397 resultados para Rudy, Gerard


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wide-Area Measurement Systems (WAMS) provide the opportunity of utilizing remote signals from different locations for the enhancement of power system stability. This paper focuses on the implementation of remote measurements as supplementary signals for off-center Static Var Compensators (SVCs) to damp inter-area oscillations. Combination of participation factor and residue method is used for the selection of most effective stabilizing signal. Speed difference of two generators from separate areas is identified as the best stabilizing signal and used as a supplementary signal for lead-lag controller of SVCs. Time delays of remote measurements and control signals is considered. Wide-Area Damping Controller (WADC) is deployed in Matlab Simulink framework and is tested under different operating conditions. Simulation results reveal that the proposed WADC improve the dynamic characteristic of the system significantly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a new controller for the excitation system to improve rotor angle stability. The proposed controller uses energy function to predict desired flux for the generator to achieve improved first swing stability and enhanced system damping. The controller is designed through predicting the desired value of flux for the future step of the system and then obtaining appropriate supplementary control input for the excitation system. The simulations are performed on Single-Machine-Infinite-Bus system and the results verify the efficiency of the controller. The proposed method facilitates the excitation system with a feasible and reliable controller for severe disturbances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study identified the key self-regulated learning (SRL) strategies and their sources for nine school-aged adolescent males aged 15 to 17 years. The Self-Regulated Learning Interview Schedule (SRLIS) was used along with semi-structured interviews with the participants and their parents to elicit information on SRL strategies and contexts for the formation of self-regulatory habits. Early habit-forming experiences of the family home in relation to homework and study routines were found to form an important base for effective SRL. Teachers were identified as the most common source of SRL strategies with important formative experiences occurring during the first two years of high school.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Dementia and delirium appear to be common among older patients admitted to acute hospitals, although there are few Australian data regarding these important conditions. Aim: The aim of this study was to determine the prevalence and incidence of dementia and delirium among older patients admitted to acute hospitals in Queensland and to profile these patients. Method: Prospective observational cohort study (n = 493) of patients aged 70 years and older admitted to general medical, general surgical and orthopaedic wards of four acute hospitals in Queensland between 2008 and 2010. Trained research nurses completed comprehensive geriatric assessments and obtained detailed information about each patient’s physical, cognitive and psychosocial functioning using the interRAI Acute Care and other standardised instruments. Nurses also visited patients daily to identify incident delirium. Two physicians independently reviewed patients’ medical records and assessments to establish the diagnosis of dementia and/or delirium. Results: Overall, 29.4% of patients (n = 145) were considered to have cognitive impairment, including 102 (20.7% of the total) who were considered to have dementia. This rate increased to 47.4% in the oldest patients (aged 90 years). The overall prevalence of delirium at admission was 9.7% (23.5% in patients with dementia), and the rate of incident delirium was 7.6% (14.7% in patients with dementia). Conclusion: The prevalence of dementia and delirium among older patients admitted to acute hospitals is high and is likely to increase with population aging. It is suggested that hospital design, staffing and processes should be attuned better to meet these patients’ needs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To compare the diagnostic accuracy of the interRAI Acute Care (AC) Cognitive Performance Scale (CPS2) and the Mini-Mental State Examination (MMSE), against independent clinical diagnosis for detecting dementia in older hospitalized patients. Design, Setting, and Participants The study was part of a prospective observational cohort study of patients aged ≥70 years admitted to four acute hospitals in Queensland, Australia, between 2008 and 2010. Recruitment was consecutive and patients expected to remain in hospital for ≥48 hours were eligible to participate. Data for 462 patients were available for this study. Measurements Trained research nurses completed comprehensive geriatric assessments and administered the interRAI AC and MMSE to patients. Two physicians independently reviewed patients’ medical records and assessments to establish the diagnosis of dementia. Indicators of diagnostic accuracy included sensitivity, specificity, predictive values, likelihood ratios and areas under receiver (AUC) operating characteristic curves. Results 85 patients (18.4%) were considered to have dementia according to independent clinical diagnosis. The sensitivity of the CPS2 [0.68 (95%CI: 0.58–0.77)] was not statistically different to the MMSE [0.75 (0.64–0.83)] in predicting physician diagnosed dementia. The AUCs for the 2 instruments were also not statistically different: CPS2 AUC = 0.83 (95%CI: 0.78–0.89) and MMSE AUC = 0.87 (95%CI: 0.83–0.91), while the CPS2 demonstrated higher specificity [0.92 95%CI: 0.89–0.95)] than the MMSE [0.82 (0.77–0.85)]. Agreement between the CPS2 and clinical diagnosis was substantial (87.4%; κ=0.61). Conclusion The CPS2 appears to be a reliable screening tool for assessing cognitive impairment in acutely unwell older hospitalized patients. These findings add to the growing body of evidence supporting the utility of the interRAI AC, within which the CPS2 is embedded. The interRAI AC offers the advantage of being able to accurately screen for both dementia and delirium without the need to use additional assessments, thus increasing assessment efficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim Few Australian studies have examined the impact of dementia on hospital outcomes. The aim of this study was to determine the relative contribution of dementia to adverse outcomes in older hospital patients. Method Prospective observational cohort study (n = 493) of patients aged ≥70 years admitted to four acute hospitals in Queensland. Trained research nurses completed comprehensive geriatric assessments using standardised instruments and collected data regarding adverse outcomes. The diagnosis of dementia was established by independent physician review of patients' medical records and assessments. Results Patients with dementia (n = 102, 20.7%) were significantly older (P = 0.01), had poorer functional ability (P < 0.01), and were more likely to have delirium at admission (P < 0.01) than patients without dementia. Dementia (odds ratio = 4.8, P < 0.001) increased the risk of developing delirium during the hospital stay. Conclusion Older patients with dementia are more impaired and vulnerable than patients without dementia and are at greater risk of adverse outcomes when hospitalised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Australia is in the process of making the most important change to its health care system since the implementation of Medicare.1 We agree with Cameron and Cooke that there are important lessons for Australia from the implementation of the 4-hour rule in the United Kingdom. As in Robert Zemeckis’s 1985 movie classic, Back to the future, the old question of “If I had the opportunity to do something again, what would I have done differently?” applies. We challenge the assumption that Australia is embarking on something that the UK has recently abandoned. The UK has not actually abandoned the 4-hour rule but expanded it into a suite of eight indicators that include three time-based measures, including total time in the emergency department (ED).