213 resultados para reliability test system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper an approach is presented for identification of a reduced model for coherent areas in power systems using phasor measurement units to represent the inter-area oscillations of the system. The generators which are coherent in a wide range of operating conditions form the areas in power systems and the reduced model is obtained by representing each area by an equivalent machine. The reduced nonlinear model is then identified based on the data obtained from measurement units. The simulation is performed on three test systems and the obtained results show high accuracy of identification process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new method to determine feeder reconfiguration scheme considering variable load profile. The objective function consists of system losses, reliability costs and also switching costs. In order to achieve an optimal solution the proposed method compares these costs dynamically and determines when and how it is reasonable to have a switching operation. The proposed method divides a year into several equal time periods, then using particle swarm optimization (PSO), optimal candidate configurations for each period are obtained. System losses and customer interruption cost of each configuration during each period is also calculated. Then, considering switching cost from a configuration to another one, dynamic programming algorithm (DPA) is used to determine the annual reconfiguration scheme. Several test systems were used to validate the proposed method. The obtained results denote that to have an optimum solution it is necessary to compare operation costs dynamically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organizational learning has been studied as a key factor in firm performance and internationalization. Moving beyond the past emphasis on market learning, we develop a more complete explanation of learning, its relationship to innovation, and their joint effect on early internationalization. We theorize that, driven by the founders’ international vision, early internationalizing firms employ a dual subsystem of dynamic capabilities: a market subsystem consisting of market-focused learning capability and marketing capability, and a socio-technical subsystem comprised of network learning capability and internally focused learning capability. We argue that innovation mediates the proposed relationship between the dynamic capability structure and early internationalization. We conduct case studies to develop the conceptual framework and test it in a field survey of early internationalizing firms from Australia and the United States. Our findings indicate a complex interplay of capabilities driving innovation and early internationalization. We provide theoretical and practical implications and offer insights for future research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The standard method of labelling proliferating cells uses the thymidine analogue, bromodeoxyuridine (BrdU), which incorporates into the DNA during S-phase of the cell cycle. A disadvantage of this method is that the immunochemical processing requires pre-treatment of the cells and tissue with heat or acid to reveal the antigen. This pre-treatment reduces reliability of the method and degrades the specimen, reducing the ability for multiple immuno-fluorescence labelling at high resolution. We report here the utility of a novel thymidine analogue, ethynyl deoxyuridine (EdU), detected with a fluorescent azide via the “click” chemistry reaction (the Huisgen 1,3-dipolar cycloaddition reaction of an organic azide to a terminal acetylene). The detection of EdU requires no heat or acid treatment and the incorporated EdU is covalently conjugated to fluorescent probe. The reaction is quick and compatible with fluorescence immunochemistry and other fluorescent probes. We show here that EdU is non-toxic in vitro and in vivo and can be used in place of BrdU to label cells during neurogenesis and the progeny identified at least 30 days later. The fluorescent labelling of EdU, markedly improves the detection of proliferating cells and allows concurrent high resolution fluorescence immunochemistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since 1992 there have been several articles published on research on plastic scintillators for use in radiotherapy. Plastic scintillators are said to be tissue equivalent, temperature independent and dose rate independent [1]. Although their properties were found to be promising for measurements in megavoltage X-ray beams there were some technical difficulties with regards to its commercialisation. Standard Imaging has produced the first commercial system which is now available for use in a clinical setting. The Exradin W1 scintillator device uses a dual fibre system where one fibre is connected to the Plastic Scintillator and the other fibre only measures Cerenkov radiation [2]. This paper presents results obtained during commissioning of this dosimeter system. Methods All tests were performed on a Novalis Tx linear accelerator equipped with a 6 MV SRS photon beam and conventional 6 and 18 MV X-ray beams. The following measurements were performed in a Virtual Water phantom at a depth of dose maximum. Linearity: The dose delivered was varied between 0.2 and 3.0 Gy for the same field conditions. Dose rate dependence: For this test the repetition rate of the linac was varied between 100 and 1,000 MU/min. A nominal dose of 1.0 Gy was delivered for each rate. Reproducibility: A total of five irradiations for the same setup. Results The W1 detector gave a highly linear relationship between dose and the number of Monitor Units delivered for a 10 9 10 cm2 field size at a SSD of 100 cm. The linearity was within 1 % for the high dose end and about 2 % for the very low dose end. For the dose rate dependence, the dose measured as a function of repetition the rate (100–1,000 MU/min) gave a maximum deviation of 0.9 %. The reproducibility was found to be better than 0.5 %. Discussion and conclusions The results for this system look promising so far being a new dosimetry system available for clinical use. However, further investigation is needed to produce a full characterisation prior to use in megavoltage X-ray beams.