383 resultados para Load-line.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of increased training (IT) load on plasma concentrations of lipopolysaccharides (LPS), proinflammatory cytokines, and anti-LPS antibodies during exercise in the heat were investigated in 18 male runners, who performed 14 days of normal training (NT) or 14 days of 20% IT load in 2 equal groups. Before (trial 1) and after (trial 2) the training intervention, all subjects ran at 70% maximum oxygen uptake on a treadmill under hot (35 degrees C) and humid (similar to 40%) conditions, until core temperature reached 39.5 degrees C or volitional exhaustion. Venous blood samples were drawn before, after, and 1.5 h after exercise. Plasma LPS concentration after exercise increased by 71% (trial 1, p < 0.05) and 21% (trial 2) in the NT group and by 92% (trial 1, p < 0.01) and 199% (trial 2, p < 0.01) in the IT group. Postintervention plasma LPS concentration was 35% lower before exercise (p < 0.05) and 47% lower during recovery (p < 0.01) in the IT than in the NT group. Anti-LPS IgM concentration during recovery was 35% lower in the IT than in the NT group (p < 0.05). Plasma interleukin (IL)-6 and tumor necrosis factor (TNF)-alpha concentrations after exercise (IL-6, 3-7 times, p < 0.01, and TNF-alpha, 33%, p < 0.01) and during recovery (IL-6, 2-4 times, p < 0.05, and TNF-alpha, 30%, p < 0.01) were higher than at rest within each group. These data suggest that a short-term tolerable increase in training load may protect against developing endotoxemia during exercise in the heat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When wheels pass over insulated rail joints (IRJs) a vertical impact force is generated. The ability to measure the impact force is valuable as the force signature helps understand the behaviour of the IRJs, in particular their potential for failure. The impact forces are thought to be one of the main factors that cause damage to the IRJ and track components. Study of the deterioration mechanism helps finding new methods to improve the service life of IRJs in track. In this research, the strain-gage-based wheel load detector, for the first time, is employed to measure the wheel–rail contact-impact force at an IRJ in a heavy haul rail line. In this technique, the strain gages are installed within the IRJ assembly without disturbing the structural integrity of IRJ and arranged in a full wheatstone bridge to form a wheel load detector. The instrumented IRJ is first tested and calibrated in the lab and then installed in the field. For comparison purposes, a reference rail section is also instrumented with the same strain gage pattern as the IRJ. In this paper the measurement technique, the process of instrumentation, and tests as well as some typical data obtained from the field and the inferences are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deterministic transit capacity analysis applies to planning, design and operational management of urban transit systems. The Transit Capacity and Quality of Service Manual (1) and Vuchic (2, 3) enable transit performance to be quantified and assessed using transit capacity and productive capacity. This paper further defines important productive performance measures of an individual transit service and transit line. Transit work (p-km) captures the transit task performed over distance. Passenger transmission (p-km/h) captures the passenger task delivered by service at speed. Transit productiveness (p-km/h) captures transit work performed over time. These measures are useful to operators in understanding their services’ or systems’ capabilities and passenger quality of service. This paper accounts for variability in utilized demand by passengers along a line and high passenger load conditions where passenger pass-up delay occurs. A hypothetical case study of an individual bus service’s operation demonstrates the usefulness of passenger transmission in comparing existing and growth scenarios. A hypothetical case study of a bus line’s operation during a peak hour window demonstrates the theory’s usefulness in examining the contribution of individual services to line productive performance. Scenarios may be assessed using this theory to benchmark or compare lines and segments, conditions, or consider improvements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of engine backpressure on the performance and emissions of a CI engine under different speed and load conditions. A 4-stroke single cylinder naturally aspirated direct injection (DI) diesel engine was used for the investigation with the backpressure of 0, 40, 60 and 80 mm of Hg at engine speed of 600, 950 and 1200 rpm. Two parameters were measured during the engine operation: one is engine performance (brake thermal efficiency and brake specific fuel consumption), and the other is the exhaust emissions (NOx, CO and odor). NOx and CO emission were measured by flue gas analyzer (IMR 1400). The engine backpressure produced by the flow regulating valve in the exhaust line was measured by Hg (mercury) manometer. The result showed that, the brake thermal efficiency and brake specific fuel consumption (bsfc) are almost unchanged with increasing backpressure up to 40 mm of Hg pressure for all engine speed and load conditions. The NOx emission became constant or a little decreased