53 resultados para Newborn infants
Resumo:
Saliva contains a number of biochemical components which may be useful for diagnosis/monitoring of metabolic disorders, and as markers of cancer or heart disease. Saliva collection is attractive as a non-invasive sampling method for infants and elderly patients. We present a method suitable for saliva collection from neonates. We have applied this technique for the determination of salivary nucleotide metabolites. Saliva was collected from 10 healthy neonates using washed cotton swabs, and directly from 10 adults. Two methods for saliva extraction from oral swabs were evaluated. The analytes were then separated using high performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS). The limits of detection for 14 purine/pyrimidine metabolites were variable, ranging from 0.01 to 1.0 mu M. Recovery of hydrophobic purine/pyrimidine metabolites from cotton tips was consistently high using water/acetonitrile extraction (92.7-111%) compared with water extraction alone. The concentrations of these metabolites were significantly higher in neonatal saliva than in adults. Preliminary ranges for nucleotide metabolites in neonatal and adult saliva are reported. Hypoxanthine and xanthine were grossly raised in neonates (49.3 +/- 25.4; 30.9 +/- 19.5 mu M respectively) compared to adults (4.3 +/- 3.3; 4.6 +/- 4.5 mu M); nucleosides were also markedly raised in neonates. This study focuses on three essential details: contamination of oral swabs during manufacturing and how to overcome this; weighing swabs to accurately measure small saliva volumes; and methods for extracting saliva metabolites of interest from cotton swabs. A method is described for determining nucleotide metabolites using HPLC with photo-diode array or MS/MS. The advantages of utilising saliva are highlighted. Nucleotide metabolites were not simply in equilibrium with plasma, but may be actively secreted into saliva, and this process is more active in neonates than adults. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Aims Although suctioning is a standard airway maintenance procedure, there are significant associated risks, such as loss of lung volume due to high negative suction pressures. This study aims to assess the extent and duration of change in end-expiratory level (EEL) resulting from endotracheal tube (ETT) suction and to examine the relationship between EEL and regional lung ventilation in ventilated preterm infants with respiratory distress syndrome. Methods A prospective observational clinical study of the effect of ETT suction on 20 non-muscle-relaxed preterm infants with respiratory distress syndrome (RDS) on conventional mechanical ventilation was conducted in a neonatal intensive care unit. Ventilation distribution was measured with regional impedance amplitudes and EEL using electrical impedance tomography. Results ETT suction resulted in a significant increase in EEL post-suction (P < 0.01). Regionally, anterior EEL decreased and posterior EEL increased post-suction, suggesting heterogeneity. Tidal volume was significantly lower in volume-guarantee ventilation compared with pressure-controlled ventilation (P = 0.04). Conclusions ETT suction in non-muscle-relaxed and ventilated preterm infants with RDS results in significant lung volume increase that is maintained for at least 90 min. Regional differences in distribution of ventilation with ETT suction suggest that the behaviour of the lung is heterogeneous in nature.
Resumo:
Aim: This study aimed to document the growth patterns of a contemporary cohort of preterm infants born appropriate for gestational age (AGA). It was hypothesised that preterm AGA (PT-AGA) infants would display poorer growth than full-term AGA (FT-AGA) infants. Methods: Sixty-four PT-AGA infants and 64 FT-AGA infants were assessed at 0, 4, 8 and 12 months of corrected age (CA). Measurements of weight and length were recorded at each of the specified ages. Centers for Disease Control and Prevention growth data were used to calculate Z-scores for weight and length based on CA. Results: The mean length and weight Z-scores of PT-AGA infants were found to be significantly less than those of FT-AGA infants at term, 4, 8 and 12 months of CA (P < 0.001). The mean weight Z-score of PT-AGA infants was found to be less than their mean length Z-score at each time point, though the differences were not significant. Conclusions: The results of this study suggest that PT-AGA infants are likely to display poorer growth than FT-AGA infants until at least 1 year of CA. Long-term growth monitoring in this population is recommended. © 2008 The Authors.
