384 resultados para measurement accuracy
Resumo:
Performance measurement in Australian philanthropic foundations is a hot topic. Foundation staff and board members are concerned with striking the right balance between their need for information with which to assess the effectiveness of their grant-making programs, and the costs in both time and money for grantees. Influenced by normative pressures, the increasing size and professionalism of the Australian philanthropic sector, and trends from the U.S.A and the U.K, foundations are talking amongst themselves, seeking expert advice and training, consulting with grantees and trying different approaches. Many resources examine methods of data collection, measurement or analysis. Our study instead treads into less charted but important territory: the motivations and values that are shaping the debate about performance measurement. In a series of 40 interviews with foundations from Queensland, New South Wales, Victoria and South Australia, we asked whether they felt under pressure to measure performance and if so, why. We queried whether everyone in the foundation shared the same views on the purposes of performance measurement; and the ways in which the act of performance measurement changed their grant-making, their attitude to risk, their relationship with grantees and their collaborations with other funders. Unsurprisingly, a very diverse set of approaches to performance measurement were revealed.
Resumo:
Firstly, we would like to thank Ms. Alison Brough and her colleagues for their positive commentary on our published work [1] and their appraisal of our utility of the “off-set plane” protocol for anthropometric analysis. The standardized protocols described in our manuscript have wide applications, ranging from forensic anthropology and paleodemographic research to clinical settings such as paediatric practice and orthopaedic surgical design. We affirm that the use of geometrically based reference tools commonly found in computer aided design (CAD) programs such as Geomagic Design X® are imperative for more automated and precise measurement protocols for quantitative skeletal analysis. Therefore we stand by our recommendation of the use of software such as Amira and Geomagic Design X® in the contexts described in our manuscript...
Resumo:
This study demonstrates a novel technique of preparing drug colloid probes to determine the adhesion force between a model drug salbutamol sulphate (SS) and the surfaces of polymer microparticles to be used as carriers for the dispersion of drug particles from dry powder inhaler (DPI) formulations. Model silica probes of approximately 4 lm size, similar to a drug particle used in DPI formulations, were coated with a saturated SS solution with the aid of capillary forces acting between the silica probe and the drug solution. The developed method of ensuring a smooth and uniform layer of SS on the silica probe was validated using X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM). Using the same technique, silica microspheres pre-attached on the AFM cantilever were coated with SS. The adhesion forces between the silica probe and drug coated silica (drug probe) and polymer surfaces (hydrophilic and hydrophobic) were determined. Our experimental results showed that the technique for preparing the drug probe was robust and can be used to determine the adhesion force between hydrophilic/ hydrophobic drug probe and carrier surfaces to gain a better understanding on drug carrier adhesion forces in DPI formulations.
Resumo:
Capacity measurement and reduction is a major international issue to emerge in the new millennium. However, there has been limited assessment of the success of capacity reduction schemes (CRS). In this paper, the success of a CRS is assessed for a European fishery characterised by differences in efficiency levels of individual boats. In such a fishery, given it is assumed that the least efficient producers are the first to exit through a CRS, the reduction in harvesting capacity is less than the nominal reduction in physical fleet capacity. Further, there is potential for harvesting capacity to increase if remaining vessels improve their efficiency.
Resumo:
RATIONALE Diseases including cancer and congenital disorders of glycosylation have been associated with changes in the site-specific extent of protein glycosylation. Saliva can be non-invasively sampled and is rich in glycoproteins, giving it the potential to be a useful biofluid for the discovery and detection of disease biomarkers associated with changes in glycosylation. METHODS Saliva was collected from healthy individuals and glycoproteins were enriched using phenylboronic acid based glycoprotein enrichment resin. Proteins were deglycosylated with peptide-N-glycosidase F and digested with AspN or trypsin. Desalted peptides and deglycosylated peptides were separated by reversed-phase liquid chromatography and detected with on-line electrospray ionization quadrupole-time-of-flight mass spectrometry using a 5600 TripleTof instrument. Site-specific glycosylation occupancy was semi-quantitatively determined from the abundance of deglycosylated and nonglycosylated versions of each given peptide. RESULTS Glycoprotein enrichment identified 67 independent glycosylation sites from 24 unique proteins, a 3.9-fold increase in the number of glycosylation sites identified. Enrichment of glycoproteins rather than glycopeptides allowed detection of both deglycosylated and nonglycosylated versions of each peptide, and thereby robust measurement of site-specific occupancy at 21 asparagines. Healthy individuals showed limited biological variability in occupancy, with partially modified sites having characteristics consistent with inefficient glycosylation by oligosaccharyltransferase. Inclusion of negative controls without enzymatic deglycosylation controlled for spontaneous chemical deamidation, and identified asparagines previously incorrectly annotated as glycosylated. CONCLUSIONS We developed a sample preparation and mass spectrometry detection strategy for rapid and efficient measurement of site-specific glycosylation occupancy on diverse salivary glycoproteins suitable for biomarker discovery and detection of changes in glycosylation occupancy in human disease.
