394 resultados para D stability
Resumo:
In this paper, we report the design and synthesis of isoindigo based low band gap polymer semiconductors, poly{N,N′-(2-octyldodecyl)-isoindigo-alt- naphthalene} (PISD-NAP) and poly{N,N′-(2-octyldodecyl)-isoindigo-alt- anthracene} (PISD-ANT). A series of donor-acceptor (D-A) copolymers can be prepared where donor and acceptor conjugated blocks can be attached alternately using organometallic coupling. In these polymers, an isoindigo dye acceptor moiety has been attached alternately with naphthalene and anthracene donor comonomer blocks by Suzuki coupling. PISD-NAP and PISD-ANT exhibit excellent solution processibility and good film-forming properties. Gel permeation chromatography exhibits a higher molecular mass with lower polydispersity. UV-vis-NIR absorption of these polymers exhibits a wide absorption band ranging from 300 nm to 800 nm, indicating the low band gap nature of the polymers. Optical band gaps calculated from the solid state absorption cutoff value for PISD-NAP and PISD-ANT are around 1.80 eV and 1.75 eV, respectively. Highest occupied molecular orbital (HOMO) values calculated respectively for PISD-NAP and PISD-ANT thin films on glass substrate by photoelectron spectroscopy in air (PESA) are 5.66 eV and 5.53 eV, indicative of the good stability of these materials in organic electronic device applications. These polymers exhibit p-channel charge transport characteristics when used as the active semiconductor in organic thin-film transistor (OTFT) devices in ambient conditions. The highest hole mobility of 0.013 cm2 V-1 s-1 is achieved in top contact and bottom-gate OTFT devices for PISD-ANT, whereas polymer PISD-NAP exhibited a hole mobility of 0.004 cm2 V -1 s-1. When these polymer semiconductors were used as a donor and PC71BM as an acceptor in OPV devices, the highest power conversion efficiency (PCE) of 1.13% is obtained for the PISD-ANT polymer.
Resumo:
New push-pull copolymers based on thiophene (donor) and benzothiadiazole (acceptor) units, poly[4,7-bis(3-dodecylthiophene-2-yl) benzothiadiazole-co- thiophene] (PT3B1) and poly[4,7-bis(3-dodecylthiophene-2-yl) benzothiadiazole-co-benzothiadiazole] (PT2B2), are designed and synthesized via Stille and Suzuki coupling routes respectively. Gel permeation chromatography shows the number average molecular weights are 31100 and 8400 g mol-1 for the two polymers, respectively. Both polymers have shown absorption throughout a wide range of the UV-vis region, from 300 to 650 nm. A significant red shift of the absorption edge is observed in thin films compared to solution of the copolymers; the optical band gap is in the range of 1.7 to 1.8 eV. Cyclic voltammetry indicates reversible oxidation and reduction processes with HOMO energy levels calculated to be in the range of 5.2 to 5.4 eV. Upon testing both materials for organic field-effect transistors (OFETs), PT3B1 showed a hole mobility of 6.1 × 10-4 cm2 V-1 s -1, while PT2B2 did not show any field effect transport. Both copolymers displayed a photovoltaic response when combined with a methanofullerene as an electron acceptor. The best performance was achieved when the copolymer PT3B1 was blended with [70]PCBM in a 1:4 ratio, exhibiting a short-circuit current of 7.27 mA cm-2, an open circuit voltage of 0.85 V, and a fill factor of 41% yielding a power conversion efficiency of 2.54% under simulated air mass (AM) 1.5 global (1.5 G) illumination conditions (100 mW cm-2). Similar devices utilizing PT2B2 in place of PT3B1 demonstrated reduced performance with a short-circuit current of 4.8 mA cm -2, an open circuit voltage of 0.73 V, and a fill factor of 30% resulting in a power conversion efficiency of roughly 1.06%.
Resumo:
A novel solution processable donor-acceptor (D-A) based low band gap polymer semiconductor poly{3,6-difuran-2-yl-2,5-di(2-octyldodecyl)-pyrrolo[3,4- c]pyrrole-1,4-dione-alt-thienylenevinylene} (PDPPF-TVT), was designed and synthesized by a Pd-catalyzed Stille coupling route. An electron deficient furan based diketopyrrolopyrrole (DPP) block and electron rich thienylenevinylene (TVT) donor moiety were attached alternately in the polymer backbone. The polymer exhibited good solubility, film forming ability and thermal stability. The polymer exhibits wide absorption bands from 400 nm to 950 nm (UV-vis-NIR region) with absorption maximum centered at 782 nm in thin film. The optical band gap (Eoptg) calculated from the polymer film absorption onset is around 1.37 eV. The π-energy band level (ionization potential) calculated by photoelectron spectroscopy in air (PESA) for PDPPF-TVT is around 5.22 eV. AFM and TEM analyses of the polymer reveal nodular terrace morphology with optimized crystallinity after 200 °C thermal annealing. This polymer exhibits p-channel charge transport characteristics when used as the active semiconductor in organic thin-film transistor (OTFT) devices. The highest hole mobility of 0.13 cm 2 V -1 s -1 is achieved in bottom gate and top-contact OTFT devices with on/off ratios in the range of 10 6-10 7. This work reveals that the replacement of thiophene by furan in DPP copolymers exhibits such a high mobility, which makes DPP furan a promising block for making a wide range of promising polymer semiconductors for broad applications in organic electronics.