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter gives an overview of the smartphone app economy and its various constituent ecosystems. It examines the role of the app store model and the proliferation of mobile apps in the shift from value chains controlled by network operators and handset manufacturers, to value networks – or ecosystems – focused around operating systems and apps. It outlines some of the benefits and disadvantages for developers of the app store model for remuneration and distribution. The chapter concludes with a discussion of recent research on the size and employment effects of the app economy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a large interconnected power system, disturbances initiated by a fault or other events cause acceleration in the generator rotors with respect to their synchronous reference frame. This acceleration of rotors can be described by two different dynamic phenomena, as shown in existing literature. One of the phenomena is simultaneous acceleration and the other is electromechanical wave propagation, which is characterized by travelling waves in terms of a wave equation. This paper demonstrates that depending on the structure of the system, the exhibited dynamic response will be dominated by one phenomenon or the other or a mixture of both. Two system structures of choice are examined, with each structure exemplifying each phenomenon present to different degrees in their dynamic responses. Prediction of dominance of either dynamic phenomenon in a particular system can be determined by taking into account the relative sizes of the values of its reduced admittance matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a series of operating schedules for Battery Energy Storage Companies (BESC) to provide peak shaving and spinning reserve services in the electricity markets under increasing wind penetration. As individual market participants, BESC can bid in ancillary services markets in an Independent System Operator (ISO) and contribute towards frequency and voltage support in the grid. Recent development in batteries technologies and availability of the day-ahead spot market prices would make BESC economically feasible. Profit maximization of BESC is achieved by determining the optimum capacity of Energy Storage Systems (ESS) required for meeting spinning reserve requirements as well as peak shaving. Historic spot market prices and frequency deviations from Australia Energy Market Operator (AEMO) are used for numerical simulations and the economic benefits of BESC is considered reflecting various aspects in Australia’s National Electricity Markets (NEM).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Price based technique is one way to handle increase in peak demand and deal with voltage violations in residential distribution systems. This paper proposes an improved real time pricing scheme for residential customers with demand response option. Smart meters and in-home display units are used to broadcast the price and appropriate load adjustment signals. Customers are given an opportunity to respond to the signals and adjust the loads. This scheme helps distribution companies to deal with overloading problems and voltage issues in a more efficient way. Also, variations in wholesale electricity prices are passed on to electricity customers to take collective measure to reduce network peak demand. It is ensured that both customers and utility are benefitted by this scheme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integration of small-scale electricity generators, known as Distributed Generation (DG), into the distribution networks has become increasingly popular at the present. This tendency together with the falling price of synchronous-type generator has potential to give the DG a better chance in participating in the voltage regulation process together with other devices already available in the system. The voltage control issue turns out to be a very challenging problem for the distribution engineers since existing control coordination schemes would need to be reconsidered to take into account the DG operation. In this paper, we propose a control coordination technique, which is able to utilize the ability of the DG as a voltage regulator, and at the same time minimizes interaction with other active devices, such as On-load Tap Changing Transformer (OLTC) and voltage regulator. The technique has been developed based on the concept of control zone, Line Drop Compensation (LDC), as well as the choice of controller's parameters. Simulations carried out on an Australian system show that the technique is suitable and flexible for any system with multiple regulating devices including DG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reliable operation of distribution systems is critically dependent on detailed understanding of load impacts on distribution transformer insulation systems. This paper estimates the impact of rooftop photovoltaic (PV) generation on a typical 200-kVA, 22/0.415-kV distribution transformer life under different operating conditions. This transformer supplies a suburban area with a high penetration of roof top photovoltaic systems. The transformer loads and the phase distribution of the PV systems are significantly unbalanced. Oil and hot-spot temperature and remnant life of distribution transformer under different PV and balance scenarios are calculated. It is shown that PV can significantly extend the transformer life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new approach is proposed for obtaining a non-linear area-based equivalent model of power systems to express the inter-area oscillations using synchronised phasor measurements. The generators that remain coherent for inter-area disturbances over a wide range of operating conditions define the areas, and the reduced model is obtained by representing each area by an equivalent machine. The parameters of the reduced system are identified by processing the obtained measurements, and a non-linear Kalman estimator is then designed for the estimation of equivalent area angles and frequencies. The simulation of the approach on a two-area system shows substantial reduction of non-inter-area modes in the estimated angles. The proposed methods are also applied to a ten-machine system to illustrate the feasibility of the approach on larger and meshed networks.