431 resultados para routine outcome measurement
Resumo:
Musculoskeletal health can be compromised by breast cancer treatment. In particular, bone loss and arthralgias are prevalent side effects experienced by women treated with chemotherapy and/or adjuvant endocrine therapy. Bone loss leads to osteoporosis and related fractures, while arthralgias threaten quality of life and compliance to treatment. Because the processes that lead to these musculoskeletal problems are initiated when treatment begins, early identification of women who may be at higher risk of developing problems, routine monitoring of bone density and pain at certain stages of treatment, and prudent application of therapeutic interventions are key to preventing and/or minimizing musculoskeletal sequelae. Exercise may be a particularly suitable intervention strategy because of its potential to address a number of impairments; it may slow bone loss, appears to reduce joint pain in noncancer conditions, and improves other breast cancer outcomes. Research efforts continue in the areas of etiology, measurement, and treatment of bone loss and arthralgias. The purpose of this review is to provide an overview of the current knowledge on the management and treatment of bone loss and arthralgias in breast cancer survivors and to present a framework for rehabilitation care to preserve musculoskeletal health in women treated for breast cancer.
Resumo:
Magnetic resonance imaging (MRI) offers the opportunity to study biological tissues and processes in a non-disruptive manner. The technique shows promise for the study of the load-bearing performance (consolidation) of articular cartilage and changes in articular cartilage accompanying osteoarthritis. Consolidation of articular cartilage involves the recording of two transient characteristics: the change over time of strain and the hydrostatic excess pore pressure (HEPP). MRI study of cartilage consolidation under mechanical load is limited by difficulties in measuring the HEPP in the presence of the strong magnetic fields associated with the MRI technique. Here we describe the use of MRI to image and characterize bovine articular cartilage deforming under load in an MRI compatible consolidometer while monitoring pressure with a Fabry-Perot interferometer-based fiber-optic pressure transducer.
Resumo:
Background The measurement of severity and control of asthma in both children and adults can be based on subjective or objective measures. It has been advocated that fractional exhaled nitric oxide (FeNO) can be used to monitor airway inflammation as it correlates with some markers of asthma. Interventions for asthma therapies have been traditionally based on symptoms and/or spirometry. Objectives To evaluate the efficacy of tailoring asthma interventions based on exhaled nitric oxide in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. Search methods We searched the Cochrane Airways Group Specialised Register of Trials, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and reference lists of articles. The last search was completed in February 2009. Selection criteria All randomised controlled comparisons of adjustment of asthma therapy based on exhaled nitric oxide compared to traditional methods (primarily clinical symptoms and spirometry/peak flow). Data collection and analysis Results of searches were reviewed against pre-determined criteria for inclusion. Relevant studies were independently selected in duplicate. Two authors independently assessed trial quality and extracted data. Authors were contacted for further information with response from one. Main results Two studies have been added for this update, which now includes six (2 adults and 4 children/adolescent) studies; these studies differed in a variety of ways including definition of asthma exacerbations, FeNO cut off levels, the way in which FeNO was used to adjust therapy and duration of study. Of 1053 participants randomised, 1010 completed the trials. In the meta-analysis, there was no significant difference between groups for the primary outcome of asthma exacerbations or for other outcomes (clinical symptoms, FeNO level and spirometry). In post-hoc analysis, a significant reduction in mean final daily dose inhaled corticosteroid per adult was found in the group where treatment was based on FeNO in comparison to clinical symptoms, (mean difference -450 mcg; 95% CI -677 to -223 mcg budesonide equivalent/day). However, the total amount of inhaled corticosteroid used in one of the adult studies was 11% greater in the FeNO arm. In contrast, in the paediatric studies, there was a significant increase in inhaled corticosteroid dose in the FeNO strategy arm (mean difference of 140 mcg; 95% CI 29 to 251, mcg budesonide equivalent/day). Authors' conclusions Tailoring the dose of inhaled corticosteroids based on exhaled nitric oxide in comparison to clinical symptoms was carried out in different ways in the six studies and found only modest benefit at best and potentially higher doses of inhaled corticosteroids in children. The role of utilising exhaled nitric oxide to tailor the dose of inhaled corticosteroids cannot be routinely recommended for clinical practice at this stage and remains uncertain.
