211 resultados para contact mechanics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare kinematics and kinetics during walking for healthy subjects using unstable shoes with different designs. Ten subjects participated in this study, and foot biomechanical data during walking were quantified using motion analysis system and a force plate. Data were collected for unstable shoes condition after accommodation period of one week. With soft material added in the heel region, the peak impact force was effectively reduced when compared among similar shapes. In addition, the soft material added in the rocker bottom showed more to be in dorsiflexed position during the initial stance. The shoe with three rocker curves design reduced the contact area in the heel strike, which may result in increasing human body forward speed. Further studies shall be carried out after adapting to long periods of wearing unstable shoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation proposed a novel experimental model combining a defect configuration with an active instrumented fixation device to investigate the influence of mechanics on bone healing. The proposed defect configuration aimed to minimise physiological loading within an experimental fracture gap and the instrumented fixator was used for the application of controlled displacements and in vivo stiffness monitoring of the healing process. This thesis has provided a novel approach to advance current knowledge and understanding of mechanobiology, which has been limited in previous experimental models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

- Purpose To examine the change in corneal thickness and posterior curvature following 8 hours of miniscleral contact lens wear. - Methods Scheimpflug imaging (Pentacam HR, Oculus) was captured before, and immediately following, 8 hours of miniscleral contact lens wear for 15 young (mean age 22 ± 3 years), healthy participants with normal corneae. Natural diurnal variations were considered by measuring baseline corneal changes obtained on a separate control day without contact lens wear. - Results Over the central 6 mm of the cornea, a small, but highly statistically significant amount of edema was observed following 8 hours of miniscleral lens wear, after accounting for normal diurnal fluctuations (mean ± standard deviation percentage swelling 1.70 ± 0.98%, p < 0.0001). Posterior corneal topography remained stable following lens wear (-0.01 ± 0.07 mm steepening over the central 6 mm, p = 0.60). The magnitude of posterior corneal topographical changes following lens wear did not correlate with the extent of lens-related corneal edema (r = -0.16, p = 0.57). Similarly, the initial central corneal vault (maximum post-lens tear layer depth) was not associated with corneal swelling following lens removal (r = 0.27, p = 0.33). - Conclusions While a small amount of corneal swelling was induced following 8 hours of miniscleral lens wear (on average <2%), modern high Dk miniscleral contact lenses that vault the cornea do not induce clinically significant corneal edema or hypoxic related posterior corneal curvature changes during short-term wear. Longer-term studies of compromised eyes (e.g. corneal ectasia) are still required to inform the optimum lens and fitting characteristics for safe scleral lens wear to minimize corneal hypoxia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the late 1990s, the International Contact Lens Prescribing Survey Consortium has prospectively gathered information about 285,000 contact lens fits from more than 50 countries. This article presents our 14th annual summary of current trends published in Contact Lens Spectrum. With only minor differences in the distribution of our surveys among markets, we have continued to adopt the same approach throughout the past 18 years. Through national coordinators, we approach contact lens prescribers in each country and ask them to record information about the first 10 patients whom they fit with contact lenses after receipt of our survey form. The information collected is generic, and respondents are weighted to reflect the volume of contact lens fits undertaken by each. For this 2014 report, we present information about 25,179 contact lens fits from 32 countries...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To eye care practitioners, citation metrics may seem to be a somewhat esoteric and irrelevant concept, far removed from the realities or real world, day-to-day clinical practice. However, quantitative analysis of the published literature is becoming increasingly important, and a beautiful example of this is presented in this issue of the Journal of Optometry. My former PhD student, Genís Cardona, has teamed up with Joan Sanz to undertake a thorough and telling analysis of current worldwide publishing trends in the contact lens field. When held in the mirror, this work reflects the growing contributions from Spanish researchers to the field...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efron, Morgan and Woods share the findings of their latest annual survey of Australian contact lens prescribing habits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have been collecting data on worldwide contact lens prescribing habits for almost 20 years. Over this time period, we have amassed prospective information about 315,000 contact lens fits in 59 countries. This article marks our 15th report in Contact Lens Spectrum and features a breakdown of more than 23,000 contact lens fits in 34 markets. As in previous years, our international network of coordinators distributed survey forms to eyecare practitioners in their market who then recorded generic information about the first 10 patients fit with contact lenses after receipt. Information is gathered about patient age and gender; whether the contact lenses are prescribed as a new fit or a refit; contact lens material, design, and replacement frequency; number of intended days per week of use; wearing modality; and care system. Contact lens fits are weighted to reflect the number of fits undertaken by each eyecare practitioner. The study data were entered and processed at the University of Manchester and at the University of Waterloo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on socio-emotional selectivity and self-categorization theories, we developed and tested a model on how the interplay between employee age and opportunities for generativity and development predicts age bias and turnover intentions via intergenerational contact quality in the workplace. We hypothesized indirect effects of opportunities for generativity on outcomes through intergenerational contact quality among older workers only, whereas we expected that the indirect effects of opportunities for development are stronger for young compared with older workers. Data came from 321 employees in Belgium who responded to an online questionnaire. Results showed that age moderated the relationships of opportunities for generativity and development with intergenerational contact