Resumo:
Background Impulsivity critically relates to many psychiatric disorders. Given the multifaceted construct that impulsivity represents, defining core aspects of impulsivity is vital for the assessment and understanding of clinical conditions. Choice impulsivity (CI), involving the preferential selection of smaller sooner rewards over larger later rewards, represents one important type of impulsivity. Method The International Society for Research on Impulsivity (InSRI) convened to discuss the definition and assessment of CI and provide recommendations regarding measurement across species. Results Commonly used preclinical and clinical CI behavioral tasks are described, and considerations for each task are provided to guide CI task selection. Differences in assessment of CI (self-report, behavioral) and calculating CI indices (e.g., area-under-the-curve, indifference point, steepness of discounting curve) are discussed along with properties of specific behavioral tasks used in preclinical and clinical settings. Conclusions The InSRI group recommends inclusion of measures of CI in human studies examining impulsivity. Animal studies examining impulsivity should also include assessments of CI and these measures should be harmonized in accordance with human studies of the disorders being modeled in the preclinical investigations. The choice of specific CI measures to be included should be based on the goals of the study and existing preclinical and clinical literature using established CI measures.
Resumo:
The along-track stereo images of Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) sensor with 15 m resolution were used to generate Digital Elevation Model (DEM) on an area with low and near Mean Sea Level (MSL) elevation in Johor, Malaysia. The absolute DEM was generated by using the Rational Polynomial Coefficient (RPC) model which was run on ENVI 4.8 software. In order to generate the absolute DEM, 60 Ground Control Pointes (GCPs) with almost vertical accuracy less than 10 meter extracted from topographic map of the study area. The assessment was carried out on uncorrected and corrected DEM by utilizing dozens of Independent Check Points (ICPs). Consequently, the uncorrected DEM showed the RMSEz of ± 26.43 meter which was decreased to the RMSEz of ± 16.49 meter for the corrected DEM after post-processing. Overall, the corrected DEM of ASTER stereo images met the expectations.
Resumo:
This study aims to assess the accuracy of Digital Elevation Model (DEM) which is generated by using Toutin’s model. Thus, Toutin’s model was run by using OrthoEngineSE of PCI Geomatics 10.3.Thealong-track stereoimages of Advanced Spaceborne Thermal Emission and Reflection radiometer (ASTER) sensor with 15 m resolution were used to produce DEM on an area with low and near Mean Sea Level (MSL) elevation in Johor Malaysia. Despite the satisfactory pre-processing results the visual assessment of the DEM generated from Toutin’s model showed that the DEM contained many outliers and incorrect values. The failure of Toutin’s model may mostly be due to the inaccuracy and insufficiency of ASTER ephemeris data for low terrains as well as huge water body in the stereo images.
Resumo:
Purpose: Older adults have increased visual impairment, including refractive blur from presbyopic multifocal spectacle corrections, and are less able to extract visual information from the environment to plan and execute appropriate stepping actions; these factors may collectively contribute to their higher risk of falls. The aim of this study was to examine the effect of refractive blur and target visibility on the stepping accuracy and visuomotor stepping strategies of older adults during a precision stepping task. Methods: Ten healthy, visually normal older adults (mean age 69.4 ± 5.2 years) walked up and down a 20 m indoor corridor stepping onto selected high and low-contrast targets while viewing under three visual conditions: best-corrected vision, +2.00 DS and +3.00 DS blur; the order of blur conditions was randomised between participants. Stepping accuracy and gaze behaviours were recorded using an eyetracker and a secondary hand-held camera. Results: Older adults made significantly more stepping errors with increasing levels of blur, particularly exhibiting under-stepping (stepping more posteriorly) onto the targets (p<0.05), while visuomotor stepping strategies did not significantly alter. Stepping errors were also significantly greater for the low compared to the high contrast targets and differences in visuomotor stepping strategies were found, including increased duration of gaze and increased interval between gaze onset and initiation of the leg swing when stepping onto the low contrast targets. Conclusions: These findings highlight that stepping accuracy is reduced for low visibility targets, and for high levels of refractive blur at levels typically present in multifocal spectacle corrections, despite significant changes in some of the visuomotor stepping strategies. These findings highlight the importance of maximising the contrast of objects in the environment, and may help explain why older adults wearing multifocal spectacle corrections exhibit an increased risk of falling.
Resumo:
BACKGROUND: Adherence to medicines is important in subjects with diabetes, as nonadherence is associated with an increased risk of morbidity and mortality. However, it is not clear whether there is an association between adherence to medicines and glycaemic control, as not all studies have shown this. One of the reasons for this discrepancy may be that, although there is a standard measure of glycaemic control i.e. HbA1c, there is no standard measure of adherence to medicines. Adherence to medicines can be measured either qualitatively by Morisky or non-Morisky methods or quantitatively using the medicines possession ratio (MPR). AIMS OF THE REVIEW: The aims of this literature review are (1) to determine whether there is an association between adherence to anti-diabetes medicines and glycaemic control, and (2) whether any such association is dependent on how adherence is measured. Methods A literature search of Medline, CINAHL and the Internet (Google) was undertaken with search terms; 'diabetes' with 'adherence' (or compliance, concordance, persistence, continuation) with 'HbA1c' (or glycaemic control). RESULTS: Twenty-three studies were included; 10 qualitative and 12 quantitative studies, and one study using both methods. For the qualitative methods measurements of adherence to anti-diabetes medicines (non-Morisky and Morisky), eight out of ten studies show an association with HbA1c. Nine of ten studies using the quantitative MPR, and two studies using MPR for insulin only, have also shown an association between adherence to anti-diabetes medicines and HbA1c. However, the one study that used both Morisky and MPR did not show an association. Three of the four studies that did not show a relationship, did not use a range of HbA1c values in their regression analysis. The other study that did not show a relationship was specifically in a low income population. CONCLUSIONS: Most studies show an association between adherence to anti-diabetes medicines and HbA1c levels, and this seems to be independent of method used to measure adherence. However, to show an association it is necessary to have a range of HbA1c values. Also, the association is not always apparent in low income populations.