228 resultados para Agreement Index (KAPPA)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Explosive ordnance disposal (EOD) often requires technicians to wear multiple protective garments in challenging environmental conditions. The accumulative effect of increased metabolic cost coupled with decreased heat dissipation associated with these garments predisposes technicians to high levels of physiological strain. It has been proposed that a perceptual strain index (PeSI) using subjective ratings of thermal sensation and perceived exertion as surrogate measures of core body temperature and heart rate, may provide an accurate estimation of physiological strain. Therefore, this study aimed to determine if the PeSI could estimate the physiological strain index (PSI) across a range of metabolic workloads and environments while wearing heavy EOD and chemical protective clothing. Methods Eleven healthy males wore an EOD and chemical protective ensemble while walking on a treadmill at 2.5, 4 and 5.5 km·h− 1 at 1% grade in environmental conditions equivalent to wet bulb globe temperature (WBGT) 21, 30 and 37 °C. WBGT conditions were randomly presented and a maximum of three randomised treadmill walking trials were completed in a single testing day. Trials were ceased at a maximum of 60-min or until the attainment of termination criteria. A Pearson's correlation coefficient, mixed linear model, absolute agreement and receiver operating characteristic (ROC) curves were used to determine the relationship between the PeSI and PSI. Results A significant moderate relationship between the PeSI and the PSI was observed [r = 0.77; p < 0.001; mean difference = 0.8 ± 1.1 a.u. (modified 95% limits of agreement − 1.3 to 3.0)]. The ROC curves indicated that the PeSI had a good predictive power when used with two, single-threshold cut-offs to differentiate between low and high levels of physiological strain (area under curve: PSI three cut-off = 0.936 and seven cut-off = 0.841). Conclusions These findings support the use of the PeSI for monitoring physiological strain while wearing EOD and chemical protective clothing. However, future research is needed to confirm the validity of the PeSI for active EOD technicians operating in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In response to the ratification of the United Nations Convention of the Rights of People with Disabilities (CRPD), Australian housing industry leaders, supported by the Australian Government, committed to transform their practices voluntarily through the adoption of a national guideline, called Livable Housing Design. They set a target in 2010 that all new housing would be visitable by 2020. Research in this area suggests that the anticipated voluntary transformation is unrealistic and that mandatory regulation will be necessary for any lasting transformation to occur. It also suggests that the assumptions underpinning the Livable Housing Design agreement are unfounded. This paper reports on a study that problematised these assumptions. The study used eleven newly-constructed dwellings in three housing contexts in Brisbane, Australia. It sought to understand the logics-of-practice in providing, and not providing, visitable housing. By examining the specific details that make a dwelling visitable, and interpreting the accounts of builders, designers and developers, the study identified three logics-of-practice which challenged the assumptions underpinning the Livable Housing Design agreement: focus on the point of sale; an aversion to change and deference to external regulators on matters of social inclusion. These were evident in all housing contexts indicating a dominant industry culture regardless of housing context or policy intention. The paper suggests that financial incentives for both the builder and the buyer, demonstration by industry leaders and, ultimately, national regulation is a possible pathway for the Livable Housing Design agreement to reach the 2020 goal. The paper concludes that the Australian Government has three options: to ignore its obligations under the CRPD; to revisit the Livable Housing Design agreement in the hope that it works; or to regulate the housing industry through the National Construction Code to ensure the 2020 target is reached.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Sphingosine-1-phosphate receptor 1 (S1P1) is crucial for regulation of immunity and bone metabolism. This study aimed to investigate the expression of S1P1 in rat periapical lesions and its relationship with receptor activator of nuclear factor kappa B ligand (RANKL) and regulatory T (Treg) cells. Methods Periapical lesions were induced by pulp exposure in the first lower molars of 55 Wistar rats. Thirty rats were killed on days 0, 7, 14, 21, 28, and 35, and their mandibles were harvested for x-ray imaging, micro–computed tomography scanning, histologic observation, immunohistochemistry, enzyme histochemistry, and double immunofluorescence analysis. The remaining 25 rats were killed on days 0, 14, 21, 28, and 35, and mandibles were harvested for flow cytometry. Results The volume and area of the periapical lesions increased from day 0 to day 21 and then remained comparably stable after day 28. S1P1-positive cells were observed in the inflammatory periapical regions; the number of S1P1-positive cells peaked at day 14 and then decreased from day 21 to day 35. The distribution of S1P1-positive cells was positively correlated with the dynamics of RANKL-positive cells but was negatively correlated with that of Treg cells. Conclusions S1P1 expression was differentially correlated with RANKL and Treg cell infiltration in the periapical lesions and is therefore a contributing factor to the pathogenesis of such lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heavy metal pollution of sediments is a growing concern in