351 resultados para provocative cardiac testing
Resumo:
The purpose of this investigation is to present an overview of roadside drug driving enforcement and detections in Queensland, Australia since the introduction of oral fluid screening. Drug driving is a problematic issue for road safety and investigations of the prevalence and impact of drug driving suggest that, in particular, the use of illicit drugs may increase a driver’s involvement in a road crash when compared to a driver who is drug free. In response to the potential increased crash involvement of drug impaired drivers, Australian police agencies have adopted the use of oral fluid analysis to detect the presence of illicit drugs in drivers. This paper describes the results of roadside drug testing for over 80,000 drivers in Queensland, Australia, from December 2007 to June 2012. It provides unique data on the prevalence of methamphetamine, cannabis and ecstasy in the screened population for the period. When prevalence rates are examined over time, drug driving detection rates have almost doubled from around 2.0% at the introduction of roadside testing operations to just under 4.0% in the latter years. The most common drug type detected was methamphetamine (40.8%) followed by cannabis (29.8%) and methamphetamine/cannabis combination (22.5%). By comparison, the rate of ecstasy detection was very low (1.7%). The data revealed a number of regional, age and gender patterns and variations of drug driving across the state. Younger drivers were more likely to test positive for cannabis whilst older drivers were more likely to test positive for methamphetamine. The overall characteristics of drivers who tested positive to the presence of at least one of the target illicit drugs are they are likely to be male, aged 30-39 years, be driving a car on Friday, Saturday or Sunday between 6:00PM and 6:00AM and to test positive for methamphetamine.
Resumo:
An extended theory of planned behavior (TPB) was used to understand the factors, particularly control perceptions and affective reactions, given conflicting findings in previous research, informing younger people's intentions to join a bone marrow registry. Participants (N = 174) completed attitude, subjective norm, perceived behavioral control (PBC), moral norm, anticipated regret, self-identity, and intention items for registering. The extended TPB (except PBC) explained 67.2% of variance in intention. Further testing is needed as to the volitional nature of registering. Moral norm, anticipated regret, and self-identity are likely intervention targets for increasing younger people's bone marrow registry participation.
Resumo:
Introduction: Ondansetron is a 5-HT3 receptor antagonist commonly used as an anti-emetic to prevent the nausea and vomiting associated with anti-cancer drugs, cancer radiotherapy, or postoperatively. Recently, the US Food and Drug Administration (FDA) issued a warning for ondansetron due to a potential for prolongation of the QT interval of the electrocardiogram (ECG), a phenomenon that is associated with an increased risk of the potentially fatal arrhythmia torsade de pointes. Areas covered: We undertook a review of the cardiac safety of ondansetron. Our primary sources of information were PubMed (with downloading of full articles), and the internet. Expert opinion: The dose of ondansetron that the FDA has concerns about is 32 mg iv (or several doses that are equivalent to this), which is only used in preventing nausea and vomiting associated with cancer chemotherapy. This suggests that ondansetron may be safe in the lower doses used to prevent the nausea and vomiting in radiation treatment or postoperatively. However, as there is a report that a lower dose of ondansetron prolonged the QT interval in healthy volunteers, this needs to be clarified by the FDA. More research needs to be undertaken of the relationship between QT prolongation and torsades in order that the FDA can produce clear-cut evidence of pro-arrhythmic risk when introducing warnings for this.
Resumo:
Introduction: Domperidone is a dopamine D2-receptor antagonist developed as an antiemetic and prokinetic agents. Oral domperidone is not approved in the US, but is used in many countries to treat nausea and vomiting, gastroparesis, and as a galactogogue (to promote lactation). The US Food and Drug Administration (FDA) have issued a warning about the cardiac safety of domperidone. Areas covered: The authors undertook a review of the cardiac safety of oral domperidone. Expert opinion: The data from preclinical studies are unambiguous in identifying domperidone as able to produce marked hERG channel inhibition and action potential prolongation at clinically relevant concentrations. The compound’s propensity to augment instability of action potential duration and action potential triangulation are also indicative of proarrhythmic potential. Domperidone should not be administered to subjects with pre-existing QT prolongation/LQTS, subjects receiving drugs that inhibit CYP3A4, subjects with electrolyte abnormalities or with other risk factors for QT-prolongation. With these provisos, it is possible that domperidone may be used as a galactogogue without direct risk to healthy breast feeding women but more safety information should be sought in this situation. Also, more safety information is required regarding risk to breast feeding infants or before domperidone is routinely used in gastroparesis or gastroesphageal reflux in children.
Resumo:
This paper describes a generic and integrated solar powered remote Unmanned Air Vehicles (UAV) and Wireless Sensor Network (WSN) gas sensing system. The system uses a generic gas sensing system for CH4 and CO2 concentrations using metal oxide (MoX) and non-dispersive infrared sensors, and a new solar cell encapsulation method to power the UASs as well as a data management platform to store, analyse and share the information with operators and external users. The system was successfully field tested at ground and low altitudes, collecting, storing and transmitting data in real time to a central node for analysis and 3D mapping. The system can be used in a wide range of outdoor applications, especially in agriculture, bushfires, mining studies, opening the way to a ubiquitous low cost environmental monitoring. A video of the bench and flight test performed can be seen in the following link https://www.youtube.com/watch?v=Bwas7stYIxQ.