with increasing backpressure. The formation of CO was slightly higher with increase of load and back pressure at low engine speed condition. However, under high speed conditions, CO reduced significantly with increasing backpressure for all load conditions. The odor level was similar or a little higher with increasing backpressure for all engine speed and load conditions. Hence, backpressure up to a certain level is not detrimental for a CI engine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Cervical cancer and infection with human immunodeficiency virus (HIV) are both important public health problems in South Africa (SA). The aim of this study was to determine the prevalence of cervical squamous intraepithelial lesions (SILs), high-risk human papillomavirus (HR-HPV), HPV viral load and HPV genotypes in HIV positive women initiating anti-retroviral (ARV) therapy. Methods A cross-sectional survey was conducted at an anti-retroviral (ARV) treatment clinic in Cape Town, SA in 2007. Cervical specimens were taken for cytological analysis and HPV testing. The Digene Hybrid Capture 2 (HC2) test was used to detect HR-HPV. Relative light units (RLU) were used as a measure of HPV viral load. HPV types were determined using the Roche Linear Array HPV Genotyping test. Crude associations with abnormal cytology were tested and multiple logistic regression was used to determine independent risk factors for abnormal cytology. Results The median age of the 109 participants was 31 years, the median CD4 count was 125/mm3, 66.3% had an abnormal Pap smear, the HR-HPV prevalence was 78.9% (Digene), the median HPV viral load was 181.1 RLU (HC2 positive samples only) and 78.4% had multiple genotypes. Among women with abnormal smears the most prevalent HR-HPV types were HPV types 16, 58 and 51, all with a prevalence of 28.5%. On univariate analysis HR-HPV, multiple HPV types and HPV viral load were significantly associated with the presence of low and high-grade SILs (LSIL/HSIL). The multivariate logistic regression showed that HPV viral load was associated with an increased odds of LSIL/HSIL, odds ratio of 10.7 (95% CI 2.0 – 57.7) for those that were HC2 positive and had a viral load of ≤ 181.1 RLU (the median HPV viral load), and 33.8 (95% CI 6.4 – 178.9) for those that were HC2 positive with a HPV viral load > 181.1 RLU. Conclusion Women initiating ARVs have a high prevalence of abnormal Pap smears and HR-HPV. Our results underscore the need for locally relevant, rigorous screening protocols for the increasing numbers of women accessing ARV therapy so that the benefits of ARVs are not partially offset by an excess risk in cervical cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An iterative based strategy is proposed for finding the optimal rating and location of fixed and switched capacitors in distribution networks. The substation Load Tap Changer tap is also set during this procedure. A Modified Discrete Particle Swarm Optimization is employed in the proposed strategy. The objective function is composed of the distribution line loss cost and the capacitors investment cost. The line loss is calculated using estimation of the load duration curve to multiple levels. The constraints are the bus voltage and the feeder current which should be maintained within their standard range. For validation of the proposed method, two case studies are tested. The first case study is the semi-urban 37-bus distribution system which is connected at bus 2 of the Roy Billinton Test System which is located in the secondary side of a 33/11 kV distribution substation. The second case is a 33 kV distribution network based on the modification of the 18-bus IEEE distribution system. The results are compared with prior publications to illustrate the accuracy of the proposed strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant wheel-rail dynamic forces occur because of imperfections in the wheels and/or rail. One of the key responses to the transmission of these forces down through the track is impact force on the sleepers. Dynamic analysis of nonlinear systems is very complicated and does not lend itself easily to a classical solution of multiple equations. Trying to deduce the behaviour of track components from experimental data is very difficult because such data is hard to obtain and applies to only the particular conditions of the track being tested. The finite element method can be the best solution to this dilemma. This paper describes a finite element model using the software package ANSYS for various sized flat defects in the tread of a wheel rolling at a typical speed on heavy haul track. The paper explores the dynamic response of a prestressed concrete sleeper to these defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowledge of cable parameters has been well established but a better knowledge of the environment in which the cables are buried lags behind. Research in Queensland University of Technology has been aimed at obtaining and analysing actual daily field values of thermal resistivity and diffusivity of the soil around power cables. On-line monitoring systems have been developed and installed with a data logger system and buried spheres that use an improved technique to measure thermal resistivity and diffusivity over a short period. Results based on long term continuous field data are given. A probabilistic approach is developed to establish the correlation between the measured field thermal resistivity values and rainfall data from weather bureau records. This data from field studies can reduce the risk in cable rating decisions and provide a basis for reliable prediction of “hot spot” of an existing cable circuit