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the validity and inter-rater reliability of the Observation System for Recording Activity in Children: Youth Sports (OSRAC:YS). Children (N=29) participating in a parks and recreation soccer program were observed during regularly scheduled practices. Physical activity (PA) intensity and contextual factors were recorded by momentary time-sampling procedures (10-sec observe, 20-sec record). Two observers simultaneously observed and recorded children's PA intensity, practice context, social context, coach behavior, and coach proximity. Inter-rater reliability was based on agreement (Kappa) between the observer's coding for each category, and the Intraclass Correlation Coefficient (ICC) for percent of time spent in MVPA. Validity was assessed by calculating the correlation between OSRAC:YS estimated and objectively measured MVPA. Kappa statistics for each category demonstrated substantial to almost perfect inter-observer agreement (Κappa = 0.67 to 0.93). The ICC for percent time in MVPA was 0.76 (95% C.I. = 0.49 - 0.90). A significant correlation (r = 0.73) was observed for MVPA recorded by observation and MVPA measured via accelerometry. The results indicate the OSRAC:YS is a reliable and valid tool for measuring children's PA and contextual factors during a youth soccer practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine the reliability and validity of field tests for assessing physical function in mid-aged and young-old people (55-70 y). Tests were selected that required minimal space and equipment and could be implemented in multiple field settings such as a general practitioner's office. Nineteen participants completed 2 field and I laboratory testing sessions. Intra-class correlations showed good reliability for the tests of upper body strength (lift and reach, R=.66), lower body strength (sit to stand, R=.80) and functional capacity (Canadian Step Test, R=.92), but not for leg power (single timed chair rise, R=.28). There was also good reliability for the balance test during 3 stances: parallel (94.7% agreement), semi-tandem (73.7%), and tandem (52.6%). Comparison of field test results with objective laboratory measures found good validity for the sit to stand (cf 1RM leg press, Pearson r=.68, p <.05), and for the step test (cf PWC140, r = -.60, p <.001), but not for the lift and reach (cf 1RM bench press, r=.43, p >.05), balance (r=-.13, -.18, .23) and rate of force development tests (r=-.28). It was concluded that the lower body strength and cardiovascular function tests were appropriate for use in field settings with mid-aged and young-old adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many countries conduct regular national time use surveys, some of which date back as far as the 1960s. Time use surveys potentially provide more detailed and accurate national estimates of the prevalence of sedentary and physical activity behavior than more traditional self-report surveillance systems. In this study, the authors determined the reliability and validity of time use surveys for assessing sedentary and physical activity behavior. In 2006 and 2007, participants (n = 134) were recruited from work sites in the Australian state of New South Wales. Participants completed a 2-day time use diary twice, 7 days apart, and wore an accelerometer. The 2 diaries were compared for test-retest reliability, and comparison with the accelerometer determined concurrent validity. Participants with similar activity patterns during the 2 diary periods showed reliability intraclass correlations of 0.74 and 0.73 for nonoccupational sedentary behavior and moderate/vigorous physical activity, respectively. Comparison of the diary with the accelerometer showed Spearman correlations of 0.57-0.59 and 0.45-0.69 for nonoccupational sedentary behavior and moderate/vigorous physical activity, respectively. Time use surveys appear to be more valid for population surveillance of nonoccupational sedentary behavior and health-enhancing physical activity than more traditional surveillance systems. National time use surveys could be used to retrospectively study nonoccupational sedentary and physical activity behavior over the past 5 decades.