774 resultados para Urban heat islands


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local governments struggle to engage time poor and seemingly apathetic citizens, as well as the city’s young digital natives, the digital locals. This project aims at providing a lightweight, technological contribution towards removing the hierarchy between those who build the city and those who use it. We aim to narrow this gap by enhancing people’s experience of physical spaces with digital, civic technologies that are directly accessible within that space. This paper presents the findings of a design trial allowing users to interact with a public screen via their mobile phones. The screen facilitated a feedback platform about a concrete urban planning project by promoting specific questions and encouraging direct, in-situ, real-time responses via SMS and twitter. This new mechanism offers additional benefits for civic participation as it gives voice to residents who otherwise would not be heard. It also promotes a positive attitude towards local governments and gathers information different from more traditional public engagement tools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Public transportation is an environment with great potential for applying innovative ubiquitous computing services to enhance user experiences. This paper provides the underpinning rationale for research that will be looking at how real-time passenger information system deployed by transit authorities can provide a core platform to improve commuters’ user experiences during all stages of their journey. The proposal builds on this platform to inform the design and development of innovative social media, mobile computing and geospatial information applications, with the hope to create fun and meaningful experiences for passengers during their everyday travel. Furthermore, we present the findings of our pilot study that aims to offer a better understanding of passengers’ activities and social interactions during their daily commute.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved scaling analysis and direct numerical simulations are performed for the unsteady natural convection boundary layer adjacent to a downward facing inclined plate with uniform heat flux. The development of the thermal or viscous boundary layers may be classified into three distinct stages: a start-up stage, a transitional stage and a steady stage, which can be clearly identified in the analytical as well as the numerical results. Previous scaling shows that the existing scaling laws of the boundary layer thickness, velocity and steady state time scale for the natural convection flow on a heated plate of uniform heat flux provide a very poor prediction of the Prandtl number dependency of the flow. However, those scalings perform very well with Rayleigh number and aspect ratio dependency. In this study, a modified Prandtl number scaling is developed using a triple layer integral approach for Pr > 1. It is seen that in comparison to the direct numerical simulations, the modified scaling performs considerably better than the previous scaling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a critique of the Water Sensitive Urban Design (WSUD) paradigm by discussing its congruence with an established sustainable design principle called 'whole system design'. It was found that WSUD is congruent with the whole system design approach as a philosophy, but not in practice. Future improvement of WSUD practice may depend on the adoption of a front-loaded, teamwork-based design and planning process that is embedded in the principle of whole system design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cities accumulate and distribute vast sets of digital information. Many decision-making and planning processes in councils, local governments and organisations are based on both real-time and historical data. Until recently, only a small, carefully selected subset of this information has been released to the public – usually for specific purposes (e.g. train timetables, release of planning application through websites to name just a few). This situation is however changing rapidly. Regulatory frameworks, such as the Freedom of Information Legislation in the US, the UK, the European Union and many other countries guarantee public access to data held by the state. One of the results of this legislation and changing attitudes towards open data has been the widespread release of public information as part of recent Government 2.0 initiatives. This includes the creation of public data catalogues such as data.gov.au (U.S.), data.gov.uk (U.K.), data.gov.au (Australia) at federal government levels, and datasf.org (San Francisco) and data.london.gov.uk (London) at municipal levels. The release of this data has opened up the possibility of a wide range of future applications and services which are now the subject of intensified research efforts. Previous research endeavours have explored the creation of specialised tools to aid decision-making by urban citizens, councils and other stakeholders (Calabrese, Kloeckl & Ratti, 2008; Paulos, Honicky & Hooker, 2009). While these initiatives represent an important step towards open data, they too often result in mere collections of data repositories. Proprietary database formats and the lack of an open application programming interface (API) limit the full potential achievable by allowing these data sets to be cross-queried. Our research, presented in this paper, looks beyond the pure release of data. It is concerned with three essential questions: First, how can data from different sources be integrated into a consistent framework and made accessible? Second, how can ordinary citizens be supported in easily composing data from different sources in order to address their specific problems? Third, what are interfaces that make it easy for citizens to interact with data in an urban environment? How can data be accessed and collected?