most parts of the world, and numerous studies focussed on identifying contaminated sediments by using a range of digestion methods and pollution indices to estimate sediment contamination have been described in the literature. The current work provides a critical review of the more commonly used sediment digestion methods and identifies that weak acid digestion is more likely to provide guidance on elements that are likely to be bioavailable than other traditional methods of digestion. This work also reviews common pollution indices and identifies the Nemerow Pollution Index as the most appropriate method for establishing overall sediment quality. Consequently, a modified Pollution Index that can lead to a more reliable understanding of whole sediment quality is proposed. This modified pollution index is then tested against a number of existing studies and demonstrated to give a reliable and rapid estimate of sediment contamination and quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a critical examination of the intellectual property sections of the Korea-Australia Free Trade Agreement 2014. Chapter 13 of the Korea-Australia Free Trade Agreement 2014 deals with the subject of intellectual property law. The Chapter covers such topics as the purposes and objectives of intellectual property law; copyright law; trade mark law; patent law; and intellectual property enforcement. The Joint Standing Committee on Treaties in the Australian Parliament highlighted the controversy surrounding this chapter of the agreement: The intellectual property rights chapter of KAFTA has drawn considerable attention from academics and stakeholders regarding the proposed need for changes to Australian intellectual property law and the inclusion of intellectual property in the definition of investment with regard to the investor-state dispute mechanism. Other concerns raised with the Committee include the prescriptive nature of the chapter, the lack of recognition of the broader public interests of intellectual property rights, and possible changes to fair use provisions. Article 13.1.1 of the Korea-Australia Free Trade Agreement 2014 provides that: ‘Each Party recognises the importance of adequate and effective protection of intellectual property rights, while ensuring that measures to enforce those rights do not themselves become barriers to legitimate trade.’ This is an unsatisfactory description of the objectives and purposes of intellectual property law in both Australia and Korea. There is a failure to properly consider the range of public purposes served by intellectual property law – such as providing for access to knowledge, promoting competition and innovation, protecting consumer rights, and allowing for the protection of public health, food security, and the environment. Such a statement of principles and objectives detracts from the declaration in the TRIPS Agreement 1994 of the public interest objectives to be served by intellectual property. Chapter 11 of the Korea-Australia Free Trade Agreement 2014 is an investment chapter, with an investor-state dispute settlement regime. This chapter is highly controversial – given the international debate over investor-state dispute settlement; the Australian context for the debate; and the text of the Korea-Australia Free Trade Agreement 2014. In April 2014, the United Nations Conference on Trade and Development (UNCTAD) released a report on Recent Developments in Investor-State Dispute Settlement. The overall figures are staggering. UNCTAD reports a significant growth in investment-state dispute settlement, across a wide array of different fields of public regulation. Given the broad definition of investment, intellectual property owners will be able to use the investor-state dispute settlement regime in the Korea-Australia Free Trade Agreement 2014. This will have significant implications for all the various disciplines of intellectual property – including copyright law, trade mark law, and patent law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The Neck Disability Index frequently is used to measure outcomes of the neck. The statistical rigor of the Neck Disability Index has been assessed with conflicting outcomes. To date, Confirmatory Factor Analysis of the Neck Disability Index has not been reported for a suitably large population study. Because the Neck Disability Index is not a condition-specific measure of neck function, initial Confirmatory Factor Analysis should consider problematic neck patients as a homogenous group. PURPOSE: We sought to analyze the factor structure of the Neck Disability Index through Confirmatory Factor Analysis in a symptomatic, homogeneous, neck population, with respect to pooled populations and gender subgroups. STUDY DESIGN: This was a secondary analysis of pooled data. PATIENT SAMPLE: A total of 1,278 symptomatic neck patients (67.5% female, median age 41 years), 803 nonspecific and 475 with whiplash-associated disorder. OUTCOME MEASURES: The Neck Disability Index was used to measure outcomes. METHODS: We analyzed pooled baseline data from six independent studies of patients with neck problems who completed Neck Disability Index questionnaires at baseline. The Confirmatory Factor Analysis was considered in three scenarios: the full sample and separate sexes. Models were compared empirically for best fit. RESULTS: Two-factor models have good psychometric properties across both the pooled and sex subgroups. However, according to these analyses, the one-factor solution is preferable from both a statistical perspective and parsimony. The two-factor model was close to significant for the male subgroup (p<.07) where questions separated into constructs of mental function (pain, reading headaches and concentration) and physical function (personal care, lifting, work, driving, sleep, and recreation). CONCLUSIONS: The Neck Disability Index demonstrated a one-factor structure when analyzed by Confirmatory Factor Analysis in a pooled, homogenous sample of neck problem patients. However, a two-factor model did approach significance for male subjects where questions separated into constructs of mental and physical function. Further investigations in different conditions, subgroup and sex-specific populations are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The purpose of this study was to adapt and validate the Foot Function Index to the Spanish (FFI-Sp) following the guidelines of the American Academy of Orthopaedic Surgeons. Methods A cross-sectional study 80 participants with some foot pathology. A statistical analysis was made, including a correlation study with other questionnaires (the Foot Health Status Questionnaire, EuroQol 5-D, Visual Analogue Pain Scale, and the Short Form SF-12 Health Survey). Data analysis included reliability, construct and criterion-related validity and factor analyses. Results The principal components analysis with varimax rotation produced 3 principal factors that explained 80% of the variance. The confirmatory factor analysis showed an acceptable fit with a comparative fit index of 0.78. The FFI-Sp demonstrated excellent internal consistency on the three subscales: pain 0.95; disability 0.96; and activity limitation 0.69, the subscale that scored lowest. The correlation between the FFI-Sp and the other questionnaires was high to moderate. Conclusions The Spanish version of the Foot Function Index (FFI-Sp) is a tool that is a valid and reliable tool with a very good internal consistency for use in the assessment of pain, disability and limitation of the function of the foot, for use both in clinic and research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We commend Swanenburg et al. (2013) on translation, development, and clinimetric analysis of the NDI-G. However, the dual-factor structure with factor analysis and the high level of internal consistency (IC) highlighted in their discussion were not emphasized in the abstract or conclusion. These points may imply some inconsistencies with the final conclusions since determination of stable point estimates with the study's small sample are exceedingly difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We usually find low levels of fitness condition affect other aspects of living for people with ID like dependency in carrying out activivities of daily living. Therefore we find high levels of dependency in activities of daily living due to poor fitness condition. The aim of the study is to explore the criterion validity of the Barthel index with a physical fitness test. An observational cross-sectional study was conducted. Data from the Barthel index and a physical fitness test were measured in 122 adults with intellectual disability. The data were analysed to find out the relationship between four categories of the physical fitness test and the Barthel index. It needs to be stressed that the correlations between the Barthel index and leg, abdominal and arm strength can confirm that these physical test are predictive of the Barthel index. The correlations between the balance variables as functional reach and single-leg stance with eyes open shown relationships with Barthel Index. We found important correlations between the physical fitness test and the Barthel index, so we can affirm that some physical fitness features are predictor variables of the Barthel index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modal flexibility is a widely accepted technique to detect structural damage using vibration characteristics. Its application to detect damage in long span large diameter cables such as those used in suspension bridge main cables has not received much attention. This paper uses the modal flexibility method incorporating two damage indices (DIs) based on lateral and vertical modes to localize damage in such cables. The competency of those DIs in damage detection is tested by the numerically obtained vibration characteristics of a suspended cable in both intact and damaged states. Three single damage cases and one multiple damage case are considered. The impact of random measurement noise in the modal data on the damage localization capability of these two DIs is next examined. Long span large diameter cables are characterized by the two critical cable parameters named bending stiffness and sag-extensibility. The influence of these parameters in the damage localization capability of the two DIs is evaluated by a parametric study with two single damage cases. Results confirm that the damage index based on lateral vibration modes has the ability to successfully detect and locate damage in suspended cables with 5% noise in modal data for a range of cable parameters. This simple approach therefore can be extended for timely damage detection in cables of suspension bridges and thereby enhance their service during their life spans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Concordance is characterised as a negotiation-like health communication approach based on an equal and collaborative partnership between patients and health professionals. The Leeds Attitudes to Concordance II (LATCon II) scale was developed to measure the attitudes towards concordance. The purpose of this study was to translate the LATCon II into Chinese and psychometrically test the Chinese version of LATCon II (C-LATCon II). Methods The study involved three phases: i) translation and cross-cultural adaptation; ii) pilot study, and; iii) a cross-sectional survey (n = 366). Systematic random sampling was used to recruit hypertensive patients from nine communities covering around 78,000 residents in China. Tests of psychometric properties included content validity, construct validity, criteria-related validity (correlation