Resumo:
Cyclostationary models for the diagnostic signals measured on faulty rotating machineries have proved to be successful in many laboratory tests and industrial applications. The squared envelope spectrum has been pointed out as the most efficient indicator for the assessment of second order cyclostationary symptoms of damages, which are typical, for instance, of rolling element bearing faults. In an attempt to foster the spread of rotating machinery diagnostics, the current trend in the field is to reach higher levels of automation of the condition monitoring systems. For this purpose, statistical tests for the presence of cyclostationarity have been proposed during the last years. The statistical thresholds proposed in the past for the identification of cyclostationary components have been obtained under the hypothesis of having a white noise signal when the component is healthy. This need, coupled with the non-white nature of the real signals implies the necessity of pre-whitening or filtering the signal in optimal narrow-bands, increasing the complexity of the algorithm and the risk of losing diagnostic information or introducing biases on the result. In this paper, the authors introduce an original analytical derivation of the statistical tests for cyclostationarity in the squared envelope spectrum, dropping the hypothesis of white noise from the beginning. The effect of first order and second order cyclostationary components on the distribution of the squared envelope spectrum will be quantified and the effectiveness of the newly proposed threshold verified, providing a sound theoretical basis and a practical starting point for efficient automated diagnostics of machine components such as rolling element bearings. The analytical results will be verified by means of numerical simulations and by using experimental vibration data of rolling element bearings.
Resumo:
The objective of this study was to test for the measurement invariance of the Attention and Thought Problems subscales of the Child Behavior Checklist (CBCL) and Youth Self-Report (YSR) in a population-based sample of adolescents with and without epilepsy. Data were obtained from the 14-year follow-up of the Mater University Study of Pregnancy in which 33 adolescents with epilepsy and 1068 healthy controls were included for analysis. Confirmatory factor analysis was used to test for measurement invariance between adolescents with and without epilepsy. Structural equation modeling was used to test for group differences in attention and thought problems as measured with the CBCL and YSR. Measurement invariance was demonstrated for the original CBCL Attention Problems and YSR Thought Problems. After the removal of ambiguous items (“confused” and “daydreams”),measurement invariance was established for the YSR Attention Problems. The original and reduced CBCL Thought Problems were noninvariant. Adolescents with epilepsy had significantly more symptoms of behavioral problems on the CBCL Attention Problems, β = 0.51, p = 0.002, compared with healthy controls. In contrast, no significant differences were found for the YSR Attention and Thought Problems, β = −0.11, p = 0.417 and β = −0.20, p = 0.116, respectively. In this population-based sample of adolescents with epilepsy, the CBCL Attention Problems and YSR Thought Problems appear to be valid measures of behavioral problems, whereas the YSR Attention Problems was valid only after the removal of ambiguous items. Replication of these findings in clinical samples of adolescents with epilepsy that overcome the limitations of the current study is warranted.
Resumo:
We have developed a method to test the cytotoxicity of wound dressings, ointments, creams and gels used in our Burn Centre, by placing them on a permeable Nunc Polycarbonate cell culture insert, incubated with a monolayer of cells (HaCaTs and primary human keratinocytes). METHODS: We performed two different methods to determine the relative toxicity to cells. (1) Photo visualisation: The dressings or compounds were positioned on the insert's membrane which was placed onto the monolayer tissue culture plate. After 24 h the surviving adherent cells were stained with Toluidine Blue and photos of the plates were taken. The acellular area of non-adherent dead cells which had been washed off with buffer was measured as a percentage of the total area of the plate. (2) Cell count of surviving cells: After 24 h incubation with the test material, the remaining cells were detached with trypsin, spun down and counted in a Haemocytometer with Trypan Blue, which differentiates between live and dead cells. RESULTS: Seventeen products were tested. The least cytotoxic products were Melolite, White soft Paraffin and Chlorsig1% Ointment. Some cytotoxicity was shown with Jelonet, Mepitel((R)), PolyMem((R)), DuoDerm((R)) and Xeroform. The most cytotoxic products included those which contained silver or Chlorhexidine and Paraffin Cream a moisturizer which contains the preservative Chlorocresol. CONCLUSION: This in vitro cell culture insert method allows testing of agents without direct cell contact. It is easy and quick to perform, and should help the clinician to determine the relative cytotoxicity of various dressings and the optimal dressing for each individual wound.