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study demonstrates the possibility of using an absorption chiller to produce chilled water for air conditioning, and at the same time recover the rejected heat producing domestic hot water. The absorption chiller considered for this application has been sized to suit a standard household and uses a solution of ammonia and water running on hot water at a temperature ranging from 80 - 120°C produced by thermal solar panels. The system consists of five main components: generator, rectifier, condenser, evaporator and absorber, and is divided in two sections at two different pressures. The section at higher pressure includes the generator, rectifier and condenser whereas the section at lower pressure includes the evaporator and the absorber. Heat in this type of system is usually rejected to the environment from the condenser, rectifier and absorber through a cooling tower or air cooler exchanger. In this paper we describe how to recover this heat to create domestic hot water by providing a quantitative evaluation of the amount of energy recovered by the proposed system, if used in the Australian region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At first glance the built environments of South Florida and South East Queensland appear very similar, particularly along the highly urbanized coast. However this apparent similarity belies some fundamental differences between the two regions in terms of context and the approach to regulating development. This paper describes some of these key differences, but focuses on two research questions: 1) do these differences affect the built environment; and 2) if so, how does the built form differ? There has been considerable research on how to best measure urban form, particularly as it relates to measuring urban sprawl (Schwarz 2010; Clifton et al. 2008). Some of the key questions identified by this research include: what are the best variables to use?; what scale should be used?; and what time period to use? We will assimilate this research in order to develop a methodology for measuring urban form and apply it to both case study regions. There are several potential outcomes from this research -- one is that the built form between the two regions is quite different; and the second is that it is similar. The first outcome is what might be expected given the differences in context and development regulation. However how might the second outcome be explained – major differences in context and development regulation resulting in minor differences in key measures of urban form? One explanation is that differences in the way development is regulated are not as important in determining the built form as are private market forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traffic generated semi and non volatile organic compounds (SVOCs and NVOCs) pose a serious threat to human and ecosystem health when washed off into receiving water bodies by stormwater. Climate change influenced rainfall characteristics makes the estimation of these pollutants in stormwater quite complex. The research study discussed in the paper developed a prediction framework for such pollutants under the dynamic influence of climate change on rainfall characteristics. It was established through principal component analysis (PCA) that the intensity and durations of low to moderate rain events induced by climate change mainly affect the wash-off of SVOCs and NVOCs from urban roads. The study outcomes were able to overcome the limitations of stringent laboratory preparation of calibration matrices by extracting uncorrelated underlying factors in the data matrices through systematic application of PCA and factor analysis (FA). Based on the initial findings from PCA and FA, the framework incorporated orthogonal rotatable central composite experimental design to set up calibration matrices and partial least square regression to identify significant variables in predicting the target SVOCs and NVOCs in four particulate fractions ranging from >300-1 μm and one dissolved fraction of <1 μm. For the particulate fractions range >300-1 μm, similar distributions of predicted and observed concentrations of the target compounds from minimum to 75th percentile were achieved. The inter-event coefficient of variations for particulate fractions of >300-1 μm were 5% to 25%. The limited solubility of the target compounds in stormwater restricted the predictive capacity of the proposed method for the dissolved fraction of <1 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent times, light gauge steel framed (LSF) structures, such as cold-formed steel wall systems, are increasingly used, but without a full understanding of their fire performance. Traditionally the fire resistance rating of these load-bearing LSF wall systems is based on approximate prescriptive methods developed based on limited fire tests. Very often they are limited to standard wall configurations used by the industry. Increased fire rating is provided simply by adding more plasterboards to these walls. This is not an acceptable situation as it not only inhibits innovation and structural and cost efficiencies but also casts doubt over the fire safety of these wall systems. Hence a detailed fire research study into the performance of LSF wall systems was undertaken using full scale fire tests and extensive numerical studies. A new composite wall panel developed at QUT was also considered in this study, where the insulation was used externally between the plasterboards on both sides of the steel wall frame instead of locating it in the cavity. Three full scale fire tests of LSF wall systems built using the new composite panel system were undertaken at a higher load ratio using a gas furnace designed to deliver heat in accordance with the standard time temperature curve in AS 1530.4 (SA, 2005). Fire tests included the measurements of load-deformation characteristics of LSF walls until failure as well as associated time-temperature measurements across the thickness and along the length of all the specimens. Tests of LSF walls under axial compression load have shown the improvement to their fire performance