Resumo:
Background Despite the commonality of cough and its burden, there are no published data on the relationship between atopy or sex on objectively measured cough frequency or subjective cough scores in children. In 202 children with and without cough, we determined the effect of sex and atopy on validated cough outcome measurements (cough receptor sensitivity [CRS], objective cough counts, and cough scores). We hypothesized that in contrast to adult data, sex does not influence cough outcome measures, and atopy is not a determinant of these cough measurements. Methods We combined data from four previous studies. Atopy (skin prick test), the concentration of capsaicin causing two and five or more coughs (C2 and C5, respectively), objectively measured cough frequency, and cough scores were determined and their relationship explored. The children’s (93 girls, 109 boys) mean age was 10.6 years (SD 2.9), and 56% had atopy. Results In multivariate analysis, CRS was influenced by age (C2 coefficient, 5.9; P = .034; C5 coefficient, 29.1; P = .0001). Atopy and sex did not significantly influence any of the cough outcomes (cough counts, C2, C5, cough score) in control subjects and children with cough. Conclusions Atopy does not influence important cough outcome measures in children with and without chronic cough. However, age, but not sex, influences CRS in children. Unlike adult data, sex does not affect objective counts or cough score in children with and without chronic cough. Studies on cough in children should be age matched, but matching for atopic status and sex is less important.
Resumo:
This thesis describes the investigation of an Aircraft Dynamic Navigation (ADN) approach, which incorporates an Aircraft Dynamic Model (ADM) directly into the navigation filter of a fixed-wing aircraft or UAV. The result is a novel approach that offers both performance improvements and increased reliability during short-term GPS outages. This is important in allowing future UAVs to achieve routine, unconstrained, and safe operations in commercial environments. The primary contribution of this research is the formulation Unscented Kalman Filter (UKF) which incorporates a complex, non-linear, laterally and longitudinally coupled, ADM, and sensor suite consisting of a Global Positioning System (GPS) receiver, Inertial Measurement Unit (IMU), Electronic Compass (EC), and Air Data (AD) Pitot Static System.
Resumo:
Introduction This study investigated the sensitivity of calculated stereotactic radiotherapy and radiosurgery doses to the accuracy of the beam data used by the treatment planning system. Methods Two sets of field output factors were acquired using fields smaller than approximately 1 cm2, for inclusion in beam data used by the iPlan treatment planning system (Brainlab, Feldkirchen, Germany). One set of output factors were measured using an Exradin A16 ion chamber (Standard Imaging, Middleton, USA). Although this chamber has a relatively small collecting volume (0.007 cm3), measurements made in small fields using this chamber are subject to the effects of volume averaging, electronic disequilibrium and chamber perturbations. The second, more accurate, set of measurements were obtained by applying perturbation correction factors, calculated using Monte Carlo simulations according to a method recommended by Cranmer-Sargison et al. [1] to measurements made using a 60017 unshielded electron diode (PTW, Freiburg, Germany). A series of 12 sample patient treatments were used to investigate the effects of beam data accuracy on resulting planned dose. These treatments, which involved 135 fields, were planned for delivery via static conformal arcs and 3DCRT techniques, to targets ranging from prostates (up to 8 cm across) to meningiomas (usually more than 2 cm across) to arterioveinous malformations, acoustic neuromas and brain metastases (often less than 2 cm across). Isocentre doses were calculated for all of these fields using iPlan, and the results of using the two different sets of beam data were evaluated. Results While the isocentre doses for many fields are identical (difference = 0.0 %), there is a general trend for the doses calculated using the data obtained from corrected diode measurements to exceed the doses calculated using the less-accurate Exradin ion chamber measurements (difference\0.0 %). There are several alarming outliers (circled in the Fig. 1) where doses differ by more than 3 %, in beams from sample treatments planned for volumes up to 2 cm across. Discussion and conclusions These results demonstrate that treatment planning dose calculations for SRT/SRS treatments can be substantially affected when beam data for fields smaller than approximately 1 cm2 are measured inaccurately, even when treatment volumes are up to 2 cm across.