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is debated that for sustainable STEM education and knowledge investment, human centered learning design approach is critical and important. Sustainability in this context is enduring maintenance of technological trajectories for productive economical and social interactions by demonstrating life critical scenarios through life critical system development and life experiences. Technology influences way of life and the learning and teaching process. Social software application development is more than learning of how to program a software application and extracting information from the Internet. Hence, our research challenge is, how do we attract learners to STEM social software application development? Our realisation processes begin with comparing Science and Technology education in developed (e.g., Australia) and developing (e.g., Sri Lanka) countries with distinction on final year undergraduates’ industry ready training programmes. Principal components analysis was performed to separate patterns of important factors. To measure behavioural intention of perceived usefulness and attitudes of the training, the measurement model was analysed to test its validity and reliability using partial least square (PLS) analysis of structural equation modelling (SEM). Our observation is that the relationship is more complex than we argue for. Our initial conclusions were that life critical system development and life experience trajectories as determinant factors while technological influences were unavoidable. A further investigation should involve correlations between human centered learning design approach and economical development in the long run.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article presents the field applications and validations for the controlled Monte Carlo data generation scheme. This scheme was previously derived to assist the Mahalanobis squared distance–based damage identification method to cope with data-shortage problems which often cause inadequate data multinormality and unreliable identification outcome. To do so, real-vibration datasets from two actual civil engineering structures with such data (and identification) problems are selected as the test objects which are then shown to be in need of enhancement to consolidate their conditions. By utilizing the robust probability measures of the data condition indices in controlled Monte Carlo data generation and statistical sensitivity analysis of the Mahalanobis squared distance computational system, well-conditioned synthetic data generated by an optimal controlled Monte Carlo data generation configurations can be unbiasedly evaluated against those generated by other set-ups and against the original data. The analysis results reconfirm that controlled Monte Carlo data generation is able to overcome the shortage of observations, improve the data multinormality and enhance the reliability of the Mahalanobis squared distance–based damage identification method particularly with respect to false-positive errors. The results also highlight the dynamic structure of controlled Monte Carlo data generation that makes this scheme well adaptive to any type of input data with any (original) distributional condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The wellness construct has application in a number of fields including education, healthcare and counseling, particularly with regard to female adolescents. The effective measurement of wellness in adolescents can assist researchers and practitioners in determining lifestyle behaviors in which they are lacking. Behavior change interventions can then be designed which directly aid in the promotion of these areas. Methods The 5-Factor Wellness Inventory (designed to measure the Indivisible Self model of wellness) is a popular instrument for measuring the broad aspects of wellness amongst adolescents. The instrument comprises 97 items contributing to 17 subscales, five dimension scores, four context scores, total wellness score, and a life satisfaction index. This investigation evaluated the test-retest (intra-rater) reliability of the 5 F-Wel instrument in repeated assessments (seven days apart) among adolescent females aged 12-14 years. Percentages of exact agreement for individual items, and the number of respondents who scored within +/-5, +/-7.5 and +/-10 points for total wellness and the five summary dimension scores were calculated. Results Overall, 46 (95.8%) participants responded with complete data and were included in the analysis. Item agreement ranged from 47.8% to 100% across the 97 items (median 69.9%, interquartile range 60.9%-73.9%). The percentage of respondents who scored within +/-5, +/-7.5 and +/-10 points for total wellness at the re-assessment was 87.0%, 97.8% and 97.8% respectively. The percentage of respondents who scored within +/-5, +/-7.5 and +/-10 for the domain scores at the reassessment ranged between 54.3-76.1%, 78.3-95.7% and 89.1-95.7% respectively across the five dimensions. Conclusions These findings suggest there was considerable variation in agreement between the two assessments on some individual items. However, the total wellness score and the five dimension summary scores remained comparatively stable between assessments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring of the integrity of rolling element bearings in the traction system of high speed trains is a fundamental operation in order to avoid catastrophic failures and to implement effective condition-based maintenance strategies. Diagnostics of rolling element bearings is usually based on vibration signal analysis by means of suitable signal processing techniques. The experimental validation of such techniques has been traditionally performed by means of laboratory tests on artificially damaged bearings, while their actual effectiveness in industrial applications, particularly in the field of rail transport, remains scarcely investigated. This paper will address the diagnostics of bearings taken from the service after a long term operation on a high speed train. These worn bearings have been installed on a test-rig, consisting of a complete full-scale traction system of a high speed train, able to reproduce the effects