397 resultados para Rudy, Gerard
Resumo:
Australia is rich in renewable energy resources such as wind, solar and geothermal. Geographical diversity of these renewable resources combined with developing climate change policies poses a great challenge for the long term interconnection planning. Intermittency of wind and solar potentially driving the development of new transmission lines bring additional complexity to power system operations and planning. This paper provides an overview of generation and transmission planning studies in Australia to meet 20% renewable energy target by 2020. Appraisal of the effectiveness of dispersed energy storage, non schedulable peaking plants, wide area controls and demand management techniques to aid the penetration of renewables is presented in this paper
Resumo:
The security of power transfer across a given transmission link is typically a steady state assessment. This paper develops tools to assess machine angle stability as affected by a combination of faults and uncertainty of wind power using probability analysis. The paper elaborates on the development of the theoretical assessment tool and demonstrates its efficacy using single machine infinite bus system.
Resumo:
A review of the issues for supporting learning of power engineering in Australia is presented in this paper. The learning needs of students and the support available in blended learning and through distance educations are explored in this review. Specific software tools to assist the learning environment are appraised and the relevance for the next generation of power engineers assessed.
Resumo:
With the advent of large-scale wind farms and their integration into electrical grids, more uncertainties, constraints and objectives must be considered in power system development. It is therefore necessary to introduce risk-control strategies into the planning of transmission systems connected with wind power generators. This paper presents a probability-based multi-objective model equipped with three risk-control strategies. The model is developed to evaluate and enhance the ability of the transmission system to protect against overload risks when wind power is integrated into the power system. The model involves: (i) defining the uncertainties associated with wind power generators with probability measures and calculating the probabilistic power flow with the combined use of cumulants and Gram-Charlier series; (ii) developing three risk-control strategies by specifying the smallest acceptable non-overload probability for each branch and the whole system, and specifying the non-overload margin for all branches in the whole system; (iii) formulating an overload risk index based on the non-overload probability and the non-overload margin defined; and (iv) developing a multi-objective transmission system expansion planning (TSEP) model with the objective functions composed of transmission investment and the overload risk index. The presented work represents a superior risk-control model for TSEP in terms of security, reliability and economy. The transmission expansion planning model with the three risk-control strategies demonstrates its feasibility in the case study using two typical power systems
Resumo:
This paper evaluates the age-associated changes of resting ventilation of 115 high- and low-altitude Aymara subjects, of whom 61 were from the rural Aymara village of Ventilla situated at an average altitude of 4,200 m and 54 from the rural village of Caranavi situated at an average altitude of 900 m. Comparison of the age patterns of resting ventilation suggests the following conclusions: 1) the resting ventilation (ml/kg/min) of high-altitude natives is markedly higher than that of low-altitude natives; 2) the age decline of ventilation is similar in both lowlanders and highlanders, but the starting point and therefore the age decline are much higher at high altitude; 3) the resting ventilation that characterizes high-altitude Andean natives is developmentally expressed in the same manner as it is at low altitude; and 4) the resting ventilation (ml/kg/min) of Aymara high-altitude natives is between 40–80% lower than that of Tibetans. Am J Phys Anthropol 109:295–301, 1999. © 1999 Wiley-Liss, Inc.
Resumo:
Objective. To determine the impact of the introduction of universal access to ambulance services via the implementation of the Community Ambulance Cover (CAC) program in Queensland in 2003–04. Method. The study involved a 10-year (2000–01 to 2009–10) retrospective analysis of routinely collected data reported by the Queensland Ambulance Service (QAS) and by the Council of Ambulance Authorities. The data were analysed for the impact of policy changes that resulted in universal access to ambulance services in Queensland. Results. QASis a statewide, publically funded ambulance service. In Queensland, ambulance utilisation rate (AUR)per 1000 persons grew by 41% over the decade or 3.9% per annum (10-year mean = 149.8, 95% CI: 137.3–162.3). The AUR mean after CAC was significantly higher for urgent incidents than for non-urgent ones. However projection modelling demonstrates that URs after the introduction of CAC were significantly lower than the projected utilisation for the same period. Conclusions. The introduction of universal access under the Community Ambulance Cover program in Queensland has not had any significant independent long-term impact on demand overall. There has been a reduction in the long-term growth rate, which may have been contributed to by an ‘appropriate use’ public awareness program.
Resumo:
An iterative based strategy is proposed for finding the optimal rating and location of fixed and switched capacitors in distribution networks. The substation Load Tap Changer tap is also set during this procedure. A Modified Discrete Particle Swarm Optimization is employed in the proposed strategy. The objective function is composed of the distribution line loss cost and the capacitors investment cost. The line loss is calculated using estimation of the load duration curve to multiple levels. The constraints are the bus voltage and the feeder current which should be maintained within their standard range. For validation of the proposed method, two case studies are tested. The first case study is the semi-urban 37-bus distribution system which is connected at bus 2 of the Roy Billinton Test System which is located in the secondary side of a 33/11 kV distribution substation. The second case is a 33 kV distribution network based on the modification of the 18-bus IEEE distribution system. The results are compared with prior publications to illustrate the accuracy of the proposed strategy.
