374 resultados para Objective measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyse and compare standing thoracolumbar curves in normal weight participants and participants with obesity, using an electromagnetic device, and to analyse the measurement reliability. Material and Methods. Cross-sectional study was carried out. 36 individuals were divided into two groups (normal-weight and participants with obesity) according to their waist circumference. The reference points (T1–T8–L1–L5 and both posterior superior iliac spines) were used to perform a description of thoracolumbar curvature in the sagittal and coronal planes. A transformation from the global coordinate system was performed and thoracolumbar curves were adjusted by fifth-order polynomial equations. The tangents of the first and fifth lumbar vertebrae and the first thoracic vertebra were determined from their derivatives. The reliability of the measurement was assessed according to the internal consistency of the measure and the thoracolumbar curvature angles were compared between groups. Results. Cronbach’s alpha values ranged between 0.824 (95% CI: 0.776–0.847) and 0.918 (95% CI: 0.903–0.949). In the coronal plane, no significant differences were found between groups; however, in sagittal plane, significant differences were observed for thoracic kyphosis. Conclusion. There were significant differences in thoracic kyphosis in the sagittal plane between two groups of young adults grouped according to their waist circumference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To analyze the ability to discriminate between healthy individuals and individuals with chronic nonspecific low back pain (CNLBP) by measuring the relation between patient-reported outcomes and objective clinical outcome measures of the erector spinae (ES) muscles using an ultrasound during maximal isometric lumbar extension. Design Cross-sectional study with screening and diagnostic tests with no blinded comparison. Setting University laboratory. Participants Healthy individuals (n=33) and individuals with CNLBP (n=33). Interventions Each subject performed an isometric lumbar extension. With the variables measured, a discriminate analysis was performed using a value ≥6 in the Roland and Morris disability questionnaire (RMDQ) as the grouping variable. Then, a logistic regression with the functional and architectural variables was performed. A new index was obtained from each subject value input in the discriminate multivariate analysis. Main Outcome Measures Morphologic muscle variables of the ES muscle were measured through ultrasound images. The reliability of the measures was calculated through intraclass correlation coefficients (ICCs). The relation between patient-reported outcomes and objective clinical outcome measures was analyzed using a discriminate function from standardized values of the variables and an analysis of the reliability of the ultrasound measurement. Results The reliability tests show an ICC value >.95 for morphologic and functional variables. The independent variables included in the analysis explained 42% (P=.003) of the dependent variable variance. Conclusions The relation between objective variables (electromyography, thickness, pennation angle) and a subjective variable (RMDQ ≥6) and the capacity of this relation to identify CNLBP within a group of healthy subjects is moderate. These results should be considered by clinicians when treating this type of patient in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a paucity of research published in relation to the temporal aspect of destination image change over time. Given increasing investments in destination branding, research is needed to enhance understanding of how to monitor destination brand performance, of which destination image is the core construct, over time. This article reports the results of four studies tracking brand performance of a competitive set of five destinations, between 2003 and 2012. Results indicate minimal changes in perceptions held of the five destinations of interest over the 10 years, supporting the assertion of Gartner (1986) and Gartner and Hunt (1987) that destination image change will only occur slowly over time. While undertaken in Australia, the research approach provides DMOs in other parts of the world with a practical tool for evaluating brand performance over time; in terms of measures of effectiveness of past marketing communications, and indicators of future performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present global and regional rates of brain atrophy measured on serially acquired Tl-weighted brain MR images for a group of Alzheimer's disease (AD) patients and age-matched normal control (NC) subjects using the analysis procedure described in Part I. Three rates of brain atrophy: the rate of atrophy in the cerebrum, the rate of lateral ventricular enlargement and the rate of atrophy in the region of temporal lobes, were evaluated for 14 AD patients and 14 age-matched NC subjects. All three rates showed significant differences between the two groups. However, the greatest separation of the two groups was obtained when the regional rates were combined. This application has demonstrated that rates of brain atrophy, especially in specific regions of the brain, based on MR images can provide sensitive measures for evaluating the progression of AD. These measures will be useful for the evaluation of therapeutic effects of novel therapies for AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we use an experimental design to compare the performance of elicitation rules for subjective beliefs. Contrary to previous works in which elicited beliefs are compared to an objective benchmark, we consider a purely subjective belief framework (confidence in one’s own performance in a cognitive task and a perceptual task). The performance of different elicitation rules is assessed according to the accuracy of stated beliefs in predicting success. We measure this accuracy using two main factors: calibration and discrimination. For each of them, we propose two statistical indexes and we compare the rules’ performances for each measurement. The matching probability method provides more accurate beliefs in terms of discrimination, while the quadratic scoring rule reduces overconfidence and the free rule, a simple rule with no incentives, which succeeds in eliciting accurate beliefs. Nevertheless, the matching probability appears to be the best mechanism for eliciting beliefs due to its performances in terms of calibration and discrimination, but also its ability to elicit consistent beliefs across measures and across tasks, as well as its empirical and theoretical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring marketing