Accelerometer data reduction : a comparison of four reduction algorithms on select outcome variables
Resumo:
Purpose Accelerometers are recognized as a valid and objective tool to assess free-living physical activity. Despite the widespread use of accelerometers, there is no standardized way to process and summarize data from them, which limits our ability to compare results across studies. This paper a) reviews decision rules researchers have used in the past, b) compares the impact of using different decision rules on a common data set, and c) identifies issues to consider for accelerometer data reduction. Methods The methods sections of studies published in 2003 and 2004 were reviewed to determine what decision rules previous researchers have used to identify wearing period, minimal wear requirement for a valid day, spurious data, number of days used to calculate the outcome variables, and extract bouts of moderate to vigorous physical activity (MVPA). For this study, four data reduction algorithms that employ different decision rules were used to analyze the same data set. Results The review showed that among studies that reported their decision rules, much variability was observed. Overall, the analyses suggested that using different algorithms impacted several important outcome variables. The most stringent algorithm yielded significantly lower wearing time, the lowest activity counts per minute and counts per day, and fewer minutes of MVPA per day. An exploratory sensitivity analysis revealed that the most stringent inclusion criterion had an impact on sample size and wearing time, which in turn affected many outcome variables. Conclusions These findings suggest that the decision rules employed to process accelerometer data have a significant impact on important outcome variables. Until guidelines are developed, it will remain difficult to compare findings across studies
Resumo:
Background Parents play a significant role in shaping youth physical activity (PA). However, interventions targeting PA parenting have been ineffective. Methodological inconsistencies related to the measurement of parental influences may be a contributing factor. The purpose of this article is to review the extant peer-reviewed literature related to the measurement of general and specific parental influences on youth PA. Methods A systematic review of studies measuring constructs of PA parenting was conducted. Computerized searches were completed using PubMed, MEDLINE, Academic Search Premier, SPORTDiscus, and PsycINFO. Reference lists of the identified articles were manually reviewed as well as the authors' personal collections. Articles were selected on the basis of strict inclusion criteria and details regarding the measurement protocols were extracted. A total of 117 articles met the inclusionary criteria. Methodological articles that evaluated the validity and reliability of PA parenting measures (n=10) were reviewed separately from parental influence articles (n=107). Results A significant percentage of studies used measures with indeterminate validity and reliability. A significant percentage of articles did not provide sample items, describe the response format, or report the possible range of scores. No studies were located that evaluated sensitivity to change. Conclusion The reporting of measurement properties and the use of valid and reliable measurement scales need to be improved considerably.
Resumo:
Physical activity (PA) parenting research has proliferated over the past decade, with findings verifying the influential role that parents play in children's emerging PA behaviors. This knowledge, however, has not translated into effective family-based PA interventions. During a preconference workshop to the 2012 International Society for Behavioral Nutrition and Physical Activity annual meeting, a PA parenting workgroup met to: (1) Discuss challenges in PA parenting research that may limit its translation, (2) identify explanations or reasons for such challenges, and; (3) recommend strategies for future research. Challenges discussed by the workgroup included a proliferation of disconnected and inconsistently measured constructs, a limited understanding of the dimensions of PA parenting, and a narrow conceptualization of hypothesized moderators of the relationship between PA parenting and child PA. Potential reasons for such challenges emphasized by the group included a disinclination to employ theory when developing measures and examining predictors and outcomes of PA parenting as well as a lack of agreed-upon measurement standards. Suggested solutions focused on the need to link PA parenting research with general parenting research, define and adopt rigorous standards of measurement, and identify new methods to assess PA parenting. As an initial step toward implementing these recommendations, the workgroup developed a conceptual model that: (1) Integrates parenting dimensions from the general parenting literature into the conceptualization of PA parenting, (2) draws on behavioral and developmental theory, and; (3) emphasizes areas which have been neglected to date including precursors to PA parenting and effect modifiers.
