207 resultados para Reliability allocation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodelling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalisation. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values (%SEMs). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants’ variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To assess the performance of the 2Win eccentric videorefractor in relation to subjective refraction and table-mounted autorefraction. METHODS Eighty-six eyes of 86 adults (46 male and 40 female subjects) aged between 20 and 25 years were examined. Subjective refraction and autorefraction using the table-mounted Topcon KR8800 and the handheld 2Win videorefractor were carried out in a randomized fashion by three different masked examiners. Measurements were repeated about 1 week after to assess instrument reproducibility, and the intertest variability was compared between techniques. Agreement of the 2Win videorefractor with subjective refraction and autorefraction was assessed for sphere and for cylindrical vectors at 0 degrees (J0) and 45 degrees (J45). RESULTS Reproducibility coefficients for sphere values measured by subjective refraction, Topcon KR8800, and 2Win (±0.42, ±0.70, and ±1.18, respectively) were better than their corresponding J0 (±1.0, ±0.85, and ±1.66) and J45 (±1.01, ±0.87, and ±1.31) vector components. The Topcon KR8800 showed the most reproducible values for mean spherical equivalent refraction and the J0 and J45 vector components, whereas reproducibility of spherical component was best for subjective refraction. The 2Win videorefractor measurements were the least reproducible for all measures. All refractive components measured by the 2Win videorefractor did not differ significantly from those of subjective refraction, in both sessions (p > 0.05). The Topcon KR8800 autorefractometer and the 2Win videorefractor measured significantly more positive spheres and mean spherical equivalent refraction (p < 0.0001), but the J0 and J45 vector components were similar (p > 0.05), in both sessions. CONCLUSIONS The 2Win videorefractor compares well, on average, with subjective refraction. The reproducibility values for the 2Win videorefractor were considerably worse than either subjective refraction or autorefraction. The wide limits of reproducibility of the 2Win videorefractor probably limit its usefulness as a primary screening device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The capacity to diagnosys, quantify and evaluate movement beyond the general confines of a clinical environment under effectiveness conditions may alleviate rampant strain on limited, expensive and highly specialized medical resources. An iPhone 4® mounted a three dimensional accelerometer subsystem with highly robust software applications. The present study aimed to evaluate the reliability and concurrent criterion-related validity of the accelerations with an iPhone 4® in an Extended Timed Get Up and Go test. Extended Timed Get Up and Go is a clinical test with that the patient get up from the chair and walking ten meters, turn and coming back to the chair. Methods A repeated measure, cross-sectional, analytical study. Test-retest reliability of the kinematic measurements of the iPhone 4® compared with a standard validated laboratory device. We calculated the Coefficient of Multiple Correlation between the two sensors acceleration signal of each subject, in each sub-stage, in each of the three Extended Timed Get Up and Go test trials. To investigate statistical agreement between the two sensors we used the Bland-Altman method. Results With respect to the analysis of the correlation data in the present work, the Coefficient of Multiple Correlation of the five subjects in their triplicated trials were as follows: in sub-phase Sit to Stand the ranged between r = 0.991 to 0.842; in Gait Go, r = 0.967 to 0.852; in Turn, 0.979 to 0.798; in Gait Come, 0.964 to 0.887; and in Turn to Stand to Sit, 0.992 to 0.877. All the correlations between the sensors were significant (p < 0.001). The Bland-Altman plots obtained showed a solid tendency to stay at close to zero, especially on the y and x-axes, during the five phases of the Extended Timed Get Up and Go test. Conclusions The inertial sensor mounted in the iPhone 4® is sufficiently reliable and accurate to evaluate and identify the kinematic patterns in an Extended Timed Get and Go test. While analysis and interpretation of 3D kinematics data continue to be dauntingly complex, the iPhone 4® makes the task of acquiring the data relatively inexpensive and easy to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of modelling correlation has long been recognised in the field of portfolio management, with largedimensional multivariate problems increasingly becoming the focus of research. This paper provides a straightforward and commonsense approach toward investigating a number of models used to generate forecasts of the correlation matrix for large-dimensional problems.We find evidence in favour of assuming equicorrelation across various portfolio sizes, particularly during times of crisis. During periods of market calm, however, the suitability of the