and fire resistance rating when the new composite panel was used. Hence this research recommends the use of the new composite panel system for cold-formed LSF walls. The numerical study was undertaken using a finite element program ABAQUS. The finite element analyses were conducted under both steady state and transient state conditions using the measured hot and cold flange temperature distributions from the fire tests. The elevated temperature reduction factors for mechanical properties were based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). These finite element models were first validated by comparing their results with experimental test results from this study and Kolarkar (2010). The developed finite element models were able to predict the failure times within 5 minutes. The validated model was then used in a detailed numerical study into the strength of cold-formed thin-walled steel channels used in both the conventional and the new composite panel systems to increase the understanding of their behaviour under nonuniform elevated temperature conditions and to develop fire design rules. The measured time-temperature distributions obtained from the fire tests were used. Since the fire tests showed that the plasterboards provided sufficient lateral restraint until the failure of LSF wall panels, this assumption was also used in the analyses and was further validated by comparison with experimental results. Hence in this study of LSF wall studs, only the flexural buckling about the major axis and local buckling were considered. A new fire design method was proposed using AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The importance of considering thermal bowing, magnified thermal bowing and neutral axis shift in the fire design was also investigated. A spread sheet based design tool was developed based on the above design codes to predict the failure load ratio versus time and temperature for varying LSF wall configurations including insulations. Idealised time-temperature profiles were developed based on the measured temperature values of the studs. This was used in a detailed numerical study to fully understand the structural behaviour of LSF wall panels. Appropriate equations were proposed to find the critical temperatures for different composite panels, varying in steel thickness, steel grade and screw spacing for any load ratio. Hence useful and simple design rules were proposed based on the current cold-formed steel structures and fire design standards, and their accuracy and advantages were discussed. The results were also used to validate the fire design rules developed based on AS/NZS 4600 (SA, 2005) and Eurocode Part 1.3 (ECS, 2006). This demonstrated the significant improvements to the design method when compared to the currently used prescriptive design methods for LSF wall systems under fire conditions. In summary, this research has developed comprehensive experimental and numerical thermal and structural performance data for both the conventional and the proposed new load bearing LSF wall systems under standard fire conditions. Finite element models were developed to predict the failure times of LSF walls accurately. Idealized hot flange temperature profiles were developed for non-insulated, cavity and externally insulated load bearing wall systems. Suitable fire design rules and spread sheet based design tools were developed based on the existing standards to predict the ultimate failure load, failure times and failure temperatures of LSF wall studs. Simplified equations were proposed to find the critical temperatures for varying wall panel configurations and load ratios. The results from this research are useful to both structural and fire engineers and researchers. Most importantly, this research has significantly improved the knowledge and understanding of cold-formed LSF loadbearing walls under standard fire conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The body of the article concerns itself with the vulnerability of islands and focuses on the Galapagos Archipelago where the author spent three years studying flamingoes and flightless cormorants.The article suggests practical, simple behavioural changes that individuals might adopt to help increase biodiversity and extend natural corridors and islands of vegetation throughout cities and suburbs. It will ask some questions about human motives for behaviour change and moral decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire safety of buildings has been recognised as very important by the building industry and the community at large. Gypsum plasterboards are widely used to protect light gauge steel frame (LSF) walls all over the world. Gypsum contains free and chemically bound water in its crystal structure. Plasterboard also contains gypsum (CaSO4.2H2O) and calcium carbonate (CaCO3). The dehydration of gypsum and the decomposition of calcium carbonate absorb heat, and thus are able to protect LSF walls from fires. Kolarkar and Mahendran (2008) developed an innovative composite wall panel system, where the insulation was sandwiched between two plasterboards to improve the thermal and structural performance of LSF wall panels under fire conditions. In order to understand the performance of gypsum plasterboards and LSF wall panels under standard fire conditions, many experiments were conducted in the Fire Research Laboratory of Queensland University of Technology (Kolarkar, 2010). Fire tests were conducted on single, double and triple layers of Type X gypsum plasterboards and load bearing LSF wall panels under standard fire conditions. However, suitable numerical models have not been developed to investigate the thermal performance of LSF walls using the innovative composite panels under standard fire conditions. Continued reliance on expensive and time consuming fire tests is not acceptable. Therefore this research developed suitable numerical models to investigate the thermal performance of both plasterboard assemblies and load bearing LSF wall panels. SAFIR, a finite element program, was used to investigate the