148 resultados para bi-polar disorder
Resumo:
"When Susannah Birch was two years old her mother cut her throat, in a ritual sacrifice, Susannah was very lucky to survive. This was the first of her mother’s psychotic episodes as she enacted a passage from The Old Testament...In this moving documentary Susannah and her father describe their memories of this shocking event and how it has affected them."--publisher website
Resumo:
Intersex is the condition whereby an individual is born with biological features that are simultaneously perceived as male and female. Ranging from the ambiguous genitalia of the true 'hermaphrodite' to the 'mildly or internally intersexed', the condition may be as common as cleft palate. Like cleft palate, it is hidden and surgically altered, but for very different reasons. Intersex draws heavily on the personal testimony of intersexed individuals, their loved ones and medical carers. The impact of early sex-assignment surgery on an individual's later life is examined within the context of ethical and clinical questions. Harper challenges the conventional and radical 'treatment' of intersexuality through non-consensual infant sex-assignment surgery. In doing so, she exposes powerful myths, taboos and constructions of gender - the perfect phallus, a bi-polar model of gender and the infallibility of medical decisions. Handling sensitive material with care, this book deepens our understanding of a condition that has itself only been medically understood in recent years.
Resumo:
The shortage of donor hearts for patients with end stage heart failure has accelerated the development of ventricular assist devices (VAD) that act as a replacement heart. Mechanical devices involving pulsatile, axial and centrifugal devices have been proposed. Recent clinical developments indicate that centrifugal devices are not only beneficial for bridge to transplantation applications, but may also aid myocardial recovery. The results of a recent study have shown that patients who received a VAD have extended lives and improved quality of life compared to recipients of drug therapy. Unfortunately 25% of these patients develop right heart failure syndrome, sepsis and multi-organ failure. It was reported that 17% of patients initially receiving an LVAD later required a right ventricular assist device (RVAD). Hence, current research focus is in the development of a bi-ventricular assist device (BVAD). Current BVAD technology is either too bulky or necessitates having to implant two pumps working independently. The latter requires two different controllers for each pump leading to the potential complication of uneven flow dynamics and the requirements for a large amount of body space. This paper illustrates the combination of the LVAD and RVAD as one complete device to augment the function of both the left and right cardiac chambers with double impellers. The proposed device has two impellers rotating in counter directions, hence eliminating the necessity of the body muscles and tubing/heart connection to restrain the pump. The device will also have two separate chambers with independent rotating impeller for the left and right chambers. A problem with centrifugal impellers is the fluid stagnation underneath the impeller. This leads to thrombosis and blood clots.This paper presents the design, construction and location of washout hole to prevent thrombus for a Bi-VAD centrifugal pump. Results using CFD will be used to illustrate the superiority of our design concept in terms of preventing thrombus formation and hemolysis.
Resumo:
For the last two decades heart disease has been the highest single cause of death for the human population. With an alarming number of patients requiring heart transplant, and donations not able to satisfy the demand, treatment looks to mechanical alternatives. Rotary Ventricular Assist Devices, VADs, are miniature pumps which can be implanted alongside the heart to assist its pumping function. These constant flow devices are smaller, more efficient and promise a longer operational life than more traditional pulsatile VADs. The development of rotary VADs has focused on single pumps assisting the left ventricle only to supply blood for the body. In many patients however, failure of both ventricles demands that an additional pulsatile device be used to support the failing right ventricle. This condition renders them hospital bound while they wait for an unlikely heart donation. Reported attempts to use two rotary pumps to support both ventricles concurrently have warned of inherent haemodynamic instability. Poor balancing of the pumps’ flow rates quickly leads to vascular congestion increasing the risk of oedema and ventricular ‘suckdown’ occluding the inlet to the pump. This thesis introduces a novel Bi-Ventricular Assist Device (BiVAD) configuration where the pump outputs are passively balanced by vascular pressure. The BiVAD consists of two rotary pumps straddling the mechanical passive controller. Fluctuations in vascular pressure induce small deflections within both pumps adjusting their outputs allowing them to maintain arterial pressure. To optimise the passive controller’s interaction with the circulation, the controller’s dynamic response is optimised with a spring, mass, damper arrangement. This two part study presents a comprehensive assessment of the prototype’s ‘viability’ as a support device. Its ‘viability’ was considered based on its sensitivity to pathogenic haemodynamics and the ability of the passive response to maintain healthy circulation. The first part of the study is an experimental investigation where a prototype device was designed and built, and then tested in a pulsatile mock circulation loop. The BiVAD was subjected to a range of haemodynamic imbalances as well as a dynamic analysis to assess the functionality of the mechanical damper. The second part introduces the development of a numerical program to simulate human circulation supported by the passively controlled BiVAD. Both investigations showed that the prototype was able to mimic the native baroreceptor response. Simulating hypertension, poor flow balancing and subsequent ventricular failure during BiVAD support allowed the passive controller’s response to be assessed. Triggered by the resulting pressure imbalance, the controller responded by passively adjusting the VAD outputs in order to maintain healthy arterial pressures. This baroreceptor-like response demonstrated the inherent stability of the auto regulating BiVAD prototype. Simulating pulmonary hypertension in the more observable numerical model, however, revealed a serious issue with the passive response. The subsequent decrease in venous return into the left heart went unnoticed by the passive controller. Meanwhile the coupled nature of the passive response not only decreased RVAD output to reduce pulmonary arterial pressure, but it also increased LVAD output. Consequently, the LVAD increased fluid evacuation from the left ventricle, LV, and so actually accelerated the onset of LV collapse. It was concluded that despite the inherently stable baroreceptor-like response of the passive controller, its lack of sensitivity to venous return made it unviable in its present configuration. The study revealed a number of other important findings. Perhaps the most significant was that the reduced pulse experienced during constant flow support unbalanced the ratio of effective resistances of both vascular circuits. Even during steady rotary support therefore, the resulting ventricle volume imbalance increased the likelihood of suckdown. Additionally, mechanical damping of the passive controller’s response successfully filtered out pressure fluctuations from residual ventricular function. Finally, the importance of recognising inertial contributions to blood flow in the atria and ventricles in a numerical simulation were highlighted. This thesis documents the first attempt to create a fully auto regulated rotary cardiac assist device. Initial results encourage development of an inlet configuration sensitive to low flow such as collapsible inlet cannulae. Combining this with the existing baroreceptor-like response of the passive controller will render a highly stable passively controlled BiVAD configuration. The prototype controller’s passive interaction with the vasculature is a significant step towards a highly stable new generation of artificial heart.