constant conditional correlation model cannot be discounted, especially for large portfolios. A portfolio allocation problem is used to compare forecasting methods. The global minimum variance portfolio and Model Confidence Set are used to compare methods, while portfolio weight stability and relative economic value are also considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In the emergency department, portable point-of-care testing (POCT) coagulation devices may facilitate stroke patient care by providing rapid International Normalized Ratio (INR) measurement. The objective of this study was to evaluate the reliability, validity, and impact on clinical decision-making of a POCT device for INR testing in the setting of acute ischemic stroke (AIS). Methods A total of 150 patients (50 healthy volunteers, 51 anticoagulated patients, 49 AIS patients) were assessed in a tertiary care facility. The INR's were measured using the Roche Coaguchek S and the standard laboratory technique. Results The interclass correlation coefficient and 95% confidence interval between overall POCT device and standard laboratory value INRs was high (0.932 (0.69 - 0.78). In the AIS group alone, the correlation coefficient and 95% CI was also high 0.937 (0.59 - 0.74) and diagnostic accuracy of the POCT device was 94%. Conclusions When used by a trained health professional in the emergency department to assess INR in acute ischemic stroke patients, the CoaguChek S is reliable and provides rapid results. However, as concordance with laboratory INR values decreases with higher INR values, it is recommended that with CoaguChek S INRs in the > 1.5 range, a standard laboratory measurement be used to confirm the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We commend Swanenburg et al. (2013) on translation, development, and clinimetric analysis of the NDI-G. However, the dual-factor structure with factor analysis and the high level of internal consistency (IC) highlighted in their discussion were not emphasized in the abstract or conclusion. These points may imply some inconsistencies with the final conclusions since determination of stable point estimates with the study's small sample are exceedingly difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a new method for quantifying intersegmental motion of the spine in an instrumented motion segment L4–L5 model using ultrasound image post-processing combined with an electromagnetic device. A prospective test–retest design was employed, combined with an evaluation of stability and within- and between-day intra-tester reliability during forward bending by 15 healthy male patients. The accuracy of the measurement system using the model was calculated to be ± 0.9° (standard deviation = 0.43) over a 40° range and ± 0.4 cm (standard deviation = 0.28) over 1.5 cm. The mean composite range of forward bending was 15.5 ± 2.04° during a single trial (standard error of the mean = 0.54, coefficient of variation = 4.18). Reliability (intra-class correlation coefficient = 2.1) was found to be excellent for both within-day measures (0.995–0.999) and between-day measures (0.996–0.999). Further work is necessary to explore the use of this approach in the evaluation of biomechanics, clinical assessments and interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human connectome has recently become a popular research topic in neuroscience, and many new algorithms have been applied to analyze brain networks. In particular, network topology measures from graph theory have been adapted to analyze network efficiency and 'small-world' properties. While there has been a surge in the number of papers examining connectivity through graph theory, questions remain about its test-retest reliability (TRT). In particular, the reproducibility of structural connectivity measures has not been assessed. We examined the TRT of global connectivity measures generated from graph theory analyses of 17 young adults who underwent two high-angular resolution diffusion (HARDI) scans approximately 3 months apart. Of the measures assessed, modularity had the highest TRT, and it was stable across a range of sparsities (a thresholding parameter used to define which network edges are retained). These reliability measures underline the need to develop network descriptors that are robust to acquisition parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of Electric Energy Storage (EES) integrated with Renewable Energy Resources (RER) has increased use of optimum scheduling strategy in distribution systems. Optimum scheduling of EES can reduce cost of purchased energy by retailers while improve the reliability of customers in distribution system. This paper proposes an optimum scheduling strategy for EES and the evaluation of its impact on reliability of distribution system. Case study shows the impact of the proposed strategy on reliability indices of a distribution system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research investigates how to obtain accurate and reliable positioning results with global navigation satellite systems (GNSS). The work provides a theoretical framework for reliability control in GNSS carrier phase ambiguity