31 resultados para Apparent porosity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteogenesis imperfecta (OI) is a heritable disease occurring in one out of every 20,000 births. Although it is known that Type I collagen mutation in OI leads to increased bone fragility, the mechanism of this increased susceptibility to fracture is not clear. The aim of this study was to assess the microstructure of cortical bone fragments from patients with osteogenesis imperfecta (OI) using polarized light microscopy, and to correlate microstructural observations with the results of previously performed mechanical compression tests on bone from the same source. Specimens of cortical bone were harvested from the lower limbs of three (3) OI patients at the time of surgery, and were divided into two groups. Group 1 had been subjected to previous micro-mechanical compression testing, while Group 2 had not been subjected to any prior testing. Polarized light microscopy revealed disorganized bone collagen architecture as has been previously observed, as well as a large increase in the areal porosity of the bone compared to typical values for healthy cortical bone, with large (several hundred micron sized), asymmetrical pores. Importantly, the areal porosity of the OI bone samples in Group 1 appears to correlate strongly with their previously measured apparent Young's modulus and compressive strength. Taken together with prior nanoindentation studies on OI bone tissue, the results of this study suggest that increased intra-cortical porosity is responsible for the reduction in macroscopic mechanical properties of OI cortical bone, and therefore that in vivo imaging modalities with resolutions of ~ 100 μm or less could potentially be used to non-invasively assess bone strength in OI patients. Although the number of subjects in this study is small, these results highlight the importance of further studies in OI bone by groups with access to human OI tissue in order to clarify the relationship between increased porosity and reduced macroscopic mechanical integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unusual behaviour of fine lunar regolith like stickiness and low heat conductivity is dominated by the structural arrangement of its finest fraction. Here, we show the previously unknown phenomenon of a globular 3D superstructure within the dust fraction of regolith. A study using the recently developed Transmission X-ray Microscopy (TXM) with tomographic reconstruction reveals a highly porous network of cellular voids in the finest dust fraction aggregates in lunar soil. Such porous chained aggregates are composed of sub-micron particles that form a network of cellular voids a few micrometers in diameter. Discovery of such a superstructure within the finest fraction of lunar topsoil enables a model of heat transfer to be constructed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was conducted to explore the potential to incorporate local plant-based feed ingredients into diets formulated for the mud crab species, Scylla paramamosain, commonly exploited for aquaculture in South-east Asia. Four test ingredients (defatted soybean meal, rice bran, cassava meal and corn flour) were incorporated at 30% or 45% inclusion levels in a fishmeal-based reference diet and used in digestibility trials where apparent digestibility coefficients (ADCs) for experimental diets and test ingredients were determined. Generally, high ADC values were obtained using diets containing 30% soybean meal or rice bran. By contrast, the lowest ADC values were obtained for the diet containing 45% cassava meal [70.9% for dry matter (ADMD); 77.1% for crude protein (ACPD) and 80.2% for gross energy (AGED)]. Similar trends were observed when ADC ingredient (I) digestibilities were compared. Specifically, the highest ADCI values were obtained for soybean meal when used at a 30% inclusion level (87.6% ADMDI; 98.4% ACPDI and 95.6% AGEDI) while the lowest ADCI values were obtained using cassava meal at a 45% inclusion level (53.8% ADMDI; 60.2% ACPDI and 67.3% AGEDI). Based on the current findings, we propose that soybean meal and rice bran could be considered for incorporation into formulated diets for S. paramamosain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unusual behaviour of fine lunar regolith like stickiness and low heat conductivity is dominated by the structural arrangement of its finest fraction in the outer-most topsoil layer. Here, we show the previously unknown phenomenon of building a globular 3-D superstructure within the dust fraction of the regolith. New technology, Transmission X-ray Microscopy (TXM) with tomographic reconstruction, reveals a highly porous network of cellular void system in the lunar finest dust fraction aggregates. Such porous chained aggregates are composed of sub-micron in size particles that build cellular void networks. Voids are a few micrometers in diameter. Discovery of such a superstructure within the finest fraction of the lunar topsoil allow building a model of heat transfer which is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporotic spinal fractures are a major concern in ageing Western societies. This study develops a multi-scale finite element (FE) model of the osteoporotic lumbar vertebral body to study the mechanics of vertebral compression fracture at both the apparent (whole vertebral body) and micro-structural (internal trabecular bone core)levels. Model predictions were verified against experimental data, and found to provide a reasonably good representation of the mechanics of the osteoporotic vertebral body. This novel modelling methodology will allow detailed investigation of how trabecular bone loss in osteoporosis affects vertebral stiffness and strength in the lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Moon appears to be much larger closer to the horizon than when higher in the sky. This is called the ‘Moon Illusion’ since the observed size of the Moon is not actually larger when the Moon is just above the horizon. This article describes a technique for verifying that the observed size of the Moon in not larger on the horizon. The technique can be easily performed in a high school teaching environment. Moreover, the technique demonstrates the surprising fact that the observed size of the Moon is actually smaller on the horizon due to atmospheric refraction. For the purposes of this paper, several images of the moon were taken with the Moon close to the horizon and close to the zenith. Images were processed using a free program called ImageJ. The Moon was found to be 5.73 ±0.04% smaller in area on the horizon then at the zenith.