928 resultados para Antonin Artaud. Encenação Performática. Performance. Infecção
Resumo:
The effective daylighting of multistorey commercial building interiors poses an interesting problem for designers in Australia’s tropical and subtropical context. Given that a building exterior receives adequate sun and skylight as dictated by location-specific factors such as weather, siting and external obstructions; then the availability of daylight throughout its interior is dependant on certain building characteristics: the distance from a window façade (room depth), ceiling or window head height, window size and the visible transmittance of daylighting apertures. The daylighting of general stock, multistorey commercial buildings is made difficult by their design limitations with respect to some of these characteristics. The admission of daylight to these interiors is usually exclusively by vertical windows. Using conventional glazing, such windows can only admit sun and skylight to a depth of approximately 2 times the window height. This penetration depth is typically much less than the depth of the office interiors, so that core areas of these buildings receive little or no daylight. This issue is particularly relevant where deep, open plan office layouts prevail. The resulting interior daylight pattern is a relatively narrow perimeter zone bathed in (sometimes too intense) light, contrasted with a poorly daylit core zone. The broad luminance range this may present to a building occupant’s visual field can be a source of discomfort glare. Furthermore, the need in most tropical and subtropical regions to restrict solar heat gains to building interiors for much of the year has resulted in the widespread use of heavily tinted or reflective glazing on commercial building façades. This strategy reduces the amount of solar radiation admitted to the interior, thereby decreasing daylight levels proportionately throughout. However this technique does little to improve the way light is distributed throughout the office space. Where clear skies dominate weather conditions, at different times of day or year direct sunlight may pass unobstructed through vertical windows causing disability or discomfort glare for building occupants and as such, its admission to an interior must be appropriately controlled. Any daylighting system to be applied to multistorey commercial buildings must consider these design obstacles, and attempt to improve the distribution of daylight throughout these deep, sidelit office spaces without causing glare conditions. The research described in this thesis delineates first the design optimisation and then the actual prototyping and manufacture process of a daylighting device to be applied to such multistorey buildings in tropical and subtropical environments.
Resumo:
Vigilance declines when exposed to highly predictable and uneventful tasks. Monotonous tasks provide little cognitive and motor stimulation and contribute to human errors. This paper aims to model and detect vigilance decline in real time through participant’s reaction times during a monotonous task. A lab-based experiment adapting the Sustained Attention to Response Task (SART) is conducted to quantify the effect of monotony on overall performance. Then relevant parameters are used to build a model detecting hypovigilance throughout the experiment. The accuracy of different mathematical models are compared to detect in real-time – minute by minute - the lapses in vigilance during the task. We show that monotonous tasks can lead to an average decline in performance of 45%. Furthermore, vigilance modelling enables to detect vigilance decline through reaction times with an accuracy of 72% and a 29% false alarm rate. Bayesian models are identified as a better model to detect lapses in vigilance as compared to Neural Networks and Generalised Linear Mixed Models. This modelling could be used as a framework to detect vigilance decline of any human performing monotonous tasks.
Resumo:
William Gibson’s The Miracle Worker was staged at the Brisbane Powerhouse June 2009 by Crossbow Productions. In this adaption, people with hearing impairment were privileged through the use of shadow-signing, unscripted signing and the appropriation of signing as a theatrical language in itself. 250 people living with hearing impairment attended the production, 70 had never attended a theatrical event before. During the post-performance discussions hearing audience members expressed feelings of displacement through experiencing the culture of the deaf society and not grasping some of the ideas. This paper argues that this inversion enhanced meaning making for all and illustrates a way forward to encourage the signing of more theatrical events.
Resumo:
Contemporary mainstream theatre audiences observe etiquette strictures that regulate behaviour. As Baz Kershaw argues, “the idea of the passive audience for performance has been associated usually with mainstream theatre.” This paper explores a mainstream event where the extant contract of audience silence was replaced with a raw, emotional audience response that continued into the post-performance discussion. William Gibson’s The Miracle Worker was performed by Crossbow Productions at the Brisbane Powerhouse to an audience made up of mainstream theatre patrons and people living with hearing and visual impairment. Various elements such as shadow signing and tactile tours worked metatheatrically and self-referentially to heighten audience awareness. During the performances the verbal and non-verbal responses of the audience were so pervasive that the audience became not only co-creators of the performance text but performers of a rich audience text that had a dramatic impact on the theatrical experience for audience and actors alike. During the post-performance discussion the audience performers spilled onto the stage interacting with the actors, extending the pleasure of the experience. This paper discusses how in privileging the audience as co-creators and performers, the chasm between stage and audience was bridged. The audiences’ performance changed, enriched and created new meanings for each performance.
Resumo:
Background Wandering represents a major problem in the management of patients with Alzheimer’s disease (AD). In this study we examined the utility of the Algase Wandering Scale (AWS), a newly developed psychometric instrument that asks caregivers to assess the likelihood of wandering behavior. Methods The AWS was administered to the caregivers of 40 AD patients and total and subscale scores were examined in relation to measures of mental and functional status, depressive symptoms and medication usage. Results AWS scores were comparable, though slightly lower, than those normative values previously published. Higher scores were associated with more severe dementia. The Negative Outcome subscale showed a significant increase in reported falls or injuries in association with anti-depressant use. Conclusions These data provide some construct validation for the AWS as a potentially useful scale to assess wandering behaviors in AD.
Resumo:
Simulation study of a custom power park (CPP) is presented. It is assumed that the park contains unbalanced and nonlinear loads in addition to a sensitive load. Two different types of compensators are used separately to protect the sensitive load against unbalance and distortion caused by the other loads. It has been shown that a shunt compensator can regulate the voltage of the CPP bus, whereas the series compensator can only regulate the sensitive load terminal voltage. Additional issues such as the load transfer through a static transfer switch, detection of sag/fault etc. are also discussed. The concepts are validated through PSCAD/EMTDC simulation studies on a sample distribution system.
Resumo:
This paper presents a travel time prediction model and evaluates its performance and transferability. Advanced Travelers Information Systems (ATIS) are gaining more and more importance, increasing the need for accurate, timely and useful information to the travelers. Travel time information quantifies the traffic condition in an easy to understand way for the users. The proposed travel time prediction model is based on an efficient use of nearest neighbor search. The model is calibrated for optimal performance using Genetic Algorithms. Results indicate better performance by using the proposed model than the presently used naïve model.
Resumo:
Field studies show that the internal screens in a gross pollutant trap (GPT) are often clogged with organic matter, due to infrequent cleaning. The hydrodynamic performance of a GPT with fully blocked screens was comprehensively investigated under a typical range of onsite operating conditions. Using an acoustic Doppler velocimeter (ADV), velocity profiles across three critical sections of the GPT were measured and integrated to examine the net fluid flow at each section. The data revealed that when the screens are fully blocked, the flow structure within the GPT radically changes. Consequently, the capture/retention performance of the device rapidly deteriorates. Good agreement was achieved between the experimental and the previous 2D computational fluid dynamics (CFD) velocity profiles for the lower GPT inlet flow conditions.