resolution, which is the key technique for precise GNSS positioning in centimetre levels. The proposed approach includes identification and exclusion procedures of unreliable solutions and hypothesis tests, allowing the reliability of solutions to be controlled in the aspects of mathematical models, integer estimation and ambiguity acceptance tests. Extensive experimental results with both simulation and observed data sets effectively demonstrate the reliability performance characteristics based on the proposed theoretical framework and procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Evaluation of scapular posture is an integral component of the clinical assessment of painful neck disorders. The aim of this study was to evaluate agreement between therapist judgements of scapula posture in multiple biomechanical planes in individuals with neck pain. Design Inter-therapist reliability study. Setting Research laboratory. Participants Fifteen participants with chronic neck pain. Main outcome measures Four physiotherapists recorded ratings of scapular orientation (relative to the thorax) in five different scapula postural planes (plane of scapula, sagittal plane, transverse plane, horizontal plane, and vertical plane) under four test conditions (at rest, and during three isometric shoulder conditions) in all participants. Inter-therapist reliability was expressed using both generalized and paired kappa coefficient. Results Following adjustment for expected agreement and the high prevalence of neutral ratings (81%), on average both the generalised kappa (0.37) as well as Cohen's Kappa for the two therapist pairs (0.45 and 0.42) demonstrated only slight to moderate inter-therapist reliability. Conclusions The findings suggest that ratings of scapular posture in individuals with neck pain by visual inspection has only slight to moderate reliability and should only be used in conjunction with other clinical tests when judging scapula function in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Simple Shoulder Test (SST-Sp) is a widely used outcome measure. Objective: The purpose of this study was to develop and validate a Spanish-version SST (SST-Sp). Methods: A two-stage observational study was conducted. The SST was initially cross-culturally adapted to Spanish through double forward and backward translation and then validated for its psychometric characteristics. Participants (n = 66) with several shoulder disorders completed the SST-Sp, DASH, VAS and SF-12. The full sample was employed to determine factor structure, internal consistency and concurrent criterion validity. Reliability was determined in the first 24–48 h in a subsample of 21 patients. Results: The SST-Sp showed three factors that explained the 56.1 % of variance, and the internal consistency for each factor was α = 0.738, 0.723 and 0.667, and reliability was ICC = 0.687–0.944. The factor structure was three-dimensional and supported construct validity. Criterion validity determined from the relationship between the SST-Sp and DASH was strong (r = −0.73; p < 0.001) and fair for VAS (r = −0.537; p < 0.001). Relationships between SST-Sp and SF-12 were weak for both physical (r = −0.47; p < 0.001) and mental (r = −0.43; p < 0.001) dimensions. Conclusions: The SST-Sp supports the findings of the original English version as being a valid shoulder outcome measure with similar psychometric properties to the original English version.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Palliative Care Problem Severity Score is a clinician-rated tool to assess problem severity in four palliative care domains (pain, other symptoms, psychological/spiritual, family/carer problems) using a 4-point categorical scale (absent, mild, moderate, severe). Aim To test the reliability and acceptability of the Palliative Care Problem Severity Score. Design: Multi-centre, cross-sectional study involving pairs of clinicians independently rating problem severity using the tool. Setting/participants Clinicians from 10 Australian palliative care services: 9 inpatient units and 1 mixed inpatient/community-based service. Results A total of 102 clinicians participated, with almost 600 paired assessments completed for each domain, involving 420 patients. A total of 91% of paired assessments were undertaken within 2 h. Strength of agreement for three of the four domains was moderate: pain (Kappa = 0.42, 95% confidence interval = 0.36 to 0.49); psychological/spiritual (Kappa = 0.48, 95% confidence interval = 0.42 to 0.54); family/carer (Kappa = 0.45, 95% confidence interval = 0.40 to 0.52). Strength of agreement for the remaining domain (other symptoms) was fair (Kappa = 0.38, 95% confidence interval = 0.32 to 0.45). Conclusion The Palliative Care Problem Severity Score is an acceptable measure, with moderate reliability across three domains. Variability in inter-rater reliability across sites and participant feedback indicate that ongoing education is required to ensure that clinicians understand the purpose of the tool and each of its domains. Raters familiar with the patient they were assessing found it easier to assign problem severity, but this did not improve inter-rater reliability.