thermal performance of gypsum plasterboard assemblies and LSF wall panels under standard fire conditions. Appropriate values of important thermal properties were proposed for plasterboards and insulations based on laboratory tests, literature review and comparisons of finite element analysis results of small scale plasterboard assemblies from this research and corresponding experimental results from Kolarkar (2010). The important thermal properties (thermal conductivity, specific heat capacity and density) of gypsum plasterboard and insulation materials were proposed as functions of temperature and used in the numerical models of load bearing LSF wall panels. Using these thermal properties, the developed finite element models were able to accurately predict the time temperature profiles of plasterboard assemblies while they predicted them reasonably well for load bearing LSF wall systems despite the many complexities that are present in these LSF wall systems under fires. This thesis presents the details of the finite element models of plasterboard assemblies and load bearing LSF wall panels including those with the composite panels developed by Kolarkar and Mahendran (2008). It examines and compares the thermal performance of composite panels developed based on different insulating materials of varying densities and thicknesses based on 11 small scale tests, and makes suitable recommendations for improved fire performance of stud wall panels protected by these composite panels. It also presents the thermal performance data of LSF wall systems and demonstrates the superior performance of LSF wall systems using the composite panels. Using the developed finite element of models of LSF walls, this thesis has proposed new LSF wall systems with increased fire rating. The developed finite element models are particularly useful in comparing the thermal performance of different wall panel systems without time consuming and expensive fire tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Driver response (reaction) time (tr) of the second queuing vehicle is generally longer than other vehicles at signalized intersections. Though this phenomenon was revealed in 1972, the above factor is still ignored in conventional departure models. This paper highlights the need for quantitative measurements and analysis of queuing vehicle performance in spontaneous discharge pattern because it can improve microsimulation. Video recording from major cities in Australia plus twenty two sets of vehicle trajectories extracted from the Next Generation Simulation (NGSIM) Peachtree Street Dataset have been analyzed to better understand queuing vehicle performance in the discharge process. Findings from this research will alleviate driver response time and also can be used for the calibration of the microscopic traffic simulation model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solids are widely identified as a carrier of harmful pollutants in stormwater runoff exerting a significant risk to receiving waters. This paper outlines the findings of an in-depth investigation on heavy metal adsorption to solids surfaces. Pollutant build-up samples collected from sixteen road sites in residential, industrial and commercial land uses were separated into four particle size ranges and analysed for a range of physico-chemical parameters and nine heavy metals including Iron (Fe), Aluminum (Al), Lead (Pb), Zinc (Zn), Cadmium (Cd), Chromium (Cr), Manganese (Mn), Nickel (Ni) and Copper (Cu). High specific surface area (SSA) and total organic carbon (TOC) content in finer particle size ranges was noted, thus confirming strong correlations with heavy metals. Based on their physico-chemical characteristics, two different types of solids originating from traffic and soil sources were identified. Solids generated by traffic were associated with high loads of heavy metals such as Cd and Cr with strong correlation with SSA. This suggested the existence of surface dependent bonds such as cation exchange between heavy metals and solids. In contrast, Fe, Al and Mn which can be attributed to soil inputs showed strong correlation with TOC suggesting strong bonds such as chemsorption. Zn was found to be primarily attached to solids by bonding with the oxides of Fe, Al and Mn. The data analysis also confirmed the predominance of the finer fraction, with 70% of the solids being finer than 150 µm and containing 60% of the heavy metal pollutant load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Does heat have a cooling effect on culture? Sweat argues the reverse: culture thrives in the subtropical zones. While acknowledging that the subtropical generates ambivalence—being cast as alternately idyllic or hellish—Sweat nonetheless seeks to develop the specific voices of subtropical cultures. The uneasy place of this sweaty discourse is explored across art, literature, architecture, and the built environment. In particular, Sweat focuses on the most commonly experienced situation, the everyday house. While it addresses subjects from Japan, Brazil, and France, Sweat centres on Brisbane, Queensland—long in the shadow of Sydney and Melbourne in the Australian cultural psyche—due to its enduring and self-conscious attention to subtropical living.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the benefits and issues related to travel time prediction on urban network. Travel time information quantifies congestion and is perhaps the most important network performance measure. Travel time prediction has been an active area of research for the last five decades. The activities related to ITS have increased the attention of researchers for better and accurate real-time prediction of travel time. Majority of the literature on travel time prediction is applicable to freeways where, under non-incident conditions, traffic flow is not affected by external factors such as traffic control signals and opposing traffic flows. On urban environment the problem is more complicated due to conflicting areas (intersections), mid-link sources and sinks etc. and needs to be addressed.