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation guide for the surveillance of CLABSI in intensive care units (ICU) was produced by the Healthcare Associated Infection (HAI) Technical Working Group of the Australian Commission on Safety and Quality in Health Care(ACSQHC), and endorsed by the ACSQHC HAI Advisory Committee. State surveillance units, the ACSQHC and the Australian and New Zealand Intensive Care Society (ANZICS) have representatives on the Technical Working Group, and have provided input into this document.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A short 27 mins docudrama film. The Brisbane Line is a neo noir drama-documentary depicting the forgotten history surrounding the subtropical capital of Queensland, Australia. Set in the shadows of this sunshine city's unsolved crime, the film explores gaps between fact and fiction, memory and myth and excavates Brisbane's original sin [from DVD container]. The Brisbane Line is a film noir about the 1940s police force & corruption in Brisbane. The film is a creative research output, screened at Tribal Cinemas, Brisbane on the 8th November 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new control method for battery storage to maintain acceptable voltage profile in autonomous microgrids is proposed in this article. The proposed battery control ensures that the bus voltages in the microgrid are maintained during disturbances such as load change, loss of micro-sources, or distributed generations hitting power limit. Unlike the conventional storage control based on local measurements, the proposed method is based on an advanced control technique, where the reference power is determined based on the voltage drop profile at the battery bus. An artificial neural network based controller is used to determine the reference power needed for the battery to hold the microgrid voltage within regulation limits. The pattern of drop in the local bus voltage during power imbalance is used to train the controller off-line. During normal operation, the battery floats with the local bus voltage without any power injection. The battery is charged or discharged during the transients with a high gain feedback loop. Depending on the rate of voltage fall, it is switched to power control mode to inject the reference power determined by the proposed controller. After a defined time period, the battery power injection is reduced to zero using slow reverse-droop characteristics, ensuring a slow rate of increase in power demand from the other distributed generations. The proposed control method is simulated for various operating conditions in a microgrid with both inertial and converter interfaced sources. The proposed battery control provides a quick load pick up and smooth load sharing with the other micro-sources in a disturbance. With various disturbances, maximum voltage drop over 8% with conventional energy storage is reduced within 2.5% with the proposed control method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The project examined the responsiveness of the telenursing service provided by the Child Health Line (hereinafter referred to as CHL). It aimed to provide an account of population usage of the service, the call request types and the response of the service to the calls. In so doing, the project extends the current body of knowledge pertaining to the provision of parenting support through telenursing. Approximately 900 calls to the CHL were audio-recorded over the December 2005-2006 Christmas-New Year period. A protocol was developed to code characteristics of the call, the interactional features between the caller and nurse call-taker, and the extent to which there was (a) agreement on problem definition and the plan of action and (b) interactional alignment between nurse and caller. A quantitative analysis examined the frequencies of the main topics covered in calls to the CHL and any statistical associations between types of calls, length of calls and nurse-caller alignment. In addition, a detailed qualitative analysis was conducted on a subset of calls dealing with the nurse management of calls seeking medical advice and information. Key findings include: • Overall, 74% of the calls discussed parenting and child development issues, 48% discussed health/medical issues, and 16% were information-seeking calls. • More specifically: o 21% discussed health/medical and parenting and child development issues. o 3% discussed parenting and information-seeking issues. o 5% discussed health/medical, parenting/development and information issues. o 18% exclusively focussed on health and medical issues and therefore were outside the remit of the intended scope of the CHL. These calls caused interactional dilemmas for the nurse call-takers as they simultaneously dealt with parental expectations for help and the CHL guidelines indicating that offering medical advice was outside the remit of the service. • Most frequent reasons for calling were to discuss