Resumo:
To compare the efficacy of a low-lactose hy-drolyzed milk formula, a lactose-free corn syrup-based milk formula, and a standard lactose-containing formula during refeeding after rehydration in infants with gastroenteritis, 135 patients older than 2 years were studied by randomized trial. Clearly demonstrated disadvantages in terms of early weight loss and longer duration of diarrhea were observed with the lactose-based formula compared with early weight gains on both the low-lactose formulae, and thus the lactose-containing formula was discontinued after 91 patients. The early weight loss with the lactose-containing formula was statistically significantly related to the degree of relative (rehydrated) underweight. The two low-lactose formulae were further compared in the remaining 44 patients. Early weight gain (48 h) was sig-nificantly greater with the lactose-hydrolyzed formula compared with the corn syrup-based formula, but no statistically significant differences were observed in duration of diarrhea, energy intake, treatment failures, or late weight gain. We conclude that the routine use of a low-lactose formula during refeeding after rehydration in infants with gastroenteritis may have some advantages in underweight infants and toddlers in whom it is important to prevent further weight loss. © 1994 Raven Press Ltd, New York.
Resumo:
This study evaluates the effectiveness and social implications of home monitoring of 31 infants at risk of sudden infant death syndrome (SIDS). Thirteen siblings of children dying of SIDS, nine near miss SIDS infants and nine preterm infants with apnoea persisting beyond 40 weeks post conceptual age were monitored from a mean age of 15 days to a mean of 10 months. Chest movement detection monitors were used in 27 and thoracic impedance monitors in four. Genuine apnoeic episodes were reported by 21 families, and 13 infants required resuscitation. Apnoeic episodes occurred in all nine preterm infants but in only five (38%) of the siblings of SIDS (P<0.05). Troublesome false alarms were a major problem occurring with 61% of the infants and were more common with the preterm infants than the siblings of SIDS. All but two couples stated that the monitor decreased anxiety and improved their quality of life. Most parents accepted that the social restrictions imposed by the monitor were part of the caring process but four couples were highly resentful of the changes imposed on their lifestyle. The monitors used were far from ideal with malfunction occurring in 17, necessitating replacement in six, repair in six and cessation of monitoring in three. The parents became ingenious in modifying the monitors to their own individual requirements Although none of these 31 ‘at risk’ infants died the study sample was far too small to conclude whether home monitoring prevented any cases of SIDS.
Resumo:
The effects of increasing the concentration of supplemental vitamin D was studied in two groups of ELBW infants (babies with a birth weight less than 1000 g) during the periods of July 1977 to December 1979 and throughout 1980. There were 21 ELBW infants in the first study period, with 7 infants developing active or stage III rickets. A prospective study of ELBW infants during 1980 revealed 3 infants out of the 12 studied developing active or Stage III rickets. A new radiological classification for rickets of prematurity, Stage I to IV, is presented. Serial serum alkaline phosphatase levels were then compared with these radiological stages and a serial ALP of 5001U/l was found to be statistically significant in the biochemical diagnosis of rickets. As a result of our findings, we suggest that all ELBW would be supplemented with at least 800 IU of vitamin D daily.
Resumo:
Ultrasound screening is now a routine procedure which forms part of antenatal care provision. Within this routine context ultrasound technology has been found to be generally acceptable and indeed is positively demanded by many women. This paper raises the question whether the routine presentation of ultrasound implicitly conveys the message that is use in antenatal care is both valuable and safe. It examines women's views of ultrasound technology beyond a routine context. In a study designed to examine women's reactions to cerebral ultrasound on their normal term infants mothers were asked their views and knowledge of ultrasound and a comparison with their antenatal experience of ultrasound was elicited. A generalized concern about ultrasound techniques was found to underlie many of the women's comments. This raised questions concerning the current practice in the presentation of ultrasound to women attending for antenatal care.
Resumo:
When infants are weighed at well baby or infant welfare clinics, the weight change from one visit to the next is used as a guide to the welfare of the child. Infant welfare clinic nurses are expert clinicians who use weight measurements as a rough indicator of well-being only, as it is well known by them that these measurements are fraught with error. This paper calculates the amount of error which was found in repeated tests of weights of infants, and in the weight changes brought about by biological variation. As a result, it is recommended that babies under nine months of age be weighed at clinic visits no less than a fortnight apart, and older infants, at least one month apart. If they are weighed more often, then the weight changes detected will be less than the amount of error which affects the measurements.