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last few decades, electric and electromagnetic fields have achieved important role as stimulator and therapeutic facility in biology and medicine. In particular, low magnitude, low frequency, pulsed electromagnetic field has shown significant positive effect on bone fracture healing and some bone diseases treatment. Nevertheless, to date, little attention has been paid to investigate the possible effect of high frequency, high magnitude pulsed electromagnetic field (pulse power) on functional behaviour and biomechanical properties of bone tissue. Bone is a dynamic, complex organ, which is made of bone materials (consisting of organic components, inorganic mineral and water) known as extracellular matrix, and bone cells (live part). The cells give the bone the capability of self-repairing by adapting itself to its mechanical environment. The specific bone material composite comprising of collagen matrix reinforced with mineral apatite provides the bone with particular biomechanical properties in an anisotropic, inhomogeneous structure. This project hypothesized to investigate the possible effect of pulse power signals on cortical bone characteristics through evaluating the fundamental mechanical properties of bone material. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses up to 500 V and 10 kHz. Bone shows distinctive characteristics in different loading mode. Thus, functional behaviour of bone in response to pulse power excitation were elucidated by using three different conventional mechanical tests applying three-point bending load in elastic region, tensile and compressive loading until failure. Flexural stiffness, tensile and compressive strength, hysteresis and total fracture energy were determined as measure of main bone characteristics. To assess bone structure variation due to pulse power excitation in deeper aspect, a supplementary fractographic study was also conducted using scanning electron micrograph from tensile fracture surfaces. Furthermore, a non-destructive ultrasonic technique was applied for determination and comparison of bone elasticity before and after pulse power stimulation. This method provided the ability to evaluate the stiffness of millimetre-sized bone samples in three orthogonal directions. According to the results of non-destructive bending test, the flexural elasticity of cortical bone samples appeared to remain unchanged due to pulse power excitation. Similar results were observed in the bone stiffness for all three orthogonal directions obtained from ultrasonic technique and in the bone stiffness from the compression test. From tensile tests, no significant changes were found in tensile strength and total strain energy absorption of the bone samples exposed to pulse power compared with those of the control samples. Also, the apparent microstructure of the fracture surfaces of PP-exposed samples (including porosity and microcracks diffusion) showed no significant variation due to pulse power stimulation. Nevertheless, the compressive strength and toughness of millimetre-sized samples appeared to increase when the samples were exposed to 66 hours high power pulsed electromagnetic field through screws with small contact cross-section (increasing the pulsed electric field intensity) compare to the control samples. This can show the different load-bearing characteristics of cortical bone tissue in response to pulse power excitation and effectiveness of this type of stimulation on smaller-sized samples. These overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network causing the bone strength and toughness augmentation, it apparently did not affect the mineral phase of the cortical bone material. The results also confirmed that the indirect application of high power pulsed electromagnetic field at 500 V and 10 kHz through capacitive coupling method, was athermal and did not damage the bone tissue construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To identify risk factors for major Adverse Events (AEs) and to develop a nomogram to predict the probability of such AEs in individual patients who have surgery for apparent early stage endometrial cancer. Methods: We used data from 753 patients who were randomized to either total laparoscopic hysterectomy or total abdominal hysterectomy in the LACE trial. Serious adverse events that prolonged hospital stay or postoperative adverse events (using common terminology criteria 3+, CTCAE V3) were considered major AEs. We analyzed pre-surgical characteristics that were associated with the risk of developing major AEs by multivariate logistic regression. We identified a parsimonious model by backward stepwise logistic regression. The six most significant or clinically important variables were included in the nomogram to predict the risk of major AEs within 6 weeks of surgery and the nomogram was internally validated. Results: Overall, 132 (17.5%) patients had at least one major AE. An open surgical approach (laparotomy), higher Charlson’s medical co-morbidities score, moderately differentiated tumours on curettings, higher baseline ECOG score, higher body mass index and low haemoglobin levels were associated with AE and were used in the nomogram. The bootstrap corrected concordance index of the nomogram was 0.63 and it showed good calibration. Conclusions: Six pre-surgical factors independently predicted the risk of major AEs. This research might form the basis to develop risk reduction strategies to minimize the risk of AEs among patients undergoing surgery for apparent early stage endometrial cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the clinical value of pre-operative serum CA125 in predicting the presence of extra-uterine disease in patients with apparent early