9 resultados para size accuracy

em Universidade do Minho


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biometric systems are increasingly being used as a means for authentication to provide system security in modern technologies. The performance of a biometric system depends on the accuracy, the processing speed, the template size, and the time necessary for enrollment. While much research has focused on the first three factors, enrollment time has not received as much attention. In this work, we present the findings of our research focused upon studying user’s behavior when enrolling in a biometric system. Specifically, we collected information about the user’s availability for enrollment in respect to the hand recognition systems (e.g., hand geometry, palm geometry or any other requiring positioning the hand on an optical scanner). A sample of 19 participants, chosen randomly apart their age, gender, profession and nationality, were used as test subjects in an experiment to study the patience of users enrolling in a biometric hand recognition system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study investigated whether oculomotor behavior is influenced by attachment styles. The Relationship Scales Questionnaire was used to assess attachment styles of forty-eight voluntary university students and to classify them into attachment groups (secure, preoccupied, fearful, and dismissing). Eye-tracking was recorded while participants engaged in a 3-seconds free visual exploration of stimuli presenting either a positive or a negative picture together with a neutral picture, all depicting social interactions. The task consisted in identifying whether the two pictures depicted the same emotion. Results showed that the processing of negative pictures was impermeable to attachment style, while the processing of positive pictures was significantly influenced by individual differences in insecure attachment. The groups highly avoidant regarding to attachment (dismissing and fearful) showed reduced accuracy, suggesting a higher threshold for recognizing positive emotions compared to the secure group. The groups with higher attachment anxiety (preoccupied and fearful) showed differences in automatic capture of attention, in particular an increased delay preceding the first fixation to a picture of positive emotional valence. Despite lenient statistical thresholds induced by the limited sample size of some groups (p < 0.05 uncorrected for multiple comparisons), the current findings suggest that the processing of positive emotions is affected by attachment styles. These results are discussed within a broader evolutionary framework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tri-layered and bi-layered magnetoelectric (ME) flexible composite structures of varying geometries and sizes consisting on magnetostrictive Vitrovac and piezoelectric poly(vinylidene fluoride) (PVDF) layers were fabricated by direct bonding. From the ME measurements it was determined that tri-layered composites structures (magnetostrictive-piezoelectric-magnetostrictive type), show a higher ME response (75 V.cm-1.Oe-1) than the bi-layer structure (66 V.cm 1.Oe-1). The ME voltage coefficient decreased with increasing longitudinal size aspect ratio between PVDF and Vitrovac layers (from 1.1 to 4.3), being observed a maximum ME voltage coefficient of 66 V.cm-1.Oe-1. It was also observed that the composite with the lowest transversal aspect ratio between PVDF and Vitrovac layers resulted in better ME performance than the structures with higher transversal size aspect ratios. It was further determined an intimate relation between the Vitrovac PVDF Area Area ratio and the ME response of the composites. When such ratio values approach 1, the ME response is the largest. Additionally the ME output value and magnetic field response was controlled by changing the number of Vitrovac layers, which allows the development of magnetic sensors and energy harvesting devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia de Materiais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed data aggregation is an important task, allowing the de- centralized determination of meaningful global properties, that can then be used to direct the execution of other applications. The resulting val- ues result from the distributed computation of functions like count, sum and average. Some application examples can found to determine the network size, total storage capacity, average load, majorities and many others. In the last decade, many di erent approaches have been pro- posed, with di erent trade-o s in terms of accuracy, reliability, message and time complexity. Due to the considerable amount and variety of ag- gregation algorithms, it can be di cult and time consuming to determine which techniques will be more appropriate to use in speci c settings, jus- tifying the existence of a survey to aid in this task. This work reviews the state of the art on distributed data aggregation algorithms, providing three main contributions. First, it formally de nes the concept of aggrega- tion, characterizing the di erent types of aggregation functions. Second, it succinctly describes the main aggregation techniques, organizing them in a taxonomy. Finally, it provides some guidelines toward the selection and use of the most relevant techniques, summarizing their principal characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Symbolic Aggregate Approximation (iSAX) is widely used in time series data mining. Its popularity arises from the fact that it largely reduces time series size, it is symbolic, allows lower bounding and is space efficient. However, it requires setting two parameters: the symbolic length and alphabet size, which limits the applicability of the technique. The optimal parameter values are highly application dependent. Typically, they are either set to a fixed value or experimentally probed for the best configuration. In this work we propose an approach to automatically estimate iSAX’s parameters. The approach – AutoiSAX – not only discovers the best parameter setting for each time series in the database, but also finds the alphabet size for each iSAX symbol within the same word. It is based on simple and intuitive ideas from time series complexity and statistics. The technique can be smoothly embedded in existing data mining tasks as an efficient sub-routine. We analyze its impact in visualization interpretability, classification accuracy and motif mining. Our contribution aims to make iSAX a more general approach as it evolves towards a parameter-free method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The suitability of a total-length-based, minimum capture-size and different protection regimes was investigated for the gooseneck barnacle Pollicipes pollicipes shellfishery in N Spain. For this analysis, individuals that were collected from 10 sites under different fishery protection regimes (permanently open, seasonally closed, and permanently closed) were used. First, we applied a non-parametric regression model to explore the relationship between the capitulum Rostro-Tergum (RT) size and the Total Length (TL). Important heteroskedastic disturbances were detected for this relationship, demon- strating a high variability of TL with respect to RT. This result substantiates the unsuitability of a TL-based minimum size by means of a mathematical model. Due to these disturbances, an alternative growth- based minimum capture size of 26.3 mm RT (23 mm RC) was estimated using the first derivative of a Kernel-based non-parametric regression model for the relationship between RT and dry weight. For this purpose, data from the permanently protected area were used to avoid bias due to the fishery. Second, the size-frequency distribution similarity was computed using a MDS analysis for the studied sites to evaluate the effectiveness of the protection regimes. The results of this analysis indicated a positive effect of the permanent protection, while the effect of the seasonal closure was not detected. This result needs to be interpreted with caution because the current harvesting based on a potentially unsuitable mini- mum capture size may dampen the efficacy of the seasonal protection regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Comunicação, Arte e Cultura