20 resultados para Gun-carriages.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

It’s commonly assumed that psychiatric violence is motivated by delusions, but here the concept of a reversed impetus is explored, to understand whether delusions are formed as ad-hoc or post-hoc rationalizations of behaviour or in advance of the actus reus. The reflexive violence model proposes that perceptual stimuli has motivational power and this may trigger unwanted actions and hallucinations. The model is based on the theory of ecological perception, where opportunities enabled by an object are cues to act. As an apple triggers a desire to eat, a gun triggers a desire to shoot. These affordances (as they are called) are part of the perceptual apparatus, they allow the direct recognition of objects – and in emergencies they enable the fastest possible reactions. Even under normal circumstances, the presence of a weapon will trigger inhibited violent impulses. The presence of a victim will also, but under normal circumstances, these affordances don’t become violent because negative action impulses are totally inhibited, whereas in psychotic illness, negative action impulses are treated as emergencies and bypass frontal inhibitory circuits. What would have been object recognition becomes a blind automatic action. A range of mental illnesses can cause inhibition to be bypassed. At its most innocuous, this causes both simple hallucinations (where the motivational power of an object is misattributed). But ecological perception may have the power to trigger serious violence also –a kind that’s devoid of motives or planning and is often shrouded in amnesia or post-rational delusions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Field emission (FE) electron gun sources provide new capabilities for high lateral resolution EPMA. The determination of analytical lateral resolution is not as straightforward as that for electron microscopy imaging. Results from two sets of experiments to determine the actual lateral resolution for accurate EPMA are presented for Kα X-ray lines of Si and Al and Lα of Fe at 5 and 7 keV in a silicate glass. These results are compared to theoretical predictions and Monte Carlo simulations of analytical lateral resolution. The experiments suggest little is gained in lateral resolution by dropping from 7 to 5 keV in EPMA of this silicate glass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare pressures generated by 2 different cement pressurisers at various locations in the proximal femur. METHODS: Two groups of 5 synthetic femurs were used, and 6 pressure sensors were placed in the femur at 20-mm intervals proximally to distally. Cement was filled into the femoral canal retrogradely using a cement gun with either the half-moon pressuriser or the femoral canal pressuriser. Maximum pressures and pressure time integrals (cumulative pressure over time) of the 2 pressurisers were compared. RESULTS: At all sensors, the half-moon pressuriser produced higher maximum pressures and pressure time integrals than the femoral canal pressuriser, but the difference was significant only at sensor 1 (proximal femur). This may result in reduced cement interdigitation in the proximal femur. CONCLUSION: The half-moon pressuriser produced higher maximum cementation pressures and pressure time integrals than the femoral canal pressuriser in the proximal femur region, which is critical for rotational stability of the implant and prevention of implant fracture. KEYWORDS: arthroplasty, replacement, hip; bone cements; femur

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article we present the morphological and magnetic characterization of ferrofluid-impregnated biomimetic scaffolds made of hydroxyapatite and collagen used for bone reconstruction. We describe an innovative and simple impregnation process by which the ferrofluid is firmly adsorbed onto the hydroxyapatite/collagen scaffolds. The process confers sufficient magnetization to attract potential magnetic carriers, which may be used to transport bioactive agents that favour bone regeneration. The crystalline structure of the magnetite contained in the ferrofluid is preserved and its quantity, estimated from the weight gain due to the impregnation process, is consistent with that obtained from energy dispersive X-ray spectroscopy. The magnetization, measured with a superconducting quantum interference device, is uniform throughout the scaffolds, demonstrating the efficiency of the impregnation process. The field emission gun scanning electron microscopy characterization demonstrates that the process does not alter the morphology of the hydroxyapatite/collagen scaffolds, which is essential for the preservation of their bioactivity and consequently for their effectiveness in promoting bone formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Additive manufacturing or ‘3D printing’ has emerged into the mainstream in the last few years, with much hype about its revolutionary potential as the latest ‘disruptive technology’ to destroy existing business models, empower individuals and evade any kind of government control. This book examines the trajectory of 3D printing in practice and how it interacts with various areas of law, including intellectual property, product liability, gun laws, data privacy and fundamental/constitutional rights. A particular comparison is made between 3D printing and the Internet as this has been, legally-speaking, another ‘disruptive technology’ and also one on which 3D printing is partially dependent. This book is the first expert analysis of 3D printing from a legal perspective and provides a critical assessment of the extent to which existing legal regimes can be successfully applied to, and enforced vis-à-vis, 3D printing.