Resumo:
To ensure the small-signal stability of a power system, power system stabilizers (PSSs) are extensively applied for damping low frequency power oscillations through modulating the excitation supplied to synchronous machines, and increasing interest has been focused on developing different PSS schemes to tackle the threat of damping oscillations to power system stability. This paper examines four different PSS models and investigates their performances on damping power system dynamics using both small-signal eigenvalue analysis and large-signal dynamic simulations. The four kinds of PSSs examined include the Conventional PSS (CPSS), Single Neuron based PSS (SNPSS), Adaptive PSS (APSS) and Multi-band PSS (MBPSS). A steep descent parameter optimization algorithm is employed to seek the optimal PSS design parameters. To evaluate the effects of these PSSs on improving power system dynamic behaviors, case studies are carried out on an 8-unit 24-bus power system through both small-signal eigenvalue analysis and large-signal time-domain simulations.
Resumo:
With the progressive exhaustion of fossil energy and the enhanced awareness of environmental protection, more attention is being paid to electric vehicles (EVs). Inappropriate siting and sizing of EV charging stations could have negative effects on the development of EVs, the layout of the city traffic network, and the convenience of EVs' drivers, and lead to an increase in network losses and a degradation in voltage profiles at some nodes. Given this background, the optimal sites of EV charging stations are first identified by a two-step screening method with environmental factors and service radius of EV charging stations considered. Then, a mathematical model for the optimal sizing of EV charging stations is developed with the minimization of total cost associated with EV charging stations to be planned as the objective function and solved by a modified primal-dual interior point algorithm (MPDIPA). Finally, simulation results of the IEEE 123-node test feeder have demonstrated that the developed model and method cannot only attain the reasonable planning scheme of EV charging stations, but also reduce the network loss and improve the voltage profile.
Resumo:
This paper proposes a new approach for state estimation of angles and frequencies of equivalent areas in large power systems with synchronized phasor measurement units. Defining coherent generators and their correspondent areas, generators are aggregated and system reduction is performed in each area of inter-connected power systems. The structure of the reduced system is obtained based on the characteristics of the reduced linear model and measurement data to form the non-linear model of the reduced system. Then a Kalman estimator is designed for the reduced system to provide an equivalent dynamic system state estimation using the synchronized phasor measurement data. The method is simulated on two test systems to evaluate the feasibility of the proposed method.
Resumo:
Emergency health is a critical component of Australia’s health system and one which is increasingly congested from growing demand and blocked access to inpatient beds. The Emergency Health Services Queensland (EHSQ) study aims to identify the factors driving increased demand for emergency health and to evaluate strategies which may safely reduce the future demand growth. This monograph addresses the characteristics of users of emergency health services with an aim to identify those that appear to contribute to demand growth. This study utilises data on patients treated by Emergency Departments (ED) and Queensland Ambulance Service (QAS) across Queensland. ED data was derived from the Emergency Department Information System (EDIS) for the period 2001-02 through to 2010-11. Ambulance data was extracted from the QAS’ Ambulance Information Management System (AIMS) and electronic Ambulance Report Form (eARF) for the period 2001-02 through to 2009-10. Due to discrepancies and comparability issues for ED data, this monograph compares data from the 2003-04 time period with 2010-11 data for 21 of the reporting EDs. Also a snapshot of users for the 2010-11 financial year for 31 reporting EDs is used to describe the characteristics of users and to compare those characteristics with population demographics. For QAS data, the 2002-03 and 2009-10 time periods were selected for detailed analyses to identify trends. • Demand for emergency health care services is increasing, representing both increased population and increased relative utilisation. Per capita demand for ED attention has increased by 2% per annum over the last decade and for ambulance attention by 3.7% per annum. • The growth in ED demand is prominent in more urgent triage categories with actual decline in less urgent patients. An estimated 55% of patients attend hospital EDs outside of normal working hours. There is no evidence that patients presenting out of hours are significantly different to those presenting within working hours; they have similar triage assessments and outcomes. • Patients suffering from injuries and poisoning comprise 28% of the ED workload (an increase of 65% in the study period), whilst declines of 32% in cardiovascular and circulatory conditions, and musculoskeletal problems have been observed. • 25.6% of patients attending EDs are admitted to hospital. 19% of admitted patients and 7% of patients who die in the ED are triage category 4 or 5 on arrival. • The average age of ED patients is 35.6 years. Demand has grown in all age groups and amongst both men and women. Men have higher utilisation rates for ED in all age groups. The only group where the growth rate in women has exceeded men is in the 20-29 age group; this growth is particularly in the injury and poisoning categories. • Considerable attention has been paid publicly to ED performance criteria. It is worth noting that 50% of all patients were treated within 33 minutes of arrival. • Patients from lower socioeconomic areas appear to have higher utilisation rates and the utilisation rate for indigenous people appears to exceed those of European and other backgrounds. The utilisation rates for immigrant people is generally less than that of Australian born however it has not been possible to eliminate the confounding impact of different age and socioeconomic profiles. • Demand for ambulance service is also increasing at a rate that exceeds population growth. Utilisation rates have increased by an average of 5% per annum in Queensland compared to 3.6% nationally, and the utilisation rate in Queensland is 27% higher than the national average. • The growth in ambulance utilisation has also been amongst the more urgent categories of dispatch and utilisation rates are higher in rural and regional areas than in the metropolitan area. The demand for ambulance increases with age but the growth in demand for ambulance service has been more prominent in younger age groups. These findings contribute significantly to an understanding of the growth in demand for emergency health. It shows that the growth is amongst patients in genuine need of emergency healthcare and public rhetoric that the congestion of emergency health services is due to inappropriate attendees is unable to be substantiated. The consistency of the growth in demand over the last decade reflects not only the changing demographics of the Australian population but also the changes in health status, standards of acute health care and other social factors. The growth is also amongst patients with acute injury and poisoning which is inconsistent with rates of chronic disease as a fundamental driver. We have also interviewed patients in regard to their decision making choices for acute health care and the factors that influence these decisions and this will be the subject of a third Monograph and publications.