sleep, feeding, normative infant physical functions and parenting advice. • The average length of calls to the CHL was 7 minutes. • Longer calls were more likely to involve nurse call-takers giving advice on more than one topic, the caller displaying strong emotions, the caller not specifically providing the reason for the call, and the caller discussing parenting and developmental issues. • Shorter calls were characterised by the nurse suggesting that the child receive immediate medical attention, the nurse emphasising the importance or urgency of the plan of action, the caller referring to or requesting confirmation of a diagnosis, and caller and nurse call-taker discussion of health and medical issues. • The majority of calls, 92%, achieved parent-nurse alignment by the conclusion of the call. However, 8% did not. • The 8% of calls that were not aligned require further quantitative and qualitative investigation of the interactional features. The findings are pertinent in the current context where Child Health Line now resides within 13HEALTH. These findings indicate: 1. A high demand for parenting advice. 2. Nurse call-takers have a high level of competency in dealing with calls about parenting and normal child development, which is the remit of the CHL. 3. Nurse call-takers and callers achieve a high degree of alignment when both parties agree on a course of action. 4. There is scope for developing professional practice in calls that present difficulties in terms of call content, interactional behaviour and call closure. Recommendations of the project: 1. There are numerous opportunities for further research on interactional aspects of calls to the CHL, such as further investigations of the interactional features and the association of the features to alignment and nonalignment. The rich and detailed insights into the patterns of nurse-parent interactions were afforded by the audio-recording and analysis of calls to the CHL. 2. The regular recording of calls would serve as a way of increasing understanding of the type and nature of calls received, and provide a valuable training resource. Recording and analysing calls to CHL provides insight into the operation of the service, including evidence about the effectiveness of triaging calls. 3. Training in both recognising and dealing with problem calls may be beneficial. For example, calls where the caller showed strong emotion, appeared stressed, frustrated or troubled were less likely to be rated as aligned calls. In calls where the callers described being ‘at their wits end’, or responded to each proposed suggestion with ‘I’ve tried that’, the callers were fairly resistant to advice-giving. 4. Training could focus on strategies for managing calls relating to parenting support and advice, and parental well-being. The project found that these calls were more likely to be rated as being nonaligned. 5. With the implementation of 13HEALTH, future research could compare nurse-parent interaction following the implementation of triaging. Of the calls, 21% had both medical and parenting topics discussed and 5.3% discussed medical, parenting and information topics. Added to this, in 12% of calls, there was ambiguity between the caller and nurse call-taker as to whether the problem was medical or behavioural.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Load modeling plays an important role in power system dynamic stability assessment. One of the widely used methods in assessing load model impact on system dynamic response is through parametric sensitivity analysis. Load ranking provides an effective measure of such impact. Traditionally, load ranking is based on either static or dynamic load model alone. In this paper, composite load model based load ranking framework is proposed. It enables comprehensive investigation into load modeling impacts on system stability considering the dynamic interactions between load and system dynamics. The impact of load composition on the overall sensitivity and therefore on ranking of the load is also investigated. Dynamic simulations are performed to further elucidate the results obtained through sensitivity based load ranking approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The well-established under-frequency load shedding (UFLS) is deemed to be the last of effective remedial measures against a severe frequency decline of a power system. With the ever-increasing size of power systems and the extensive penetration of distributed generators (DGs) in power systems, the problem of developing an optimal UFLS strategy is facing some new challenges. Given this background, an optimal UFLS strategy for a distribution system with DGs and load static characteristics taken into consideration is developed. Based on the frequency and the rate of change of frequency, the presented strategy consists of several basic rounds and a special round. In the basic round, the frequency emergency can be alleviated by quickly shedding some loads. In the special round, the frequency security can be maintained, and the operating parameters of the distribution system can be optimized by adjusting the output powers of DGs and some loads. The modified IEEE 37-node test feeder is employed to demonstrate the essential features of the developed optimal UFLS strategy in the MATLAB/SIMULINK environment.