of wheel-track interaction and bogie-wheelset dynamics. The results of the experimental campaign show that suitable signal processing techniques are able to diagnose bearing failures even in this harsh and noisy application. Moreover, the most suitable location of the sensors on the traction system is also proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rolling element bearings are the most critical components in the traction system of high speed trains. Monitoring their integrity is a fundamental operation in order to avoid catastrophic failures and to implement effective condition based maintenance strategies. Generally, diagnostics of rolling element bearings is usually performed by analyzing vibration signals measured by accelerometers placed in the proximity of the bearing under investigation. Several papers have been published on this subject in the last two decades, mainly devoted to the development and assessment of signal processing techniques for diagnostics. The experimental validation of such techniques has been traditionally performed by means of laboratory tests on artificially damaged bearings, while their actual effectiveness in specific industrial applications, particularly in rail industry, remains scarcely investigated. This paper is aimed at filling this knowledge gap, by addressing the diagnostics of bearings taken from the service after a long term operation on the traction system of a high speed train. Moreover, in order to test the effectiveness of the diagnostic procedures in the environmental conditions peculiar to the rail application, a specific test-rig has been built, consisting of a complete full-scale train traction system, able to reproduce the effects of wheeltrack interaction and bogie-wheelset dynamics. The results of the experimental campaign show that suitable signal processing techniques are able to diagnose bearing failures even in this harsh and noisy application. Moreover, the most suitable location of the sensors on the traction system is proposed, in order to limit their number.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Parental fever phobia and overuse of antipyretics to control fever is increasing. Little is known about childhood fever management among Arab parents. No scales to measure parents’ fever management practices in Palestine are available. Aims The aims of this study were to translate and examine the psychometric properties of the Arabic version of the Parent Fever Management Scale (PFMS). Methods A standard “forward–backward” procedure was used to translate PFMS into Arabic language. It was then validated on a convenience sample of 402 parents between July and October 2012. Descriptive statistics were used, and instrument reliability was assessed for internal consistency using Cronbach's alpha coefficient. Validity was confirmed using convergent and known group validation. Results Applying the recommended scoring method, the median (interquartile range) score of the PFMS was 26 (23-30). Acceptable internal consistency was found (Cronbach’s alpha = 0.733) and the test–retest reliability value was 0.92 (P < 0.001). The chi-squared (χ2) test showed a significant relationship between PFMS groups and frequent daily administration of antipyretic groups (χ2 = 52.86; P < 0.001). The PFMS sensitivity and specificity were 77.67% and 57.75%, respectively. The positive and negative predictive values were 67.89% and 32.11%, respectively. Conclusions The findings of this validation study indicate that the Arabic version of the PFMS is a reliable and valid measure which can be used as a useful tool for health professionals to identify parents’ fever management practices and thus provide targeted education to reduce the unnecessary burden of care they place on themselves when concerned for a febrile child.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) affects the central vision and subsequently may lead to visual loss in people over 60 years of age. There is no permanent cure for AMD, but early detection and successive treatment may improve the visual acuity. AMD is mainly classified into dry and wet type; however, dry AMD is more common in aging population. AMD is characterized by drusen, yellow pigmentation, and neovascularization. These lesions are examined through visual inspection of retinal fundus images by ophthalmologists. It is laborious, time-consuming, and resource-intensive. Hence, in this study, we have proposed an automated AMD detection system using discrete wavelet transform (DWT) and feature ranking strategies. The first four-order statistical moments (mean, variance, skewness, and kurtosis), energy, entropy, and Gini index-based features are extracted from DWT coefficients. We have used five (t test, Kullback–Lieber Divergence (KLD), Chernoff Bound and Bhattacharyya Distance, receiver operating characteristics curve-based, and Wilcoxon) feature ranking strategies to identify optimal feature set. A set of supervised classifiers namely support vector machine (SVM), decision tree, k -nearest neighbor ( k -NN), Naive Bayes, and probabilistic neural network were used to evaluate the highest performance measure using minimum number of features in classifying normal and dry AMD classes. The proposed framework obtained an average accuracy of 93.70 %, sensitivity of 91.11 %, and specificity of 96.30 % using KLD ranking and SVM classifier. We have also formulated an AMD Risk Index using selected features to classify the normal and dry AMD classes using one number. The proposed system can be used to assist the clinicians and also for mass AMD screening programs.