effectiveness is a major challenge for marketing academics and practitioners. An investigation that uses dependence analysis to examine the link between objective marketing instruments and subjective customer perceptions of them is missing from existing approaches. In examining this link, the present article redresses this deficit. A conceptual model is developed in order to structure and explain the effects of instruments on perceptions for 3 marketing instrument categories (value, relationship, and brand). The links are analyzed in an empirical study with bank customers. Instruments are measured by using objective internal data. Perceptions are measured based on a customer survey. The relationships between instruments and perceptions are examined using regression analysis. Most of the effects of instruments on perceptions are significant, signaling that the activities conducted are perceived as intended. In particular, some interesting results become evident, such as the negative effect on relationship perceptions of follow-up calls subsequent to direct mail services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: Our objective is to determine if there is sufficient evidence to recommend the use of pH testing (the intervention under scrutiny) for verification of correct placement of nasogastric tubes in adults and children. To this end, we will attempt to answer the following questions: 1. In adults and children, is pH testing an effective and safe method for determining whether nasogastric tubes are correctly positioned in the stomach before feeding (or delivery of any fluid) begins? 2. What evidence is there about the risk of adverse events in the case of incorrect placement? For this review, pH testing is defined as: litmus paper, pH indicator test strips, pH meters. These will be tested against other methods used for detecting placement of nasogastric tubes, including visual examination of aspirate, auscultation with insufflation of air, detection of air bubbles in a bowl of water, X-ray, ultrasonography, endoscopy, enzyme analysis of aspirate, capnography, and other methods that do not rely on measurement of pH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Eating Disorder Risk Composite (EDRC) comprises the Drive for Thinness, Bulimia, and Body Dissatisfaction subscales of the Eating Disorder Inventory, Third Edition (EDI-3, Garner, 2004). Past research conducted with Latina college women (LCW) has found older versions of the EDRC subscales to be reliable, but the EDI-3's EDRC factor structure has yet to be studied among LCW. The present study investigated the pattern of responses to and the factor structure of the EDRC in LCW. It was hypothesized that eating pathology would be present and that a factor analysiswould find some discrepancies between the original factor structure of the EDRC and the factor structure from LCW. Analyses of data on a 6-point Likert scale indicate that drive for thinness and body dissatisfaction are far more prevalent than is bulimic symptomology in LCW. Principal Axis Factoring with promax rotation was used to extract three factors very similar to the original EDRC. Some discrepancies in the item loadings were observed, most notably that half of the items from the original Body Dissatisfaction subscale did not load together on one factor. Overall, the EDRC appears to be a goodmeasurement of eating- and body-related phenomena among LCW. Implications, limitations, and future directions are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we detail the development of two stakeholder relationships scales. The scales measure major project managers' perceived competence in developing (establishing and maintaining) high quality, effective relationships with stakeholders who are internal and external to their organization. Our sample consists of 373 major project managers from a sub-set of the Australian defense industry. Both the internal stakeholder relationships scale and the external stakeholder relationships scale demonstrated validity and reliability. This research has implications for the interpersonal work relationships literature and the stakeholder management literature. We recommend that researchers test these scales with multiple samples, across different project types and project industries in the future. The stakeholder relationship scales should be versatile enough to be applied to project management generally but are perhaps best suited to major project environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Greenhouse gas (GHG) emissions are simultaneously exhausting the world's supply of fossil fuels and threatening the global climate. In many developing countries, significant improvement in living standards in recent years due to the accelerating development of their economies has resulted in a disproportionate increase in household energy consumption. Therefore, a major reduction in household carbon emissions (HCEs) is essential if global carbon reduction targets are to be met. To do this, major Organisation for Economic Co-operation and Development (OECD) states have already implemented policies to alleviate the negative environmental effects of household behaviors and less carbon-intensive technologies are also proposed to promote energy efficiency and reduce carbon emissions. However, before any further remedial actions can be contemplated, though, it is important to fully understand the actual causes of such large HCEs and help researchers both gain deep insights into the development of the research domain and identify valuable research topics for future study. This paper reviews existing literature focusing on the domain of HCEs. This critical review provides a systematic understanding of current work in the field, describing the factors influencing HCEs under the themes of household income, household size, age, education level, location, gender and rebound effects. The main quantification methodologies of input–output models, life cycle assessment and emission coefficient methods are also presented, and the proposed measures to mitigate HCEs at the policy, technology and consumer levels. Finally, the limitations of work done to date and further research directions are identified for the benefit of future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents an improved Phase-Locked Loop (PLL) for measuring the fundamental frequency and selective harmonic content of a distorted signal. This information can be used by grid interfaced devices and harmonic compensators. The single-phase structure is based on the Synchronous Reference Frame (SRF) PLL. The proposed PLL needs only a limited number of harmonic stages by incorporating Moving Average Filters (MAF) for eliminating the undesired harmonic content at each stage. The