165 resultados para respondent validation
Resumo:
Background Patient-relevant outcome measures are essential for high-quality clinical research, and quality-of-life (QoL) tools are the current standard. Currently, there is no validated children's acute cough-specific QoL questionnaire. Objective The objective of this study was to develop and validate the Parent-proxy Children's Acute Cough-specific QoL Questionnaire (PAC-QoL). Methods Using focus groups, a 48-item PAC-QoL questionnaire was developed and later reduced to 16 items by using the clinical impact method. Parents of children with a current acute cough (<2 weeks) at enrollment completed 2 validated cough score measures, the preliminary 48-item PAC-QoL, and 3 other questionnaires (the State Trait Anxiety Inventory [STAI], the Short-Form 8-item 24-hour recall Health Survey [SF-8], and the Depression, Anxiety, and Stress 21-item Scale [DASS21]). All measures were repeated on days 3 and 14. Results The median age of the 155 children enrolled was 2.3 years (interquartile range, 1.3-4.6). Median cough duration at enrollment was 3 days (interquartile range, 2-5). The reduced 16-item scale had high internal consistency (Cronbach α = 0.95). Evidence for repeatability and criterion validity was shown by significant correlations between the domains and total PAC-QoL scores and the SF-8 (r = −0.36 and −0.51), STAI (r = −0.27 and −0.39), and DASS21 (r = −0.32 and −0.41) scales on days 0 and 3, respectively. The final PAC-QoL questionnaire was sensitive to change over time, with changes significantly relating to changes in cough score measures (P < .001). Conclusion The 16-item PAC-QoL is a reliable and valid outcome measure that assesses QoL related to childhood acute cough at a given time point and reflects changes in acute cough-specific QoL over time.
Resumo:
This study reported on the validation of the psychometric properties, the factorability, validity, and sensitivity of the Dysexecutive Questionnaire (DEX) in 3 clinical and nonclinical samples. A mixed sample of 997 participants—community (n = 663), psychiatric (depressed [n = 92] and anxious [n = 122]), and neurologically impaired (n = 120)—completed self-report questionnaires assessing executive dysfunction, depression, anxiety, stress, general self-efficacy, and satisfaction with life. Before analyses the data were randomly split into 2 subsets (A and B). Exploratory factor analysis performed on Subset A produced a 3-factor model (Factor 1: Inhibition, Factor 2: Volition, and Factor 3: Social Regulation) in which 15 of the original 20 items provided a revised factor structure that was superior to all other structures. A series of confirmatory factor analyses performed on Subset B confirmed that this revised factor structure was valid and reliable. The revised structure, labeled the DEX-R, was found to be a reliable and valid tool for assessing behavioral symptoms of dysexecutive functioning in mixed community, psychiatric, and neurological samples.
Resumo:
Background No tool exists to measure self-efficacy for overcoming lymphedema-related exercise barriers in individuals with cancer-related lymphedema. However, an existing scale measures confidence to overcome general exercise barriers in cancer survivors. Therefore, the purpose of this study was to develop, validate and assess the reliability of a subscale, to be used in conjunction with the general barriers scale, for determining exercise barriers self-efficacy in individuals facing lymphedema-related exercise barriers. Methods A lymphedema-specific exercise barriers self-efficacy subscale was developed and validated using a cohort of 106 cancer survivors with cancer-related lymphedema, from Brisbane, Australia. An initial ten-item lymphedema-specific barrier subscale was developed and tested, with participant feedback and principal components analysis results used to guide development of the final version. Validity and test-retest reliability analyses were conducted on the final subscale. Results The final lymphedema-specific subscale contained five items. Principal components analysis revealed these items loaded highly (> 0.75) on a separate factor when tested with a well-established nine-item general barriers scale. The final five-item subscale demonstrated good construct and criterion validity, high internal consistency (Cronbach’s alpha=0.93) and test-retest reliability (ICC=0.67, p< 0.01). Conclusions A valid and reliable lymphedema-specific subscale has been developed to assess exercise barriers self-efficacy in individuals with cancer-related lymphedema. This scale can be used in conjunction with an existing general exercise barriers scale to enhance exercise adherence in this understudied patient group.