Resumo:
The general aim of designated driver programs is to reduce the level of drink driving by encouraging potential drink drivers to travel with a driver who has abstained from (or at least limited) consuming alcohol. Designated driver programs appear to be quite widespread around the world, however a limited number have been subject to rigorous evaluation. This paper reports results from an outcome evaluation of a designated driver program called ‘Skipper’, which was trialled in a provincial city in Queensland, Australia. The outcome evaluation included surveys three weeks prior to (baseline), four months following (1st follow-up), and 16 months following (2nd follow-up) the commencement of the trial in both the ‘intervention area’ (baseline, n = 202; 1st follow-up, n = 211; 2nd follow-up, n = 200) and a ‘comparison area’(baseline, n = 203; 1st follow-up, n = 199; 2nd follow-up, n = 201); and a comparison of random breath testing and crash data before and after the trial. The survey results indicate that awareness of the program in the intervention area was quite high four months following its introduction and that this was maintained at 16 months. The results also suggest that the ‘Skipper’ program and the related publicity had positive impacts on behaviour with an increase in the proportion of people participating in designated driver as a passenger. It is less clear, however, whether the ‘Skipper’ program impacted on other behaviours of interest, such as drink driving or involvement in alcohol-related crashes. Suggestions for further research and program improvement are discussed as well as limitations of the research.
Resumo:
The concept of dispositional resistance to change has been introduced in a series of exploratory and confirmatory analyses through which the validity of the Resistance to Change (RTC) Scale has been established (S. Oreg, 2003). However, the vast majority of participants with whom the scale was validated were from the United States. The purpose of the present work was to examine the meaningfulness of the construct and the validity of the scale across nations. Measurement equivalence analyses of data from 17 countries, representing 13 languages and 4 continents, confirmed the cross-national validity of the scale. Equivalent patterns of relationships between personal values and RTC across samples extend the nomological net of the construct and provide further evidence that dispositional resistance to change holds equivalent meanings across nations.
Resumo:
Background Rapid developments in technology have encouraged the use of smartphones in physical activity research, although little is known regarding their effectiveness as measurement and intervention tools. Objective This study systematically reviewed evidence on smartphones and their viability for measuring and influencing physical activity. Data Sources Research articles were identified in September 2013 by literature searches in Web of Knowledge, PubMed, PsycINFO, EBSCO, and ScienceDirect. Study Selection The search was restricted using the terms (physical activity OR exercise OR fitness) AND (smartphone* OR mobile phone* OR cell phone*) AND (measurement OR intervention). Reviewed articles were required to be published in international academic peer-reviewed journals, or in full text from international scientific conferences, and focused on measuring physical activity through smartphone processing data and influencing people to be more active through smartphone applications. Study Appraisal and Synthesis Methods Two reviewers independently performed the selection of articles and examined titles and abstracts to exclude those out of scope. Data on study characteristics, technologies used to objectively measure physical activity, strategies applied to influence activity; and the main study findings were extracted and reported. Results A total of 26 articles (with the first published in 2007) met inclusion criteria. All studies were conducted in highly economically advantaged countries; 12 articles focused on special populations (e.g. obese patients). Studies measured physical activity using native mobile features, and/or an external device linked to an application. Measurement accuracy ranged from 52 to 100 % (n = 10 studies). A total of 17 articles implemented and evaluated an intervention. Smartphone strategies to influence physical activity tended to be ad hoc, rather than theory-based approaches; physical activity profiles, goal setting, real-time feedback, social support networking, and online expert consultation were identified as the most useful strategies to encourage physical activity change. Only five studies assessed physical activity intervention effects; all used step counts as the outcome measure. Four studies (three pre–post and one comparative) reported physical activity increases (12–42 participants, 800–1,104 steps/day, 2 weeks–6 months), and one case-control study reported physical activity maintenance (n = 200 participants; >10,000 steps/day) over 3 months. Limitations Smartphone use is a relatively new field of study in physical activity research, and consequently the evidence base is emerging. Conclusions Few studies identified in this review considered the validity of phone-based assessment of physical activity. Those that did report on measurement properties found average-to-excellent levels of accuracy for different behaviors. The range of novel and engaging intervention strategies used by smartphones, and user perceptions on their usefulness and viability, highlights the potential such technology has for physical activity promotion. However, intervention effects reported in the extant literature are modest at best, and future studies need to utilize randomized controlled trial research designs, larger sample sizes, and longer study periods to better explore the physical activity measurement and intervention capabilities of smartphones.