Resumo:
A power electronics-based buffer is examined in which through control of its PWM converters, the buffer-load combination is driven to operate under either constant power or constant impedance modes. A battery, incorporated within the buffer, provides the energy storage facility to facilitate the necessary power flow control. Real power demand from upstream supply is regulated under fault condition, and the possibility of voltage or network instability is reduced. The proposed buffer is also applied to a wind farm. It is shown that the buffer stabilizes the power contribution from the farm. Based on a battery cost-benefit analysis, a method is developed to determine the optimal level of the power supplied from the wind farm and the corresponding capacity of the battery storage system.
Resumo:
Purpose We examined the age-dependent alterations and longitudinal course of subbasal nerve plexus (SNP) morphology in healthy individuals. Methods Laser-scanning corneal confocal microscopy, ocular screening, and health and metabolic assessment were performed on 64 healthy participants at baseline and at 12-month intervals for 3 years. At each annual visit, eight central corneal images of the SNP were selected and analyzed using a fully-automated analysis system to quantify corneal nerve fiber length (CNFL). Two linear mixed model approaches were fitted to examine the relationship between age and CNFL, and the longitudinal changes of CNFL over three years. Results At baseline, mean age was 51.9 ± 14.7 years. The cohort was sex balanced (χ2 = 0.56, P = 0.45). Age (t = 1.6, P = 0.12) and CNFL (t = -0.50, P = 0.62) did not differ between sexes. A total of 52 participants completed the 36-month visit and 49 participants completed all visits. Age had a significant effect on CNFL (F1,33 = 5.67, P = 0.02) with a linear decrease of 0.05 mm/mm2 in CNFL per one year increase in age. No significant change in CNFL was observed over the 36-month period (F1,55 = 0.69, P = 0.41). Conclusions The CNFL showed a stable course over a 36-month period in healthy individuals, although there was a slight linear reduction in CNFL with age. The findings of this study have implications for understanding the time-course of the effect of pathology and surgical or therapeutic interventions on the morphology of the SNP, and serves to confirm the suitability of CNFL as a screening/monitoring marker for peripheral neuropathies.
Resumo:
In order to investigate the chromosomal genotoxicity of nitrobenzene and benzonitrile, we studied the induction of micronuclei (MN) by these test compounds in V79 cells, as well as effects on the formation and stability of microtubules and on motor protein functions. No cytotoxicity was seen in V79 cell cultures in terms of Neutral red uptake after 18 h treatment with up to 1 mM nitrobenzene or 1 mM benzonitrile. Subsequently, a concentration range up to 100 μM was used in the experiments on induction of MN. Both test compounds exhibit a weak, but definitely positive test result compared to the solvent (DMSO) control. Minimal effect concentrations of nitrobenzene and benzonitrile appeared as low as 0.01 μM, and no-effect-concentrations were between 0.001 and 0.005 μM. Clearly enhanced MN rates were found at 0.1 μM and higher. Both, nitrobenzene and benzonitrile, induced mostly kinetochor (CREST)-positive micronuclei, thus characterising the chromosomal effects as aneugenic. In cell-free assays, a slight effect on tubulin assembly was observed at 1 mM nitrobenzene without addition of DMSO. Higher concentrations (5 mM) led to secondary effects. In presence of 1% DMSO, nitrobenzene exerted no detectable effect on tubulin assembly up to the solubility limit in water of about 15 mM. For benzonitrile in presence of DMSO, a clear dose-response of inhibition of tubulin assembly at 37°C was seen above the no-effect-concentration of 2 mM, with an IC50 of 13 mM and protein denaturation starting above a level of about 20 mM. The nature of the effects of nitrobenzene and benzonitrile on the association of tubulin to form microtubules was confirmed by electron microscopy. Treatment by either 5 mM nitrobenzene or 13 mM benzonitrile plus 1% DMSO left the microtubular structure intact whereas 5 mM nitrobenzene, in absence of DMSO, led to irregular cluster formations. The experiments demonstrate that both nitrobenzene and benzonitrile, in millimolar concentration ranges, may lead to interference with tubulin assembly in a cell-free system. The functionality of the tubulin-kinesin motor protein system was assessed using the microtubule gliding assay. Nitrobenzene affected the gliding velocity in a concentration-dependent manner, starting at about 7.5 μM and reaching complete inhibition of motility at 30 μM, whereas benzonitrile up to 200 μM did not affect the kinesin-driven gliding velocity. The micronucleus assay data demonstrate a chromosomal endpoint of genotoxicity of nitrobenzene and benzonitrile. Aneugenic effects of both compounds occur at remarkably low concentrations, with lowest-effect-concentrations being 0.1 μM. This points to the relevance of interactions with the cellular spindle apparatus.