Resumo:
Objective: This study aimed to investigate rates of psychiatric disorder in human immunodeficiency virus (HIV) infection, in an Australian sample of homosexual and bisexual men. Method: A cross-sectional study of a total of 65 HIV sero-negative (HIV-) and 164 HIV sero-positive men (HIVt) (79 CDC stage 1 1/1 11 and 85 CDC stage IV) was conducted in three centres. Lifetime and current prevalence rates of psychiatric disorder were evaluated using the Diagnostic Interview Schedule Version lllR (DIS-IIIR). Results: Elevated current and lifetime rates of major depression were detected in both HIV negative and HIV positive homosexual/bisexual men. Lifetime rates of alcohol abuseldependence were significantly elevated in HIV positive men (CDC group IV) when compared with HIV negative men. Among the HIV positive group the majority of psychiatric disorders detected were preceded by a pre-HIV diagnosis of psychiatric disorder. Major depression represented the disorder most likely to have first onset after HIV infection diagnosis. Conclusions: Lifetime rates of major depression were elevated in this sample of HIV-negative and HIV-positive men, In the HIV-positive men, psychiatric disorder was significantly associated with the presence of lifetime psychiatric disorder prior to HIV infection diagnosis, The findings indicate the importance of evaluation of psychiatric history prior to HIV infection and the clinical significance of depressive syndromes in this population.
Resumo:
This study investigated the psychological impact of HIV infection through assessment of posttraumatic stress disorder in response to HIV infection. Sixty-one HIV-positive homosexual/bisexual men were assessed for posttraumatic stress disorder in response to HIV infection (PTSD-HIV) using a modified PTSD module of the DIS-III-R. Thirty percent met criteria for a syndrome of posttraumatic stress disorder in response to HIV diagnosis (PTSD-HIV). In over one-third of the PTSD cases, the disorder had an onset greater than 6 months after initial HIV infection diagnosis. PTSD-HIV was associated with other psychiatric diagnoses, particularly the development of first episodes of major depression after HIV infection diagnosis. PTSD-HIV was significantly associated with a pre-HIV history of PTSD from other causes, and other pre-HIV psychiatric disorders and neuroticism scores, indicating a similarity with findings in studies of PTSD from other causes. The findings from this preliminary study suggest that a PTSD response to HIV diagnosis has clinical validity and requires further investigation in this population and other medically ill groups. The results support the inclusion of the diagnosis of life-threatening illness as a traumatic incident that may lead to a posttraumatic stress disorder, which is consistent with the DSM-IV criteria.
Resumo:
This study addressed why girls are less likely to be referred for mental health services for attention deficit/hyperactivity disorder (ADHD) than boys. Ninety-six parents of children with elevated ADHD symptoms and 140 elementary school teachers read vignettes about children with ADHD. Half of the participants read vignettes with boys' names, and half read the same vignettes but with girls' names. Participants then rated their likeliness to seek or recommend services for the child in each vignette. Parents and teachers were less likely to seek or recommend services for girls than boys with ADHD, but results did not support the hypothesis that this is because girls are less disruptive than boys. Rather, differences in service seeking were explained by the fact that parents and teachers believed that learning assistance is less effective for girls than boys with ADHD.
Resumo:
Objectives. We tested predictions from the elaborated intrusion (EI) theory of desire, which distinguishes intrusive thoughts and elaborations, and emphasizes the importance of imagery. Secondarily, we undertook preliminary evaluations of the Alcohol Craving Experience (ACE) questionnaire, a new measure based on EI Theory. Methods. Participants (N ¼ 232) were in correspondence-based treatment trials for alcohol abuse or dependence. The study used retrospective reports obtained early in treatment using the ACE, and daily self-monitoring of urges, craving, mood and alcohol consumption. Results. The ACE displayed high internal consistency and test – retest reliability and sound relationships with self-monitored craving, and was related to Baseline alcohol dependence, but not to consumption. Imagery during craving was experienced by 81%,with 2.3 senses involved on average. More frequent imagery was associated with longer episode durations and stronger craving. Transient intrusive thoughts were reported by 87% of respondents, and were more common if they frequently attempted to stop alcohol cognitions. Associations between average daily craving and weekly consumption were seen. Depression and negative mood were associated with more frequent, stronger and longer lasting desires for alcohol. Conclusions. Results supported the distinction of automatic and controlled processes in craving, together with the importance of craving imagery. They were also consistent with prediction of consumption from cross-situational averages of craving, and with positive associations between craving and negative mood. However, this study’s retrospective reporting and correlational design require that its results be interpreted cautiously. Research using ecological momentary measures and laboratory manipulations is needed before confident inferences about causality can be made.