Resumo:
Abstract Background The purpose of this study was the development of a valid and reliable “Mechanical and Inflammatory Low Back Pain Index” (MIL) for assessment of non-specific low back pain (NSLBP). This 7-item tool assists practitioners in determining whether symptoms are predominantly mechanical or inflammatory. Methods Participants (n = 170, 96 females, age = 38 ± 14 years-old) with NSLP were referred to two Spanish physiotherapy clinics and completed the MIL and the following measures: the Roland Morris Questionnaire (RMQ), SF-12 and “Backache Index” (BAI) physical assessment test. For test-retest reliability, 37 consecutive patients were assessed at baseline and three days later during a non-treatment period. Face and content validity, practical characteristics, factor analysis, internal consistency, discriminant validity and convergent validity were assessed from the full sample. Results A total of 27 potential items that had been identified for inclusion were subsequently reduced to 11 by an expert panel. Four items were then removed due to cross-loading under confirmatory factor analysis where a two-factor model yielded a good fit to the data (χ2 = 14.80, df = 13, p = 0.37, CFI = 0.98, and RMSEA = 0.029). The internal consistency was moderate (α = 0.68 for MLBP; 0.72 for ILBP), test-retest reliability high (ICC = 0.91; 95%CI = 0.88-0.93) and discriminant validity good for either MLBP (AUC = 0.74) and ILBP (AUC = 0.92). Convergent validity was demonstrated through similar but weak correlations between the ILBP and both the RMQ and BAI (r = 0.34, p < 0.001) and the MLBP and BAI (r = 0.38, p < 0.001). Conclusions The MIL is a valid and reliable clinical tool for patients with NSLBP that discriminates between mechanical and inflammatory LBP. Keywords: Low back pain; Psychometrics properties; Pain measurement; Screening tool; Inflammatory; Mechanical
Resumo:
Self-gifting consumer behaviour (SGCB) is on the rise as consumers seek reward and therapeutic benefits from their shopping experiences. SGCB is defined as personally symbolic, self-communication through special indulgences, which tend to be premeditated and highly context bound. Prior research into the measurement of this growing behavioural phenomenon has been fragmented because of differences in conceptualisation. This research builds upon the prior literature and through a series of qualitative and quantitative studies, develops a valid, multidimensional measure of SGCB that will be useful for future quantitative inquiry into self-gifting consumption.
Resumo:
The competent leadership and governance of digital transformation needs to involve the board of directors. The reported lack of such capability in boards is becoming a pressing issue. Underpinning leadership in such transformation are the competencies to effectively govern Enterprise Technology (ETG). In this paper we take the position that ETG competencies are essential in boards because competent enterprise business technology governance has been shown to contribute to increased revenue, profit, and returns. We report the industry validation processes of a set of three board-of-director competencies needed for effective ETG related to strategy and planning; investment and risk; and, innovation and value creation. We conclude that gaps in board ETG competence remain.
Resumo:
Background The purpose of this study was to adapt and validate the Foot Function Index to the Spanish (FFI-Sp) following the guidelines of the American Academy of Orthopaedic Surgeons. Methods A cross-sectional study 80 participants with some foot pathology. A statistical analysis was made, including a correlation study with other questionnaires (the Foot Health Status Questionnaire, EuroQol 5-D, Visual Analogue Pain Scale, and the Short Form SF-12 Health Survey). Data analysis included reliability, construct and criterion-related validity and factor analyses. Results The principal components analysis with varimax rotation produced 3 principal factors that explained 80% of the variance. The confirmatory factor analysis showed an acceptable fit with a comparative fit index of 0.78. The FFI-Sp demonstrated excellent internal consistency on the three subscales: pain 0.95; disability 0.96; and activity limitation 0.69, the subscale that scored lowest. The correlation between the FFI-Sp and the other questionnaires was high to moderate. Conclusions The Spanish version of the Foot Function Index (FFI-Sp) is a tool that is a valid and reliable tool with a very good internal consistency for use in the assessment of pain, disability and limitation of the function of the foot, for use both in clinic and research.
Resumo:
In this paper, we detail the development of two stakeholder relationships scales. The scales measure major project managers' perceived competence in developing (establishing and maintaining) high quality, effective relationships with stakeholders who are internal and external to their organization. Our sample consists of 373 major project managers from a sub-set of the Australian defense industry. Both the internal stakeholder relationships scale and the external stakeholder relationships scale demonstrated validity and reliability. This research has implications for the interpersonal work relationships literature and the stakeholder management literature. We recommend that researchers test these scales with multiple samples, across different project types and project industries in the future. The stakeholder relationship scales should be versatile enough to be applied to project management generally but are perhaps best suited to major project environments.