Hydrolysis of genotoxic methyl-substituted oxiranes : Experimental kinetic and semiempirical studies
Resumo:
The kinetics of acid-catalyzed hydrolysis of seven methylated aliphatic epoxides - R1R2C(O)CR3R4 (A: R1=R2=R3=R4=H; B: R1=R2=R3=H, R4=Me; C: R1=R2=H, R3=R4=Me; D: R1=R3=H, R2=R4=Me(trans); E: R1=R3=H, R2=R4=Me(cis); F: R1=R3=R4=Me, R2=H; G: R1=R2=R3=R4=Me) - has been studied at 36 ± 1.5°C. Compounds with two methyl groups at the same carbon atom of the oxirane ring exhibit highest rate constants (k(eff) in reciprocal molar concentration per second: 11.0 ± 1.3 for C, 10.7 ± 2.1 for F, and 8.7 ± 0.7 for G as opposed to 0.124 ± 0.003 for B, 0.305 ± 0.003 for D, and 0.635 ± 0.036 for E). Ethylene oxide (A) displays the lowest rate of hydrolysis (0.027 M-1 s-1). The results are consistent with literature data available for compounds A, B, and C. To model the reactivities we have employed quantum chemical calculations (MNDO, AM1, PM3, and MINDO/3) of the main reaction species. There is a correlation of the logarithm k(eff) with the total energy of epoxide ring opening. The best correlation coefficients (r) were obtained using the AM1 and MNDO methods (0.966 and 0.957, respectively). However, unlike MNDO, AM1 predicts approximately zero energy barriers for the oxirane ring opening of compounds B, C, E and G, which is not consistent with published kinetic data. Thus, the MNDO method provides a preferential means of modeling the acidic hydrolysis of the series of methylated oxiranes. The general ranking of mutagenicity in vitro, A > B > C, is in line with the concept that this sequence also gradually leaves the expoxide reactivity optimal for genotoxicity toward reactivities leading to higher biological detoxifications.
Resumo:
Firstly, we would like to thank Ms. Alison Brough and her colleagues for their positive commentary on our published work [1] and their appraisal of our utility of the “off-set plane” protocol for anthropometric analysis. The standardized protocols described in our manuscript have wide applications, ranging from forensic anthropology and paleodemographic research to clinical settings such as paediatric practice and orthopaedic surgical design. We affirm that the use of geometrically based reference tools commonly found in computer aided design (CAD) programs such as Geomagic Design X® are imperative for more automated and precise measurement protocols for quantitative skeletal analysis. Therefore we stand by our recommendation of the use of software such as Amira and Geomagic Design X® in the contexts described in our manuscript...
Resumo:
Dendrimers have potential for delivering chemotherapeutic drugs to solid tumours via the enhanced permeation and retention (EPR) effect. The impact of conjugation of hydrophobic anticancer drugs to hydrophilic PEGylated dendrimer surfaces, however, has not been fully investigated. The current study has therefore characterised the effect on dendrimer disposition of conjugating α-carboxyl protected methotrexate (MTX) to a series of PEGylated 3H-labelled poly-L-lysine dendrimers ranging in size from generation 3 (G3) to 5 (G5) in rats. Dendrimers contained 50% surface PEG and 50% surface MTX. Conjugation of MTX generally increased plasma clearance when compared to conjugation with PEG alone. Conversely, increasing generation reduced clearance, increased metabolic stability and reduced renal elimination of the administered radiolabel. For constructs with molecular weights >20 kDa increasing the molecular weight of conjugated PEG also reduced clearance and enhanced metabolic stability but had only a minimal effect on renal elimination. Tissue distribution studies revealed retention of MTX conjugated smaller (G3-G4) PEG570 dendrimers (or their metabolic products) in the kidneys. In contrast, the larger G5 dendrimer was concentrated more in the liver and spleen. The G5 PEG1100 dendrimer was also shown to accumulate in solid Walker 256 and HT1080 tumours and comparative disposition data in both rats (1 to 2% dose/g in tumour) and mice (11% dose/g in tumour) are presented. The results of this study further illustrate the potential utility of biodegradable PEGylated poly-L-lysine dendrimers as long circulating vectors for the delivery and tumour-targeting of hydrophobic drugs.