quality consistent with the expected patterns. Furthermore, age moderated the indirect effects of opportunities for generativity and development on age bias through intergenerational contact quality, but not on turnover intentions. Implications for future research and practical suggestions for managing intergenerational contact at work are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To quantify the influence of short-term wear of miniscleral contact lenses on the morphology of the corneo-scleral limbus, the conjunctiva, episclera and sclera. METHODS OCT images of the anterior eye were captured before, immediately following 3h of wear and then 3h after removal of a miniscleral contact lens for 10 young (27±5 years) healthy participants (neophyte rigid lens wearers). The region of analysis encompassed 1mm anterior, to 3.5mm posterior to the scleral spur. Natural diurnal variations in thickness were measured on a separate day and compensated for in subsequent analyses. RESULTS Following 3h of lens wear, statistically significant tissue thinning was observed across all quadrants, with a mean decrease in thickness of -24.1±3.6μm (p<0.001), which diminished, but did not return to baseline 3h after lens removal (-16.9±1.9μm, p<0.001). The largest tissue compression was observed in the superior quadrant (-49.9±8.5μm, p<0.01) and in the annular zone 1.5mm from the scleral spur (-48.2±5.7μm), corresponding to the approximate edge of the lens landing zone. Compression of the conjunctiva/episclera accounted for about 70% of the changes. CONCLUSIONS Optimal fitting miniscleral contact lenses worn for three hours resulted in significant tissue compression in young healthy eyes, with the greatest thinning observed superiorly, potentially due to the additional force of the eyelid, with a partial recovery of compression 3h after lens removal. Most of the morphological changes occur in the conjunctiva/episclera layers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Masonry under compression is affected by the properties of its constituents and their interfaces. In spite of extensive investigations of the behaviour of masonry under compression, the information in the literature cannot be regarded as comprehensive due to ongoing inventions of new generation products – for example, polymer modified thin layer mortared masonry and drystack masonry. As comprehensive experimental studies are very expensive, an analytical model inspired by damage mechanics is developed and applied to the prediction of the compressive behaviour of masonry in this paper. The model incorporates a parabolic progressively softening stress-strain curve for the units and a progressively stiffening stress-strain curve until a threshold strain for the combined mortar and the unit-mortar interfaces is reached. The model simulates the mutual constraints imposed by each of these constituents through their respective tensile and compressive behaviour and volumetric changes. The advantage of the model is that it requires only the properties of the constituents and considers masonry as a continuum and computes the average properties of the composite masonry prisms/wallettes; it does not require discretisation of prism or wallette similar to the finite element methods. The capability of the model in capturing the phenomenological behaviour of masonry with appropriate elastic response, stiffness degradation and post peak softening is presented through numerical examples. The fitting of the experimental data to the model parameters is demonstrated through calibration of some selected test data on units and mortar from the literature; the calibrated model is shown to predict the responses of the experimentally determined masonry built using the corresponding units and mortar quite well. Through a series of sensitivity studies, the model is also shown to predict the masonry strength appropriately for changes to the properties of the units and mortar, the mortar joint thickness and the ratio of the height of unit to mortar joint thickness. The unit strength is shown to affect the masonry strength significantly. Although the mortar strength has only a marginal effect, reduction in mortar joint thickness is shown to have a profound effect on the masonry strength. The results obtained from the model are compared with the various provisions in the Australian Masonry Structures Standard AS3700 (2011) and Eurocode 6.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the study, we used the Agilent 8453 spectrophotometer (which is equipped with a limiting aperture that restricts the light beam to the central 5 mm of the contact lens), to measure the transmittance of various coloured contact lenses including the one Day Acuvue define manufactured by Johnson and Johnson which the authors represent. We measured the instrument baseline before the transmittance spectra of lenses were tested. The values of lens transmittances were thus the difference between baseline and lens measurement at each time. The transmittance measurements were obtained at 0.5 nm intervals, from 200 to 700 nm after a soak in saline to remove the influence of any surface active agents within the packaging products. The technique used in our study was not very different from how other research studies [2], [3], [4], [5] and [6] have measured the spectra transmittances of contact lenses...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To quantify regional (nasal, superior, temporal and inferior) and location specific (corneal and scleral) tissue compression following short-term miniscleral contact lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the advent of varied types of masonry systems a comprehensive failure mechanism of masonry essential for the understanding of its behaviour is impossible to be determined from experimental testing. As masonry is predominantly used in wall structures a biaxial stress state dominates its failure mechanism. Biaxial testing will therefore be necessary for each type of masonry, which is expensive and time consuming. A computational method would be advantageous; however masonry is complex to model which requires advanced computational modelling methods. This thesis has formulated a damage mechanics inspired modelling method and has shown that the method effectively determines the failure mechanisms and deformation characteristics of masonry under biaxial states of loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissatisfaction with, and discontinuation from, contact lens wear is a source of major frustration and inconvenience to users, and a problem that is thought to cost the contact lens industry hundreds of millions of dollars each year. By directly and non-invasively monitoring inflammatory cells in the tissues at the front of the eye in symptomatic and asymptomatic lens wearers, the candidate has been able to demonstrate an inflammatory basis for contact lens discomfort. This finding may pave the way towards the development of strategies to make contact lenses more safe and afford greater levels of comfort.