A hybrid simulation framework to assess the impact of renewable generators on a distribution network
Resumo:
With an increasing number of small-scale renewable generator installations, distribution network planners are faced with new technical challenges (intermittent load flows, network imbalances…). Then again, these decentralized generators (DGs) present opportunities regarding savings on network infrastructure if installed at strategic locations. How can we consider both of these aspects when building decision tools for planning future distribution networks? This paper presents a simulation framework which combines two modeling techniques: agent-based modeling (ABM) and particle swarm optimization (PSO). ABM is used to represent the different system units of the network accurately and dynamically, simulating over short time-periods. PSO is then used to find the most economical configuration of DGs over longer periods of time. The infrastructure of the framework is introduced, presenting the two modeling techniques and their integration. A case study of Townsville, Australia, is then used to illustrate the platform implementation and the outputs of a simulation.
Resumo:
The behaviour of single installations of solar energy systems is well understood; however, what happens at an aggregated location, such as a distribution substation, when output of groups of installations cumulate is not so well understood. This paper considers groups of installations attached to distributions substations on which the load is primarily commercial and industrial. Agent-based modelling has been used to model the physical electrical distribution system and the behaviour of equipment outputs towards the consumer end of the network. The paper reports the approach used to simulate both the electricity consumption of groups of consumers and the output of solar systems subject to weather variability with the inclusion of cloud data from the Bureau of Meteorology (BOM). The data sets currently used are for Townsville, North Queensland. The initial characteristics that indicate whether solar installations are cost effective from an electricity distribution perspective are discussed.
Resumo:
Resistance to chemotherapy and metastases are the major causes of breast cancer-related mortality. Moreover, cancer stem cells (CSC) play critical roles in cancer progression and treatment resistance. Previously, it was found that CSC-like cells can be generated by aberrant activation of epithelial–mesenchymal transition (EMT), thereby making anti-EMT strategies a novel therapeutic option for treatment of aggressive breast cancers. Here, we report that the transcription factor FOXC2 induced in response to multiple EMT signaling pathways as well as elevated in stem cell-enriched factions is a critical determinant of mesenchymal and stem cell properties, in cells induced to undergo EMT- and CSC-enriched breast cancer cell lines. More specifically, attenuation of FOXC2 expression using lentiviral short hairpin RNA led to inhibition of the mesenchymal phenotype and associated invasive and stem cell properties, which included reduced mammosphere-forming ability and tumor initiation. Whereas, overexpression of FOXC2 was sufficient to induce CSC properties and spontaneous metastasis in transformed human mammary epithelial cells. Furthermore, a FOXC2-induced gene expression signature was enriched in the claudin-low/basal B breast tumor subtype that contains EMT and CSC features. Having identified PDGFR-β to be regulated by FOXC2, we show that the U.S. Food and Drug Administration-approved PDGFR inhibitor, sunitinib, targets FOXC2-expressing tumor cells leading to reduced CSC and metastatic properties. Thus, FOXC2 or its associated gene expression program may provide an effective target for anti-EMT-based therapies for the treatment of claudin-low/basal B breast tumors or other EMT-/CSC-enriched tumors.
Resumo:
Power system restoration after a large area outage involves many factors, and the procedure is usually very complicated. A decision-making support system could then be developed so as to find the optimal black-start strategy. In order to evaluate candidate black-start strategies, some indices, usually both qualitative and quantitative, are employed. However, it may not be possible to directly synthesize these indices, and different extents of interactions may exist among these indices. In the existing black-start decision-making methods, qualitative and quantitative indices cannot be well synthesized, and the interactions among different indices are not taken into account. The vague set, an extended version of the well-developed fuzzy set, could be employed to deal with decision-making problems with interacting attributes. Given this background, the vague set is first employed in this work to represent the indices for facilitating the comparisons among them. Then, a concept of the vague-valued fuzzy measure is presented, and on that basis a mathematical model for black-start decision-making developed. Compared with the existing methods, the proposed method could deal with the interactions among indices and more reasonably represent the fuzzy information. Finally, an actual power system is served for demonstrating the basic features of the developed model and method.