between the C-LATCon II and the Therapeutic Adherence Scale for Hypertensive Patients (TASHP)), internal reliability, and test-retest reliability (n = 30). Results The study found that the C-LATCon II had a satisfactory content validity (item-level Content Validity Index (CVI) = 0.83-1, scale-level CVI/universal agreement = 0.89, and scale-level CVI/averaging calculation = 0.98), construct validity (four components extracted explained 56.66% of the total variance), internal reliability (Cronbach’s alpha of overall scale and four components was 0.78 and 0.66-0.84, respectively), and test-retest reliability (Pearson’s correlation coefficient = 0.82, p < 0.001; interclass correlation coefficient = 0.82, p < 0.001; linear weighted kappa3 statistic for each item = 0.40-0.65, p < 0.05). Criteria-related validity showed a weak association (Pearson’s correlation coefficient = 0.11, p < 0.05) between patients’ attitudes towards concordance during health communication and their health behaviours for hypertension management. Conclusions The C-LATCon II is a validated and reliable instrument which can be used to evaluate the attitudes to concordance in Chinese populations. Four components (health professionals’ attitudes, partnership between two parties, therapeutic decision making, and patients’ involvement) describe the attitudes towards concordance during health communication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Index tracking is an investment approach where the primary objective is to keep portfolio return as close as possible to a target index without purchasing all index components. The main purpose is to minimize the tracking error between the returns of the selected portfolio and a benchmark. In this paper, quadratic as well as linear models are presented for minimizing the tracking error. The uncertainty is considered in the input data using a tractable robust framework that controls the level of conservatism while maintaining linearity. The linearity of the proposed robust optimization models allows a simple implementation of an ordinary optimization software package to find the optimal robust solution. The proposed model of this paper employs Morgan Stanley Capital International Index as the target index and the results are reported for six national indices including Japan, the USA, the UK, Germany, Switzerland and France. The performance of the proposed models is evaluated using several financial criteria e.g. information ratio, market ratio, Sharpe ratio and Treynor ratio. The preliminary results demonstrate that the proposed model lowers the amount of tracking error while raising values of portfolio performance measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soundscape assessment has been proposed as a remote ecological monitoring tool for measuring biodiversity, but few studies have examined how soundscape patterns vary with landscape configuration and condition. The goal of our study was to examine a suite of published acoustic indices to determine whether they provide comparable results relative to varying levels of landscape fragmentation and ecological condition in nineteen forest sites in eastern Australia. Our comparison of six acoustic indices according to time of day revealed that two indices, the acoustic complexity and the bioacoustic index, presented a similar pattern that was linked to avian song intensity, but was not related to landscape and biodiversity attributes. The diversity indices, acoustic entropy and acoustic diversity, and the normalized difference soundscape index revealed high nighttime sound, as well as a dawn and dusk chorus. These indices appear to be sensitive to nocturnal biodiversity which is abundant at night in warm, subtropical environments. We argue that there is need to better understand temporal partitioning of the soundscape by specific taxonomic groups, and this should involve integrated research on amphibians, insects and birds during a 24 h cycle. The three indices that best connected the soundscape with landscape characteristics, ecological condition and bird species richness were acoustic entropy, acoustic evenness and the normalized difference soundscape index. This study has demonstrated that remote soundscape assessment can be implemented as an ecological monitoring tool in fragmented Australian forest landscapes. However, further investigation should be dedicated to refining and/or combining existing acoustic indices and also to determine if these indices are appropriate in other landscapes and for other survey purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article considers the race to sequence the Severe Acute Respiratory Syndrome virus ('the SARS virus') in light of the debate over patent law and access to essential medicines. Part II evaluates the claims of public research institutions in Canada, the United States, and Hong Kong, and commercial companies, to patent rights in respect of the SARS virus. It highlights the dilemma of ’defensive patenting' - the tension between securing private patent rights and facilitating public disclosure of information and research. Part III considers the race to patent the SARS virus in light of wider policy debates over gene patents. It examines the application of such patent criteria as novelty, inventive step, utility, and secret use. It contends that there is a need to reform the patent system to accommodate the global nature of scientific inquiry, the unique nature of genetics, and the pace of technological change. Part IV examines the role played by the World Trade Organization and the World Health Organization in dealing with patent law and access to essential medicines. The article contends that there is a need to ensure that the patent system is sufficiently flexible and adaptable to accommodate international research efforts on infectious diseases.