Resumo:
Background Australia has commenced public reporting and benchmarking of healthcare associated infections (HAIs), despite not having a standardised national HAI surveillance program. Annual hospital Staphylococcus aureus bloodstream (SAB) infection rates are released online, with other HAIs likely to be reported in the future. Although there are known differences between hospitals in Australian HAI surveillance programs, the effect of these differences on reported HAI rates is not known. Objective To measure the agreement in HAI identification, classification, and calculation of HAI rates, and investigate the influence of differences amongst those undertaking surveillance on these outcomes. Methods A cross-sectional online survey exploring HAI surveillance practices was administered to infection prevention nurses who undertake HAI surveillance. Seven clinical vignettes describing HAI scenarios were included to measure agreement in HAI identification, classification, and calculation of HAI rates. Data on characteristics of respondents was also collected. Three of the vignettes were related to surgical site infection and four to bloodstream infection. Agreement levels for each of the vignettes were calculated. Using the Australian SAB definition, and the National Health and Safety Network definitions for other HAIs, we looked for an association between the proportion of correct answers and the respondents’ characteristics. Results Ninety-two infection prevention nurses responded to the vignettes. One vignette demonstrated 100 % agreement from responders, whilst agreement for the other vignettes varied from 53 to 75 %. Working in a hospital with more than 400 beds, working in a team, and State or Territory was associated with a correct response for two of the vignettes. Those trained in surveillance were more commonly associated with a correct response, whilst those working part-time were less likely to respond correctly. Conclusion These findings reveal the need for further HAI surveillance support for those working part-time and in smaller facilities. It also confirms the need to improve uniformity of HAI surveillance across Australian hospitals, and raises questions on the validity of the current comparing of national HAI SAB rates.
Resumo:
Background: The Simple Shoulder Test (SST-Sp) is a widely used outcome measure. Objective: The purpose of this study was to develop and validate a Spanish-version SST (SST-Sp). Methods: A two-stage observational study was conducted. The SST was initially cross-culturally adapted to Spanish through double forward and backward translation and then validated for its psychometric characteristics. Participants (n = 66) with several shoulder disorders completed the SST-Sp, DASH, VAS and SF-12. The full sample was employed to determine factor structure, internal consistency and concurrent criterion validity. Reliability was determined in the first 24–48 h in a subsample of 21 patients. Results: The SST-Sp showed three factors that explained the 56.1 % of variance, and the internal consistency for each factor was α = 0.738, 0.723 and 0.667, and reliability was ICC = 0.687–0.944. The factor structure was three-dimensional and supported construct validity. Criterion validity determined from the relationship between the SST-Sp and DASH was strong (r = −0.73; p < 0.001) and fair for VAS (r = −0.537; p < 0.001). Relationships between SST-Sp and SF-12 were weak for both physical (r = −0.47; p < 0.001) and mental (r = −0.43; p < 0.001) dimensions. Conclusions: The SST-Sp supports the findings of the original English version as being a valid shoulder outcome measure with similar psychometric properties to the original English version.
Resumo:
Background: Recently there have been efforts to derive safe, efficient processes to rule out acute coronary syndrome (ACS) in emergency department (ED) chest pain patients. We aimed to prospectively validate an ACS assessment pathway (the 2-Hour Accelerated Diagnostic Protocol to Assess Patients with Chest Pain Symptoms Using Contemporary Troponins as the Only Biomarker (ADAPT) pathway) under pragmatic ED working conditions. Methods: This prospective cohort study included patients with atraumatic chest pain in whom ACS was suspected but who did not have clear evidence of ischaemia on ECG. Thrombolysis in myocardial infarction (TIMI) score and troponin (TnI Ultra) were measured at ED presentation, 2 h later and according to current national recommendations. The primary outcome of interest was the occurrence of major adverse cardiac events (MACE) including prevalent myocardial infarction (MI) at 30 days in the group who had a TIMI score of 0 and had presentation and 2-h TnI assays <99th percentile. Results: Eight hundred and forty patients were studied of whom 177 (21%) had a TIMI score of 0. There were no MI, MACE or revascularization in the per protocol and intention-to-treat 2-h troponin groups (0%, 95% confidence interval (CI) 0% to 4.5% and 0%, 95% CI 0% to 3.8%, respectively). The negative predictive value (NPV) was 100% (95% CI 95.5% to 100%) and 100% (95% CI 96.2% to 100%), respectively. Conclusions: A 2-h accelerated rule-out process for ED chest pain patients using electrocardiography, a TIMI score of 0 and a contemporary sensitive troponin assay accurately identifies a group at very low risk of 30-day MI or MACE.