stage endometrial cancer. Methods: Between October 6, 2005 and June 17, 2010, 760 patients were enrolled in an international, multicentre, prospective randomized trial (LACE) comparing laparotomy with laparoscopy in the management of endometrial cancer apparently confined to the uterus. This study is based on data from 657 patients with endometrial adenocarcinoma who had a pre-operative serum CA125 value, and was undertaken to correlate pre-operative serum CA125 with final stage. Results: Using a pre-operative CA-125 cutpoint of 30U/ml was associated with the smallest misclassification error (14.5%) using a multiple cross-validation method. Median pre-operative serum CA-125 was 14U/ml, and using a cutpoint of 30U/ml, 14.9% of patients had elevated CA-125 levels. Of 98 patients with elevated CA-125 level, 36 (36.7%) had evidence of extra-uterine disease. Of the 116 patients (17.7%) with evidence of extra-uterine disease, 31.0% had elevated CA-125 level. In univariate and multivariate logistic regression analysis, only pre-operative CA-125 level was found to be associated with extra-uterine spread of disease. Utilising a cutpoint of 30U/ml achieved a sensitivity, specificity, positive predictive value and negative predictive value of 31.0%, 88.5%, 36.7% and 85.7% respectively. Overall, 326/657 (49.6%) of patients had full surgical staging involving lymph node dissection. When analysis was limited to patients that had undergone full surgical staging, the outcomes remained essentially unchanged. Conclusions: Elevated CA-125 above 30U/ml in patients with apparent early stage disease is associated with a sensitivity of 31.0% and specificity of 88.5% in detecting extra-uterine disease. Pre-operative identification of this risk factor may assist to triage patients to tertiary centres and comprehensive surgical staging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To compare Total Laparoscopic Hysterectomy (TLH) and Total Abdominal Hysterectomy (TAH) with regard to surgical safety. METHODS: Between October 2005 and June 2010, 760 patients with apparent early stage endometrial cancer were enroled in a multicentre, randomised clinical trial (LACE) comparing outcomes following TLH or TAH. The main study end points for this analysis were surgical adverse events (AE), hospital length of stay, conversion from laparoscopy to laparotomy, including 753 patients who completed at least 6 weeks of follow-up. Postoperative AEs were graded according to Common Toxicity Criteria (V3), and those immediately life-threatening, requiring inpatient hospitalisation or prolonged hospitalisation, or resulting in persistent or significant disability/incapacity were regarded as serious AEs. RESULTS: The incidence of intra-operative AEs was comparable in either group. The incidence of post-operative AE CTC grade 3+ (18.6% in TAH, 12.9% in TLH, p 0.03) and serious AE (14.3% in TAH, 8.2% in TLH, p 0.007) was significantly higher in the TAH group compared to the TLH group. Mean operating time was 132 and 107 min, and median length of hospital stay was 2 and 5 days in the TLH and TAH group, respectively (p<0.0001). The decline of haemoglobin from baseline to day 1 postoperatively was 2g/L less in the TLH group (p 0.006). CONCLUSIONS: Compared to TAH, TLH is associated with a significantly decreased risk of major surgical AEs. A laparoscopic surgical approach to early stage endometrial cancer is safe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of epoxy embedding and microtomy to individual chondritic interplanetary dust particles (lOP's)(Bradley and Brownlee, 1986a) provides not only higher precision in thin-film elemental analyses (Bradley and Brownlee, 19861:1), but also allows a wealth of other important techniques for the micro-characterization of these primitive extraterrestrial materials. For example, individual sections (e.g. 100 nm thick) or a series of sections, can be examined using image analysis techniques which utilize either transmitted or scanned secondary electron images, or alternatively, secondary X-ray spectra collected concurrently from a given region of sample. Individual particles, or groups of particles with similar image characteristics can then be rapidly identified using conventional grey-scale/particle recognition techniques for each microtomed section of lOP. This type of image analysis provides a suitable method for determination of particle size and shape distribution as well as porosity throughout the aggregate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To ensure better concrete quality and long-term durability, there has been an increasing focus in recent years on the development of test methods for quality control of concrete. This paper presents a study to evaluate the effect of water accessible porosity and oven-dry unit weight on the resistance of concrete to chloride-ion penetration. Based on the experimental results and regression analyses, empirical relationships of the charge passed (ASTM C 1202) and chloride migration coefficient (NT Build 492) versus the water accessible porosity and oven dry unit weight of the concrete are established. Using basic physical properties of water accessible porosity and oven dry unit weight which can be easily determined, total charge passed and migration coefficient of the concrete can be estimated for quality control and for estimating durability of concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multilamellar structure of phospholipids, i.e. the surface amorphous layer (SAL) that covers the natural surface of articular cartilage, and hexagonal boron nitride (h-BN) on the surface of metal porous bearings are two prominent examples of the family of layered materials that possess the ability to deliver lamellar lubrication. This chapter presents the friction study that was conducted on the surfaces of cartilage and the metal porous bearing impregnated with oil (first generation) and with oil + h-BN (second generation). The porosity of cartilage is around 75% and those of metal porous bearings were 15–28 wt%. It is concluded that porosity is a critical factor in facilitating the excellent tribological properties of both articular cartilage and the porous metal bearings studied.