frequency dependency of MAF in effective filtering of undesired harmonics is also dealt with by a proposed method for adaptation to frequency variations of input signal. The method is suitable for high sampling rates and a wide frequency measurement range. Furthermore, an extended model of this structure is proposed which includes the response to both the frequency and phase angle variations. The proposed algorithm is simulated and verified using Hardware-in-the-Loop (HIL) testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of radon ((222)Rn) activity flux using activated charcoal canisters was examined to investigate the distribution of the adsorbed (222)Rn in the charcoal bed and the relationship between (222)Rn activity flux and exposure time. The activity flux of (222)Rn from five sources of varying strengths was measured for exposure times of one, two, three, five, seven, 10, and 14 days. The distribution of the adsorbed (222)Rn in the charcoal bed was obtained by dividing the bed into six layers and counting each layer separately after the exposure. (222)Rn activity decreased in the layers that were away from the exposed surface. Nevertheless, the results demonstrated that only a small correction might be required in the actual application of charcoal canisters for activity flux measurement, where calibration standards were often prepared by the uniform mixing of radium ((226)Ra) in the matrix. This was because the diffusion of (222)Rn in the charcoal bed and the detection efficiency as a function of the charcoal depth tended to counterbalance each other. The influence of exposure time on the measured (222)Rn activity flux was observed in two situations of the canister exposure layout: (a) canister sealed to an open bed of the material and (b) canister sealed over a jar containing the material. The measured (222)Rn activity flux decreased as the exposure time increased. The change in the former situation was significant with an exponential decrease as the exposure time increased. In the latter case, lesser reduction was noticed in the observed activity flux with respect to exposure time. This reduction might have been related to certain factors, such as absorption site saturation or the back diffusion of (222)Rn gas occurring at the canister-soil interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – Ideally, there is no wear in hydrodynamic lubrication regime. A small amount of wear occurs during start and stop of the machines and the amount of wear is so small that it is difficult to measure with accuracy. Various wear measuring techniques have been used where out-of-roundness was found to be the most reliable method of measuring small wear quantities in journal bearings. This technique was further developed to achieve higher accuracy in measuring small wear quantities. The method proved to be reliable as well as inexpensive. The paper aims to discuss these issues. Design/methodology/approach – In an experimental study, the effect of antiwear additives was studied on journal bearings lubricated with oil containing solid contaminants. The test duration was too long and the wear quantities achieved were too small. To minimise the test duration, short tests of about 90 min duration were conducted and wear was measured recording changes in variety of parameters related to weight, geometry and wear debris. The out-of-roundness was found to be the most effective method. This method was further refined by enlarging the out-of-roundness traces on a photocopier. The method was proved to be reliable and inexpensive. Findings – Study revealed that the most commonly used wear measurement techniques such as weight loss, roughness changes and change in particle count were not adequate for measuring small wear quantities in journal bearings. Out-of-roundness method with some refinements was found to be one of the most reliable methods for measuring small wear quantities in journal bearings working in hydrodynamic lubrication regime. By enlarging the out-of-roundness traces and determining the worn area of the bearing cross-section, weight loss in bearings was calculated, which was repeatable and reliable. Research limitations/implications – This research is a basic in nature where a rudimentary solution has been developed for measuring small wear quantities in rotary devices such as journal bearings. The method requires enlarging traces on a photocopier and determining the shape of the worn area on an out-of-roundness trace on a transparency, which is a simple but a crude method. This may require an automated procedure to determine the weight loss from the out-of-roundness traces directly. This method can be very useful in reducing test duration and measuring wear quantities with higher precision in situations where wear quantities are very small. Practical implications – This research provides a reliable method of measuring wear of circular geometry. The Talyrond equipment used for measuring the change in out-of-roundness due to wear of bearings indicates that this equipment has high potential to be used as a wear measuring device also. Measurement of weight loss from the traces is an enhanced capability of this equipment and this research may lead to the development of a modified version of Talyrond type of equipment for wear measurements in circular machine components. Originality/value – Wear measurement in hydrodynamic bearings requires long duration tests to achieve adequate wear quantities. Out-of-roundness is one of the geometrical parameters that changes with progression of wear in a circular shape components. Thus, out-of-roundness is found to be an effective wear measuring parameter that relates to change in geometry. Method of increasing the sensitivity and enlargement of out-of-roundness traces is original work through which area of worn cross-section can be determined and weight loss can be derived for materials of known density with higher precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the results of the time dispersion parameters obtained from a set of channel measurements conducted in various environments that are typical of multiuser Infostation application scenarios are presented. The measurement procedure takes into account the practical scenarios typical of the positions and movements of the users in the particular Infostation network. To provide one with the knowledge of how much data can be downloaded by users over a given time and mobile speed, data transfer analysis for multiband orthogonal frequency division multiplexing (MB-OFDM) is presented. As expected, the rough estimate of simultaneous data transfer in a multiuser Infostation scenario indicates dependency of the percentage of download on the data size, number and speed of the users, and the elapse time.