Resumo:
Intended to bridge the gap between the latest methodological developments and cross-cultural research, this interdisciplinary resource presents the latest strategies for analyzing cross-cultural data. Techniques are demonstrated through the use of applications that employ cross national data sets such as the latest European Social Survey. With an emphasis on the generalized latent variable approach, internationally?prominent researchers from a variety of fields explain how the methods work, how to apply them, and how they relate to other methods presented in the book. Syntax and graphical and verbal explanations of the techniques are included. [from publisher's website]
Resumo:
There is currently some debate about whether the energy expenditure of domestic tasks is sufficient to confer health benefits. The aim of this study was therefore to measure the energy cost of five activities commonly undertaken by mothers of young children. Seven women with at least one child younger than five years of age spent 15 minutes in each of the following activities: sitting quietly, vacuum cleaning, washing windows, walking at moderate pace (approx 5km/hour), walking with a stroller and grocery shopping in a super-market. Each of the six 'trials' was completed on the same day, in random order. A carefully calibrated portable gas analyser was used to measure oxygen uptake during each activity, and data were converted to units of energy expenditure (METS). Vacuum cleaning, washing windows and walking with and without a stroller were found to be 'moderate intensity activities' (3 to 6 METs), but supermarket shopping did not reach this criterion. The MET values for these activities were similar to those reported in the Compendium of Physical Activities (Ainsworth et al., 2000). However, the energy expenditures of walking, both with and without a stroller, were higher than those reported in the Compendium. The findings suggest that some of the tasks associated with domestic caring duties are conducted at an intensity which is sufficient to confer some health benefit. Such benefits will only accrue however if the daily duration of these activities is sufficient to meet current guidelines.
Resumo:
Purpose To evaluate the validity of a uniaxial accelerometer (MTI Actigraph) for measuring physical activity in people with acquired brain injury (ABI) using portable indirect calorimetry (Cosmed K4b(2)) as a criterion measure. Methods Fourteen people with ABI and related gait pattern impairment (age 32 +/- 8 yr) wore an MTI Actigraph that measured activity (counts(.)min-(1)) and a Cosmed K4b(2) that measured oxygen consumption (mL(.)kg(-1.)min(-1)) during four activities: quiet sitting (QS) and comfortable paced (CP), brisk paced (BP), and fast paced (FP) walking. MET levels were predicted from Actigraph counts using a published equation and compared with Cosmed measures. Predicted METs for each of the 56 activity bouts (14 participants X 4 bouts) were classified (light, moderate, vigorous, or very vigorous intensity) and compared with Cosmed-based classifications. Results Repeated-measures ANOVA indicated that walking condition intensities were significantly different (P < 0.05) and the Actigraph detected the differences. Overall correlation between measured and predicted METs was positive, moderate, and significant (r = 0.74). Mean predicted METs were not significantly different from measured for CP and BP, but for FP walking, predicted METs were significantly less than measured (P < 0.05). The Actigraph correctly classified intensity for 76.8% of all activity bouts and 91.5% of light- and moderate-intensity bouts. Conclusions Actigraph counts provide a valid index of activity across the intensities investigated in this study. For light to moderate activity, Actigraph-based estimates of METs are acceptable for group-level analysis and are a valid means of classifying activity intensity. The Actigraph significantly underestimated higher intensity activity, although, in practice, this limitation will have minimal impact on activity measurement of most community-dwelling people with ABI.