literature. Methods 60 patients who used orthoses were compared with a control group that received other hand therapy treatments. Clinical assessments were measured before the experiment and 3 months after and included active PIP joint extension and function. Results A significant improvement in the extension active range of motion at the PIP joint in the second measurement was found in both groups, but it was significantly greater in the experimental group. Improvement in function (Disabilities of the Arm, Shoulder, and Hand score) between the first and second assessment was similar in the control and experimental groups. Conclusions Using night progressive static and daily dynamic orthoses as an exclusive treatment during the proliferative phase led to significant improvements in the PIP joint active extension, but the improvement did not correlate with increased function as perceived by the patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The Neck Disability Index frequently is used to measure outcomes of the neck. The statistical rigor of the Neck Disability Index has been assessed with conflicting outcomes. To date, Confirmatory Factor Analysis of the Neck Disability Index has not been reported for a suitably large population study. Because the Neck Disability Index is not a condition-specific measure of neck function, initial Confirmatory Factor Analysis should consider problematic neck patients as a homogenous group. PURPOSE: We sought to analyze the factor structure of the Neck Disability Index through Confirmatory Factor Analysis in a symptomatic, homogeneous, neck population, with respect to pooled populations and gender subgroups. STUDY DESIGN: This was a secondary analysis of pooled data. PATIENT SAMPLE: A total of 1,278 symptomatic neck patients (67.5% female, median age 41 years), 803 nonspecific and 475 with whiplash-associated disorder. OUTCOME MEASURES: The Neck Disability Index was used to measure outcomes. METHODS: We analyzed pooled baseline data from six independent studies of patients with neck problems who completed Neck Disability Index questionnaires at baseline. The Confirmatory Factor Analysis was considered in three scenarios: the full sample and separate sexes. Models were compared empirically for best fit. RESULTS: Two-factor models have good psychometric properties across both the pooled and sex subgroups. However, according to these analyses, the one-factor solution is preferable from both a statistical perspective and parsimony. The two-factor model was close to significant for the male subgroup (p<.07) where questions separated into constructs of mental function (pain, reading headaches and concentration) and physical function (personal care, lifting, work, driving, sleep, and recreation). CONCLUSIONS: The Neck Disability Index demonstrated a one-factor structure when analyzed by Confirmatory Factor Analysis in a pooled, homogenous sample of neck problem patients. However, a two-factor model did approach significance for male subjects where questions separated into constructs of mental and physical function. Further investigations in different conditions, subgroup and sex-specific populations are warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The purpose of this study was to adapt and validate the Foot Function Index to the Spanish (FFI-Sp) following the guidelines of the American Academy of Orthopaedic Surgeons. Methods A cross-sectional study 80 participants with some foot pathology. A statistical analysis was made, including a correlation study with other questionnaires (the Foot Health Status Questionnaire, EuroQol 5-D, Visual Analogue Pain Scale, and the Short Form SF-12 Health Survey). Data analysis included reliability, construct and criterion-related validity and factor analyses. Results The principal components analysis with varimax rotation produced 3 principal factors that explained 80% of the variance. The confirmatory factor analysis showed an acceptable fit with a comparative fit index of 0.78. The FFI-Sp demonstrated excellent internal consistency on the three subscales: pain 0.95; disability 0.96; and activity limitation 0.69, the subscale that scored lowest. The correlation between the FFI-Sp and the other questionnaires was high to moderate. Conclusions The Spanish version of the Foot Function Index (FFI-Sp) is a tool that is a valid and reliable tool with a very good internal consistency for use in the assessment of pain, disability and limitation of the function of the foot, for use both in clinic and research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We commend Swanenburg et al. (2013) on translation, development, and clinimetric analysis of the NDI-G. However, the dual-factor structure with factor analysis and the high level of internal consistency (IC) highlighted in their discussion were not emphasized in the abstract or conclusion. These points may imply some inconsistencies with the final conclusions since determination of stable point estimates with the study's small sample are exceedingly difficult.