Resumo:
Background and Purpose The β1-adrenoceptor has at least two binding sites, high and low affinity sites (β1H and β1L, respectively), which mediate cardiostimulation. While β1H-adrenoceptor can be blocked by all clinically used β-blockers, β1L-adrenoceptor is relatively resistant to blockade. Thus, chronic β1L-adrenoceptor activation may mediate persistent cardiostimulation, despite the concurrent blockade of β1H-adrenoceptors. Hence, it is important to determine the potential significance of β1L-adrenoceptors in vivo, particularly in pathological situations. Experimental Approach C57Bl/6 male mice were used. Chronic (4 or 8 weeks) β1L-adrenoceptor activation was achieved by treatment, via osmotic mini pumps, with (-)-CGP12177 (10 mg·kg−1·day−1). Cardiac function was assessed by echocardiography and micromanometry. Key Results (-)-CGP12177 treatment of healthy mice increased heart rate and left ventricular (LV) contractility. (-)-CGP12177 treatment of mice subjected to transverse aorta constriction (TAC), during weeks 4–8 or 4–12 after TAC, led to a positive inotropic effect and exacerbated fibrogenic signalling while cardiac hypertrophy tended to be more severe. (-)-CGP12177 treatment of mice with TAC also exacerbated the myocardial expression of hypertrophic, fibrogenic and inflammatory genes compared to untreated TAC mice. Washout of (-)-CGP12177 revealed a more pronounced cardiac dysfunction after 12 weeks of TAC. Conclusions and Implications β1L-adrenoceptor activation provides functional support to the heart, in both normal and pathological (pressure overload) situations. Sustained β1L-adrenoceptor activation in the diseased heart exacerbates LV remodelling and therefore may promote disease progression from compensatory hypertrophy to heart failure.
Resumo:
Background Drink driving among women is a growing problem in many motorised countries. While research has shown that male and female drink drivers differ on a number of characteristics, few studies have addressed the circumstances surrounding women’s drink driving offences specifically. Aim To add to previous research by comparing apprehension characteristics among men and women and to extend the understanding of the female drink driving problem by investigating the drink driving characteristics that are unique to women. Results The sample consisted of the 248,173 (21.5% women) drink drivers apprehended between 2000 and 2011 in Queensland, Australia. Gender comparisons showed that women were older, had lower levels of reoffending, and were more likely to be apprehended in Major Cities compared to men. Comparisons of age group and reoffending and non-reoffending among female drink drivers only revealed that higher BAC readings were more common among younger women. Moreover, a substantial minority (13.7%) of women aged 24 years or younger were apprehended with a BAC below0.05%, reflecting a breach of the zero tolerance BAC for provisional licence holders in Australia. Older women were more likely to be charged with a ‘failure to provide a test’ offence as a result of refusing to provide a breath or blood sample, indicating that drink driving is associated high levels of stigma for this group. Reoffending occurred among 16.2% of the female drink drivers and these drivers were more likely than non-reoffending drivers to record a mid to high range BAC, to be aged 30-39 or below 21years, and to be apprehended in Inner Regional or Remote locations. Conclusion Findings highlight the unique circumstances and divergent needs of female drink drivers compared to male drivers and for different groups of female drivers.
Resumo:
Within the cardiac high dependency unit it is currently a member of the surgical team who makes the decision for a patient's chest drain to be removed after cardiac surgery. This has often resulted in delays in discharging one patient and therefore in admitting the next. A pilot study was carried out using a working standard that had been developed, incorporating an algorithmic model. The results have enabled nursing staff in a cardiac high dependency unit to undertake this responsibility independently.
Resumo:
We present a pole inspection system for outdoor environments comprising a high-speed camera on a vertical take-off and landing (VTOL) aerial platform. The pole inspection task requires a vehicle to fly close to a structure while maintaining a fixed stand-off distance from it. Typical GPS errors make GPS-based navigation unsuitable for this task however. When flying outdoors a vehicle is also affected by aerodynamics disturbances such as wind gusts, so the onboard controller must be robust to these disturbances in order to maintain the stand-off distance. Two problems must therefor be addressed: fast and accurate state estimation without GPS, and the design of a robust controller. We resolve these problems by a) performing visual + inertial relative state estimation and b) using a robust line tracker and a nested controller design. Our state estimation exploits high-speed camera images (100Hz) and 70Hz IMU data fused in an Extended Kalman Filter (EKF). We demonstrate results from outdoor experiments for pole-relative hovering, and pole circumnavigation where the operator provides only yaw commands. Lastly, we show results for image-based 3D reconstruction and texture mapping of a pole to demonstrate the usefulness for inspection tasks.
Resumo:
An alternative learning approach for destructive testing of structural specimens in civil engineering is explored by using a remote laboratory experimentation method. The remote laboratory approach focuses on overcoming the constraints in the hands-on experimentation without compromising the understanding of the students on the concepts and mechanics of reinforced concrete structures. The goal of this study is to evaluate whether or not the remote laboratory experimentation approach can become a standard in civil engineering teaching. The teaching activity using remote-laboratory experimentation is presented here and the outcomes of this activity are outlined. The experience and feedback gathered from this study are used to improve the remote-laboratory experimentation approach in future years to other aspects of civil engineering where destructive testing is essential.
Resumo:
Presentation by Dr Caroline Grant, Science & Engineering Faculty, IHBI, at Managing your research data seminar, 2012